{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T15:45:40Z","timestamp":1759160740216},"reference-count":25,"publisher":"FapUNIFESP (SciELO)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Braz. Dent. J."],"published-print":{"date-parts":[[2013]]},"abstract":"<jats:p>This study evaluated the casting accuracy of crown margins and metal-ceramic shear bond strength (SBS) of pure titanium injected into casting molds made using 2 investment types at 3 mold temperatures. Sixty crown (30-degree beveled finish line) and 60 cylinder (5\u2005mm diameter \u00d7 8\u2005mm high) patterns were divided into 6 groups (n=10), and cast using a phosphate-bonded investment (P) and a magnesium oxide-bonded investment (U), at 400\u00b0C (groups P400 and U400), 550\u00b0C (groups P550 and U550) and 700\u00b0C (groups P700 and U700) mold temperatures. Crown margins were recorded in impression material, the degree of marginal rounding was measured and margin length deficiencies (\u00b5m) were calculated. Titanium-ceramic specimens were prepared using Triceram ceramic (2\u2005mm high) and SBS was tested. Failure modes were assessed by optical microscopy. Data were subjected to two-way ANOVA and Tukey's HSD test (\u03b1=0.05). For casting accuracy, expressed by marginal deficiency (\u00b5m), investment U provided more accurate results (64 \u00b1 11) than P (81 \u00b1 23) (p&lt;0.001). The increase in temperature resulted in different effects for the tested investments (p&lt;0.001), as it provided better casting accuracy for U700 (55 \u00b1 7) and worse for P700 (109 \u00b1 18). Casting accuracy at 700\u00b0C (82 \u00b1 31) was significantly different from 400\u00b0C (69 \u00b1 9) and 550\u00b0C (68 \u00b1 9) (p&lt;0.05). For SBS, there was no significant differences among the groups for factors investment (p=0.062) and temperature (p=0.224), or for their interaction (p=0.149). Investment U provided better casting accuracy than investment P. The SBS was similar for all combinations of investments and temperatures.<\/jats:p>","DOI":"10.1590\/0103-6440201302042","type":"journal-article","created":{"date-parts":[[2013,8,27]],"date-time":"2013-08-27T12:57:52Z","timestamp":1377608272000},"page":"40-46","source":"Crossref","is-referenced-by-count":5,"title":["Effect of investment type and mold temperature on casting accuracy and titanium-ceramic bond"],"prefix":"10.1590","volume":"24","author":[{"given":"M\u00f4nica Barbosa","family":"Leal","sequence":"first","affiliation":[{"name":"UFS - Federal University of Sergipe,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Val\u00e9ria Oliveira","family":"Pagnano","sequence":"additional","affiliation":[{"name":"USP - University of S\u00e3o Paulo,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Osvaldo Luiz","family":"Bezzon","sequence":"additional","affiliation":[{"name":"USP - University of S\u00e3o Paulo,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"530","reference":[{"key":"ref1","first-page":"130","article-title":"A castability standard for alloys used in restorative dentistry","volume":"8","author":"Brockhurst PJ","year":"1983","journal-title":"Oper Dent"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"165","DOI":"10.3109\/00016358609026569","article-title":"Evaluation of the castability of four different alternative alloys by measuring the marginal sharpness","volume":"44","author":"Bessing C","year":"1986","journal-title":"Acta Odontol Scand"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1016\/0022-3913(93)90098-9","article-title":"Allergic sensitivity to several base metals: a clinical report","volume":"69","author":"Bezzon OL","year":"1993","journal-title":"J Prosthet Dent"},{"key":"ref4","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/S0022-3913(07)60143-7","article-title":"The castability of pure titanium compared with Ni-Cr and Ni-Cr-Be alloys","volume":"98","author":"Paulino SM","year":"2007","journal-title":"J Prosthet Dent"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.prosdent.2005.11.004","article-title":"Influence of investment type and sprue number on the casting accuracy of titanium crown margins","volume":"95","author":"Leal MB","year":"2006","journal-title":"J Prosthet Dent"},{"key":"ref6","first-page":"401","article-title":"Titanium for prosthodontic applications: a review of the literature","volume":"27","author":"Wang RR","year":"1996","journal-title":"Quintessence Int"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/S0300-5712(96)00072-3","article-title":"Influence of surface oxidation of titanium on adhesion","volume":"26","author":"Taira Y","year":"1998","journal-title":"J Dent"},{"key":"ref8","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1177\/00220345010800030101","article-title":"Fusing of dental ceramics to titanium","volume":"80","author":"K\u00f6n\u00f6nen M","year":"2001","journal-title":"J Dent Res"},{"key":"ref9","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/0109-5641(89)90093-6","article-title":"Studies of Ti alloys for dental castings","volume":"5","author":"Taira M","year":"1989","journal-title":"Dent Mater"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"1213","DOI":"10.1016\/j.dental.2011.08.002","article-title":"Effect of surface treatments on adhesion of low-fusing porcelain to titanium as determined by strain energy release rate","volume":"27","author":"Elsaka SE","year":"2011","journal-title":"Dent Mater"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"1800","DOI":"10.1177\/00220345900690120301","article-title":"Casting pure titanium into commercial phosphate-bonded SiO2 investment molds","volume":"69","author":"Takahashi J","year":"1990","journal-title":"J Dent Res"},{"key":"ref12","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/0109-5641(93)90098-B","article-title":"Mold filling and porosity in castings of titanium","volume":"9","author":"Her\u00f8 H","year":"1993","journal-title":"Dent Mater"},{"key":"ref13","first-page":"33","article-title":"Interfacial reactions of cast titanium with mold materials","volume":"11","author":"Wang RR","year":"1998","journal-title":"Int J Prosthodont"},{"key":"ref14","doi-asserted-by":"crossref","first-page":"301","DOI":"10.4012\/dmj.17.301","article-title":"Effects of magnesia and potassium sulfate on gypsum-bonded alumina dental investment for high-fusing casting","volume":"17","author":"Yan M","year":"1998","journal-title":"Dent Mater J"},{"key":"ref15","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1016\/j.prosdent.2005.09.017","article-title":"The effect of investment material type on the contamination zone and mechanical properties of commercially pure titanium castings","volume":"94","author":"Eliopoulos D","year":"2005","journal-title":"J Prosthet Dent"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.prosdent.2007.01.005","article-title":"The effects of different types of investments on the alpha-case layer of titanium castings","volume":"97","author":"Guilin Y","year":"2007","journal-title":"J Prosthet Dent"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1016\/j.dental.2005.09.004","article-title":"The effect of mold temperature on castability of CPTi and Ti-6Al-4V castings into phosphate bonded investment materials","volume":"22","author":"Oliveira PCG","year":"2006","journal-title":"Dent Mater"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"256","DOI":"10.4012\/dmj.14.256","article-title":"Enhancement of titanium denture frame model: mold temperature and spruing factors","volume":"14","author":"Vidovic Y","year":"1995","journal-title":"Dent Mater J"},{"key":"ref19","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1016\/j.prosdent.2004.03.033","article-title":"Evaluation of shear bond strength at the interface of two porcelains and pure titanium injected into the casting mold at three different temperatures","volume":"91","author":"Bondioli IM","year":"2004","journal-title":"J Prosthet Dent"},{"key":"ref20","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1016\/S0022-3913(96)90244-9","article-title":"Designs of bond strength tests for metal-ceramic complexes: review of the literature","volume":"75","author":"Hammad IA","year":"1996","journal-title":"J Prosthet Dent"},{"key":"ref21","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1177\/00220345800590030901","article-title":"Comparative evaluation of ceramic-metal bond tests using finite element stress analysis","volume":"59","author":"Anusavice KJ","year":"1980","journal-title":"J Dent Res"},{"key":"ref22","series-title":"ISO 9693:1999\/Amd.1:2005. Metal-ceramic dental restorative systems"},{"key":"ref23","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1016\/S0109-5641(98)00039-6","article-title":"Thermal stresses in metal-ceramic specimens for the ISO crack initiation test (three-point flexure bond test)","volume":"14","author":"Lenz J","year":"1998","journal-title":"Dent Mater"},{"key":"ref24","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1016\/j.dental.2008.06.008","article-title":"The effect of a ceramic coating on the cpTi-porcelain bond strength","volume":"25","author":"Papadopoulos TD","year":"2009","journal-title":"Dent Mater"},{"key":"ref25","series-title":"ISO 11405:1994. Dental materials \u00e2\u20ac\u201c Guidance on testing of adhesion to tooth structure"}],"container-title":["Brazilian Dental Journal"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/pdf\/bdj\/v24n1\/0103-6440-bdj-24-01-40.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,5,27]],"date-time":"2017-05-27T09:02:30Z","timestamp":1495875750000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S0103-64402013000100040&lng=en&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2013]]}},"alternative-id":["S0103-64402013000100040"],"URL":"https:\/\/doi.org\/10.1590\/0103-6440201302042","relation":{},"ISSN":["0103-6440"],"issn-type":[{"value":"0103-6440","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013]]}}}