{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T18:04:12Z","timestamp":1787162652548,"version":"build-2736575974"},"reference-count":33,"publisher":"Society of Physical Therapy Science","issue":"11","funder":[{"name":"JSPS KAKENHI","award":["JP24K14179"],"award-info":[{"award-number":["JP24K14179"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Phys Ther Sci"],"published-print":{"date-parts":[[2025]]},"DOI":"10.1589\/jpts.37.561","type":"journal-article","created":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T22:13:19Z","timestamp":1761948799000},"page":"561-566","source":"Crossref","is-referenced-by-count":3,"title":["Validation of heart rate measured by the consumer-level wearable device Fitbit: a cross-sectional observational study"],"prefix":"10.1589","volume":"37","author":[{"given":"Daisuke","family":"Higuchi","sequence":"first","affiliation":[{"name":"Department of Physical Therapy, Faculty of Health Care, Takasaki              University of Health and Welfare: 27 Nakaorui-machi, Takasaki-shi, Gunma 370-0033,              Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuko","family":"Takahashi","sequence":"additional","affiliation":[{"name":"Department of Physical Therapy, Faculty of Health Care, Takasaki              University of Health and Welfare: 27 Nakaorui-machi, Takasaki-shi, Gunma 370-0033,              Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigeya","family":"Tanaka","sequence":"additional","affiliation":[{"name":"Department of Physical Therapy, Faculty of Health Care, Takasaki              University of Health and Welfare: 27 Nakaorui-machi, Takasaki-shi, Gunma 370-0033,              Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yosuke","family":"Tomita","sequence":"additional","affiliation":[{"name":"Department of Physical Therapy, Faculty of Health Care, Takasaki              University of Health and Welfare: 27 Nakaorui-machi, Takasaki-shi, Gunma 370-0033,              Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"533","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1) Thanh              NX, Tanguay              RL, Manhas              KJ, et al.:            Economic burden of chronic pain in Alberta, Canada.            PLoS One, 2022, 17:            e0272638.","DOI":"10.1371\/journal.pone.0272638"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2) Geneen              LJ, Moore              RA, Clarke              C, et al.:            Physical activity and exercise for chronic pain in adults: an overview of            Cochrane Reviews. Cochrane Database Syst Rev,            2017, 4: CD011279.","DOI":"10.1002\/14651858.CD011279.pub2"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3) Ambrose              KR, Golightly              YM: Physical            exercise as non-pharmacological treatment of chronic pain: why and when.            Best Pract Res Clin Rheumatol, 2015, 29:            120\u2013130.","DOI":"10.1016\/j.berh.2015.04.022"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4) Kostadinovi\u0107              S,                Milovanovi\u0107              N, Jovanovi\u0107              J, et al.:            Efficacy of the lumbar stabilization and thoracic mobilization exercise            program on pain intensity and functional disability reduction in chronic low back pain            patients with lumbar radiculopathy: a randomized controlled trial.            J Back Musculoskelet Rehabil, 2020, 33:            897\u2013907.","DOI":"10.3233\/BMR-201843"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5) Rodr\u00edguez-Sanz              J,                Malo-Urri\u00e9s              M,                Corral-de-Toro              J, et al.:            Does the addition of manual therapy approach to a cervical exercise            program improve clinical outcomes for patients with chronic neck pain in short- and            mid-term? A randomized controlled trial. Int J Environ Res            Public Health, 2020, 17: 17.","DOI":"10.3390\/ijerph17186601"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6) Bat\u0131bay              S, K\u00fclc\u00fc              DG, Kaleo\u011flu              \u00d6, et al.:            Effect of Pilates mat exercise and home exercise programs on pain,            functional level, and core muscle thickness in women with chronic low back            pain. J Orthop Sci, 2021,            26: 979\u2013985.","DOI":"10.1016\/j.jos.2020.10.026"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7) Richards              J, Thorogood              M, Hillsdon              M, et al.:            Face-to-face versus remote and web 2.0 interventions for promoting            physical activity. Cochrane Database Syst Rev,            2013, 2013: CD010393.","DOI":"10.1002\/14651858.CD010393.pub2"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8) Shah              N, Costello              K, Mehta              A, et al.:            Applications of digital health technologies in knee osteoarthritis:            narrative review. JMIR Rehabil Assist Technol,            2022, 9: e33489.","DOI":"10.2196\/33489"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9) Fuller              D, Colwell              E, Low              J, et al.:            Reliability and validity of commercially available wearable devices for            measuring steps, energy expenditure, and heart rate: systematic review.            JMIR Mhealth Uhealth, 2020, 8:            e18694.","DOI":"10.2196\/18694"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10) Thiebaud              RS, Funk              MD, Patton              JC, et al.:            Validity of wrist-worn consumer products to measure heart rate and energy            expenditure. Digit Health, 2018,            4: 2055207618770322.","DOI":"10.1177\/2055207618770322"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11) Nelson              BW, Allen              NB: Accuracy of            consumer wearable heart rate measurement during an ecologically valid 24-hour period:            intraindividual validation study. JMIR Mhealth Uhealth,            2019, 7: e10828.","DOI":"10.2196\/10828"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12) Chevance              G,                Golaszewski              NM, Tipton              E, et al.:            Accuracy and precision of energy expenditure, heart rate, and steps            measured by combined-sensing fitbits against reference measures: systematic review and            meta-analysis. JMIR Mhealth Uhealth, 2022,            10: e35626.","DOI":"10.2196\/35626"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13) Lederer              L, Breton              A, Jeong              H, et al.:            The importance of data quality control in using fitbit device data from            the research program. JMIR Mhealth Uhealth,            2023, 11: e45103.","DOI":"10.2196\/45103"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14) Yano              S, Koohsari              MJ, Shibata              A, et al.:            Physical activity and sedentary behavior assessment: a laboratory-based            evaluation of agreement between commonly used ActiGraph and Omron            accelerometers. Int J Environ Res Public Health,            2019, 16: 16.","DOI":"10.3390\/ijerph16173126"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15) Gorny              AW, Liew              SJ, Tan              CS, et al.:            Fitbit charge HR wireless heart rate monitor: validation study conducted            under free-living conditions. JMIR Mhealth Uhealth,            2017, 5: e157.","DOI":"10.2196\/mhealth.8233"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16) Gustriansyah              R, Sensuse              DI, Ramadhan              A: A sales            prediction model adopted the recency-frequency-monetary concept.            Indones J Electr Eng Comput Sci, 2017, 6:            711\u2013720.","DOI":"10.11591\/ijeecs.v6.i3.pp711-720"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17) Muggeridge              DJ, Hickson              K, Davies              AV, et al.:            Measurement of heart rate using the Polar OH1 and Fitbit Charge 3            wearable devices in healthy adults during light, moderate, vigorous, and sprint-based            exercise: validation study. JMIR Mhealth Uhealth,            2021, 9: e25313.","DOI":"10.2196\/25313"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18) Held              NJ, Perrotta              AS, Mueller              T, et al.:            Agreement of the Apple Watch<sup>\u00ae<\/sup> and Fitbit Charge<sup>\u00ae<\/sup>            for recording step count and heart rate when exercising in water.            Med Biol Eng Comput, 2022, 60:            1323\u20131331.","DOI":"10.1007\/s11517-022-02536-w"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19) Nissen              M, Slim              S, J\u00e4ger              K, et al.:            Heart rate measurement accuracy of Fitbit Charge 4 and Samsung Galaxy            Watch Active2: device evaluation study. JMIR Form Res,            2022, 6: e33635.","DOI":"10.2196\/33635"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20) Bai              Y, Hibbing              P, Mantis              C, et al.:            Comparative evaluation of heart rate-based monitors: Apple Watch vs            Fitbit Charge HR. J Sports Sci, 2018,            36: 1734\u20131741.","DOI":"10.1080\/02640414.2017.1412235"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21) Tedesco              S, Sica              M, Ancillao              A, et al.:            Accuracy of consumer-level and research-grade activity trackers in            ambulatory settings in older adults. PLoS One,            2019, 14: e0216891.","DOI":"10.1371\/journal.pone.0216891"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22) Maeda              Y, Sekine              M, Tamura              T: Relationship            between measurement site and motion artifacts in wearable reflected            photoplethysmography. J Med Syst, 2011,            35: 969\u2013976.","DOI":"10.1007\/s10916-010-9505-0"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23) Dooley              EE,                Golaszewski              NM,                Bartholomew              JB: Estimating            accuracy at exercise intensities: a comparative study of self-monitoring heart rate and            physical activity wearable devices. JMIR Mhealth            Uhealth, 2017, 5: e34.","DOI":"10.2196\/mhealth.7043"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24) Jagim              AR,                Koch-Gallup              N, Camic              CL, et al.:            The accuracy of fitness watches for the measurement of heart rate and            energy expenditure during moderate intensity exercise. J Sports            Med Phys Fitness, 2021, 61:            205\u2013211.","DOI":"10.23736\/S0022-4707.20.11151-4"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25) Stahl              SE, An              HS, Dinkel              DM, et al.:            How accurate are the wrist-based heart rate monitors during walking and            running activities? Are they accurate enough? BMJ Open Sport            Exerc Med, 2016, 2: e000106.","DOI":"10.1136\/bmjsem-2015-000106"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26) Butts              NK, Knox              KM, Foley              TS: Energy            costs of walking on a dual-action treadmill in men and women.            Med Sci Sports Exerc, 1995, 27:            121\u2013125.","DOI":"10.1249\/00005768-199501000-00021"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27) Ghiani              G, Marongiu              E, Melis              F, et al.:            Body composition changes affect energy cost of running during 12 months            of specific diet and training in amateur athletes. Appl Physiol            Nutr Metab, 2015, 40:            938\u2013944.","DOI":"10.1139\/apnm-2015-0023"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28) Joyner              MJ, Dominelli              PB: Central            cardiovascular system limits to aerobic capacity. Exp            Physiol, 2021, 106:            2299\u20132303.","DOI":"10.1113\/EP088187"},{"key":"29","doi-asserted-by":"crossref","unstructured":"29) Morais              JE, Bragada              JA:            Relationship between oxygen uptake reserve and heart rate reserve in            young male tennis players: implications for physical fitness monitoring.            Int J Environ Res Public Health, 2022,          19: 19.","DOI":"10.3390\/ijerph192315780"},{"key":"30","doi-asserted-by":"crossref","unstructured":"30) Dorf              N, Maciejczyk              M: Skin            senescence-from basic research to clinical practice. Front Med            (Lausanne), 2024, 11: 1484345.","DOI":"10.3389\/fmed.2024.1484345"},{"key":"31","doi-asserted-by":"crossref","unstructured":"31) Bentov              I, Reed              MJ: The effect            of aging on the cutaneous microvasculature. Microvasc            Res, 2015, 100:            25\u201331.","DOI":"10.1016\/j.mvr.2015.04.004"},{"key":"32","doi-asserted-by":"crossref","unstructured":"32) Kim              C, Song              JH, Kim              SH: Validation            of wearable digital devices for heart rate measurement during exercise test in patients            with coronary artery disease. Ann Rehabil Med,            2023, 47: 261\u2013271.","DOI":"10.5535\/arm.23019"},{"key":"33","doi-asserted-by":"crossref","unstructured":"33) Shcherbina              A, Mattsson              CM, Waggott              D, et al.:            Accuracy in wrist-worn, sensor-based measurements of heart rate and            energy expenditure in a diverse cohort. J Pers Med,            2017, 7: 7.","DOI":"10.3390\/jpm7020003"}],"container-title":["Journal of Physical Therapy Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jpts\/37\/11\/37_2025-079\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T04:18:26Z","timestamp":1761970706000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jpts\/37\/11\/37_2025-079\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025]]},"references-count":33,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1589\/jpts.37.561","relation":{},"ISSN":["0915-5287","2187-5626"],"issn-type":[{"value":"0915-5287","type":"print"},{"value":"2187-5626","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025]]},"article-number":"2025-079"}}