{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T15:04:48Z","timestamp":1753887888486,"version":"3.41.2"},"reference-count":32,"publisher":"FapUNIFESP (SciELO)","license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"am","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Braz. Dent. J."],"abstract":"<jats:p>Abstract Rehabilitation of edentulous atrophic mandibles involves the placement of implants in the anterior segment of the mandible. The primary stability of these implants can be improved using the base of the mandible as complementary anchorage (bicorticalization). This study aimed to analyze the biomechanics of atrophic mandibles rehabilitated with monocortical or bicortical implants. Two three-dimensional virtual models of edentulous mandibles with severe atrophy were prepared. Four monocortical implants were placed in one model (McMM), and four bicortical implants were placed in the other (BcMM). An implant-supported total prosthesis was prepared for each model. Then, a total axial load of 600 N was applied to the posterior teeth, and its effects on the models were analyzed using finite element analysis. The highest compressive stresses were concentrated in the cervical region of the implants in the McMM (-32.562 Mpa); in the BcMM, compressive stresses were distributed in the upper and lower cortex of the mandible, with increased compressive stresses at the distal implants (-63.792 Mpa). Thus, we conclude that axial loading forces are more uniformly distributed in the peri-implant bone when using monocortical implants and concentrated in the apical and cervical regions of the peri-implant bone when using bicortical implants.<\/jats:p>","DOI":"10.1590\/0103-6440202405621","type":"journal-article","created":{"date-parts":[[2024,6,24]],"date-time":"2024-06-24T10:39:33Z","timestamp":1719225573000},"source":"Crossref","is-referenced-by-count":1,"title":["Analysis of the atrophic mandible rehabilitated with fixed total prosthesis on mono or bicortical implants"],"prefix":"10.1590","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4755-1718","authenticated-orcid":false,"given":"Fabricia Carla Martins Bezerra","family":"Garutti","sequence":"first","affiliation":[{"name":"Federal University of Mato Grosso,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9319-3179","authenticated-orcid":false,"given":"Roberto Brunow","family":"Lehmann","sequence":"additional","affiliation":[{"name":"Federal Fluminense University,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0539-530X","authenticated-orcid":false,"given":"Ivan Onone","family":"Gialain","sequence":"additional","affiliation":[{"name":"Universidade de Cuiab\u00e1,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7456-9775","authenticated-orcid":false,"given":"Fernando Fusari Bento de","family":"Lima","sequence":"additional","affiliation":[{"name":"Federal University of Mato Grosso,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"530","published-online":{"date-parts":[[2024]]},"reference":[{"issue":"7","key":"ref1","article-title":"Periodontics versus Implantodontics: A short review of the dilemma of tooth extraction","volume":"10","author":"Goiris FA","year":"2021","journal-title":"Research, Society and Development"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1034\/j.1600-0501.2001.120501.x","article-title":"Optimal implant stabilization in low density bone","volume":"12","author":"Martinez H","year":"2001","journal-title":"Clin Oral Impl Res"},{"issue":"12","key":"ref3","doi-asserted-by":"crossref","first-page":"1048","DOI":"10.1111\/j.1600-051X.2009.01482.x","article-title":"Alveolar bone dimensional changes of post-extraction sockets in humans: A systematic review","volume":"36","author":"Van Der Weijden F","year":"2009","journal-title":"J Clin Periodontol"},{"issue":"2","key":"ref4","first-page":"111","article-title":"Immediate versus early loading of 6.5 mm-long flapless-placed single implants: a 4-year after loading report of a split-mouth randomised controlled trial","volume":"5","author":"Cannizzaro G","year":"2012","journal-title":"Eur J Oral Implantol"},{"issue":"6","key":"ref5","doi-asserted-by":"crossref","first-page":"899","DOI":"10.4103\/ijdr.IJDR_259_19","article-title":"Qualitative and morphological evaluation of the mandibular bone using computed tomography","volume":"31","author":"Priyadarshini SR","year":"2020","journal-title":"Indian Journal of Dental Research"},{"issue":"4","key":"ref6","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1563\/1548-1336(2008)34[203:CIPIAP]2.0.CO;2","article-title":"Computer guided implant placement in a patient with severe atrophy","volume":"34","author":"Pe\u00f1arrocha M","year":"2008","journal-title":"Journal of Oral Implantology"},{"issue":"3","key":"ref7","first-page":"21","article-title":"An\u00e1lise de tens\u00f5es em implantes osseointegrados por elementos finitos: Varia\u00e7\u00e3o da ancoragem e di\u00e2metro dos implantes","volume":"7","author":"Moraes MCC de S e B","year":"2001","journal-title":"Revista Brasileira de Implantodontia"},{"key":"ref8","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.msec.2017.03.310","article-title":"Rehabilitation of the atrophic mandible with short implants in different positions: A finite elements study","volume":"80","author":"Peixoto HE","year":"2017","journal-title":"Materials Science and Engineering C"},{"issue":"10","key":"ref9","doi-asserted-by":"crossref","first-page":"1514","DOI":"10.1016\/j.jfma.2019.12.001","article-title":"Biomechanical effect of implant design on four implants supporting mandibular full-arch fixed dentures: In vitro test and finite element analysis","volume":"119","author":"Wu AYJ","year":"2020","journal-title":"Journal of the Formosan Medical Association"},{"year":"2016","series-title":"Analise das tens\u00f5es biomec\u00e2nicas no tecido \u00f3sseo periodontal pelo m\u00e9todo de elementos finitos","author":"Cerqueira M","key":"ref10"},{"key":"ref11","first-page":"200","article-title":"Finite element analysis: A boon to dentistry. Vol. 4, Journal of Oral Biology and Craniofacial Research","author":"Trivedi S","year":"2014","journal-title":"Elsevier B.V"},{"key":"ref12","doi-asserted-by":"crossref","DOI":"10.1590\/S1678-77572009000500029","article-title":"Biomechanical analysis of the stresses generated by different disoclusion patterns in an implant-supported mandibular complete denture","volume":"17","author":"Greco GD","year":"2009","journal-title":"J Appl Oral Sci."},{"issue":"2","key":"ref13","first-page":"204","article-title":"Treatment outcomes of patients with implant-supported fixed partial prostheses","volume":"13","author":"Wyatt CC","year":"1998","journal-title":"Int J Oral Maxillofac Implants"},{"year":"2009","series-title":"An\u00e1lise das tens\u00f5es em diferentes extens\u00f5es de pr\u00f3tese parcial fixa com conex\u00e3o dente-implante","author":"Castro JC de O","key":"ref14"},{"key":"ref15","first-page":"1","article-title":"Ef\ufb01cient and Reliable Finite Element Methods for Simulation of the Human Mandible","author":"Erdmann B","year":"2001","journal-title":"Zib-Report"},{"key":"ref16","series-title":"Avalia\u00e7\u00e3o da resist\u00eancia flexural e m\u00f3dulo de elasticidade de diferentes resinas compostas indiretas","volume":"19,","author":"Luiz Souto Borges A","year":"2012"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.msec.2017.05.071","article-title":"Three-dimensional finite element analysis of occlusal splint and implant connection on stress distribution in implant-supported fixed dental prosthesis and peri-implantal bone","volume":"80","author":"Marsico V dos S","year":"2017","journal-title":"Materials Science and Engineering C"},{"issue":"5","key":"ref18","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1016\/0022-3913(89)90285-0","article-title":"Basic biomechanics of dental implants in prosthetic dentistry","volume":"61","author":"Richter EJ","year":"1989","journal-title":"J Prosthet Dent"},{"issue":"5","key":"ref19","first-page":"722","article-title":"Haldun \/, Plik\u00e7iog \u02d8lu I\u00b7. Finite Element Stress Analysis of the Influence of Staggered Versus Straight Placement of Dental Implants","volume":"16","author":"Ak\u00e7a K","year":"2001","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"3","key":"ref20","doi-asserted-by":"crossref","first-page":"329","DOI":"10.21726\/rsbo.v8i3.1079","article-title":"Short implants in oral rehabilitation","volume":"8","author":"Chizolini EP","year":"2012","journal-title":"RSBO"},{"issue":"5","key":"ref21","doi-asserted-by":"crossref","DOI":"10.11607\/jomi.6548","article-title":"Rehabilitation of a Severely Resorbed Posterior Mandible with 4-mm Extra-Short Implants and Guided Bone Regeneration: Case Report with 3-year Follow-up","volume":"33","author":"Fabris V","year":"2018","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"S2","key":"ref22","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1111\/j.1600-0501.2006.01349.x","article-title":"Impact of implant length and diameter on survival rates","volume":"17","author":"Renouard F","year":"2006","journal-title":"Clin Oral Implants Res"},{"issue":"22","key":"ref23","first-page":"1","article-title":"Bone quality effect on short implants in the edentulous mandible: a finite element study","volume":"1","author":"Liu C","year":"2022","journal-title":"BMC Oral Health"},{"issue":"23","key":"ref24","first-page":"1","article-title":"Evaluation of two treatment concepts of four implants supporting fixed prosthesis in an atrophic maxilla: finite element analysis","volume":"1","author":"Li A","year":"2023","journal-title":"BMC Oral Health"},{"issue":"2","key":"ref25","first-page":"247","article-title":"Long-term Survival and Success of Oral Implants in the Treatment of Full and Partial Arches: A 7-year Prospective Study with the ITI Dental Implant System","volume":"19","author":"Romeo E","year":"2004","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"3","key":"ref26","first-page":"241","article-title":"Forces and moments on Branemark implants","volume":"4","author":"Rangert B","year":"1989","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"2","key":"ref27","doi-asserted-by":"crossref","first-page":"371","DOI":"10.4103\/ams.ams_147_19","article-title":"Immediately loaded bicortical implants inserted in fresh extraction and healed sites in patients with and without a history of periodontal disease","volume":"9","author":"Pa\u0142ka \u0141","year":"2019","journal-title":"Ann Maxillofac Surg"},{"issue":"1","key":"ref28","doi-asserted-by":"crossref","first-page":"109","DOI":"10.4103\/njms.njms_7_22","article-title":"Comparative evaluation of dental implants in posterior maxilla placed using unicortical and bicortical anchorage-A split-mouth prospective study","volume":"14","author":"Bhave S","year":"2023","journal-title":"Natl J Maxillofac Surg"},{"issue":"4","key":"ref29","first-page":"495","article-title":"Ten-year results for Br\u00e5nemark implants immediately loaded with fixed prostheses at implant placement","volume":"12","author":"Schnitman PA","year":"1997","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"4","key":"ref30","doi-asserted-by":"crossref","DOI":"10.1097\/SCS.0000000000005140","article-title":"Does the length of dental implants inserted in areas of inferior alveolar nerve lateralization interfere on mandibular resistance to fracture?","volume":"30","author":"Brackmann MS","year":"2019","journal-title":"Journal of Craniofacial Surgery"},{"issue":"1","key":"ref31","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1016\/j.jds.2021.07.020","article-title":"Biomechanical analysis of rigid and non-rigid connection with implant abutment designs for tooth-implant supported prosthesis: A finite element analysis","volume":"17","author":"Huang YC","year":"2022","journal-title":"J Dent Sci"},{"issue":"1","key":"ref32","first-page":"103","article-title":"Influence of bicortical or monocortical anchorage on maxillary implant stability: a 15-year retrospective study of Br\u00e5nemark System implants","volume":"15","author":"Ivanoff CJ","year":"2000","journal-title":"Int J Oral Maxillofac Implants"}],"container-title":["Brazilian Dental Journal"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_pdf&pid=S0103-64402024000100226&tlng=en","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,24]],"date-time":"2024-06-24T10:39:59Z","timestamp":1719225599000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S0103-64402024000100226&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024]]},"references-count":32,"alternative-id":["S0103-64402024000100226"],"URL":"https:\/\/doi.org\/10.1590\/0103-6440202405621","relation":{},"ISSN":["1806-4760","0103-6440"],"issn-type":[{"type":"electronic","value":"1806-4760"},{"type":"print","value":"0103-6440"}],"subject":[],"published":{"date-parts":[[2024]]},"article-number":"e24-5621"}}