{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,4]],"date-time":"2026-04-04T04:45:04Z","timestamp":1775277904957,"version":"3.50.1"},"reference-count":31,"publisher":"Institute of Electronics, Information and Communications Engineers (IEICE)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEICE Trans. Electron."],"published-print":{"date-parts":[[2026,4,1]]},"DOI":"10.1587\/transele.2025ecp5050","type":"journal-article","created":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T22:08:31Z","timestamp":1759961311000},"page":"139-148","source":"Crossref","is-referenced-by-count":0,"title":["Ridged Waveguides for Use in Microwave Surgical Energy Devices"],"prefix":"10.1587","volume":"E109.C","author":[{"given":"Tsugumi","family":"NISHIDATE","sequence":"first","affiliation":[{"name":"Graduate School of Science and Engineering, Chiba University"}]},{"given":"Kazuyuki","family":"SAITO","sequence":"additional","affiliation":[{"name":"Center for Frontier Medical Engineering, Chiba University"}]},{"given":"Nobuyoshi","family":"TAKESHITA","sequence":"additional","affiliation":[{"name":"National Cancer Center Hospital East"}]}],"member":"532","reference":[{"key":"1","doi-asserted-by":"publisher","unstructured":"[1] T. Tani, S. Naka, S. Tani, H. Shiomi, K. Murakami, A. Yamada, and D.T. Khiem, \u201cThe invention of microwave surgical scissors for seamless coagulation and cutting,\u201d Surg. Today, vol.48, no.9, pp.856-864, Sept. 2018. DOI:10.1007\/s00595-018-1662-7 10.1007\/s00595-018-1662-7","DOI":"10.1007\/s00595-018-1662-7"},{"key":"2","unstructured":"[2] N.Q. Vinh, T. Tani, S. Naka, and S. Tani, \u201cComparison of tissue changes caused by microwave and radio frequency energy in an experimental liver ablation,\u201d Int. J. Clin. Exp. Pathol., vol.9, no.2, pp.1294-1302, Feb. 2016."},{"key":"3","doi-asserted-by":"publisher","unstructured":"[3] K. Takebayashi, H. Shiomi, S. Naka, H. Murayama, K. Murakami, H. Akabori, T. Yamaguchi, T. Shimizu, S. Murata, H. Yamamoto, Y. Kurumi, and T. Tani, \u201cUtility of a microwave surgical instrument in sealing lymphatic vessels,\u201d Am. J. Surg., vol.206, no.2, pp.229-233, Aug. 2013. DOI:10.1016\/j.amjsurg.2012.07.048 10.1016\/j.amjsurg.2012.07.048","DOI":"10.1016\/j.amjsurg.2012.07.048"},{"key":"4","doi-asserted-by":"publisher","unstructured":"[4] Y. Terada, H. Akabori, H. Ohta, Y. Nishina, and E. Mekata, \u201cEarly experience with a new integrated microwave surgical device, Acrosurg Revo\u00ae, for laparoscopic surgery: A case series of two patients,\u201d Int. J. Surg. Case Rep., vol.78, pp.375-377, Jan. 2021. DOI:10.1016\/j.ijscr.2020.12.063 10.1016\/j.ijscr.2020.12.063","DOI":"10.1016\/j.ijscr.2020.12.063"},{"key":"5","doi-asserted-by":"publisher","unstructured":"[5] M. Morimoto, H. Horie, K. Koinuma, K. Mori, Y. Kono, K. Oshiro, Y. Inoue, H. Maruyama, A.T. Lefor, and N. Sata, \u201cHow to evacuate surgical smoke while using laparoscopic coagulation shears,\u201d Adv. Laparoscopy, vol.1, no.1, pp.1-4, June 2017. DOI:10.36959\/367\/431 10.36959\/367\/431","DOI":"10.36959\/367\/431"},{"key":"6","doi-asserted-by":"publisher","unstructured":"[6] S.M. In, D.-Y. Park, I.K. Sohn, C.-H. Kim, H.L. Lim, S.-A. Hong, D.Y. Jung, S.-Y. Jeong, J.H. Han, and H.J. Kim, \u201cExperimental study of the potential hazards of surgical smoke from powered instruments,\u201d BJS, vol.102, no.12, pp.1581-1586, Nov. 2015. DOI:10.1002\/bjs.9910 10.1002\/bjs.9910","DOI":"10.1002\/bjs.9910"},{"key":"7","doi-asserted-by":"publisher","unstructured":"[7] M.J. Taravella, A. Weinberg, M. May and P. Stepp, \u201cLive virus survives excimer laser ablation,\u201d Ophthalmology, vol.106, no.8, pp.1498-1499, Aug. 1999. DOI:10.1016\/S0161-6420(99)90442-6 10.1016\/s0161-6420(99)90442-6","DOI":"10.1016\/S0161-6420(99)90442-6"},{"key":"8","doi-asserted-by":"publisher","unstructured":"[8] S.H. Choi, T.G. Kwon, S.K. Chung, and T.-H. Kim, \u201cSurgical smoke may be a biohazard to surgeons performing laparoscopic surgery,\u201d Surg. Endosc., vol.28, pp.2374-2380, Feb. 2014. DOI:10.1007\/s00464-014-3472-3 10.1007\/s00464-014-3472-3","DOI":"10.1007\/s00464-014-3472-3"},{"key":"9","doi-asserted-by":"publisher","unstructured":"[9] H. Huang, L. Zhang, M.A.J. Moser, W. Zhang, and B. Zhang, \u201cA review of antenna designs for percutaneous microwave ablation,\u201d Phys. Med., vol.84, pp.254-264, April 2021. DOI:10.1016\/j.ejmp.2021.03.010 10.1016\/j.ejmp.2021.03.010","DOI":"10.1016\/j.ejmp.2021.03.010"},{"key":"10","doi-asserted-by":"publisher","unstructured":"[10] W. Hurter, F. Reinbold, and W.J. Lorenz, \u201cA dipole antenna for interstitial microwave hyperthermia,\u201d IEEE Trans. Microw. Theory Tech., vol.39, no.6, pp.1048-1054, June 1991. DOI:10.1109\/22.81680 10.1109\/22.81680","DOI":"10.1109\/22.81680"},{"key":"11","doi-asserted-by":"publisher","unstructured":"[11] J. Chiang, L. Song, F. Abtin, and Y. Rahmat-Samii, \u201cEfficacy of lung-tuned monopole antenna for microwave ablation: Analytical solution and validation in a ventilator-controlled <i>ex vivo<\/i> porcine lung model,\u201d IEEE J. Electromagn. RF Microw. Med. Biol., vol.5, no.4, pp.295-304, Dec. 2021. DOI:10.1109\/jerm.2021.3066103 10.1109\/jerm.2021.3066103","DOI":"10.1109\/JERM.2021.3066103"},{"key":"12","doi-asserted-by":"crossref","unstructured":"[12] K. Saito and K. Ito, \u201cA study of the SAR distribution of a coaxial-slot antenna for interstitial microwave hyperthermia by the fdtd method,\u201d Electronics and Communications in Japan, vol.84, no.3, pp.48-55, Nov. 2000. 10.1002\/1520-6424(200103)84:3%3C48::AID-ECJA6%3E3.0.CO;2-S","DOI":"10.1002\/1520-6424(200103)84:3<48::AID-ECJA6>3.0.CO;2-S"},{"key":"13","doi-asserted-by":"publisher","unstructured":"[13] H. Fallahi and P. Prakash, \u201cAntenna designs for microwave tissue ablation,\u201d Crit. Rev. Biomed. Eng., vol.46, no.6, pp.495-521, 2018. DOI:10.1615\/CritRevBiomedEng.2018028554 10.1615\/CritRevBiomedEng.2018028554","DOI":"10.1615\/CritRevBiomedEng.2018028554"},{"key":"14","doi-asserted-by":"publisher","unstructured":"[14] D. Yang, J.M. Bertram, M.C. Converse, A.P. O\u2019Rourke, J.G. Webster, S.C. Hagness, J.A. Will, and D.M. Mahvi, \u201cA floating sleeve antenna yields localized hepatic microwave ablation,\u201d IEEE Trans. Biomed. Eng., vol.53, no.3, pp.533-537, March 2006. DOI:10.1109\/TBME.2005.869794 10.1109\/tbme.2005.869794","DOI":"10.1109\/TBME.2005.869794"},{"key":"15","doi-asserted-by":"publisher","unstructured":"[15] Z.A. Ibitoye, E.O. Nwoye, M.A. Aweda, A.A. Oremosu, C.C. Annunobi, and O.N. Akanmu, \u201cOptimization of dual slot antenna using floating metallic sleeve for microwave ablation,\u201d Med. Eng. Phys., vol.37, no.4, pp.384-391, April 2015. DOI:10.1016\/j.medengphy.2015.01.015 10.1016\/j.medengphy.2015.01.015","DOI":"10.1016\/j.medengphy.2015.01.015"},{"key":"16","unstructured":"[16] H. Acikgoz and R. Mittra, \u201cMicrowave coaxial antenna for cancer treatment: Reducing the backward heating using a double choke,\u201d ISAP, Hobart, IEEE Trans. Aerosp., Australia, April 2016."},{"key":"17","doi-asserted-by":"publisher","unstructured":"[17] T. Nishidate and K. Saito, \u201cStudy of sleeve inner diameter to suppress backward heating for microwave surgical energy device,\u201d IEICE ELEX, vol.21, no.2, pp.1-5, Jan. 2024. DOI:10.1587\/elex.20.20230462 10.1587\/elex.20.20230462","DOI":"10.1587\/elex.20.20230462"},{"key":"18","doi-asserted-by":"publisher","unstructured":"[18] M. Ahmed, C.L. Brace, F.T. Lee, Jr., and S.N. Goldberg, \u201cPrinciples of and Advances in percutaneous ablation,\u201d Radiology, vol.258, no.2, pp.351-369, Feb. 2011. DOI:10.1148\/radiol.10081634 10.1148\/radiol.10081634","DOI":"10.1148\/radiol.10081634"},{"key":"19","doi-asserted-by":"publisher","unstructured":"[19] G.C. van Rhoon, P.J.M. Rietveld, and J. van der Zee, \u201cA 433 MHz lucite cone waveguide applicator for superficial hyperthermia,\u201d Int. J. Hyperthermia, vol.14, no.1, pp.13-27, 1998. DOI:10.3109\/02656739809018211 10.3109\/02656739809018211","DOI":"10.3109\/02656739809018211"},{"key":"20","doi-asserted-by":"publisher","unstructured":"[20] T. Drizdal, M.M. Paulides, J. Vrba, and G.C. van Rhoon, \u201cWaveguide-based applicators for superficial hyperthermia treatment: is tuning really required?,\u201d J. Electromagn. Waves Appl., vol.27, no.6, pp.682-690, Jan. 2013. DOI:10.1080\/09205071.2013.762609 10.1080\/09205071.2013.762609","DOI":"10.1080\/09205071.2013.762609"},{"key":"21","doi-asserted-by":"publisher","unstructured":"[21] W.J.R. Hoefer and M.N. Burton, \u201cClosed-form expressions for the parameters of finned and ridged waveguides,\u201d IEEE T-MTT, vol.30, no.12, pp.2190-2194, Dec. 1982. DOI:10.1109\/TMTT.1982.1131406 10.1109\/tmtt.1982.1131406","DOI":"10.1109\/TMTT.1982.1131406"},{"key":"22","doi-asserted-by":"publisher","unstructured":"[22] S. Hopfer, \u201cThe design of ridged waveguides,\u201d IRE Trans. Microw. Theory Tech., vol.3, no.5, pp.20-29, Oct. 1955. DOI:10.1109\/TMTT.1955.1124972 10.1109\/tmtt.1955.1124972","DOI":"10.1109\/TMTT.1955.1124972"},{"key":"23","doi-asserted-by":"publisher","unstructured":"[23] T.N. Anderson, \u201cDouble-ring waveguide for commercial airlines weather rader installation,\u201d IRE Trans. Microw. Theory Tech., vol.3, no.4, pp.2-9, July 1955. DOI:10.1109\/TMTT.1955.1124951 10.1109\/tmtt.1955.1124951","DOI":"10.1109\/TMTT.1955.1124951"},{"key":"24","doi-asserted-by":"publisher","unstructured":"[24] J.-Y. Deng, R. Cao, D. Sun, Y. Zhang, L.-X. Guo, \u201cBandwidth enhancement of an antipodal vivaldi antenna facilitated by double-ridged substrate-integrated waveguide,\u201d IEEE Trans. Antennas Propag., vol.68, no.12, pp.8192-8196, Dec. 2020. DOI:10.1109\/TAP.2020.2997474 10.1109\/tap.2020.2997474","DOI":"10.1109\/TAP.2020.2997474"},{"key":"25","doi-asserted-by":"publisher","unstructured":"[25] J. Song, X. Sun, Y. Du, Q. Wu, M. Niu, C. Fu, L. Tan, X. Ren, L. Chen, and X. Meng, \u201cMicro-opening ridged waveguide tumor hyperthermia antenna combined with microwave-sensitive MOF material for tumor microwave hyperthermia therapy,\u201d ACS Appl. Bio Mater., vol.5, no.9, pp.4154-4164, Aug. 2022. DOI:10.1021\/acsabm.2c00234 10.1021\/acsabm.2c00234","DOI":"10.1021\/acsabm.2c00234"},{"key":"26","doi-asserted-by":"crossref","unstructured":"[26] K.S. Yee, \u201cNumerical solution of initial boundary value problems involving Maxwell\u2019s equations in Isotropic media,\u201d IEEE Trans. Antennas Propag., vol.14, no.3, pp.302-307, May 1966. DOI:10.1109\/TAP.1966.1138693","DOI":"10.1109\/TAP.1966.1138693"},{"key":"27","doi-asserted-by":"publisher","unstructured":"[27] K. Saito, Y. Hayashi, H. Yoshimura, and K. Ito, \u201cHeating characteristics of array applicator composed of two coaxial-slot antennas for microwave coagulation therapy,\u201d IEEE Trans. Microw. Theory Tech., vol.48, no.11, pp.1800-1806, Nov. 2000. DOI:10.1109\/22.883857 10.1109\/22.883857","DOI":"10.1109\/22.883857"},{"key":"28","doi-asserted-by":"crossref","unstructured":"[28] H.H. Pennes, \u201cAnalysis of tissue and arterial blood temperatures in the resting human forearm,\u201d J. Appl. Physiol., vol.1, no.2, pp.93-122, Aug. 1948. DOI:10.1152\/jappl.1948.1.2.93 10.1152\/jappl.1948.1.2.93","DOI":"10.1152\/jappl.1948.1.2.93"},{"key":"29","unstructured":"[29] \u201cIT\u2019IS Foundation Homepage,\u201d [Online]. Available: https:\/\/itis.swiss\/virtual-population\/tissue-properties\/database\/dielectric-properties\/."},{"key":"30","unstructured":"[30] \u201cRISHO KOGYO CO., LTD. Homepage,\u201d [Online]. Available: https:\/\/www.risho.co.jp\/product\/products1\/cs\/3396.htm."},{"key":"31","doi-asserted-by":"crossref","unstructured":"[31] Y. Okano, K. Ito, I. Ida, and M. Takahashi, \u201cThe SAR evaluation method by a combination of thermographic experiments and biological tissue-equivalent phantoms,\u201d IEEE Trans. Microw. Theory Tech., vol.48, no.11, pp.2094-2103, Nov. 2000. 10.1109\/22.884200","DOI":"10.1109\/22.884200"}],"container-title":["IEICE Transactions on Electronics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/transele\/E109.C\/4\/E109.C_2025ECP5050\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,4]],"date-time":"2026-04-04T03:46:40Z","timestamp":1775274400000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/transele\/E109.C\/4\/E109.C_2025ECP5050\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,1]]},"references-count":31,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1587\/transele.2025ecp5050","relation":{},"ISSN":["0916-8524","1745-1353"],"issn-type":[{"value":"0916-8524","type":"print"},{"value":"1745-1353","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,1]]},"article-number":"2025ECP5050"}}