{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,3]],"date-time":"2026-05-03T14:42:59Z","timestamp":1777819379379,"version":"3.51.4"},"reference-count":31,"publisher":"International Society of Endovascular Specialists","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Endovascular Therapy"],"published-print":{"date-parts":[[2005,10]]},"DOI":"10.1583\/05-1615r.1","type":"journal-article","created":{"date-parts":[[2005,10,7]],"date-time":"2005-10-07T11:15:54Z","timestamp":1128683754000},"page":"538-547","source":"Crossref","is-referenced-by-count":27,"title":["<b>Procedure-Related Complications and Early Neurological Adverse Events of Unprotected and Protected Carotid Stenting:<\/b>\n                    Temporal Trends in a Consecutive Patient Series"],"prefix":"10.1583","volume":"12","author":[{"given":"Johanna","family":"Boltuch","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Schila","family":"Sabeti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jasmin","family":"Amighi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Petra","family":"Dick","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wolfgang","family":"Mlekusch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oliver","family":"Schlager","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ali","family":"Ahmadi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Erich","family":"Minar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin","family":"Schillinger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"527","reference":[{"key":"i1545-1550-12-5-538-b1","doi-asserted-by":"crossref","unstructured":"J. S. Yadav, M. H. Wholey, and R. E. Kuntz .et al.Protected carotid-artery stenting versus endarterectomy in high-risk patients., N Engl J Med, 2004 .351 :1493 \u20131501 .","DOI":"10.1056\/NEJMoa040127"},{"key":"i1545-1550-12-5-538-b2","doi-asserted-by":"crossref","unstructured":"M. H. Wholey, M. Wholey, and K. Mathias .et al.Global experience in cervical carotid artery stent placement., Catheter Cardiovasc Interv, 2000 .50 :160 \u2013167 .","DOI":"10.1002\/(SICI)1522-726X(200006)50:2<160::AID-CCD2>3.0.CO;2-E"},{"key":"i1545-1550-12-5-538-b3","doi-asserted-by":"crossref","unstructured":"R. Ahmadi, A. Willfort, and W. Lang .et al.Carotid artery stenting: effect of learning curve and intermediate-term morphological outcome., J Endovasc Ther, 2001 .8 :539 \u2013546 .","DOI":"10.1177\/152660280100800601"},{"key":"i1545-1550-12-5-538-b4","doi-asserted-by":"crossref","unstructured":"R. Ahmadi, M. Schillinger, and W. Lang .et al.Carotid artery stenting in older patients: is age a risk factor for poor outcome? J Endovasc Ther, 2002 .9 :559 \u2013565 .","DOI":"10.1177\/152660280200900501"},{"key":"i1545-1550-12-5-538-b5","doi-asserted-by":"crossref","unstructured":"W. Mlekusch, M. Schillinger, and S. Sabeti .et al.Hypotension and bradycardia after elective carotid stenting: frequency and risk factors., J Endovasc Ther, 2003 .10 :851 \u2013859 .","DOI":"10.1177\/152660280301000501"},{"key":"i1545-1550-12-5-538-b6","doi-asserted-by":"crossref","unstructured":"S. Sabeti, M. Schillinger, and W. Mlekusch .et al.Contralateral high grade carotid artery stenosis or occlusion is not associated with an increased risk for poor neurological outcome after carotid stenting., Radiology, 2004 .230 :70 \u201376 .","DOI":"10.1148\/radiol.2301021371"},{"key":"i1545-1550-12-5-538-b7","doi-asserted-by":"crossref","unstructured":"M. Schillinger, M. Exner, and W. Mlekusch .et al.Acute phase response after carotid stenting: association with 6 months in-stent restenosis., Radiology, 2003 .227 :516 \u2013521 .","DOI":"10.1148\/radiol.2272020183"},{"key":"i1545-1550-12-5-538-b8","doi-asserted-by":"crossref","unstructured":"G. S. Roubin, G. New, and S. S. Iyer .et al.Immediate and late clinical outcomes of carotid artery stenting in patients with symptomatic and asymptomatic carotid artery stenosis: a 5 year prospective analysis., Circulation, 2001 .103 :532 \u2013537 .","DOI":"10.1161\/01.CIR.103.4.532"},{"key":"i1545-1550-12-5-538-b9","doi-asserted-by":"crossref","unstructured":"A. Kastrup, K. Groschel, and H. Krapf .et al.Early outcome of carotid angioplasty and stenting with and without cerebral protection devices: a systematic review of the literature., Stroke, 2003 .34 :813 \u2013819 .","DOI":"10.1161\/01.STR.0000058160.53040.5F"},{"key":"i1545-1550-12-5-538-b10","doi-asserted-by":"crossref","unstructured":"W. H. Brooks, R. R. McClure, and M. R. Jones .et al.Carotid angioplasty and stenting versus carotid endarterectomy: randomized trial in a community hospital., J Am Coll Cardiol, 2001 .38 :1589 \u20131595 .","DOI":"10.1016\/S0735-1097(01)01595-9"},{"key":"i1545-1550-12-5-538-b11","doi-asserted-by":"crossref","unstructured":"Endovascular versus surgical treatment in patients with carotid stenosis in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): a randomised trial., Lancet, 2001 .357 :1729 \u20131737 .","DOI":"10.1016\/S0140-6736(00)04893-5"},{"key":"i1545-1550-12-5-538-b12","doi-asserted-by":"crossref","unstructured":"T. Ohki, G. S. Roubin, and F. J. Veith .et al.Efficacy of a filter device in the prevention of embolic events during carotid angioplasty and stenting: an ex vivo analysis., J Vasc Surg, 1999 .30 :1034 \u20131044 .","DOI":"10.1016\/S0741-5214(99)70041-8"},{"key":"i1545-1550-12-5-538-b13","doi-asserted-by":"crossref","unstructured":"S. M\u00fcller-H\u00fclsbeck, T. Jahnke, and C. Liess .et al.Comparison of various cerebral protection devices used for carotid artery stent placement: an in vitro experiment., J Vasc Interv Radiol, 2003 .14 :613 \u2013620 .","DOI":"10.1097\/01.RVI.0000064857.87207.57"},{"key":"i1545-1550-12-5-538-b14","doi-asserted-by":"crossref","unstructured":"A. Angelini, B. Reimers, and M. Della Barbera .et al.Cerebral protection during carotid artery stenting. Collection and histopathologic analysis of embolized debris., Stroke, 2002 .33 :456 \u2013461 .","DOI":"10.1161\/hs0202.102337"},{"key":"i1545-1550-12-5-538-b15","doi-asserted-by":"crossref","unstructured":"N. Al-Mubarak, G. Roubin, and J. Vitek .et al.Effect of distal-balloon protection system on microembolization during carotid stenting., Circulation, 2001 .104 :1999 \u20132002 .","DOI":"10.1161\/hc4201.099224"},{"key":"i1545-1550-12-5-538-b16","doi-asserted-by":"crossref","unstructured":"A. Schmidt, K. W. Diederich, and S. Scheinert .et al.Effect of two different neuroprotection systems on microembolization during carotid artery stenting., J Am Coll Cardiol, 2004 .44 :1966 \u20131969 .","DOI":"10.1016\/j.jacc.2004.08.049"},{"key":"i1545-1550-12-5-538-b17","doi-asserted-by":"crossref","unstructured":"A. Cremonesi, R. Manetti, and C. Setacci .et al.Protected carotid stenting. Clinical advantages and complications of embolic protection devices in 442 consecutive patients., Stroke, 2003 .34 :1936 \u20131943 .","DOI":"10.1161\/01.STR.0000081000.23561.61"},{"key":"i1545-1550-12-5-538-b18","doi-asserted-by":"crossref","unstructured":"P. Cardaioli, M. Giordan, and M. Panfili .et al.Complication with an embolic protection device during carotid angioplasty., Catheter Cardiovasc Interv, 2004 .62 :234 \u2013236 .","DOI":"10.1002\/ccd.20061"},{"key":"i1545-1550-12-5-538-b19","doi-asserted-by":"crossref","unstructured":"J. A. Vos, J. C. van den Berg, and S. M. Ernst .et al.Carotid angioplasty and stent placement: comparison of transcranial Doppler US data and clinical outcome with and without filtering cerebral protection devices in 509 patients., Radiology, 2005 .234 :493 \u2013499 .","DOI":"10.1148\/radiol.2342040119"},{"key":"i1545-1550-12-5-538-b20","doi-asserted-by":"crossref","unstructured":"W. Theiss, P. Hermanek, and K. Mathias .et al.Pro-CAS. A prospective registry of carotid angioplasty and stenting., Stroke, 2004 .35 :2134 \u20132139 .","DOI":"10.1161\/01.STR.0000135763.62131.6a"},{"key":"i1545-1550-12-5-538-b21","doi-asserted-by":"crossref","unstructured":"S. Sabeti, M. Schillinger, and W. Mlekusch .et al.Duplex sonography for quantification of internal carotid artery stenosis\u2014a comparative analysis of different flow velocity thresholds., Radiology, 2004 .232 :431 \u2013439 .","DOI":"10.1148\/radiol.2321030791"},{"key":"i1545-1550-12-5-538-b22","doi-asserted-by":"crossref","unstructured":"C. Sherif, P. Dick, and S. Sabeti .et al.Neurological outcome of conservative versus endovascular treatment of patients with asymptomatic high-grade carotid artery stenosis: a propensity score\u2013adjusted analysis., J Endovasc Ther, 2005 .12 :145 \u2013155 .","DOI":"10.1583\/04-1452R.1"},{"key":"i1545-1550-12-5-538-b23","doi-asserted-by":"crossref","unstructured":"M. Schillinger, M. Exner, and J. Amighi .et al.Joint effects of C-reactive protein and glycated hemoglobin in predicting future cardiovascular events in patients with advanced atherosclerosis., Circulation, 2003 .108 :2323 \u20132328 .","DOI":"10.1161\/01.CIR.0000095267.24234.00"},{"key":"i1545-1550-12-5-538-b24","doi-asserted-by":"crossref","unstructured":"M. Schillinger, M. Exner, and W. Mlekusch .et al.Inflammation and carotid artery risk for atherosclerosis study (ICARAS)., Circulation, 2005 .111 :2203 \u20132209 .","DOI":"10.1161\/01.CIR.0000163569.97918.C0"},{"key":"i1545-1550-12-5-538-b25","doi-asserted-by":"crossref","unstructured":"T. Brott, H. P. Adams, and C. P. Olinger .et al.Measurements of acute cerebral infarction: a clinical examination scale., Stroke, 1989 .20 :864 \u2013870 .","DOI":"10.1161\/01.STR.20.7.864"},{"key":"i1545-1550-12-5-538-b26","doi-asserted-by":"crossref","unstructured":"A. Halliday, A. Mansfield, and J. Marro .et al.Prevention of disabling and fatal strokes by successful carotid endarterectomy in patients without recent neurological symptoms: randomised controlled trial., Lancet, 2004 .363 :1491 \u20131502 .","DOI":"10.1016\/S0140-6736(04)16146-1"},{"key":"i1545-1550-12-5-538-b27","unstructured":"J. B. Martin, P. Gailloud, and H. G. Khan .et al.Distal flow protection during carotid stenting, a prospective study to quantify the embolic debris retrieved in the internal carotid artery territory., Cardiovasc Intervent Radiol, 1998 .21, Suppl 1 :88 ."},{"key":"i1545-1550-12-5-538-b28","doi-asserted-by":"crossref","unstructured":"K. W. Diederich, D. Scheinert, and A. Schmidt .et al.First clinical experiences with an endovascular clamping system for neuroprotection during carotid stenting., Eur J Vasc Endovasc Surg, 2004 .28 :629 \u2013633 .","DOI":"10.1016\/j.ejvs.2004.08.012"},{"key":"i1545-1550-12-5-538-b29","doi-asserted-by":"crossref","unstructured":"L. K. Sztriha, E. V\u00f6r\u00f6s, and K. Sas .et al.Favorable early outcome of carotid artery stenting without protection devices., Stroke, 2004 .35 :2862 \u20132866 .","DOI":"10.1161\/01.STR.0000147714.19871.45"},{"key":"i1545-1550-12-5-538-b30","doi-asserted-by":"crossref","unstructured":"S. M\u00fcller-H\u00fclsbeck, T. Jahnke, and P. Stolzmann .et al.A new concept for covered stent protected carotid angioplasty: an ex vivo study., Rofo, 2003 .175 :1634 \u20131638 .","DOI":"10.1055\/s-2003-45342"},{"key":"i1545-1550-12-5-538-b31","doi-asserted-by":"crossref","unstructured":"S. M\u00fcller-H\u00fclsbeck, E. J. Husler, and S. R. Schaffner .et al.An in vitro analysis of a carotid artery stent with a protective membrane., J Vasc Interv Radiol, 2004 .15 :1295 \u20131305 .","DOI":"10.1097\/01.RVI.0000141339.79538.0D"}],"container-title":["Journal of Endovascular Therapy"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T21:27:47Z","timestamp":1777498067000},"score":1,"resource":{"primary":{"URL":"http:\/\/jet.sagepub.com\/lookup\/doi\/10.1583\/05-1615R.1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,10]]},"references-count":31,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2005,10]]}},"alternative-id":["10.1583\/05-1615R.1"],"URL":"https:\/\/doi.org\/10.1583\/05-1615r.1","relation":{},"ISSN":["1526-6028","1545-1550"],"issn-type":[{"value":"1526-6028","type":"print"},{"value":"1545-1550","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,10]]}}}