{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T01:13:07Z","timestamp":1783732387242,"version":"3.55.0"},"reference-count":44,"publisher":"American Academy of Implant Dentistry","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,2]]},"abstract":"<jats:p>\n                    There are limited studies analyzing the accuracy of desktop scanners with scan bodies made of different materials but of the same design. The purpose of this in vitro study is to examine the effect of scan bodies made of titanium and polyetheretherketone (PEEK) on the accuracy of desktop scanners that have different scanning technologies (white light vs blue light). Two upper jaw models with a missing left second premolar were obtained. An implant (Bilimplant) was placed in the area where the missing tooth was located. The titanium and PEEK scan bodies were torqued, and an industrial scanner obtained reference data. A total of 40 scans were recorded using two desktop scanners (Dentium and Kivi). Ti-Dentium, Ti-Kivi, PEEK-Dentium, and PEEK-Kivi were identified as the four test groups. Each STL file was imported into Geomagic for reverse engineering. The deviation between the experimental scan and the reference data was analyzed using a best-fit algorithm to determine the accuracy of each scan. Deviation values were compared using nonparametric tests. The average deviation values \u00b1 standard deviation observed across the groups were 65 \u00b1 4.5 \u03bcm, 81 \u00b1 3.1 \u03bcm, 24 \u00b1 5.4 \u03bcm, and 47 \u00b1 9.1 \u03bcm, respectively. Group Ti-K exhibited the highest average deviation, whereas Group PEEK-D demonstrated the lowest. A statistically significant difference was found between all groups (\n                    <jats:italic>P<\/jats:italic>\n                    &lt; .05). Within the limitations of this in vitro study, PEEK scan bodies and white light scanners demonstrated superior accuracy, which may be clinically relevant in high-precision implant restorations.\n                  <\/jats:p>","DOI":"10.1563\/aaid-joi-d-25-00133","type":"journal-article","created":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T15:45:32Z","timestamp":1763739932000},"page":"76-81","source":"Crossref","is-referenced-by-count":1,"title":["Assessing the Influence of Implant Scan Body Material on Desktop Scanner Accuracy: An In Vitro Study"],"prefix":"10.1563","volume":"52","author":[{"given":"Nur\u015fen","family":"\u015eahin","sequence":"first","affiliation":[{"name":"Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Giresun University, Giresun, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Necati","family":"Kaleli","sequence":"additional","affiliation":[{"name":"Associate Professor, Dental Prosthesis Technology, Vocational School of Health Services, Ondokuz May\u0131s Un\u0131versity, Samsun, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elif","family":"Nazl\u0131 Tekin","sequence":"additional","affiliation":[{"name":"Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Giresun University, Giresun, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u00c7a\u011fr\u0131","family":"Ural","sequence":"additional","affiliation":[{"name":"Professor, Department of Prosthodontics, Faculty of Dentistry, Giresun University, Giresun, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"434","reference":[{"key":"i1548-1336-52-1-76-b01","series-title":"J Dent","first-page":"104892","article-title":"Accuracy of conventional impressions and digital scans for implant-supported fixed prostheses in maxillary free-ended partial edentulism: an in vitro study","volume":"143","author":"El Osta","year":"2024","unstructured":"El Osta N,\nDrancourt N,\nAuduc C,\nVeyrune JL,\nNicolas E. Accuracy of conventional impressions and digital scans for implant-supported fixed prostheses in maxillary free-ended partial edentulism: an in vitro study. J Dent. 2024;143:104892."},{"key":"i1548-1336-52-1-76-b02","series-title":"Clin Oral Implants Res","first-page":"374","article-title":"The accuracy of different dental impression techniques for implant-supported dental prostheses: a systematic review and meta-analysis","volume":"29","author":"Fl\u00fcgge","year":"2018","unstructured":"Fl\u00fcgge T,\nvan der Meer WJ,\nGonzalez BG,\nVach K,\nWismeijer D,\nWang P. The accuracy of different dental impression techniques for implant-supported dental prostheses: a systematic review and meta-analysis. Clin Oral Implants Res. 2018;29:374\u2013392."},{"key":"i1548-1336-52-1-76-b03","series-title":"J Prosthet Dent","first-page":"735","article-title":"Three-dimensional positional accuracy of intraoral and laboratory implant scan bodies","volume":"128","author":"Tan","year":"2022","unstructured":"Tan JZH,\nTan MY,\nSee Toh YL,\nWong KY,\nTan KBC. Three-dimensional positional accuracy of intraoral and laboratory implant scan bodies. J Prosthet Dent. 2022;128:735\u2013744."},{"key":"i1548-1336-52-1-76-b04","series-title":"J Prosthet Dent","first-page":"1001","article-title":"Accuracy of three digital scanning methods for complete-arch tooth preparation: an in vitro comparison","volume":"128","author":"Gao","year":"2022","unstructured":"Gao H,\nLiu X,\nLiu M,\nYang X,\nTan J. Accuracy of three digital scanning methods for complete-arch tooth preparation: an in vitro comparison. J Prosthet Dent. 2022;128:1001\u20131008."},{"key":"i1548-1336-52-1-76-b05","series-title":"J Prosthodont","first-page":"581","article-title":"An in vitro comparison of the marginal adaptation accuracy of CAD\/CAM restorations using different impression systems","volume":"26","author":"Shembesh","year":"2017","unstructured":"Shembesh M,\nAli A,\nFinkelman M,\nWeber HP,\nZandparsa R. An in vitro comparison of the marginal adaptation accuracy of CAD\/CAM restorations using different impression systems. J Prosthodont. 2017;26:581\u2013586."},{"key":"i1548-1336-52-1-76-b06","series-title":"J Dent","first-page":"104220","article-title":"Understanding the effect of scan spans on the accuracy of intraoral and desktop scanners","volume":"124","author":"Chen","year":"2022","unstructured":"Chen Y,\nZhai Z,\nWatanabe S,\nNakano T,\nIshigaki S. Understanding the effect of scan spans on the accuracy of intraoral and desktop scanners. J Dent. 2022;124:104220."},{"key":"i1548-1336-52-1-76-b07","series-title":"J Prosthodont","first-page":"314","article-title":"Evaluation of the accuracy of digital impressions obtained from intraoral and extraoral dental scanners with different CAD\/CAM scanning technologies: an in vitro study","volume":"31","author":"Ellakany","year":"2022","unstructured":"Ellakany P,\nTantawi ME,\nMahrous AA,\nAl-Harbi F. Evaluation of the accuracy of digital impressions obtained from intraoral and extraoral dental scanners with different CAD\/CAM scanning technologies: an in vitro study. J Prosthodont. 2022;31:314\u2013319."},{"key":"i1548-1336-52-1-76-b08","series-title":"J Prosthet Dent","first-page":"194","article-title":"A three-dimensional evaluation of a laser scanner and a touch-probe scanner","volume":"95","author":"Persson","year":"2006","unstructured":"Persson A,\nAndersson M,\nOden A,\nSandborgh-Englund G. A three-dimensional evaluation of a laser scanner and a touch-probe scanner. J Prosthet Dent. 2006;95:194\u2013200."},{"key":"i1548-1336-52-1-76-b09","series-title":"J Dent","first-page":"104391","article-title":"In vitro comparison of five desktop scanners and an industrial scanner in the evaluation of an intraoral scanner accuracy","volume":"129","author":"Borbola","year":"2023","unstructured":"Borbola D,\nBerkei G,\nSimon B, et al. In vitro comparison of five desktop scanners and an industrial scanner in the evaluation of an intraoral scanner accuracy. J Dent. 2023;129:104391."},{"key":"i1548-1336-52-1-76-b10","series-title":"Dent Mater","first-page":"682","article-title":"Differences in the biomechanical behaviors of natural teeth and dental implants","volume":"37","author":"Chang","year":"2021","unstructured":"Chang HH,\nYeh CL,\nWang YL, et al. Differences in the biomechanical behaviors of natural teeth and dental implants. Dent Mater. 2021;37:682\u2013689."},{"key":"i1548-1336-52-1-76-b11","series-title":"Int J Oral Implantol (Berl)","first-page":"157","article-title":"Accuracy of full-arch digital implant impressions taken using intraoral scanners and related variables: a systematic review","volume":"14","author":"Zhang","year":"2021","unstructured":"Zhang YJ,\nShi JY,\nQian SJ,\nQiao SC,\nLai HC. Accuracy of full-arch digital implant impressions taken using intraoral scanners and related variables: a systematic review. Int J Oral Implantol (Berl). 2021;14:157\u2013179."},{"key":"i1548-1336-52-1-76-b12","series-title":"J Clin Sci","first-page":"127","article-title":"Assessing the impact of various intraoral scanners on the accuracy of dental implant impression","volume":"13","author":"Ceylan","year":"2024","unstructured":"Ceylan G,\nDemirel M,\nT\u00fcrksayar AAD,\nEmir F,\nD\u00f6nmez MB. Assessing the impact of various intraoral scanners on the accuracy of dental implant impression. J Clin Sci. 2024;13:127\u2013134."},{"key":"i1548-1336-52-1-76-b13","series-title":"Int J Environ Res Public Health","first-page":"4776","article-title":"Intraoral scans of full dental arches: an in vitro measurement study of the accuracy of different intraoral scanners","volume":"20","author":"Giuliodori","year":"2023","unstructured":"Giuliodori G,\nRappelli G,\nAquilanti L. Intraoral scans of full dental arches: an in vitro measurement study of the accuracy of different intraoral scanners. Int J Environ Res Public Health. 2023;20:4776."},{"key":"i1548-1336-52-1-76-b14","series-title":"J Prosthet Dent","first-page":"1160","article-title":"Effect of scanning speed, scanning pattern, and tip size on the accuracy of intraoral digital scans","volume":"131","author":"An","year":"2024","unstructured":"An H,\nLangas EE,\nGill AS. Effect of scanning speed, scanning pattern, and tip size on the accuracy of intraoral digital scans. J Prosthet Dent. 2024;131:1160\u20131167."},{"key":"i1548-1336-52-1-76-b15","series-title":"J Esthet Restor Dent","first-page":"843","article-title":"Accuracy of different laboratory scanners for scanning of implant-supported full arch fixed prosthesis","volume":"34","author":"Ebeid","year":"2022","unstructured":"Ebeid K,\nNouh I,\nAshraf Y,\nCesar PF. Accuracy of different laboratory scanners for scanning of implant-supported full arch fixed prosthesis. J Esthet Restor Dent. 2022; 34:843\u2013848."},{"issue":"7","key":"i1548-1336-52-1-76-b16","series-title":"Dent J (Basel)","first-page":"75","article-title":"A comparison of full arch trueness and precision of nine intra-oral digital scanners and four lab digital scanners","volume":"9","author":"Nulty","year":"2021","unstructured":"Nulty AB. A comparison of full arch trueness and precision of nine intra-oral digital scanners and four lab digital scanners. Dent J (Basel). 2021;9(7):75."},{"key":"i1548-1336-52-1-76-b17","series-title":"J Dental Sci","first-page":"27","article-title":"In vitro comparison of trueness of three extraoral scanners","author":"Bilmeno\u011flu","year":"2021","unstructured":"Bilmeno\u011flu \u00c7.,\nBilgin T. In vitro comparison of trueness of three extraoral scanners. J Dental Sci. 2021;27."},{"key":"i1548-1336-52-1-76-b18","series-title":"J Prosthodont","first-page":"165","article-title":"Influence of implant scan body design (height, diameter, geometry, material, and retention system) on intraoral scanning accuracy: a systematic review","volume":"32","author":"G\u00f3mez-Polo","year":"2023","unstructured":"G\u00f3mez-Polo M,\nDonmez MB,\n\u00c7akmak G,\nYilmaz B,\nRevilla-Le\u00f3n M. Influence of implant scan body design (height, diameter, geometry, material, and retention system) on intraoral scanning accuracy: a systematic review. J Prosthodont. 2023;32:165\u2013180."},{"key":"i1548-1336-52-1-76-b19","series-title":"J Prosthet Dent","first-page":"119","article-title":"Influence of implant angulation and clinical implant scan body height on the accuracy of complete arch intraoral digital scans","volume":"131","author":"G\u00f3mez-Polo","year":"2024","unstructured":"G\u00f3mez-Polo M,\nSallorenzo A,\nOrtega R, et al. Influence of implant angulation and clinical implant scan body height on the accuracy of complete arch intraoral digital scans. J Prosthet Dent. 2024;131:119\u2013127."},{"key":"i1548-1336-52-1-76-b20","series-title":"J Prosthodont","first-page":"309","article-title":"Impact of different scan bodies and scan strategies on the accuracy of digital implant impressions assessed with an intraoral scanner: an in vitro study","volume":"29","author":"Motel","year":"2020","unstructured":"Motel C,\nKirchner E,\nAdler W,\nWichmann M,\nMatta RE. Impact of different scan bodies and scan strategies on the accuracy of digital implant impressions assessed with an intraoral scanner: an in vitro study. J Prosthodont. 2020;29:309\u2013314."},{"key":"i1548-1336-52-1-76-b21","series-title":"J Prosthet Dent","first-page":"186","article-title":"Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: a pilot study","volume":"111","author":"Andriessen","year":"2014","unstructured":"Andriessen FS,\nRijkens DR,\nvan der Meer WJ,\nWismeijer DW. Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: a pilot study. J Prosthet Dent. 2014;111:186\u2013194."},{"key":"i1548-1336-52-1-76-b22","series-title":"Int J Implant Dent","first-page":"18","article-title":"In vitro comparative analysis of scanning accuracy of intraoral and laboratory scanners in measuring the distance between multiple implants","volume":"8","author":"Natsubori","year":"2022","unstructured":"Natsubori R,\nFukazawa S,\nChiba T,\nTanabe N,\nKihara H,\nKondo H. In vitro comparative analysis of scanning accuracy of intraoral and laboratory scanners in measuring the distance between multiple implants. Int J Implant Dent. 2022;8:18."},{"key":"i1548-1336-52-1-76-b23","series-title":"J Dent","first-page":"105045","article-title":"Effect of different impression coping and scan body designs on the accuracy of conventional versus digital implant impressions: an in vitro study","volume":"146","author":"Alkindi","year":"2024","unstructured":"Alkindi S,\nHamdoon Z,\nAziz AM. Effect of different impression coping and scan body designs on the accuracy of conventional versus digital implant impressions: an in vitro study. J Dent. 2024;146:105045."},{"key":"i1548-1336-52-1-76-b24","series-title":"Clin Oral Investig","first-page":"72","article-title":"Evaluation of the influence of connection configuration on the implant-abutment interface vertical misfit of original milled titanium and laser-sintered cobalt-chromium abutments","volume":"29","author":"Diaz","year":"2025","unstructured":"Diaz P,\nVizoso B,\nLopez-Suarez C,\nGonzalo E,\nMosaddad SA,\nSuarez MJ. Evaluation of the influence of connection configuration on the implant-abutment interface vertical misfit of original milled titanium and laser-sintered cobalt-chromium abutments. Clin Oral Investig. 2025;29:72."},{"key":"i1548-1336-52-1-76-b25","series-title":"Sci Rep","first-page":"21892","article-title":"Trueness of digital implant impressions based on implant angulation and scan body materials","volume":"11","author":"Lee","year":"2021","unstructured":"Lee JH,\nBae JH,\nLee SY. Trueness of digital implant impressions based on implant angulation and scan body materials. Sci Rep. 2021;11:21892."},{"key":"i1548-1336-52-1-76-b26","series-title":"J Prosthodont Res","first-page":"128","article-title":"Influence of implant scanbody material, position and operator on the accuracy of digital impression for complete arch: a randomized in vitro trial","volume":"64","author":"Arcuri","year":"2020","unstructured":"Arcuri L,\nPozzi A,\nLio F,\nRompen E,\nZechner W,\nNardi A. Influence of implant scanbody material, position and operator on the accuracy of digital impression for complete arch: a randomized in vitro trial. J Prosthodont Res. 2020;64:128\u2013136."},{"key":"i1548-1336-52-1-76-b27","series-title":"Eur J Prosthodont Restor Dent","first-page":"305","article-title":"The accuracy of digital implant impressions when using and varying the material and diameter of the dental implant scan bodies","volume":"30","author":"Althubaitiy","year":"2022","unstructured":"Althubaitiy R,\nSambrook R,\nWeisbloom M,\nPetridis H. The accuracy of digital implant impressions when using and varying the material and diameter of the dental implant scan bodies. Eur J Prosthodont Restor Dent. 2022;30:305\u2013313."},{"key":"i1548-1336-52-1-76-b28","series-title":"J Oral Res Rev","first-page":"114","article-title":"Role of scan body material and shape on the accuracy of complete arch implant digitalization","volume":"14","author":"Karthhik","year":"2022","unstructured":"Karthhik R,\nRaj B,\nKarthikeyan BV. Role of scan body material and shape on the accuracy of complete arch implant digitalization. J Oral Res Rev. 2022;14:114\u2013120."},{"key":"i1548-1336-52-1-76-b29","series-title":"J Dent","first-page":"105336","article-title":"Effects of the intraoral scanner and implant library on the trueness of digital impressions in the full-arch implant scan: a comparative in vitro study","volume":"150","author":"Hauschild","year":"2024","unstructured":"Hauschild U,\nLerner H,\nWeigl P,\nPorr\u00e0 T,\nAdmakin O,\nMangano FG. Effects of the intraoral scanner and implant library on the trueness of digital impressions in the full-arch implant scan: a comparative in vitro study. J Dent. 2024;150:105336."},{"key":"i1548-1336-52-1-76-b30","series-title":"J Dent","first-page":"104641","article-title":"Accuracy of single-implant digital impression with various scanbody exposure levels at anterior and posterior regions","volume":"138","author":"Wu","year":"2023","unstructured":"Wu HK,\nChen G,\nHuang X,\nDeng F,\nLi Y. Accuracy of single-implant digital impression with various scanbody exposure levels at anterior and posterior regions. J Dent. 2023;138:104641."},{"key":"i1548-1336-52-1-76-b31","series-title":"Clin Oral Implants Res","first-page":"715","article-title":"Accuracy of digital versus conventional implant impressions","volume":"26","author":"Lee","year":"2015","unstructured":"Lee SJ,\nBetensky RA,\nGianneschi GE,\nGallucci GO. Accuracy of digital versus conventional implant impressions. Clin Oral Implants Res. 2015; 26:715\u2013719."},{"issue":"6","key":"i1548-1336-52-1-76-b32","series-title":"J Prosthet Dent","first-page":"749","article-title":"Accuracy in the digital workflow: From data acquisition to the digitally milled cast","volume":"115","author":"Koch","year":"2016","unstructured":"Koch GK,\nGallucci GO,\nLee SJ. Accuracy in the digital workflow: From data acquisition to the digitally milled cast. J Prosthet Dent. 2016;115(6):749\u2013754."},{"key":"i1548-1336-52-1-76-b33","series-title":"Med Sci Monit","first-page":"e943706","article-title":"Comparative accuracy of intraoral and extraoral digital workflows for short span implant supported fixed partial denture fabrication: an in vitro study","volume":"30","author":"Mansoor","year":"2024","unstructured":"Mansoor MA,\nSayed ME,\nAbdul HN, et al. Comparative accuracy of intraoral and extraoral digital workflows for short span implant supported fixed partial denture fabrication: an in vitro study. Med Sci Monit. 2024;30:e943706."},{"issue":"1","key":"i1548-1336-52-1-76-b34","series-title":"J Prosthet Dent","first-page":"96","article-title":"Accuracy of different digital scanning techniques and scan bodies for complete-arch implant-supported prostheses","volume":"123","author":"Mizumoto","year":"2020","unstructured":"Mizumoto RM,\nYilmaz B,\nMcGlumphy EA Jr,\nSeidt J,\nJohnston WM. Accuracy of different digital scanning techniques and scan bodies for complete-arch implant-supported prostheses. J Prosthet Dent. 2020;123(1):96\u2013104."},{"key":"i1548-1336-52-1-76-b35","series-title":"Mater (Basel)","first-page":"927","article-title":"Influence of implant scanbody wear on the accuracy of digital impression for complete-arch: a randomized in vitro trial","volume":"15","author":"Arcuri","year":"2022","unstructured":"Arcuri L,\nLio F,\nCampana V, et al. Influence of implant scanbody wear on the accuracy of digital impression for complete-arch: a randomized in vitro trial. Mater (Basel). 2022;15:927."},{"key":"i1548-1336-52-1-76-b36","series-title":"J Prosthodont","first-page":"419","article-title":"Effect of scanner type and scan body location on the accuracy of mandibular complete-arch digital implant scans: an in vitro study","volume":"31","author":"\u00c7akmak","year":"2022","unstructured":"\u00c7akmak G,\nYilmaz H,\nTrevi\u00f1o Santos A,\nK\u00f6kat AM,\nYilmaz B. Effect of scanner type and scan body location on the accuracy of mandibular complete-arch digital implant scans: an in vitro study. J Prosthodont. 2022;31:419\u2013426."},{"key":"i1548-1336-52-1-76-b37","series-title":"J Prosthet Dent","first-page":"617","article-title":"Computer-aided analysis of digital dental impressions obtained from intraoral and extraoral scanners","volume":"118","author":"Bohner","year":"2017","unstructured":"Bohner LOL,\nDe Luca Canto G,\nMarci\u00f3 BS,\nLagan\u00e1 DC,\nSesma N,\nTortamano Neto P. Computer-aided analysis of digital dental impressions obtained from intraoral and extraoral scanners. J Prosthet Dent. 2017;118:617\u2013623."},{"key":"i1548-1336-52-1-76-b38","series-title":"Mater (Basel)","first-page":"1744","article-title":"Effect of tooth types on the accuracy of dental 3d scanners: an in vitro study","volume":"13","author":"Son","year":"2020","unstructured":"Son K,\nLee KB. Effect of tooth types on the accuracy of dental 3d scanners: an in vitro study. Mater (Basel). 2020;13:1744."},{"key":"i1548-1336-52-1-76-b39","series-title":"BMC Oral Health","first-page":"101","article-title":"Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study","volume":"19","author":"Mangano","year":"2019","unstructured":"Mangano FG,\nHauschild U,\nVeronesi G,\nImburgia M,\nMangano C,\nAdmakin O. Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study. BMC Oral Health. 2019;19:101."},{"key":"i1548-1336-52-1-76-b40","series-title":"BMC Oral Health","first-page":"1033","article-title":"Evaluating the accuracy of CEREC intraoral scanners for inlay restorations: impact of adjacent tooth materials","volume":"24","author":"Kwon","year":"2024","unstructured":"Kwon Y,\nKim JH,\nPark JK,\nSon SA. Evaluating the accuracy of CEREC intraoral scanners for inlay restorations: impact of adjacent tooth materials. BMC Oral Health. 2024;24:1033."},{"key":"i1548-1336-52-1-76-b41","series-title":"J Prosthodont","first-page":"827","article-title":"Effect of using scan body accessories and inter-implant distances on the accuracy of complete arch implant digital impressions: an in vitro study","volume":"34","author":"Ashry","year":"2025","unstructured":"Ashry A,\nAbdelhamid AM,\nEzzelarab S,\nKhamis MM. Effect of using scan body accessories and inter-implant distances on the accuracy of complete arch implant digital impressions: an in vitro study. J Prosthodont. 2025;34:827\u2013835."},{"key":"i1548-1336-52-1-76-b42","series-title":"BMC Oral Health","first-page":"623","article-title":"Improved accuracy of digital implant impressions with newly designed scan bodies: an in vivo evaluation in beagle dogs","volume":"21","author":"Huang","year":"2021","unstructured":"Huang R,\nLiu Y,\nHuang B,\nZhou F,\nChen Z,\nLi Z. Improved accuracy of digital implant impressions with newly designed scan bodies: an in vivo evaluation in beagle dogs. BMC Oral Health. 2021;21:623."},{"key":"i1548-1336-52-1-76-b43","series-title":"Clin Oral Investig","first-page":"1249","article-title":"Digital impressions in dentistry-accuracy of impression digitalisation by desktop scanners","volume":"24","author":"Runkel","year":"2020","unstructured":"Runkel C,\nG\u00fcth JF,\nErdelt K,\nKeul C. Digital impressions in dentistry-accuracy of impression digitalisation by desktop scanners. Clin Oral Investig. 2020;24:1249\u20131257."},{"key":"i1548-1336-52-1-76-b44","article-title":"Dentistry-Digitizing devices for CAD\/CAM systems for indirect dental restorations-Test methods for assessing accuracy","author":"International Organization for Standardization","year":"2012","unstructured":"International Organization for Standardization. ISO\/TR 12836: Dentistry-Digitizing devices for CAD\/CAM systems for indirect dental restorations-Test methods for assessing accuracy; 2012."}],"container-title":["Journal of Oral Implantology"],"original-title":[],"link":[{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/52\/1\/article-p76.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/52\/1\/article-p76.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/52\/1\/article-p76.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T00:31:29Z","timestamp":1783729889000},"score":1,"resource":{"primary":{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/52\/1\/article-p76.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2]]},"references-count":44,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.1563\/aaid-joi-d-25-00133","relation":{},"ISSN":["1548-1336","0160-6972"],"issn-type":[{"value":"1548-1336","type":"electronic"},{"value":"0160-6972","type":"print"}],"subject":[],"published":{"date-parts":[[2026,2]]}}}