{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,3]],"date-time":"2025-08-03T01:11:52Z","timestamp":1754183512184,"version":"3.41.2"},"reference-count":34,"publisher":"Institute of Electronics, Information and Communications Engineers (IEICE)","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEICE Trans. Fundamentals"],"published-print":{"date-parts":[[2025,8,1]]},"DOI":"10.1587\/transfun.2024eap1066","type":"journal-article","created":{"date-parts":[[2025,1,29]],"date-time":"2025-01-29T17:12:17Z","timestamp":1738170737000},"page":"1066-1077","source":"Crossref","is-referenced-by-count":0,"title":["Principle Analysis for the Possibility of Scattered X-Ray to Improve Computed Tomography Reconstruction"],"prefix":"10.1587","volume":"E108.A","author":[{"given":"Naohiro","family":"TODA","sequence":"first","affiliation":[{"name":"School of Information Science and Technology, Aichi Prefectural University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tetsuya","family":"NAKAGAMI","sequence":"additional","affiliation":[{"name":"Technical Resources Department, DENSO CREATE INC."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"532","reference":[{"key":"1","unstructured":"[1] J. Hsieh, Computed Tomography: Principles, Design, Artifacts and Recent Developements, 4th ed., SPIE Press, Bellingham, Washington, USA, 2022. 10.1117\/3.2605933"},{"key":"2","doi-asserted-by":"publisher","unstructured":"[2] J. Poto\u010dnik, S. Foley, and E. Thomas, \u201cCurrent and potential applications of artificial intelligence in medical imaging practice: A narrative review,\u201d Journal of Medical Imaging and Radiation Sciences, vol.54, pp.376-385, April 14, 2023. DOI:10.1016\/j.jmir.2023.03.033 10.1016\/j.jmir.2023.03.033","DOI":"10.1016\/j.jmir.2023.03.033"},{"key":"3","doi-asserted-by":"publisher","unstructured":"[3] R. Booij, R.P.J. Budde, M.L. Dijkshoorn, and M. van Straten, \u201cTechnological developments of X-ray computed tomography over half a century: User\u2019s influence on protocol optimization,\u201d Eur. J. Radiol., vol.131, 109261, Aug. 2020. DOI:10.1016\/j.ejrad.2020.109261 10.1016\/j.ejrad.2020.109261","DOI":"10.1016\/j.ejrad.2020.109261"},{"key":"4","doi-asserted-by":"publisher","unstructured":"[4] H. Kanamori, N. Nakamori, K. Inoue, and E. Takenaka, \u201cEffects of scattered X-rays on CT images,\u201d Phys. Med. Biol., vol.30, no.3, pp.239-249, March 1985. DOI:10.1088\/0031-9155\/30\/3\/004 10.1088\/0031-9155\/30\/3\/004","DOI":"10.1088\/0031-9155\/30\/3\/004"},{"key":"5","unstructured":"[5] K. Tokumoto, Y. Yamazaki, N. Toda, and S. Koyama, \u201cEvaluation of scattered radiation in cone-beam dual-energy X-ray CT with Monte Carlo simulation,\u201d The Radiological Society of North America (RSNA) 98th Scientific Assembly and Annual Meeting, SSG16-02, Nov. 2013."},{"key":"6","doi-asserted-by":"publisher","unstructured":"[6] K. Yiannis and K. Willi, \u201cEfficiency of antiscatter grids for flat-detector CT,\u201d Phys. Med. Biol., vol.52, no.20, pp.6275-6293, Oct. 2007. DOI:10.1088\/0031-9155\/52\/20\/013 10.1088\/0031-9155\/52\/20\/013","DOI":"10.1088\/0031-9155\/52\/20\/013"},{"key":"7","doi-asserted-by":"publisher","unstructured":"[7] L. Zhu, Y. Xie, J. Wang, and L. Xing, \u201cScatter correction for cone-beam CT in radiation therapy,\u201d Med. Phys., vol.36, no.6, pp.2258-2268, May 2009. DOI:10.1118\/1.3130047 10.1118\/1.3130047","DOI":"10.1118\/1.3130047"},{"key":"8","doi-asserted-by":"publisher","unstructured":"[8] A. Akbarzadeh, M.R. Ay, H. Sarkar, and H. Zaidi, \u201cMeasurement of scattered radiation in a volumetric 64-slice CT scanner using three experimental techniques,\u201d Phys. Med. Biol., vol.55, no.8, pp.2269-2280, March 2010. DOI:10.1088\/0031-9155\/55\/8\/010 10.1088\/0031-9155\/55\/8\/010","DOI":"10.1088\/0031-9155\/55\/8\/010"},{"key":"9","doi-asserted-by":"publisher","unstructured":"[9] H. Yan, X. Mou, S. Tang, Q. Xu, and M. Zankl, \u201cProjection correlation based view interpolation for cone beam CT: Primary fluence restoration in scatter measurement with a moving beam stop array,\u201d Phys. Med. Biol., vol.55, no.21,pp.6353-6375, Oct. 2010. DOI:10.1088\/0031-9155\/55\/21\/002 10.1088\/0031-9155\/55\/21\/002","DOI":"10.1088\/0031-9155\/55\/21\/002"},{"key":"10","doi-asserted-by":"publisher","unstructured":"[10] W. Zhao, S. Brunner, K. Niu, S. Schafer, K. Royalty, and G.H. Chen, \u201cPatient-specific scatter correction for flat-panel detector-based cone-beam CT imaging,\u201d Phys. Med. Biol., vol.60, no.3, pp.1339-1365, Jan. 2015. DOI:10.1088\/0031-9155\/60\/3\/1339 10.1088\/0031-9155\/60\/3\/1339","DOI":"10.1088\/0031-9155\/60\/3\/1339"},{"key":"11","doi-asserted-by":"publisher","unstructured":"[11] M. Baer and M. Kachelrie\u00df, \u201cHybrid scatter correction for CT imaging,\u201d Phys. Med. Biol., vol.57, no.21, pp.6849-6867, Oct. 2012. DOI:10.1088\/0031-9155\/57\/21\/6849 10.1088\/0031-9155\/57\/21\/6849","DOI":"10.1088\/0031-9155\/57\/21\/6849"},{"key":"12","doi-asserted-by":"publisher","unstructured":"[12] G. Jarry, S.A. Graham, D.J. Moseley, D.J. Jaffray, J.H. Siewerdsen, and F. Verhaegen, \u201cCharacterization of scattered radiation in kV CBCT images using Monte Carlo simulations,\u201d Med. Phys., vol.33, no.11, pp.4320-4329, Oct. 2006. DOI:10.1118\/1.2358324 10.1118\/1.2358324","DOI":"10.1118\/1.2358324"},{"key":"13","doi-asserted-by":"publisher","unstructured":"[13] Y. Xu, T. Bai, H. Yan, L. Ouyang, A. Pompos, J. Wang, L. Zhou, S.B. Jiang, and X. Jia, \u201cA practical cone-beam CT scatter correction method with optimized Monte Carlo simulations for image-guided radiation therapy,\u201d Phys. Med. Biol., vol.60, no.9, pp.3567-3587, April 2015. DOI:10.1088\/0031-9155\/60\/9\/3567 10.1088\/0031-9155\/60\/9\/3567","DOI":"10.1088\/0031-9155\/60\/9\/3567"},{"key":"14","doi-asserted-by":"publisher","unstructured":"[14] G.J. Bootsma, F. Verhaegen, and D.A. Jaffray, \u201cEfficient scatter distribution estimation and correction in CBCT using concurrent Monte Carlo fitting,\u201d Med. Phys., vol.42, no.1, pp.54-68, Jan. 2015. DOI:10.1118\/1.4903260 10.1118\/1.4903260","DOI":"10.1118\/1.4903260"},{"key":"15","doi-asserted-by":"publisher","unstructured":"[16] P.G. Lale, \u201cThe examination of internal tissues, using gamma-ray scatter with a possible extension to megavoltage radiography,\u201d Phys. Med. Biol\/, vol.4, no.2, pp.159-167, 1959. DOI: 10.1088\/0031-9155\/4\/2\/305 10.1088\/0031-9155\/4\/2\/305","DOI":"10.1088\/0031-9155\/4\/2\/305"},{"key":"16","doi-asserted-by":"publisher","unstructured":"[17] J.J. Battista and M.J. Bronskill, \u201cCompton scatter imaging of transverse sections: An overall appraisal and evaluation for radiotherapy planning,\u201d Phys. Med. Biol., vol.26, no.1, pp.81-99, Jan. 1981. DOI:10.1088\/0031-9155\/26\/1\/009 10.1088\/0031-9155\/26\/1\/009","DOI":"10.1088\/0031-9155\/26\/1\/009"},{"key":"17","doi-asserted-by":"crossref","unstructured":"[18] S.J. Norton, \u201cCompton scattering tomography,\u201d J. Appl. Phys., vol.76, no.4, pp.2007-2015, Aug. 1994. DOI:10.1063\/1.357668 10.1063\/1.357668","DOI":"10.1063\/1.357668"},{"key":"18","doi-asserted-by":"publisher","unstructured":"[19] M.K. Nguyen, T.T. Truong, M. Morvidone, and H. Zaidi, \u201cScattered radiation emission imaging: Principles and applications,\u201d Journal of Biomedical Imaging, vol.2011, pp.13-28, June 2011. DOI:10.1155\/2011\/913893 10.1155\/2011\/913893","DOI":"10.1155\/2011\/913893"},{"key":"19","doi-asserted-by":"crossref","unstructured":"[20] F. Zhao, J.C. Schotland, and V.A. Markel, \u201cInversion of the star transform,\u201d Inverse Problems, vol.30, no.10, pp.105001-105032, Oct. 2014. DOI:10.1088\/0266-5611\/30\/10\/105001 10.1088\/0266-5611\/30\/10\/105001","DOI":"10.1088\/0266-5611\/30\/10\/105001"},{"key":"20","doi-asserted-by":"publisher","unstructured":"[21] R. Krylov and A. Katsevich, \u201cInversion of the broken ray transform in the case of energy-dependent attenuation,\u201d Phys. Med. Biol., vol.60, no.11, pp.4313-4334, May 2015. DOI:10.1088\/0031-9155\/60\/11\/4313 10.1088\/0031-9155\/60\/11\/4313","DOI":"10.1088\/0031-9155\/60\/11\/4313"},{"key":"21","doi-asserted-by":"publisher","unstructured":"[22] T.T. Truong and M.K. Nguyen, \u201cNew properties of the V-line Radon transform and their imaging applications,\u201d J. Phys. A: Math. Theor., vol.48, no.40, pp.405204-405232, Sept. 2015. DOI:10.1088\/1751-8113\/48\/40\/405204 10.1088\/1751-8113\/48\/40\/405204","DOI":"10.1088\/1751-8113\/48\/40\/405204"},{"key":"22","doi-asserted-by":"publisher","unstructured":"[23] J.B. Thaibault, K.D. Sauer, C.A. Bouman, and J. Hsieh, \u201cA three-dimensional statistical approach to improved image quality for multislice helical CT,\u201d Med. Phys., vol.34, no.11, pp.4526-4544, Oct. 2007. DOI:10.1118\/1.2789499 10.1118\/1.2789499","DOI":"10.1118\/1.2789499"},{"key":"23","doi-asserted-by":"crossref","unstructured":"[24] Z. Yu, J.B. Thaibault, C.A. Bouman, K.D. Sauer, and J. Hsieh, \u201cFast model-based X-ray CT reconstruction using spatially nonhomogeneous ICD Optimization,\u201d IEEE Trans. Image Process., vol.20, no.1, pp.161-175, Jan. 2011. DOI:10.1109\/TIP.2010.2058811 10.1109\/tip.2010.2058811","DOI":"10.1109\/TIP.2010.2058811"},{"key":"24","doi-asserted-by":"publisher","unstructured":"[25] K. Yasaka, M. Katsura, M. Akahane, J. Sato, I. Matsuda, and K. Ohtomo, \u201cModel-based iterative reconstruction for reduction of radiation dose in abdominopelvic CT: Comparison to adaptive statistical iterative reconstruction,\u201d SpringerPlus, vol.2, no.209, May 2013. DOI:10.1186\/2193-1801-2-209 10.1186\/2193-1801-2-209","DOI":"10.1186\/2193-1801-2-209"},{"key":"25","unstructured":"[26] D. Nagae and N. Toda, \u201cReconstruction accuracy of X-ray computed tomography introduced scattered X-rays measurement,\u201d IEICE Trans. Inf. &amp; Syst. (Japanese Edition), vol.J101-D, no.8, pp.1200-1208, Aug. 2018. Online ISSN:1881-0225"},{"key":"26","doi-asserted-by":"publisher","unstructured":"[27] M.Z. Alom, T.M. Taha, C. Yakopcic, S. Westberg, P. Sidike, M.S. Nasrin, M. Hasan, B.C. Van Essen, A.A.S. Awwal, and V.K. Asari,\u201cA state-of-the-art survey on deep learning theory and architectures,\u201d Electronics, vol.8, no.292, March 2019. DOI:10.3390\/electronics8030292 10.3390\/electronics8030292","DOI":"10.3390\/electronics8030292"},{"key":"27","doi-asserted-by":"publisher","unstructured":"[28] G. Wang, J.C. Ye, and B.D. Man, \u201cDeep learning for tomographic image reconstruction,\u201d Nat. Mach. Intell., vol.2, pp.737-748, Dec. 2020. DOI:10.1038\/s42256-020-00273-z 10.1038\/s42256-020-00273-z","DOI":"10.1038\/s42256-020-00273-z"},{"key":"28","doi-asserted-by":"publisher","unstructured":"[29] H. Shan, A. Padole, F. Homayounieh, U. Kruger, R.D. Khera, C. Nitiwarangkul, M.K. Kalra, and G. Wang, \u201cCompetitive performance of a modularized deep neural network compared to commercial algorithms for low-dose CT image reconstruction,\u201d Nat. Mach. Intell., vol.1, pp.269-276, June 2019. DOI:10.1038\/s42256-019-0057-9 10.1038\/s42256-019-0057-9","DOI":"10.1038\/s42256-019-0057-9"},{"key":"29","doi-asserted-by":"publisher","unstructured":"[30] S. Ito and N. Toda,\u201cImprovement of CT reconstruction using scattered X-rays,\u201d IEICE Trans. Inf. &amp; Syst., vol.E104-D, no.8, pp.1378-1385, Aug. 2021. DOI:10.1587\/transinf.2020EDP7241 10.1587\/transinf.2020edp7241","DOI":"10.1587\/transinf.2020EDP7241"},{"key":"30","doi-asserted-by":"publisher","unstructured":"[31] N. Toda, T. Nakagami, Y. Yamazaki, H. Yoshioka, and S. Koyama, \u201cUsing scattered X-rays to improve the estimation accuracy of attenuation coefficients: A fundamental analysis,\u201d IEICE Trans. Fundamentals, vol.E101-A, no.7, pp.1101-1114, July 2018. DOI:10.1587\/transfun.E101.A.1101 10.1587\/transfun.e101.a.1101","DOI":"10.1587\/transfun.E101.A.1101"},{"key":"31","unstructured":"[32] H. Cember and T.E. Johnson, \u201cInteraction of radiation with matter,\u201d Introduction to Health Physics, 4th ed., p.180, McGraw-Hill, New York, USA, 2009."},{"key":"32","unstructured":"[33] R.V. Hogg and J.W. McKean, \u201cMaximum likelihood Methods,\u201d Introduction to Mathematical Statistics, 8th ed., Peason, Boston, USA, 2019."},{"key":"33","doi-asserted-by":"crossref","unstructured":"[34] R.B. Manfrino, J.A.G. Ortega, and R.V. Delgado, \u201cNumerical inequalities,\u201d Inequalities, ch.1, Theorem 1.3.1, p.9, Birkha\u00e4user Verlag AG, Germany, 2009. 10.1007\/978-3-0346-0050-7_1","DOI":"10.1007\/978-3-0346-0050-7_1"},{"key":"34","doi-asserted-by":"crossref","unstructured":"[35] H. Hirayama, Y. Namito, and A. Bielajew, \u201cThe EGS5 code system, report 2005-8,\u201d High Energy Accelerator Research Organization, Tsukuba, Japan, 2009.","DOI":"10.2172\/877459"}],"container-title":["IEICE Transactions on Fundamentals of Electronics, Communications and Computer Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/transfun\/E108.A\/8\/E108.A_2024EAP1066\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T03:27:25Z","timestamp":1754105245000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/transfun\/E108.A\/8\/E108.A_2024EAP1066\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,1]]},"references-count":34,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1587\/transfun.2024eap1066","relation":{},"ISSN":["0916-8508","1745-1337"],"issn-type":[{"type":"print","value":"0916-8508"},{"type":"electronic","value":"1745-1337"}],"subject":[],"published":{"date-parts":[[2025,8,1]]},"article-number":"2024EAP1066"}}