{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,7]],"date-time":"2025-06-07T12:03:32Z","timestamp":1749297812084,"version":"3.37.3"},"reference-count":25,"publisher":"FapUNIFESP (SciELO)","issue":"3","license":[{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"am","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Braz. Dent. J."],"abstract":"<jats:p>Abstract In the RLT (Rapid Layer Technology), veneering ceramic and framework are fabricated by computer-aided design\/computer-aided manufacturing (CAD\/CAM) and then cemented to obtain the restoration. This study aimed to evaluate the effect of the thickness of veneering ceramic manufactured by the RLT technique on the fracture resistance (FR) of bilayer crowns with zirconia frameworks. Twenty zirconia frameworks and twenty feldspathic posterior crowns with two different veneering ceramic occlusal thicknesses (1mm=TF1; 2mm=TF2) were manufactured using CAD\/CAM system. The specimens were luted to an epoxy resin abutment with resin cement and mechanically cycled (200N and 4.5\u00d7105 Pa, 37\u00b0C, 2\u00d7106 cycles, 3Hz). The FR test was performed (10kN, 0.5mm\/min), and the specimens were analyzed in a stereomicroscope. For the stress analysis (finite element analysis, FEA), a 10kN load was equal to the in vitro test, and the principal stress was evaluated. The FR data were analyzed by Student\u2019s t-test and Weibull's analysis. The thickness influenced the FR of bilayer crowns. The FR was higher in the TF2 than in the TF1 group. The TF2 group presented the highest characteristic strength compared to the group TF1. The predominant type of failure was delamination. The FEA showed higher stress concentrations below the loading application point at the veneering cement interface in the 1-mm-thick model. The bilayer crowns manufactured using the approach of 2mm of veneering ceramic promoted higher FR compared to the group with 1mm veneering ceramic. Also, the FEA showed that the veneer ceramic thickness has an effect on stress distribution in zirconia-based bilayer crowns.<\/jats:p>","DOI":"10.1590\/0103-6440202104163","type":"journal-article","created":{"date-parts":[[2021,11,8]],"date-time":"2021-11-08T12:15:15Z","timestamp":1636373715000},"page":"44-55","source":"Crossref","is-referenced-by-count":4,"title":["CAD-FEA modeling and fracture resistance of bilayer zirconia crowns manufactured by the rapid layer technology"],"prefix":"10.1590","volume":"32","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6858-7950","authenticated-orcid":false,"given":"Julia Magalh\u00e3es Costa","family":"Lima","sequence":"first","affiliation":[{"name":"S\u00e3o Paulo State University, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6095-6819","authenticated-orcid":false,"given":"Anna Karina Figueiredo","family":"Costa","sequence":"additional","affiliation":[{"name":"S\u00e3o Paulo State University, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9350-9679","authenticated-orcid":false,"given":"Lilian Costa","family":"Anami","sequence":"additional","affiliation":[{"name":"S\u00e3o Paulo State University, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7117-8250","authenticated-orcid":false,"given":"Karina Barbosa","family":"Souza","sequence":"additional","affiliation":[{"name":"S\u00e3o Paulo State University, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4153-3279","authenticated-orcid":false,"given":"Nathalia Ramos da","family":"Silva","sequence":"additional","affiliation":[{"name":"Federal University of Rio Grande do Norte, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0752-6294","authenticated-orcid":false,"given":"Renata Marques de Melo","family":"Marinho","sequence":"additional","affiliation":[{"name":"S\u00e3o Paulo State University, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5707-7565","authenticated-orcid":false,"given":"Alexandre Luis Souto","family":"Borges","sequence":"additional","affiliation":[{"name":"S\u00e3o Paulo State University, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0077-3161","authenticated-orcid":false,"given":"Marco Antonio","family":"Bottino","sequence":"additional","affiliation":[{"name":"S\u00e3o Paulo State University, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9623-6098","authenticated-orcid":false,"given":"Mutlu","family":"\u00d6zcan","sequence":"additional","affiliation":[{"name":"University of Zurich, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0856-7178","authenticated-orcid":false,"given":"Rodrigo Oth\u00e1vio Assun\u00e7\u00e3o","family":"Souza","sequence":"additional","affiliation":[{"name":"Federal University of Rio Grande do Norte, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"530","published-online":{"date-parts":[[2021,6]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1016\/j.prosdent.2018.04.020","article-title":"Randomized controlled clinical trial of digital and conventional workflows for the fabrication of zirconia-ceramic posterior fixed partial dentures. Part II: Time efficiency of CAD-CAM versus conventional laboratory procedures","volume":"121","author":"M\u00fchlemann S","year":"2019","journal-title":"J Prosthet Dent"},{"key":"ref2","series-title":"J Prosthodont Res","first-page":"208","volume":"58","author":"Li RW","year":"2014"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"3","DOI":"10.2341\/16-350-T","article-title":"Ultrathin Monolithic Zirconia Veneers: Reality or Future? Report of a Clinical Case and One-year Follow-up","volume":"43","author":"Souza R","year":"2018","journal-title":"Oper Dent"},{"key":"ref4","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1590\/0103-6440201902780","article-title":"Restorative Possibilities Using Zirconia Ceramics for Single Crowns","volume":"30","author":"Felberg RV","year":"2019","journal-title":"Braz Dent J"},{"key":"ref5","first-page":"603","article-title":"All-ceramic or metal-ceramic tooth-supported fixed dental prostheses (FDPs)? A systematic review of the survival and complication rates","volume":"31","author":"Sailer I","year":"2015","journal-title":"Part I: Single crowns (SCs). Dent Mater"},{"key":"ref6","doi-asserted-by":"crossref","first-page":"387","DOI":"10.2341\/16-247-L","article-title":"Masking Colored Substrates Using Monolithic and Bilayer CAD-CAM Ceramic Structures","volume":"42","author":"Basso GR","year":"2017","journal-title":"Oper Dent"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1007\/s00784-017-2142-y","article-title":"Clinical evaluation of zirconia-based all-ceramic single crowns: an up to 12-year retrospective cohort study","volume":"22","author":"Miura S","year":"2018","journal-title":"Clin Oral Investig"},{"key":"ref8","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.jdent.2017.07.004","article-title":"Zirconia-based versus metal-based single crowns veneered with overpressing ceramic for restoration of posterior endodontically treated teeth: 5-year results of a randomized controlled clinical study","volume":"65","author":"Monaco C","year":"2017","journal-title":"J Dent"},{"key":"ref9","doi-asserted-by":"crossref","first-page":"948","DOI":"10.1016\/j.dental.2011.05.009","article-title":"The effect of porcelain thickness and surface liner application on the fracture behavior of a ceramic system","volume":"27","author":"Benetti P","year":"2011","journal-title":"Dent Mater"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"1132","DOI":"10.1016\/j.dental.2013.08.206","article-title":"Time-dependent fracture probability of bilayer, lithium-disilicate-based, glass-ceramic, molar crowns as a function of core\/veneer thickness ratio and load orientation","volume":"29","author":"Anusavice KJ","year":"2013","journal-title":"Dent Mater"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1016\/j.prosdent.2017.11.013","article-title":"Does veneering technique affect the flexural strength or load-to-failure of bilayer Y-TZP? A systematic review and meta-analysis","volume":"119","author":"Marchionatti AME","year":"2018","journal-title":"J Prosthet Dent"},{"key":"ref12","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1016\/j.dental.2018.11.034","article-title":"Influence of residual thermal stresses on the edge chipping resistance of PFM and veneered zirconia structures: Experimental and FEA study","volume":"35","author":"Tanaka CB","year":"2019","journal-title":"Dent Mater"},{"key":"ref13","doi-asserted-by":"crossref","first-page":"1668","DOI":"10.1016\/j.actbio.2008.12.016","article-title":"Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and \ufb01xed partial dentures","volume":"5","author":"Swain MV","year":"2009","journal-title":"Acta Biomater"},{"key":"ref14","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1016\/j.dental.2014.02.020","article-title":"Influence of thermal gradients on stress state of veneered restorations","volume":"30","author":"Benetti P","year":"2014","journal-title":"Dent Mater"},{"key":"ref15","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1111\/eos.12604","article-title":"In vitro lifetime of zirconium dioxide-based crowns veneered using Rapid Layer Technology","volume":"127","author":"Riedel C","year":"2019","journal-title":"Eur J Oral Sci"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1111\/joor.12061","article-title":"In vitro chipping behaviour of all-ceramic crowns with a zirconia framework and feldspathic veneering: comparison of CAD\/CAM-produced veneer with manually layered veneer","volume":"40","author":"Schmitter M","year":"2013","journal-title":"J Oral Rehabil"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.dental.2013.10.008","article-title":"Effect on in vitro fracture resistance of the technique used to attach lithium disilicate ceramic veneer to zirconia frameworks","volume":"30","author":"Schmitter M","year":"2014","journal-title":"Dent Mater"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1016\/j.dental.2011.11.008","article-title":"Influence of veneer thickness on residual stress profile in veneering ceramic: measurement by hole-drilling","volume":"28","author":"Mainjot AK","year":"2012","journal-title":"Dent Mater"},{"key":"ref19","doi-asserted-by":"crossref","first-page":"1063","DOI":"10.1016\/j.dental.2013.07.019","article-title":"Effects of thickness, processing technique, and cooling rate protocol on the flexural strength of a bilayer ceramic system","volume":"29","author":"Lima JM","year":"2013","journal-title":"Dent Mater"},{"key":"ref20","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1080\/23337931.2017.1403288","article-title":"Fracture strength of veneered translucent zirconium dioxide crowns with different porcelain thicknesses","volume":"3","author":"Bakitian F","year":"2017","journal-title":"Acta Biomater Odontol Scand"},{"key":"ref21","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1016\/S0022-3913(10)60129-1","article-title":"Development of a clinically validated bulk failure test for ceramic crowns","volume":"104","author":"Kelly J R","year":"2010","journal-title":"J Prosthet Dent"},{"key":"ref22","first-page":"115","article-title":"Fracture resistance of teeth restored with dentin-bonded crowns: the effect of increased tooth preparation","volume":"27","author":"Burke FJ","year":"1996","journal-title":"Quintessence Int"},{"key":"ref23","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1111\/jopr.13008","article-title":"Effect of thermomechanical and static loading on the load to fracture of metal-ceramic, monolithic and veneered zirc\u00f4nia posterior fixed partial dentures","volume":"28","author":"Lopez-Suarez C","year":"2019","journal-title":"J Prosthodont"},{"key":"ref24","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1080\/17436753.2018.1507428","article-title":"Zirconia ceramic fixed partial dentures after cyclic fatigue tests and clinical evaluation: a systematic review","volume":"118","author":"Gjurin SZ","year":"2019","journal-title":"Adv Appl Ceram"},{"key":"ref25","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1111\/j.1600-0501.2011.02224.x","article-title":"Fracture strength of yttria-stabilized tetragonal zirconia polycrystals crowns with different design: an in vitro study","volume":"23","author":"Larsson C","year":"2012","journal-title":"Clin Oral Impl Res"}],"container-title":["Brazilian Dental Journal"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/pdf\/bdj\/v32n3\/1806-4760-bdj-32-03-44.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,12]],"date-time":"2023-11-12T10:45:27Z","timestamp":1699785927000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S0103-64402021000300044&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6]]},"references-count":25,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2021,6]]}},"alternative-id":["S0103-64402021000300044"],"URL":"https:\/\/doi.org\/10.1590\/0103-6440202104163","relation":{},"ISSN":["1806-4760","0103-6440"],"issn-type":[{"type":"electronic","value":"1806-4760"},{"type":"print","value":"0103-6440"}],"subject":[],"published":{"date-parts":[[2021,6]]}}}