{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,8,4]],"date-time":"2024-08-04T00:15:26Z","timestamp":1722730526596},"reference-count":18,"publisher":"Institute of Electronics, Information and Communications Engineers (IEICE)","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEICE Trans. Fundamentals"],"published-print":{"date-parts":[[2024,8,1]]},"DOI":"10.1587\/transfun.2023eap1051","type":"journal-article","created":{"date-parts":[[2023,12,27]],"date-time":"2023-12-27T22:13:11Z","timestamp":1703715191000},"page":"1338-1344","source":"Crossref","is-referenced-by-count":0,"title":["Optimization of Multi-Component Olfactory Display Using Inkjet Devices"],"prefix":"10.1587","volume":"E107.A","author":[{"given":"Hiroya","family":"HACHIYAMA","sequence":"first","affiliation":[{"name":"Tokyo Institute of Technology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takamichi","family":"NAKAMOTO","sequence":"additional","affiliation":[{"name":"Tokyo Institute of Technology"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"532","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"[1] Y. Yanagida, \u201cA survey of olfactory displays: Making and delivering scents,\u201d SENSORS, 2012 IEEE, pp.1-4, 2012. doi: 10.1109\/ICSENS.2012.6411380 10.1109\/icsens.2012.6411380","DOI":"10.1109\/ICSENS.2012.6411380"},{"key":"2","doi-asserted-by":"crossref","unstructured":"[2] F. Nakaizumi, H. Noma, K. Hosaka, and Y. Yanagida, \u201cSpotScents: A novel method of natural scent delivery using multiple scent projectors,\u201d IEEE Virtual Reality Conference (VR 2006), pp.207-214, 2006. doi: 10.1109\/VR.2006.122 10.1109\/vr.2006.122","DOI":"10.1109\/VR.2006.122"},{"key":"3","doi-asserted-by":"crossref","unstructured":"[3] D.W. Kim, Y.H. Cho, K. Nishimoto, Y. Kawakami, S. Kunifuji, and H. Ando, \u201cDevelopment of aroma-card based soundless olfactory display,\u201d 2009 16th IEEE International Conference on Electronics, Circuits and System-(ICECS 2009), pp.703-706, 2009. doi: 10.1109\/ICECS.2009.5410784 10.1109\/icecs.2009.5410784","DOI":"10.1109\/ICECS.2009.5410784"},{"key":"4","doi-asserted-by":"publisher","unstructured":"[4] H. Kim, J. Park, K. Noh, C.J. Gardner, S.D. Kong, J. Kim, and S. Jin, \u201cAn <i>X<\/i>-<i>Y<\/i> addressable matrix odor-releasing system using an onff switchable device,\u201d Angewandte Chemie International Edition, vol.50, no.30, pp.6771-6775, 2011. 10.1002\/anie.201102759","DOI":"10.1002\/anie.201102759"},{"key":"5","doi-asserted-by":"crossref","unstructured":"[5] J. Amores and P. Maes, \u201cOlfactory interfaces for unconscious influence of mood and cognitive performance,\u201d Proc. 2017 CHI Conference on Human Factors in Computing Systems, pp.28-34, 2017. doi: 10.1145\/3025453.3026004 10.1145\/3025453.3026004","DOI":"10.1145\/3025453.3026004"},{"key":"6","doi-asserted-by":"publisher","unstructured":"[6] H. Matsukura, T. Yoneda, and H. Ishida, \u201cSmelling screen: Development and evaluation of an olfactory display system for presenting a virtual odor source,\u201d IEEE Trans. Vis. Comput. Graphics, vol.19, no.4, pp.606-615, 2013. doi: 10.1109\/TVCG.2013.40 10.1109\/tvcg.2013.40","DOI":"10.1109\/TVCG.2013.40"},{"key":"7","doi-asserted-by":"publisher","unstructured":"[7] T. Nakamoto and K. Yoshikawa, \u201cMovie with scents generated by olfactory display using solenoid valves,\u201d IEICE Trans. Fundamentals, vol.E89-A, no.11, pp.3327-3332, Nov. 2006. 10.1093\/ietfec\/e89-a.11.3327","DOI":"10.1093\/ietfec\/e89-a.11.3327"},{"key":"8","doi-asserted-by":"crossref","unstructured":"[8] A. Mochizuki, T. Amada, S. Sawa, T. Takeda, S. Motoyashiki, K. Kohyama, M. Imura, and K. Chihara, \u201cFragra: A visual-olfactory VR game,\u201d ACM SIGGRAPH 2004 Sketches, p.123, 2004. doi: 10.1145\/1186223.1186377 10.1145\/1186223.1186377","DOI":"10.1145\/1186223.1186377"},{"key":"9","doi-asserted-by":"publisher","unstructured":"[9] N. Ranasinghe, K.C.R. Koh, N.T.N. Tram, Y. Liangkun, K. Shamaiah, S.G. Choo, D. Tolley, S. Karwita, B. Chew, D. Chua, and E.Y.-L. Do, \u201cTainted: An olfaction-enhanced game narrative for smelling virtual ghosts,\u201d International Journal of Human-Computer Studies, vol.125, pp.p7-18, 2019. 10.1016\/j.ijhcs.2018.11.011","DOI":"10.1016\/j.ijhcs.2018.11.011"},{"key":"10","doi-asserted-by":"publisher","unstructured":"[10] T. Nakamoto, S. Otaguro, M. Kinoshita, M. Nagahama, K. Ohinishi, and T. Ishida, \u201cCooking up an interactive olfactory game display,\u201d IEEE Comput. Graph. Appl., vol.28, no.1, pp.75-78, 2008. 10.1109\/mcg.2008.3","DOI":"10.1109\/MCG.2008.3"},{"key":"11","doi-asserted-by":"crossref","unstructured":"[11] T. Nakamoto, T. Hirasawa, and Y. Hanyu, \u201cVirtual environment with smell using wearable olfactory display and computational fluid dynamics simulation,\u201d 2020 IEEE Conference on Virtual Reality and 3D User Interfaces, pp.713-720, 2020. doi: 10.1109\/VR46266.2020.00094 10.1109\/vr46266.2020.1581303036097","DOI":"10.1109\/VR46266.2020.00094"},{"key":"12","doi-asserted-by":"publisher","unstructured":"[12] T. Nakamoto, M. Ohno, and Y. Nihei, \u201cOdor approximation using mass spectrometry,\u201d IEEE Sensors J., vol.12, no.11, pp.3225-3231, 2012. 10.1109\/jsen.2012.2190506","DOI":"10.1109\/JSEN.2012.2190506"},{"key":"13","doi-asserted-by":"publisher","unstructured":"[13] M. Iseki, D. Prasetyawan, Y. Yokoshiki, and T. Nakamoto, \u201cA study of odor reproduction using multi-component olfactory display,\u201d Electrical Engineering in Japan, vol.215, no.3, e23392, 2022. 10.1002\/eej.23392","DOI":"10.1002\/eej.23392"},{"key":"14","doi-asserted-by":"publisher","unstructured":"[14] Y. Ariyakul and T. Nakamoto, \u201cFundamental study of olfactory display using extremely small liquid pump and SAW atomizer,\u201d The Virtual Reality Society of Japan, vol.15, no.4, pp.589-594, 2010. 10.18974\/tvrsj.15.4_589","DOI":"10.18974\/tvrsj.15.4_589"},{"key":"15","doi-asserted-by":"publisher","unstructured":"[15] T. Nakamoto, S. Ito, S. Kato, and G.P. Qi, \u201cMulticomponent olfactory display using solenoid valves and SAW atomizer and its blending-capability evaluation,\u201d IEEE Sensors J., vol.18, no.13, pp.5213-5219, 2018. 10.1109\/jsen.2018.2834953","DOI":"10.1109\/JSEN.2018.2834953"},{"key":"16","unstructured":"[16] T. Nakamoto, H. Takigawa, and T. Yamanaka, \u201cFundamental study of odor recorder using inkjet devices for low-volatile scents,\u201d IEICE Trans. Electronics, vol.E87-C, no.12, pp.2081-2086, 2004."},{"key":"17","doi-asserted-by":"crossref","unstructured":"[17] S. Sugimoto, D. Noguchi, Y. Bannnai, and K. Okada, \u201cInk jet olfactory display enabling instantaneous switches of scents,\u201d Proc. 18th ACM International Conference on Multimedia, pp.301-310, 2010. doi: 10.1145\/1873951.1873994 10.1145\/1873951.1873994","DOI":"10.1145\/1873951.1873994"},{"key":"18","unstructured":"[18] Data sheet of ppbRAE 3000+, Honeywell, 2018."}],"container-title":["IEICE Transactions on Fundamentals of Electronics, Communications and Computer Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/transfun\/E107.A\/8\/E107.A_2023EAP1051\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,3]],"date-time":"2024-08-03T03:26:04Z","timestamp":1722655564000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/transfun\/E107.A\/8\/E107.A_2023EAP1051\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,1]]},"references-count":18,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1587\/transfun.2023eap1051","relation":{},"ISSN":["0916-8508","1745-1337"],"issn-type":[{"type":"print","value":"0916-8508"},{"type":"electronic","value":"1745-1337"}],"subject":[],"published":{"date-parts":[[2024,8,1]]},"article-number":"2023EAP1051"}}