{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T15:19:28Z","timestamp":1793891968035,"version":"4.8.0"},"reference-count":34,"publisher":"FapUNIFESP (SciELO)","license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"am","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Braz. Dent. J."],"abstract":"<jats:p>Abstract The amount of residual dentin thickness and tooth position in the dental arch is crucial to determine whether an intraradicular post should be used. This study aimed to compare stress distribution on the root dentin of an endodontically treated tooth rehabilitated with CAD\/CAM milled glass fiber posts (MP), cast metal posts (CMP), or prefabricated posts (PP) with or without ferrule support, using the finite element method. Materials and methods: A human upper central incisor was selected, scanned, and treated endodontically. The canal was then prepared for post-placement and scanned again for the fabrication of digital posts. The geometries of MP and CMP were based on the measurements made by digital scanning of the root canal. In contrast, the geometry of PP was determined by technical drawings provided by the manufacturer, taking into account the post-space preparation and the cement. Six digital models were established: MP1 with ferrule support, MP2 without ferrule support; CMP1 with ferrule support, CMP2 without ferrule support; PP1 with ferrule support, and PP2 without ferrule support. The simulation was performed using the finite element method. Results: Oblique forces were identified as more relevant to the metallic element compared to vertical forces. The presence of a ferrule was considered a protective factor for the remaining tooth structure. When the ferrule was absent, stresses were more evenly distributed in MP compared to CMP and PP. Posts with a higher modulus of elasticity were associated with higher and unequal stresses in the root dentin, which could predispose the tooth to fractures. Conclusions: As for the restoration set as a whole, it can be concluded that stress distribution on the root dentin was more evenly distributed on the milled post than on the other posts when a ferrule was absent, and the oblique forces were more detrimental to the tooth structure than vertical forces and that ferrule support was a protective factor for the remaining tooth structure. Clinical significance: The results of the study provide valuable information on how different types of intraradicular posts and the presence of a ferrule affect the stress distribution in dentin. In the absence of a ferrule, milled and customized computer-aided design\/computer-aided manufacturing (CAD\/CAM) glass fiber posts can exhibit better fracture resistance and adhesion strength than prefabricated fiberglass posts and metal posts.<\/jats:p>","DOI":"10.1590\/0103-644020246083","type":"journal-article","created":{"date-parts":[[2024,12,16]],"date-time":"2024-12-16T12:01:43Z","timestamp":1734350503000},"source":"Crossref","is-referenced-by-count":3,"title":["Comparative finite element analyses of stress exerted on the dentin by intraradicular posts"],"prefix":"10.1590","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3156-578X","authenticated-orcid":false,"given":"Erica Feleti Loren\u00e7on","family":"Dettogne","sequence":"first","affiliation":[{"name":"Pontifical Catholic University of Minas Gerais,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1753-110X","authenticated-orcid":false,"given":"K\u00eania Maria Pereira Soares de","family":"Toubes","sequence":"additional","affiliation":[{"name":"University of Uberaba,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1418-9994","authenticated-orcid":false,"given":"Luis Fernando dos Santos Alves","family":"Morgan","sequence":"additional","affiliation":[{"name":"Federal University of Minas Gerais,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4274-7340","authenticated-orcid":false,"given":"Paulo Isa\u00edas","family":"Seraidarian","sequence":"additional","affiliation":[{"name":"Pontifical Catholic University of Minas Gerais,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9155-082X","authenticated-orcid":false,"given":"Lucas Moreira","family":"Maia","sequence":"additional","affiliation":[{"name":"Ita\u00fana University,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4298-0540","authenticated-orcid":false,"given":"Frank Ferreira","family":"Silveira","sequence":"additional","affiliation":[{"name":"Pontifical Catholic University of Minas Gerais,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"530","published-online":{"date-parts":[[2024]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1016\/j.joen.2017.09.020","article-title":"\u201cFerrule Comes First. Post Is Second!\u201d Fake News and Alternative Facts? A Systematic Review","volume":"44","author":"Naumann M","year":"2018","journal-title":"J Endod"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"1473","DOI":"10.1111\/iej.13508","article-title":"European Society of Endodontology position statement: endodontic management of traumatized permanent teeth","volume":"54","author":"Krastl G","year":"2021","journal-title":"Int Endod J"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"1370","DOI":"10.1016\/j.joen.2017.02.017","article-title":"Long-term Success of Nonvital, Immature Permanent Incisors Treated With a Mineral Trioxide Aggregate Plug and Adhesive Restorations: A Case Series from a Private Endodontic Practice","volume":"43","author":"Ree MH","year":"2017","journal-title":"J Endod"},{"key":"ref4","doi-asserted-by":"crossref","first-page":"36","DOI":"10.5005\/jp-journals-10048-0064","article-title":"Impact of Mechanical Load of Three Post and Core Systems: CAD\/CAM-fabricated Glassfiber, Prefabricated Glassfiber Customized with Composite Resin, and Cast Metal Posts and Cores","volume":"5","author":"Pelegrine RA","year":"2021","journal-title":"Conservative Dentistry and Endodontic Journal"},{"key":"ref5","first-page":"326","article-title":"Influence of different posts and cores on marginal adaptation, fracture resistance, and fracture mode of composite resin crowns on human mandibular premolars","volume":"34","author":"Stricker EJ","year":"2006","journal-title":"An in vitro study. J Dent"},{"key":"ref6","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.jmbbm.2018.03.035","article-title":"Mechanical properties and superficial characterization of a milled CAD-CAM glass fiber post","volume":"82","author":"Ruschel GH","year":"2018","journal-title":"J Mech Behav Biomed Mater"},{"key":"ref7","first-page":"s519","article-title":"Finite element analysis to study the effects of using CAD\/CAM glass-fiber post system in a severely damaged anterior tooth","volume":"26","author":"Chen A","year":"2015","journal-title":"Biomed Mater Eng"},{"key":"ref8","doi-asserted-by":"crossref","first-page":"17","DOI":"10.2147\/CCIDE.S237442","article-title":"CAD\/CAM customized glass fiber post and core with digital intraoral impression: A case report","volume":"12","author":"Libonati A","year":"2020","journal-title":"Clin Cosmet Investig Dent"},{"key":"ref9","doi-asserted-by":"crossref","first-page":"114","DOI":"10.4012\/dmj.2017-394","article-title":"Fracture behaviors of maxillary central incisors with flared root canals restored with CAD\/CAM integrated glass fiber postand-core","volume":"38","author":"Pang J","year":"2019","journal-title":"Dent Mater J"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/0022-3913(90)90070-S","article-title":"Ferrule design and fracture resistance of endodontically treated teeth","volume":"63","author":"Sorensen JA","year":"1990","journal-title":"J Prosthet Dent"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"1280","DOI":"10.1016\/j.dental.2013.10.003","article-title":"The influence of substance loss and ferrule height on the fracture resistance of endodontically treated premolars","volume":"29","author":"Samran A","year":"2013","journal-title":"An in vitro study. Dent Mater"},{"key":"ref12","first-page":"19:264","article-title":"Comparative evaluation of the effect of different crown ferrule designs on the fracture resistance of endodontically treated mandibular premolars restored with fiber posts, composite cores, and crowns: An ex-vivo study","author":"Dua N","year":"2016","journal-title":"J Conserv Dent"},{"key":"ref13","doi-asserted-by":"crossref","first-page":"436","DOI":"10.3390\/ma15020436","article-title":"Fracture Resistance in Non-Vital Teeth: Absence of Interproximal Ferrule and Influence of Preparation Depth in CAD\/CAM Endocrown Overlays&mdash;An In Vitro Study","volume":"15","author":"Barallat L","year":"2022","journal-title":"Materials"},{"key":"ref14","doi-asserted-by":"crossref","DOI":"10.2341\/18-241-L","article-title":"Effect of ferrule thickness on fracture resistance of teeth restored with a glass fiber post or cast post","volume":"44","author":"Fontana PE","year":"2019","journal-title":"Oper Dent"},{"issue":"1","key":"ref15","article-title":"Three-Dimensional Finite Element Study of Endodontically Treated Maxillary Central Incisors Restored Using Different Post and Crown Materials","volume":"15","author":"Kharboutly NA","year":"2023","journal-title":"Cureus"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1111\/j.1532-849X.2010.00669.x","article-title":"Three-dimensional FEA of Effects of Two Dowel-and-Core Approaches and Effects of Canal Flaring on Stress Distribution in Endodontically Treated Teeth","volume":"20","author":"Mezzomo LA","year":"2011","journal-title":"J Prosthodont"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1111\/j.1365-2842.2006.01538.x","article-title":"Stress distribution in a post-restored tooth using the three-dimensional finite element method","volume":"33","author":"Boschian Pest L","year":"2006","journal-title":"J Oral Rehabil"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"524","DOI":"10.2341\/22-083-L","article-title":"Evaluation of bond strength andfracture load of teeth with flared root canals restored with prefabricated, anatomical, and computer-aided design and computer-aided manufacturing fiber posts","volume":"48","author":"Taques LV","year":"2023","journal-title":"Oper Dent"},{"issue":"47","key":"ref19","doi-asserted-by":"crossref","first-page":"449","DOI":"10.2341\/21-094-L","article-title":"Retention of Manually or CAD\/CAM-customized Fiberglass Posts Luted to Enlarged Root Canals with Different Resin Cements","volume":"1","author":"Bellan MC","year":"2022","journal-title":"Oper Dent"},{"issue":"24","key":"ref20","article-title":"Are CAD-CAM milled glass fiber posts better than prefabricated or custom glass fiber posts for endodontically treated teeth? A systematic review with meta-analysis","volume":"8","author":"Campos GB","year":"2024","journal-title":"J Prosthet Dent"},{"issue":"2","key":"ref21","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/j.prosdent.2022.01.007","article-title":"CAD-CAM glass fiber compared with conventional prefabricated glass fiber posts: A systematic review","volume":"132","author":"Costa TS","year":"2024","journal-title":"J Prosthet Dent"},{"key":"ref22","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/j.prosdent.2019.01.004","article-title":"Influence of the ferrule effect on the failure of fiber-reinforced composite post-and-core restorations: A systematic review and meta-analysis","volume":"123","author":"Batista VES","year":"2020","journal-title":"J Prosthet Dent"},{"key":"ref23","first-page":"146","article-title":"Evaluation of the Effect of Different Ferrule Designs on Fracture Resistance of Maxillary Incisors Restored with Bonded Posts and Cores","volume":"7","author":"Mahdavi Izadi Z","year":"2010","journal-title":"J Dent"},{"key":"ref24","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.jdent.2008.10.007","article-title":"Long-term survival of endodontically treated, maxillary anterior teeth restored with either tapered or parallel-sided glass-fiber posts and full-ceramic crown coverage","volume":"37","author":"Signore A","year":"2009","journal-title":"J Dent"},{"key":"ref25","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1111\/jopr.13090","article-title":"Effect of Ferrule Location with Varying Heights on Fracture Resistance and Failure Mode of Restored Endodontically Treated Maxillary Incisors","volume":"28","author":"Santos Pantale\u00f3n D","year":"2019","journal-title":"J Prosthodont"},{"key":"ref26","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2021.104433","article-title":"The influence of customization of glass fiber posts on fracture strength and failure pattern: A systematic review and meta-analysis of preclinical ex-vivo studies","volume":"118","author":"Silva CF","year":"2021","journal-title":"J Mech Behav Biomed Mater"},{"key":"ref27","doi-asserted-by":"crossref","first-page":"349","DOI":"10.2147\/CCIDE.S219712","article-title":"Evaluating fracture resistance and failure modes of root filled teeth restored with CAD\/CAM-fabricated post and core","volume":"11","author":"Alkhatri R","year":"2019","journal-title":"Clin Cosmet Investig Dent"},{"issue":"42","key":"ref28","doi-asserted-by":"crossref","first-page":"92","DOI":"10.4012\/dmj.2022-114","article-title":"Fracture resistance of weakened roots restored with relined or milled CAD-CAM glass fiber posts","volume":"31","author":"Maia BDGO","year":"2023","journal-title":"Dent Mater J"},{"key":"ref29","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1016\/S0022-3913(10)60071-6","article-title":"Use of a CAD\/CAM-fabricated glass fiber post and core to restore fractured anterior teeth: A clinical report","volume":"103","author":"Liu P","year":"2010","journal-title":"J Prosthet Dent"},{"key":"ref30","doi-asserted-by":"crossref","first-page":"671","DOI":"10.4012\/dmj.28.671","article-title":"Finite element analysis of weakened roots restored with composite resin and posts","volume":"28","author":"Coelho CSM","year":"2009","journal-title":"Dent Mater J"},{"key":"ref31","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/S0109-5641(03)00065-4","article-title":"Flexural properties of fiber reinforced root canal posts","volume":"20","author":"Lassila LVJ","year":"2004","journal-title":"Dent Mater"},{"key":"ref32","doi-asserted-by":"crossref","first-page":"2375","DOI":"10.1016\/j.jbiomech.2004.10.009","article-title":"Finite element analysis of a new customized composite post system for endodontically treated teeth","volume":"38","author":"Genovese K","year":"2005","journal-title":"J Biomech"},{"key":"ref33","doi-asserted-by":"crossref","first-page":"3224","DOI":"10.1016\/j.actbio.2009.04.008","article-title":"Mechanical properties of glass fiber-reinforced endodontic posts","volume":"5","author":"Cheleux N","year":"2009","journal-title":"Acta Biomater"},{"key":"ref34","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/S0109-5641(03)00065-4","article-title":"Flexural properties of fiber reinforced root canal posts","volume":"20","author":"Lassila LVJ","year":"2004","journal-title":"Dent Mater"}],"container-title":["Brazilian Dental Journal"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_pdf&pid=S0103-64402024000100270&tlng=en","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,16]],"date-time":"2024-12-16T12:01:54Z","timestamp":1734350514000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S0103-64402024000100270&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024]]},"references-count":34,"alternative-id":["S0103-64402024000100270"],"URL":"https:\/\/doi.org\/10.1590\/0103-644020246083","relation":{},"ISSN":["1806-4760","0103-6440"],"issn-type":[{"value":"1806-4760","type":"electronic"},{"value":"0103-6440","type":"print"}],"subject":[],"published":{"date-parts":[[2024]]},"article-number":"e24-6083"}}