{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T15:04:10Z","timestamp":1753887850464,"version":"3.41.2"},"reference-count":8,"publisher":"FapUNIFESP (SciELO)","issue":"4","license":[{"start":{"date-parts":[[2022,1,1]],"date-time":"2022-01-01T00:00:00Z","timestamp":1640995200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2022,1,1]],"date-time":"2022-01-01T00:00:00Z","timestamp":1640995200000},"content-version":"am","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2022,1,1]],"date-time":"2022-01-01T00:00:00Z","timestamp":1640995200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta ortop. bras."],"abstract":"<jats:p>ABSTRACT  Introduction:  Osteonecrosis of the femoral head (ONFH) is a pathology that can be treated with many approaches by the hip surgeon. Advanced decompression is a technique that aims to prevent the collapse of the femoral head and the arthrosis process of the joint, a technique already widespread and used by hip surgeons. In this study, we performed the technique with a new retractable blade and a new bone substitute as graft for the femoral head.  Objective:  To evaluate the technique with new instruments (EasyCore Hip\u00ae) and a calcium phosphate bone substitute (Graftys\u00ae HBS).  Methods:  Patients with osteonecrosis of the femoral head without major degenerative changes, such as femoral head collapse, were selected. Femoral head decompression was performed using the EasyCore Hip\u00ae retractable blade along with the calcium phosphate bone substitute as graft (Graftys\u00ae HBS).  Results:  The instruments proved to be reliable and reproducible, and the bone substitute presented good mechanical resistance, maintaining its temperature during the surgery. The disposable retractable blade presents variation in size and angle, which is an advantage in the removal of necrotic bone. However, we must take some precautions in order to achieve a better result.  Conclusion:  using EasyCore Hip\u00ae instruments and a calcium phosphate bone substitute (Graftys\u00ae HBS) is safe; however, some precautions must be taken during the use of the technique. Level of Evidence IV, Case Series.<\/jats:p>","DOI":"10.1590\/1413-785220223004e250481","type":"journal-article","created":{"date-parts":[[2022,8,29]],"date-time":"2022-08-29T09:11:26Z","timestamp":1661764286000},"source":"Crossref","is-referenced-by-count":1,"title":["FEMORAL HEAD DECOMPRESSION AND GRAFT: TECHNIQUE WITH NEW INSTRUMENTS"],"prefix":"10.1590","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2532-2685","authenticated-orcid":false,"given":"HELDER DE SOUZA","family":"MIYAHARA","sequence":"first","affiliation":[{"name":"Universidade de S\u00e3o Paulo,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0780-6811","authenticated-orcid":false,"given":"BRUNO ALVES","family":"RUDELLI","sequence":"additional","affiliation":[{"name":"Universidade de S\u00e3o Paulo,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6503-5963","authenticated-orcid":false,"given":"LUCAS VERISSIMO","family":"RANZONI","sequence":"additional","affiliation":[{"name":"Universidade de S\u00e3o Paulo,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9866-1960","authenticated-orcid":false,"given":"LEANDRO","family":"EJNISMAN","sequence":"additional","affiliation":[{"name":"Universidade de S\u00e3o Paulo,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3528-9249","authenticated-orcid":false,"given":"JOS\u00c9 RICARDO NEGREIROS","family":"VICENTE","sequence":"additional","affiliation":[{"name":"Universidade de S\u00e3o Paulo,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2005-0553","authenticated-orcid":false,"given":"HENRIQUE MELO DE CAMPOS","family":"GURGEL","sequence":"additional","affiliation":[{"name":"Universidade de S\u00e3o Paulo,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"530","published-online":{"date-parts":[[2022]]},"reference":[{"issue":"18","key":"ref1","doi-asserted-by":"crossref","first-page":"441","DOI":"10.21037\/atm.2019.08.86","article-title":"Outcome after a new porous tantalum rod implantation for treatment of early-stage femoral head osteonecrosis","volume":"7","author":"Huang W","year":"2019","journal-title":"Ann Transl Med"},{"issue":"7","key":"ref2","doi-asserted-by":"crossref","first-page":"1491","DOI":"10.1007\/s00264-018-3892-0","article-title":"Hip osteonecroses treated with calcium sulfate-calcium phosphate bone graft substitute have different results according to the cause of osteonecrosis: alcohol abuse or corticosteroid-induced","volume":"42","author":"Sionek A","year":"2018","journal-title":"Int Orthop"},{"issue":"1","key":"ref3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1093\/rb\/rbz048","article-title":"Application of biomaterials for the repair and treatment of osteonecrosis of the femoral head","volume":"7","author":"Zhao D","year":"2020","journal-title":"Regen Biomater"},{"issue":"7","key":"ref4","doi-asserted-by":"crossref","first-page":"1723","DOI":"10.1007\/s00264-018-3917-8","article-title":"Early-stage osteonecrosis of the femoral head: where are we and where are we going in year 2018?","volume":"42","author":"Larson E","year":"2018","journal-title":"Int Orthop"},{"issue":"5","key":"ref5","first-page":"537","article-title":"What is the role of core decompression in the early stages of osteonecrosis of the femoral head? Evaluation of the surgical result by functional score and radiological follow-up","volume":"53","author":"Miyahara HS","year":"2018","journal-title":"Rev Bras Ortop"},{"issue":"1","key":"ref6","doi-asserted-by":"crossref","first-page":"72","DOI":"10.3109\/17453674.2015.1077418","article-title":"The role of \"cell therapy\" in osteonecrosis of the femoral head. A systematic review of the literature and meta-analysis of 7 studies","volume":"87","author":"Papakostidis C","year":"2016","journal-title":"Acta Orthop"},{"issue":"4","key":"ref7","doi-asserted-by":"crossref","first-page":"1308","DOI":"10.1002\/term.2056","article-title":"Two-year follow-up after advanced core decompression","volume":"11","author":"Classen T","year":"2017","journal-title":"J Tissue Eng Regen Med"},{"issue":"3","key":"ref8","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1007\/s00264-018-4013-9","article-title":"Long-term outcomes of Phemister bone grafting for patients with non-traumatic osteonecrosis of the femoral head","volume":"43","author":"Wu CT","year":"2019","journal-title":"Int Orthop"}],"container-title":["Acta Ortop\u00e9dica Brasileira"],"original-title":["DESCOMPRESS\u00c3O DA CABE\u00c7A FEMORAL E ENXERTIA: T\u00c9CNICA COM NOVO INSTRUMENTAL"],"link":[{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_pdf&pid=S1413-78522022002400202&tlng=en","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,29]],"date-time":"2022-08-29T09:11:33Z","timestamp":1661764293000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S1413-78522022002400202&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022]]},"references-count":8,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2022]]}},"alternative-id":["S1413-78522022002400202"],"URL":"https:\/\/doi.org\/10.1590\/1413-785220223004e250481","relation":{},"ISSN":["1809-4406","1413-7852"],"issn-type":[{"type":"electronic","value":"1809-4406"},{"type":"print","value":"1413-7852"}],"subject":[],"published":{"date-parts":[[2022]]},"article-number":"e250481"}}