{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,10]],"date-time":"2025-05-10T04:10:02Z","timestamp":1746850202024,"version":"3.40.5"},"reference-count":30,"publisher":"Institute of Electronics, Information and Communications Engineers (IEICE)","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEICE Electron. Express"],"published-print":{"date-parts":[[2025,5,10]]},"DOI":"10.1587\/elex.22.20240614","type":"journal-article","created":{"date-parts":[[2025,3,23]],"date-time":"2025-03-23T22:06:47Z","timestamp":1742767607000},"page":"20240614-20240614","source":"Crossref","is-referenced-by-count":0,"title":["Research on wireless powered squirrel cage system based on temporally interference low frequency envelope electrical stimulation"],"prefix":"10.1587","volume":"22","author":[{"given":"Xinsheng","family":"Yang","sequence":"first","affiliation":[{"name":"Dept. of Electrical Engineering, the State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Hebei University of Technology"},{"name":"Postdoctoral Workstation of Tianjin Tianzhong Yimai Technology Development Co., Ltd"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haopeng","family":"Zhang","sequence":"additional","affiliation":[{"name":"Dept. of Electrical Engineering, the State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Hebei University of Technology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tingyu","family":"Wang","sequence":"additional","affiliation":[{"name":"Dept. of Electrical Engineering, the State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Hebei University of Technology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jintao","family":"Zhao","sequence":"additional","affiliation":[{"name":"Dept. of Electrical Engineering, the State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Hebei University of Technology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xu","family":"Zhang","sequence":"additional","affiliation":[{"name":"Dept. of Electrical Engineering, the State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Hebei University of Technology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guizhi","family":"Xu","sequence":"additional","affiliation":[{"name":"Dept. of Electrical Engineering, the State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Hebei University of Technology"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"532","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"[1] J. Buwembo, <i>et al<\/i>.: \u201cDirect sciatic nerve electrical stimulation for complex regional pain syndrome type 1,\u201d Neuromodulation: Technology at the Neural Interface <b>24<\/b> (2021) 1075 (DOI: 10.1111\/ner.13294).","DOI":"10.1111\/ner.13294"},{"key":"2","doi-asserted-by":"crossref","unstructured":"[2] A.-M. Pion, <i>et al<\/i>.: \u201cTranscutaneous and direct electrical stimulation of mouse sciatic nerve accelerates functional recovery after nerve transection and immediate repair,\u201d Ann. Plas. Surg. <b>90<\/b> (2023) 237 (DOI: 10.1097\/sap.0000000000003463).","DOI":"10.1097\/SAP.0000000000003463"},{"key":"3","doi-asserted-by":"crossref","unstructured":"[3] C. Calvey, <i>et al.<\/i>, \u201cShort-term electrical stimulation to promote nerve repair and functional recovery in a rat model,\u201d The Journal of Hand Surgery <b>40<\/b> (2015) 314 (DOI: 10.1016\/j.jhsa.2014.10.002).","DOI":"10.1016\/j.jhsa.2014.10.002"},{"key":"4","doi-asserted-by":"crossref","unstructured":"[4] X. Lv, <i>et al<\/i>.: \u201cActivation of the primary motor cortex using fully-implanted electrical sciatic nerve stimulation,\u201d Experimental and Therapeutic Medicine <b>8<\/b> (2019) 3357 (DOI: 10.3892\/etm.2019.7993).","DOI":"10.3892\/etm.2019.7993"},{"key":"5","doi-asserted-by":"crossref","unstructured":"[5] S.M. Won, <i>et al<\/i>.: \u201cEmerging modalities and implantable technologies for neuromodulation,\u201d Cell <b>181<\/b> (2020) 115 (DOI: 10.1016\/j.cell.2020.02.054).","DOI":"10.1016\/j.cell.2020.02.054"},{"key":"6","doi-asserted-by":"crossref","unstructured":"[6] S.A. Mirbozorgi, <i>et al<\/i>.: \u201cA wirelessly-powered homecage with segmented copper foils and closed-loop power control,\u201d IEEE Trans. Biomed. Circuits Syst. <b>10<\/b> (2016) 979 (DOI: 10.1109\/TBCAS.2016.2577705).","DOI":"10.1109\/TBCAS.2016.2577705"},{"key":"7","doi-asserted-by":"crossref","unstructured":"[7] B. Lee, <i>et al<\/i>.: \u201cAn inductively-powered wireless neural recording and stimulation system for freely-behaving animals,\u201d IEEE Trans. Biomed. Circuits Syst. <b>13<\/b> (2019) 413 (DOI: 10.1109\/tbcas.2019.2891303).","DOI":"10.1109\/TBCAS.2019.2891303"},{"key":"8","unstructured":"[8] S. Zhang, <i>et al<\/i>.: \u201cSimulation and analysis of discharge activity of transcranial magnetoacoustic stimulation neuralnetwork based on cortical neuron model,\u201d Trans. China Electrotechnical Society <b>36<\/b> (2021) 3851."},{"key":"9","doi-asserted-by":"crossref","unstructured":"[9] R. Das, <i>et al<\/i>.: \u201cBiointegrated and wirelessly powered implantable brain devices: a review,\u201d IEEE Trans. Biomed. Circuits Syst. <b>14<\/b> (2020) 343 (DOI: 10.1109\/tbcas.2020.2966920).","DOI":"10.1109\/TBCAS.2020.2966920"},{"key":"10","unstructured":"[10] Q. Yang, <i>et al<\/i>.: \u201cKey basis and technical bottleneck of wirless power transfer technology,\u201d Trans. China Electrotechnical Society <b>30<\/b> (2015) 1."},{"key":"11","doi-asserted-by":"crossref","unstructured":"[11] D.K. Biswas, <i>et al<\/i>.: \u201cSemi-implantable wireless power transfer (WPT) system integrated with on-chip power management unit (PMU) for neuromodulation application,\u201d IEEE J. Electromagn. RF Microw. Med. Biol. <b>7<\/b> (2023) 193 (DOI: 10.1109\/jerm.2023.3256705).","DOI":"10.1109\/JERM.2023.3256705"},{"key":"12","doi-asserted-by":"crossref","unstructured":"[12] V. Ramakrishnan, <i>et al<\/i>.: \u201cA comprehensive review on efficiency enhancement of wireless charging system for an electric vehicles application,\u201d IEEE Access <b>12<\/b> (2024) 46967 (DOI: 10.1109\/access.2024.3378303).","DOI":"10.1109\/ACCESS.2024.3378303"},{"key":"13","doi-asserted-by":"crossref","unstructured":"[13] B. Clerckx, <i>et al<\/i>.: \u201cFoundations of wireless information and power transfer: theory, prototypes, and experiments,\u201d Proc. IEEE <b>110<\/b> (2022) 8 (DOI: 10.1109\/jproc.2021.3132369).","DOI":"10.1109\/JPROC.2021.3132369"},{"key":"14","doi-asserted-by":"crossref","unstructured":"[14] Y. Jia, <i>et al<\/i>.: \u201cA mm-sized free-floating wirelessly powered implantable optical stimulation device,\u201d IEEE Trans. Biomed. Circuits Syst. <b>13<\/b> (2019) 608 (DOI: 10.1109\/tbcas.2019.2918761).","DOI":"10.1109\/TBCAS.2019.2918761"},{"key":"15","doi-asserted-by":"crossref","unstructured":"[15] Y. Jia, <i>et al<\/i>.: \u201cA mm-sized free-floating wireless implantable opto-electro stimulation device,\u201d Micromachines <b>11<\/b> (2020) 621 (DOI: 10.3390\/mi11060621).","DOI":"10.3390\/mi11060621"},{"key":"16","doi-asserted-by":"crossref","unstructured":"[16] Y. Jia, <i>et al<\/i>.: \u201cA dual-band wireless power transmission system for evaluating mm-sized implants,\u201d IEEE Trans. Biomed. Circuits Syst. <b>13<\/b> (2019) 595 (DOI: 10.1109\/tbcas.2019.2915649).","DOI":"10.1109\/TBCAS.2019.2915649"},{"key":"17","doi-asserted-by":"crossref","unstructured":"[17] B. Hutcheon and Y. Yarom: \u201cResonance, oscillation and the intrinsic frequency preferences of neurons,\u201d Trends Neurosci. <b>23<\/b> (2000) 216 (DOI: 10.1016\/s0166-2236(00)01547-2).","DOI":"10.1016\/S0166-2236(00)01547-2"},{"key":"18","doi-asserted-by":"crossref","unstructured":"[18] S.L. Thompson, <i>et al<\/i>.: \u201cA review of parameter settings for invasive and non-invasive vagus nerve stimulation (VNS) applied in neurological and psychiatric disorders,\u201d <b>15<\/b> Frontiers in Neuroscience (2021) 709436 (DOI: 10.3389\/fnins.2021.709436).","DOI":"10.3389\/fnins.2021.709436"},{"key":"19","doi-asserted-by":"crossref","unstructured":"[19] C.A. Edwards, <i>et al<\/i>.: \u201cNeurostimulation devices for the treatment of neurologic disorders,\u201d Mayo Clinic Proceedings <b>92<\/b> (2017) 1427 (DOI: 10.1016\/j.mayocp.2017.05.005).","DOI":"10.1016\/j.mayocp.2017.05.005"},{"key":"20","doi-asserted-by":"crossref","unstructured":"[20] L.Y. Kamel, <i>et al<\/i>.: \u201cVagus nerve stimulation: An update on a novel treatment for treatment-resistant depression,\u201d J. Neurol. Sci. <b>434<\/b> (2022) 120171 (DOI: 10.1016\/j.jns.2022.120171).","DOI":"10.1016\/j.jns.2022.120171"},{"key":"21","doi-asserted-by":"crossref","unstructured":"[21] T.S. Pham, <i>et al<\/i>.: \u201cOptimal frequency for magnetic resonant wireless power transfer in conducting medium,\u201d Sci. Rep. <b>11<\/b> (2021) 18690 (DOI: 10.1038\/s41598-021-98153-y).","DOI":"10.1038\/s41598-021-98153-y"},{"key":"22","doi-asserted-by":"crossref","unstructured":"[22] R. Chen, <i>et al<\/i>.: \u201cWireless magnetothermal deep brain stimulation,\u201d Science <b>347<\/b> (2015) 1477 (DOI: 10.1126\/science.1261821).","DOI":"10.1126\/science.1261821"},{"key":"23","doi-asserted-by":"crossref","unstructured":"[23] J. Zhao and Y. Gao, \u201cA 13.56\u2006MHz wireless power transfer system with bidirectional data link and closed-loop power control for implantable neuromuscular stimulator,\u201d 2019 IEEE Asia-Pacific Microwave Conference (APMC) (2019) 1002 (DOI: 10.1109\/APMC46564.2019.9038634).","DOI":"10.1109\/APMC46564.2019.9038634"},{"key":"24","doi-asserted-by":"crossref","unstructured":"[24] A. Khalifa, <i>et al<\/i>.: \u201cMagnetic temporal interference for noninvasive and focal brain stimulation,\u201d J. Neural Eng. <b>20<\/b> (2023) 016002 (DOI: 10.1088\/1741-2552\/acb015).","DOI":"10.1088\/1741-2552\/acb015"},{"key":"25","doi-asserted-by":"crossref","unstructured":"[25] B. Lee, <i>et al<\/i>.: \u201cAn implantable peripheral nerve recording and stimulation system for experiments on freely moving animal subjects,\u201d Sci. Rep. <b>8<\/b> (2018) 6115 (DOI: 10.1038\/s41598-018-24465-1).","DOI":"10.1038\/s41598-018-24465-1"},{"key":"26","doi-asserted-by":"crossref","unstructured":"[26] Y. Jia, <i>et al<\/i>.: \u201cA trimodal wireless implantable neural interface system-on-chip,\u201d IEEE Trans. Biomed. Circuits Syst. <b>14<\/b> (2020) 1207 (DOI: 10.1109\/tbcas.2020.3037452).","DOI":"10.1109\/TBCAS.2020.3037452"},{"key":"27","doi-asserted-by":"crossref","unstructured":"[27] C. Jiang, <i>et al<\/i>.: \u201cHelmholtz coils based WPT coupling analysis of temporal interference electrical stimulation system,\u201d Applied Sciences <b>12<\/b> (2022) 9832 (DOI: 10.3390\/app12199832).","DOI":"10.3390\/app12199832"},{"key":"28","doi-asserted-by":"crossref","unstructured":"[28] L. Yang, <i>et al<\/i>.: \u201cA high-efficiency integrated LCC\/S WPT system with constant current output,\u201d IEEE J. Emerg. Sel. Topics Power Electron. <b>12<\/b> (2024) 341 (DOI: 10.1109\/pedes49360.2020.9379367).","DOI":"10.1109\/JESTPE.2023.3290214"},{"key":"29","doi-asserted-by":"crossref","unstructured":"[29] F. Xia, <i>et al<\/i>.: \u201cMinimally invasive hypoglossal nerve stimulator enabled by ECG sensor and WPT to manage obstructive sleep apnea,\u201d Sensors <b>23<\/b> (2023) 8882 (DOI: 10.3390\/s23218882).","DOI":"10.3390\/s23218882"},{"key":"30","doi-asserted-by":"crossref","unstructured":"[30] M. Wu, <i>et al<\/i>.: \u201cAn efficiency optimization method for the multiple coils WPT system against the pad misalignment,\u201d IEEE Trans. Transp. Electrific. <b>11<\/b> (2025) 1743 (DOI: 10.1109\/tte.2024.3410676).","DOI":"10.1109\/TTE.2024.3410676"}],"container-title":["IEICE Electronics Express"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/elex\/22\/9\/22_22.20240614\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,10]],"date-time":"2025-05-10T03:53:29Z","timestamp":1746849209000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/elex\/22\/9\/22_22.20240614\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,10]]},"references-count":30,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1587\/elex.22.20240614","relation":{},"ISSN":["1349-2543"],"issn-type":[{"type":"electronic","value":"1349-2543"}],"subject":[],"published":{"date-parts":[[2025,5,10]]},"article-number":"22.20240614"}}