{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,8,4]],"date-time":"2024-08-04T00:15:48Z","timestamp":1722730548810},"reference-count":34,"publisher":"Institute of Electronics, Information and Communications Engineers (IEICE)","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEICE Trans. Fundamentals"],"published-print":{"date-parts":[[2024,8,1]]},"DOI":"10.1587\/transfun.2023eap1093","type":"journal-article","created":{"date-parts":[[2024,2,8]],"date-time":"2024-02-08T22:12:31Z","timestamp":1707430351000},"page":"1127-1138","source":"Crossref","is-referenced-by-count":0,"title":["A Multi-Channel Biomedical Sensor System with System-Level Chopping and Stochastic A\/D Conversion"],"prefix":"10.1587","volume":"E107.A","author":[{"given":"Yusaku","family":"HIRAI","sequence":"first","affiliation":[{"name":"Graduate School of Information Science and Technology, Osaka University"},{"name":"SPChange, LLC."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshimasa","family":"MATSUOKA","sequence":"additional","affiliation":[{"name":"Graduate School of Engineering, Osaka University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takatsugu","family":"KAMATA","sequence":"additional","affiliation":[{"name":"SPChange, LLC."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sadahiro","family":"TANI","sequence":"additional","affiliation":[{"name":"SPChange, LLC."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takao","family":"ONOYE","sequence":"additional","affiliation":[{"name":"Graduate School of Information Science and Technology, Osaka University"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"532","reference":[{"key":"1","doi-asserted-by":"publisher","unstructured":"[1] A. Matsuzawa, \u201cDigital-centric RF CMOS technologies,\u201d IEICE Trans. Electron., vol.E91-C, no.11, pp.1720-1725, Nov. 2008. 10.1093\/ietele\/e91-c.11.1720","DOI":"10.1093\/ietele\/e91-c.11.1720"},{"key":"2","doi-asserted-by":"publisher","unstructured":"[2] K. Uyttenhove and M.S. Steyaert, \u201cSpeed-power-accuracy tradeoff in high-speed CMOS ADCs,\u201d IEEE Trans. Circuits Syst. II, Analog Digit. Signal Process., vol.49, no.4, pp.280-287, April 2002. 10.1109\/tcsii.2002.801191","DOI":"10.1109\/TCSII.2002.801191"},{"key":"3","doi-asserted-by":"crossref","unstructured":"[3] T. Denison, K. Consoer, A. Kelly, A. Hachenburg, and W. Santa, \u201cA 2.2\u00b5W 94nV\/$\\sqrt{\\rm{Hz}}$, chopper-stabilized instrumentation amplifier for EEG detection in chronic implants,\u201d IEEE Int. Solid-State Circuits Conf., pp.162-594, Feb. 2007. 10.1109\/isscc.2007.373638","DOI":"10.1109\/ISSCC.2007.373638"},{"key":"4","doi-asserted-by":"crossref","unstructured":"[4] X. Yang, Y. Zhang, W.w. Huang, and C.d. Ling, \u201cLow power chopper amplifier without LPF,\u201d IEEE Asia Pacific Conf. Circuits Syst., pp.17-19, Dec. 2010. 10.1109\/apccas.2010.5774901","DOI":"10.1109\/APCCAS.2010.5774901"},{"key":"5","doi-asserted-by":"publisher","unstructured":"[5] M. Khayatzadeh, X. Zhang, J. Tan, W.-S. Liew, and Y. Lian, \u201cA 0.7-V 17.4-\u00b5W 3-Lead Wireless ECG SoC,\u201d IEEE Trans. Biomed. Circuits Syst., vol.7, no.5, pp.583-592, Oct. 2013. 10.1109\/TBCAS.2013.2279398","DOI":"10.1109\/TBCAS.2013.2279398"},{"key":"6","doi-asserted-by":"crossref","unstructured":"[6] S.Y. Lee, C.J. Cheng, C.P. Wang, and S.C. Lee, \u201cA 1-V 8-bit 0.95mW successive approximation ADC for biosignal acquisition systems,\u201d IEEE Int. Symp. Circuits Syst., pp.649-652, May 2009. 10.1109\/iscas.2009.5117832","DOI":"10.1109\/ISCAS.2009.5117832"},{"key":"7","doi-asserted-by":"publisher","unstructured":"[7] L. Chen, X. Tang, A. Sanyal, Y. Yoon, J. Cong, and N. Sun, \u201cA 0.7-V 0.6-\u00b5W 100-kS\/s low-power SAR ADC with statistical estimation-based noise reduction,\u201d IEEE J. Solid-State Circuits, vol.52, no.5, pp.1388-1398, May 2017. 10.1109\/JSSC.2017.2656138","DOI":"10.1109\/JSSC.2017.2656138"},{"key":"8","doi-asserted-by":"publisher","unstructured":"[8] M. Bagheri, F. Schembari, N. Pourmousavian, H. Zare-Hoseini, D. Hasko, and R.B. Staszewski, \u201cA mismatch calibration technique for SAR ADCs based on deterministic self-calibration and stochastic quantization,\u201d IEEE Trans. Circuits Syst. I. Reg. Papers, vol.67, no.9, pp.2883-2896, Sept. 2020. 10.1109\/tcsi.2020.2985816","DOI":"10.1109\/TCSI.2020.2985816"},{"key":"9","doi-asserted-by":"publisher","unstructured":"[9] H.S. Lee, D. Hodges, and P. Gray, \u201cA self-calibrating 15 bit CMOS A\/D converter,\u201d IEEE J. Solid-State Circuits, vol.19, no.6, pp.813-819, Dec. 1984. 10.1109\/jssc.1984.1052231","DOI":"10.1109\/JSSC.1984.1052231"},{"key":"10","doi-asserted-by":"publisher","unstructured":"[10] D. McCartney, A. Sherry, J. O&apos;Dowd, and P. Hickey, \u201cA low-noise low-drift transducer ADC,\u201d IEEE J. Solid-State Circuits, vol.32, no.7, pp.959-967, July 1997. 10.1109\/4.597286","DOI":"10.1109\/4.597286"},{"key":"11","doi-asserted-by":"crossref","unstructured":"[11] J.L. Ceballos and C. Reindl, \u201cA low-power, ultra low-offset, 16.5-bit, \u03a3\u0394ADC for coulomb counting and fuel gauge applications,\u201d IEEE Int. Symp. Circuits Syst., pp.817-820, May 2013. 10.1109\/iscas.2013.6571972","DOI":"10.1109\/ISCAS.2013.6571972"},{"key":"12","doi-asserted-by":"crossref","unstructured":"[12] R. Wu, J.H. Huijsing, and K.A.A. Makinwa, \u201cA 21-bit read-out IC employing dynamic element matching with 0.037% gain error,\u201d IEEE Asian Solid-State Circuits Conf., pp.241-244, Nov. 2011. 10.1109\/asscc.2011.6123647","DOI":"10.1109\/ASSCC.2011.6123647"},{"key":"13","doi-asserted-by":"crossref","unstructured":"[13] L. Xu, B. G\u00f6nen, Q. Fan, J.H. Huijsing, and K.A.A. Makinwa, \u201cA 110dB SNR ADC with \u00b130V input common-mode range and 8\u00b5V offset for current sensing applications,\u201d IEEE Int. Solid-State Circuits Conf., pp.90-92, Feb. 2015. 10.1109\/isscc.2015.7062940","DOI":"10.1109\/ISSCC.2015.7062940"},{"key":"14","doi-asserted-by":"crossref","unstructured":"[14] M. Mikawa, S. Kawazoe, R. Fukuoka, and N. Nakano, \u201cA delta-sigma modulator with frequency division multiplexing for multi-channel EEG acquisition front-end,\u201d IEEE Int. Conf. Electron. Circuits Syst., pp.97-100, Nov. 2019. 10.1109\/icecs46596.2019.8965052","DOI":"10.1109\/ICECS46596.2019.8965052"},{"key":"15","doi-asserted-by":"publisher","unstructured":"[15] C. Enz and G. Temes, \u201cCircuit techniques for reducing the effects of op-amp imperfections: Autozeroing, correlated double sampling, and chopper stabilization,\u201d Proc. IEEE, vol.84, no.11, pp.1584-1614, Nov. 1996. 10.1109\/5.542410","DOI":"10.1109\/5.542410"},{"key":"16","unstructured":"[16] D. Cottier, \u201cMethods for mitigating ADC memory cross-talk,\u201d Texas Instruments Application Note, no.SPRACW9A, 2021."},{"key":"17","doi-asserted-by":"publisher","unstructured":"[17] M. Zhang and X. Fan, \u201cAn energy-efficient SAR ADC using a single-phase clocked dynamic comparator with energy and speed enhanced technique,\u201d IEICE Electron. Express, vol.14, no.8, pp.1-9, April 2017. 10.1587\/elex.14.20170219","DOI":"10.1587\/elex.14.20170219"},{"key":"18","doi-asserted-by":"publisher","unstructured":"[18] Y. Guo, Y. Wu, D. Guo, X. Cheng, Z. Yu, and X. Zeng, \u201cNon-binary digital calibration for split-capacitor DAC in SAR ADC,\u201d IEICE Electron. Express, vol.12, no.4, pp.1-8, Feb. 2015. 10.1587\/elex.12.20150001","DOI":"10.1587\/elex.12.20150001"},{"key":"19","doi-asserted-by":"publisher","unstructured":"[19] J.Y. Um, Y.J. Kim, E.W. Song, J.Y. Sim, and H.J. Park, \u201cA digital-domain calibration of split-capacitor DAC for a differential SAR ADC without additional analog circuits,\u201d IEEE Trans. Circuits Syst. I, Reg. Papers, vol.60, no.11, pp.2845-2856, Nov. 2013. 10.1109\/tcsi.2013.2252475","DOI":"10.1109\/TCSI.2013.2252475"},{"key":"20","doi-asserted-by":"publisher","unstructured":"[20] S. Weaver, B. Hershberg, and U.K. Moon, \u201cDigitally synthesized stochastic flash ADC using only standard digital cells,\u201d IEEE Trans. Circuits Syst. I, Reg. Papers, vol.61, no.1, pp.84-91, Jan. 2014. 10.1109\/tcsi.2013.2268571","DOI":"10.1109\/TCSI.2013.2268571"},{"key":"21","doi-asserted-by":"crossref","unstructured":"[21] H. Ham, T. Matsuoka, and K. Taniguchi, \u201cApplication of noise-enhanced detection of subthreshold signals for communication systems,\u201d IEICE Trans. Fundamentals, vol.E92-A, no.4, pp.1012-1018, April 2009. 10.1587\/transfun.e92.a.1012","DOI":"10.1587\/transfun.E92.A.1012"},{"key":"22","doi-asserted-by":"publisher","unstructured":"[22] S. Tani, T. Matsuoka, Y. Hirai, T. Kurata, K. Tatsumi, T. Asano, M. Ueda, and T. Kamata, \u201cBehavior-level analysis of a successive stochastic approximation analog-to-digital conversion system for multi-channel biomedical data acquisition,\u201d IEICE Trans. Fundamentals, vol.E100-A, no.10, pp.2073-2085, Oct. 2017. 10.1587\/transfun.e100.a.2073","DOI":"10.1587\/transfun.E100.A.2073"},{"key":"23","doi-asserted-by":"publisher","unstructured":"[23] Y. Hirai, T. Matsuoka, S. Tani, S. Isami, K. Tatsumi, M. Ueda, and T. Kamata, \u201cA biomedical sensor system with stochastic A\/D conversion and error correction by machine learning,\u201d IEEE Access, vol.7, pp.21990-22001, Feb. 2019. 10.1109\/access.2019.2898154","DOI":"10.1109\/ACCESS.2019.2898154"},{"key":"24","doi-asserted-by":"publisher","unstructured":"[24] B. Verbruggen, J. Tsouhlarakis, T. Yamamoto, M. Iriguchi, E. Martens, and J. Craninckx, \u201cA 60dB SNDR 35MS\/s SAR ADC with comparator-noise-based stochastic residue estimation,\u201d IEEE J. Solid-State Circuits, vol.50, no.9, pp.2002-2011, Sept. 2015. 10.1109\/jssc.2015.2422781","DOI":"10.1109\/JSSC.2015.2422781"},{"key":"25","doi-asserted-by":"publisher","unstructured":"[25] T. Miki, T. Morie, K. Matsukawa, Y. Bando, T. Okumoto, K. Obata, S. Sakiyama, and S. Dosho, \u201cA 4.2mW 50MS\/s 13bit CMOS SAR ADC With SNR and SFDR enhancement techniques,\u201d IEEE J. Solid-State Circuits, vol.50, no.6, pp.1372-1381, June 2015. 10.1109\/jssc.2015.2417803","DOI":"10.1109\/JSSC.2015.2417803"},{"key":"26","doi-asserted-by":"crossref","unstructured":"[26] J.J. Collins, C.C. Chow, and T.T. Imhoff, \u201cStochastic resonance without tuning,\u201d Nature, vol.376, no.6537, pp.236-238, July 1995. 10.1038\/376236a0","DOI":"10.1038\/376236a0"},{"key":"27","doi-asserted-by":"crossref","unstructured":"[27] T. Yoshida, Y. Masui, R. Eki, A. Iwata, M. Yoshida, and K. Uematsu, \u201cA neural recording amplifier with low-frequency noise suppression,\u201d IEICE Trans. Electron., vol.E93-C, no.6, pp.849-854, June 2010. 10.1587\/transele.e93.c.849","DOI":"10.1587\/transele.E93.C.849"},{"key":"28","doi-asserted-by":"publisher","unstructured":"[28] M.A. Bin Altaf, C. Zhang, and J. Yoo, \u201cA 16-channel patient-specific seizure onset and termination detection SoC with impedance-adaptive transcranial electrical stimulator,\u201d IEEE J. Solid-State Circuits, vol.50, no.11, pp.2728-2740, Nov. 2015. 10.1109\/jssc.2015.2482498","DOI":"10.1109\/JSSC.2015.2482498"},{"key":"29","doi-asserted-by":"publisher","unstructured":"[29] T. Tang, W.L. Goh, L. Yao, and Y. Gao, \u201cA TDM-based 16-channel AFE ASIC with enhanced system-level CMRR for wearable EEG recording with dry electrodes,\u201d IEEE Trans. Biomed. Circuits Syst., vol.14, no.3, pp.516-524, June 2020. 10.1109\/tbcas.2020.2979931","DOI":"10.1109\/TBCAS.2020.2979931"},{"key":"30","doi-asserted-by":"publisher","unstructured":"[30] J.H. Park, T. Tang, L. Zhang, K.A. Ng, G.G.L. Gammad, S.C. Yen, and J. Yoo, \u201cA 15-channel orthogonal code chopping instrumentation amplifier for area-efficient, low-mismatch bio-signal acquisition,\u201d IEEE J. Solid-State Circuits, vol.55, no.10, pp.2771-2780, Oct. 2020. 10.1109\/jssc.2020.2991542","DOI":"10.1109\/JSSC.2020.2991542"},{"key":"31","doi-asserted-by":"publisher","unstructured":"[31] Y. Tian, Z. Qin, Y. Yu, D. Gao, X. Liao, and L. Liu, \u201cA low-noise and low-power multi-channel ECG AFE based on orthogonal current-reuse amplifier,\u201d IEEE Trans. Circuits Syst. I, Reg. Papers, vol.70, no.8, pp.3167-3177, Aug. 2023. 10.1109\/tcsi.2023.3277012","DOI":"10.1109\/TCSI.2023.3277012"},{"key":"32","unstructured":"[32] ADI, \u201cLow power, five electrode electrocardiogram (ECG) analog front end,\u201d ADAS1000 data sheet, 2012."},{"key":"33","doi-asserted-by":"publisher","unstructured":"[33] A. Jayaraj, S. Tannirkulam Chandrasekaran, A. Ganesh, I. Banerjee, and A. Sanyal, \u201cMaximum likelihood estimation-based SAR ADC,\u201d IEEE Trans. Circuits Syst. II, Exp. Briefs, vol.66, no.8, pp.1311-1315, Aug. 2019. 10.1109\/tcsii.2018.2886260","DOI":"10.1109\/TCSII.2018.2886260"},{"key":"34","doi-asserted-by":"publisher","unstructured":"[34] Z. Lei and Z. Xiaolin, \u201cMismatch suppression and noise reduction for SAR-ADC with Bayes estimation method,\u201d Analog Integr. Circuits Signal Process., vol.102, no.2, pp.379-388, Feb. 2020. 10.1007\/s10470-019-01573-0","DOI":"10.1007\/s10470-019-01573-0"}],"container-title":["IEICE Transactions on Fundamentals of Electronics, Communications and Computer Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/transfun\/E107.A\/8\/E107.A_2023EAP1093\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,3]],"date-time":"2024-08-03T03:26:44Z","timestamp":1722655604000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/transfun\/E107.A\/8\/E107.A_2023EAP1093\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,1]]},"references-count":34,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1587\/transfun.2023eap1093","relation":{},"ISSN":["0916-8508","1745-1337"],"issn-type":[{"type":"print","value":"0916-8508"},{"type":"electronic","value":"1745-1337"}],"subject":[],"published":{"date-parts":[[2024,8,1]]},"article-number":"2023EAP1093"}}