{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T20:23:10Z","timestamp":1793305390868,"version":"4.5.0"},"reference-count":25,"publisher":"FapUNIFESP (SciELO)","issue":"6","license":[{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"am","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Braz. Dent. J."],"abstract":"<jats:p>Abstract This study aims to evaluate the fatigue resistance of monolithic zirconia (Yz) and multilayer ceramic structures using the CAD-on technique in different thicknesses. Fifty (N=50) standardized single crowns preparations were made in fiberglass-reinforced epoxy resin (NEMA grade G10), digitalized, and restorations were machined in CAD-CAM, composing 5 groups (n= 10): Control: 1.5 mm (milled zirconia framework + manual layered porcelain); Yz monolithic 1.5 mm; Yz monolithic 1.0 mm; CAD-on 1.5 mm; and CAD-on 1.0 mm (milled zirconia framework 0.5 mm thickness bonded by a low fuse ceramic to a milled lithium disilicate layer of 1.0 mm or 0.5 mm, respectively). The G10 bases were conditioned with 10% hydrofluoric acid; the crowns were air abraded with 110 \u03bcm alumina particles; and then luted onto each other with self-adhesive resin cement. A cyclic fatigue test was performed (initial load: 400N for 10,000 cycles, frequency of 20 Hz, step size of 200N) until failure, and the data was submitted to a survival statistical analysis. No failures were observed at Yz monolithic 1.5 mm. High and similar performance was observed for Cad-On groups and Yz monolithic 1.0 mm. The control group depicted the worst behavior. The Weibull modulus of CAD-on 1.5 mm was higher than the control while being similar to the other conditions. Both the monolithic systems and the CAD-on technique showed high and similar fatigue fracture behavior and survival rates, which were also higher than the control bilayer system. Both systems reduced the occurrence of delamination failures, making them suitable for clinical use.<\/jats:p>","DOI":"10.1590\/0103-6440202305687","type":"journal-article","created":{"date-parts":[[2023,12,22]],"date-time":"2023-12-22T10:05:57Z","timestamp":1703239557000},"page":"150-159","source":"Crossref","is-referenced-by-count":5,"title":["Fatigue resistance of monolithic and multilayer zirconia crowns using veneer layering or CAD-on technique"],"prefix":"10.1590","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9644-0486","authenticated-orcid":false,"given":"Alvim Gustavo Fasolin","family":"Tomm","sequence":"first","affiliation":[{"name":"Atitus Educa\u00e7\u00e3o,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7702-0013","authenticated-orcid":false,"given":"Pablo Soares","family":"Machado","sequence":"additional","affiliation":[{"name":"Federal University of Santa Maria,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2159-3787","authenticated-orcid":false,"given":"Lucas Saldanha da","family":"Rosa","sequence":"additional","affiliation":[{"name":"Federal University of Santa Maria,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9077-9067","authenticated-orcid":false,"given":"Gabriel Kalil Rocha","family":"Pereira","sequence":"additional","affiliation":[{"name":"Federal University of Santa Maria,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2392-1836","authenticated-orcid":false,"given":"Aloisio Oro","family":"Spazzin","sequence":"additional","affiliation":[{"name":"Atitus Educa\u00e7\u00e3o,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3997-9370","authenticated-orcid":false,"given":"Rodrigo","family":"Alessandretti","sequence":"additional","affiliation":[{"name":"Atitus Educa\u00e7\u00e3o,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"530","published-online":{"date-parts":[[2023]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","DOI":"10.14219\/jada.archive.2008.0359","article-title":"Dental ceramics: what is this stuff anyway?","volume":"139","author":"Kelly JR","year":"2008","journal-title":"J Am Dent Assoc"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"162","DOI":"10.2186\/jpr.JPOR_2019_553","article-title":". Influence of zirconia surface treatments of a bilayer restorative assembly on the fatigue performance","volume":"65","author":"Machado PS","year":"2021","journal-title":"J Prosthodont Res"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"145","DOI":"10.3109\/00016357.2013.822098","article-title":"Fracture strength of monolithic all-ceramic crowns made of high translucent yttrium oxide-stabilized zirconium dioxide compared to porcelain-veneered crowns and lithium disilicate crowns","volume":"72","author":"Johansson C","year":"2014","journal-title":"Acta Odontol Scand"},{"key":"ref4","article-title":"Fracture strength of aged monolithic and bilayer zirconia-based crowns","author":"Lameira DP","year":"2015","journal-title":"Biomed Res Int"},{"issue":"21","key":"ref5","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1111\/clr.13863","article-title":"A systematic review and meta-analysis evaluating the survival, the failure, and the complication rates of veneered and monolithic all-ceramic implant-supported single crowns","volume":"32","author":"Pjetursson BE","year":"2021","journal-title":"Clin Oral Implants Res"},{"key":"ref6","article-title":"Fatigue performance of distinct CAD\/CAM dental ceramics","volume":"103","author":"Guilardi LF","year":"2020","journal-title":"J Mech Behav Biomed Mater"},{"key":"ref7","first-page":"441","article-title":"Three generations of zirconia: From veneered to monolithic","volume":"48","author":"Stawarczyk B","year":"2017","journal-title":"Part II. Quintessence Int"},{"issue":"496","key":"ref8","first-page":"e1","article-title":"Masking ability of implant abutment substrates by using different ceramic restorative systems","volume":"128","author":"Soares PM","year":"2022","journal-title":"J Prosthet Dent"},{"key":"ref9","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1016\/j.prosdent.2016.02.009","article-title":"Fracture toughness of two lithium disilicate dental ceramics","volume":"116","author":"Alkadi L","year":"2016","journal-title":"J Prosthet Dent"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.jmbbm.2018.12.010","article-title":"Lithium disilicate glass-ceramic vs translucent zirconia polycrystals bonded to distinct substrates: fatigue failure load, number of cycles for failure, survival rates, and stress distribution","volume":"91","author":"Pereira GKR","year":"2019","journal-title":"J Mech Behav Biomed Mater"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"1453","DOI":"10.1016\/j.dental.2015.09.013","article-title":"Flexural strength and reliability of monolithic and trilayer ceramic structures obtained by the CAD-on technique","volume":"31","author":"Basso GR","year":"2015","journal-title":"Dent Mater"},{"key":"ref12","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1590\/0103-6440201902574","article-title":"Fracture Load and Failure Mode of CAD-on Ceramic Structures","volume":"30","author":"Alessandretti R","year":"2019","journal-title":"Braz Dent J"},{"key":"ref13","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1111\/jerd.12877","article-title":"Prospective 5-year clinical evaluation of posterior zirconia fixed dental prostheses veneered with milled lithium disilicate (CADon)","volume":"34","author":"Blatz MB","year":"2022","journal-title":"J Esthet Restor Dent"},{"key":"ref14","doi-asserted-by":"crossref","first-page":"E244","DOI":"10.2341\/18-083-L","article-title":"Mechanical Behavior of Ceramic Monolithic Systems With Different Thicknesses","volume":"44","author":"Longhini D","year":"2019","journal-title":"Oper Dent"},{"key":"ref15","doi-asserted-by":"crossref","first-page":"2777","DOI":"10.1007\/s00784-018-2717-2","article-title":"Fracture load of CAD\/CAM-fabricated and 3D-printed composite crowns as a function of material thickness","volume":"23","author":"Zimmermann M","year":"2019","journal-title":"Clin Oral Investig"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"602","DOI":"10.3109\/00016357.2015.1007479","article-title":"Fracture resistance of monolithic zirconia molar crowns with reduced thickness","volume":"73","author":"Nakamura K","year":"2015","journal-title":"Acta Odontol Scand"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/j.jmbbm.2019.03.005","article-title":"CAD-CAM milled versus pressed lithium-disilicate monolithic crowns adhesively cemented after distinct surface treatments: Fatigue performance and ceramic surface characteristics","volume":"94","author":"Schestatsky R","year":"2019","journal-title":"J Mech Behav Biomed Mater"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1016\/S0022-3913(10)60129-1","article-title":"Development of a clinically validated bulk failure test for ceramic crowns","volume":"104","author":"Kelly JR","year":"2010","journal-title":"J Prosthet Dent"},{"key":"ref19","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1111\/jopr.12175","article-title":"Finite element analysis of the influence of geometry and design of zirconia crowns on stress distribution","volume":"24","author":"Anami LC","year":"2015","journal-title":"J Prosthodont"},{"key":"ref20","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.prosdent.2020.03.032","article-title":"Fatigue performance of adhesively luted glass or polycrystalline CAD-CAM monolithic crowns","volume":"126","author":"Alves DM","year":"2021","journal-title":"J Prosthet Dent"},{"key":"ref21","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1002\/jbm.b.30195","article-title":"Deep-penetrating conical cracks in brittle layers from hydraulic cyclic contact","volume":"73","author":"Zhang Y","year":"2005","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"ref22","doi-asserted-by":"crossref","first-page":"147","DOI":"10.11607\/ijp.3608","article-title":"Failure modes and fracture origins of porcelain veneers on bilayer dental crowns","volume":"27","author":"Liu Y","year":"2014","journal-title":"Int J Prosthodont"},{"key":"ref23","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1115\/1.4010337","article-title":"A statistical distribution function of wide applicability","volume":"18","author":"Weibull W","year":"1951","journal-title":"J Appl Mech"},{"key":"ref24","doi-asserted-by":"crossref","first-page":"188","DOI":"10.34172\/joddd.2021.032","article-title":"Effect of three different veneering techniques on the stress distribution and in vitro fatigue behavior of core-veneer all-ceramic fixed partial dentures","volume":"15","author":"Borges ALS","year":"2021","journal-title":"J Dent Res Dent Clin Dent Prospects"},{"key":"ref25","article-title":"Effects of cement thickness and bonding on the failure loads of CAD\/CAM ceramic crowns: multi-physics FEA modeling and monotonic testing","volume":"28","author":"May LG","year":"2012","journal-title":"Dent Mater"}],"container-title":["Brazilian Dental Journal"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_pdf&pid=S0103-64402023000600150&tlng=en","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,22]],"date-time":"2023-12-22T10:06:10Z","timestamp":1703239570000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S0103-64402023000600150&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023]]},"references-count":25,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2023]]}},"alternative-id":["S0103-64402023000600150"],"URL":"https:\/\/doi.org\/10.1590\/0103-6440202305687","relation":{},"ISSN":["1806-4760","0103-6440"],"issn-type":[{"value":"1806-4760","type":"electronic"},{"value":"0103-6440","type":"print"}],"subject":[],"published":{"date-parts":[[2023]]}}}