{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,6]],"date-time":"2025-12-06T05:01:45Z","timestamp":1764997305255},"reference-count":10,"publisher":"Institute of Electronics, Information and Communications Engineers (IEICE)","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEICE Trans. Electron."],"published-print":{"date-parts":[[2020,12,1]]},"DOI":"10.1587\/transele.2020emp0001","type":"journal-article","created":{"date-parts":[[2020,7,2]],"date-time":"2020-07-02T22:06:27Z","timestamp":1593727587000},"page":"698-704","source":"Crossref","is-referenced-by-count":4,"title":["Arc Length Just Before Extinction of Break Arcs Magnetically Blown-Out by an Appropriately Placed Permanent Magnet in a 200V-500VDC\/10A Resistive Circuit"],"prefix":"10.1587","volume":"E103.C","author":[{"given":"Yuta","family":"KANEKO","sequence":"first","affiliation":[{"name":"Shizuoka University"}]},{"given":"Junya","family":"SEKIKAWA","sequence":"additional","affiliation":[{"name":"Shizuoka University"}]}],"member":"532","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"[1] R. Holm, Electric Contacts, 4th ed., Springer-Verlag, Berlin, pp.275-286, 1967.","DOI":"10.1007\/978-3-662-06688-1_51"},{"key":"2","unstructured":"[2] P.G. Slade, \u201cElectrical Contacts: Principles and Applications, Second Edition,\u201d CRC Press 2014, pp.588-592, 2014."},{"key":"3","doi-asserted-by":"crossref","unstructured":"[3] H. Liang, D. Liu, X. Zhou, X. Liao, D. Chen, Z. Cai, and S. Chen, \u201cArc Behaviors of Three Kinds of Bridge-type Contacts when Opening a Resistive Load in Range of from 300VDC to 750VDC,\u201d Proc. of IEEE Holm Conf. on Electrical Contacts, pp.81-86, Oct. 2018. 10.1109\/holm.2018.8611658","DOI":"10.1109\/HOLM.2018.8611658"},{"key":"4","doi-asserted-by":"crossref","unstructured":"[4] K. Yoshida, K. Sawa, and K. Suzuki, \u201cInfluence of Magnetic Flex Density on \u201cMagnetic Blow-out\u201d of Direct Current High Voltage Arc,\u201d Proc. of IEEE Holm Conf. on Electrical Contacts, pp.189-194, Oct. 2018. 10.1109\/holm.2018.8611775","DOI":"10.1109\/HOLM.2018.8611775"},{"key":"5","doi-asserted-by":"publisher","unstructured":"[5] H. Ono, J. Sekikawa, and T. Kubono, \u201cArc Duration of Break Arcs Magnetically Blown-Out in a DC 450V Resistive Circuit,\u201d IEICE Trans. Electron., vol.E95-C, no.9, pp.1515-1521, Sept. 2012. 10.1587\/transele.e95.c.1515","DOI":"10.1587\/transele.E95.C.1515"},{"key":"6","doi-asserted-by":"publisher","unstructured":"[6] K. Sawa, M. Tsuruoka, and M. Morii, \u201cFundamental Characteristics of Arc Extinction at DC Low Current Interruption with High Voltage (&lt;500V),\u201d IEICE Trans. Electron., vol.E99-C, no.9, pp.1016-1022, Sept. 2016. 10.1587\/transele.e99.c.1016","DOI":"10.1587\/transele.E99.C.1016"},{"key":"7","unstructured":"[7] Y. Kaneko and J. Sekikawa, \u201cArc length at arc extinction of break arcs when a 500VDC\/10A High Voltage resistive circuit is interrupted,\u201d IEICE Technical Report, vol.118, no.41, pp.33-37, May 2018."},{"key":"8","unstructured":"[8] Y. Kaneko and J. Sekikawa, \u201cInfluence of width of magnets on shape of break arcs magnetically blown-out in a 500VDC\/10A resistive circuit,\u201d IEICE Technical Report, vol.118, no.446, pp.7-12, Feb. 2019."},{"key":"9","unstructured":"[9] J. Sekikawa and T. Kubono, \u201cObservation of Breaking Arcs of Ag or Cu Electrical Contact Pairs with a High-Speed camera,\u201d IEICE Trans. Electron., vol.E87-C, no.8, pp.1342-1347, Aug. 2004."},{"key":"10","doi-asserted-by":"publisher","unstructured":"[10] K. Kato and J. Sekikawa, \u201cRestriction on Motion of Break Arcs Magnetically Blown-out by Surrounding Walls in a 450VDC\/10A Resistive Circuit,\u201d IEICE Trans. Electron., vol.E99-C, no.9, pp.1009-1015, Sept. 2016. 10.1587\/transele.e99.c.1009","DOI":"10.1587\/transele.E99.C.1009"}],"container-title":["IEICE Transactions on Electronics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/transele\/E103.C\/12\/E103.C_2020EMP0001\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,12,5]],"date-time":"2020-12-05T03:15:08Z","timestamp":1607138108000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/transele\/E103.C\/12\/E103.C_2020EMP0001\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12,1]]},"references-count":10,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1587\/transele.2020emp0001","relation":{},"ISSN":["0916-8524","1745-1353"],"issn-type":[{"value":"0916-8524","type":"print"},{"value":"1745-1353","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,12,1]]}}}