{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T15:06:07Z","timestamp":1753887967076,"version":"3.41.2"},"reference-count":11,"publisher":"FapUNIFESP (SciELO)","issue":"5","license":[{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"am","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta ortop. bras."],"abstract":"<jats:p>ABSTRACT Objective: To evaluate the effectiveness of the dorsal fixation technique with a cannulated compression screw (CCS) for transverse scaphoid neck fractures. Methods: A case series study was carried out with patients treated with a CSS between April 2014 and May 2021. The main outcome was the healing of the fracture, verified by radiographic evaluation that used images of the wrist in anteroposterior, lateral, radial deviation, ulnar deviation and oblique views, obtained in the postoperative period. Results: Fifty-two patients aged between 15 and 65 years were analyzed, of which 43 (83%) were male. Of the 52 patients, 19 (36.53%) had a right-hand injury and 33 (63.46%) had a left-hand injury. Results were excellent in 47 patients (90.38%); good in 4 patients (7.69%), with reduced mobility compared to contralateral and poor in 1 patient (1.92%), with failure of consolidation and breakage of the synthesis material. In 51 cases (99%) there was bone consolidation at the end of six months. Conclusion: Osteosynthesis with a cannulated compression screw is a safe, effective and promising method for the treatment of scaphoid neck fractures. Level of Evidence IV, Case Series.<\/jats:p>","DOI":"10.1590\/1413-785220233105e264116","type":"journal-article","created":{"date-parts":[[2023,10,23]],"date-time":"2023-10-23T11:18:53Z","timestamp":1698059933000},"source":"Crossref","is-referenced-by-count":1,"title":["OSTEOSYNTHESIS OF A SCAPHOID NECK FRACTURE WITH A CANNULATED COMPRESSION SCREW: EVALUATION OF 52 PATIENTS"],"prefix":"10.1590","volume":"31","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2579-1756","authenticated-orcid":false,"given":"LUCAS BERNARDO CARVALHO DE","family":"ALMEIDA","sequence":"first","affiliation":[{"name":"Rede D\u2019Or,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5044-7332","authenticated-orcid":false,"given":"VICTOR MARTINS","family":"MANFREDI","sequence":"additional","affiliation":[{"name":"Rede D\u2019Or,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4789-7519","authenticated-orcid":false,"given":"IGOR ARTHUR PARRON","family":"COSTA","sequence":"additional","affiliation":[{"name":"Rede D\u2019Or,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7355-5291","authenticated-orcid":false,"given":"F\u00c1BIO SANO","family":"IMOTO","sequence":"additional","affiliation":[{"name":"Rede D\u2019Or,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6735-1401","authenticated-orcid":false,"given":"EIFFEL TSUIOSHI","family":"DOBASHI","sequence":"additional","affiliation":[{"name":"Rede D\u2019Or,  Brazil; Universidade Federal de S\u00e3o Paulo,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5708-5450","authenticated-orcid":false,"given":"THIAGO BERNARDO CARVALHO DE","family":"ALMEIDA","sequence":"additional","affiliation":[{"name":"Rede D\u2019Or,  Brazil; Rede D\u2019Or,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6891-5395","authenticated-orcid":false,"given":"LUCIANO MILLER REIS","family":"RODRIGUES","sequence":"additional","affiliation":[{"name":"Universidade Federal de S\u00e3o Paulo,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"530","published-online":{"date-parts":[[2023]]},"reference":[{"series-title":"Scaphoid wrist fracture","author":"Hayat Z","key":"ref1"},{"issue":"6","key":"ref2","doi-asserted-by":"crossref","first-page":"988","DOI":"10.1016\/j.jhsa.2008.04.026","article-title":"Treatment of scaphoid fractures and nonunions","volume":"33","author":"Kawamura K","year":"2008","journal-title":"J Hand Surg Am"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"105480","DOI":"10.1016\/j.clinbiomech.2021.105480","article-title":"Use of biomaterials in scaphoid fracture fixation, a systematic review","volume":"89","author":"Feeley A","year":"2021","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"A","key":"ref4","doi-asserted-by":"crossref","first-page":"21","DOI":"10.2106\/00004623-200200002-00003","article-title":"Percutaneous internal fixation of scaphoid fractures via an arthroscopically assisted dorsal approach","volume":"84","author":"Slade 3rd JF","year":"2002","journal-title":"J Bone Joint Surg Am"},{"issue":"6","key":"ref5","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1016\/j.jhsa.2007.04.003","article-title":"Complications in dorsal percutaneous cannulated screw fixation of nondisplaced scaphoid waist fractures","volume":"32","author":"Bushnell BD","year":"2007","journal-title":"J Hand Surg Am"},{"issue":"7","key":"ref6","first-page":"255","article-title":"Correla\u00e7\u00e3o radiol\u00f3gica nas pseudartroses do escaf\u00f3ide carpal","volume":"36","author":"Chakkour I","year":"2001","journal-title":"Rev Bras Ortop"},{"issue":"1","key":"ref7","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1097\/BTH.0000000000000278","article-title":"A mini-open, dorsal approach for scaphoid fracture fixation with a ligament sparing arthrotomy","volume":"24","author":"Dodds SD","year":"2020","journal-title":"Tech Hand Up Extrem Surg"},{"issue":"7","key":"ref8","first-page":"363","article-title":"Fixa\u00e7\u00e3o percut\u00e2nea das fraturas de ter\u00e7o m\u00e9dio do escaf\u00f3ide","volume":"39","author":"Folberg CR","year":"2004","journal-title":"Rev Bras Ortop"},{"issue":"2","key":"ref9","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/S0363-5023(84)80148-3","article-title":"The molded polythene splint for mallet finger deformities","volume":"9","author":"Crawford GP","year":"1984","journal-title":"J Hand Surg Am"},{"issue":"3","key":"ref10","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/j.jhsa.2007.12.006","article-title":"Percutaneous fixation of the scaphoid through a dorsal approach an anatomic study","volume":"33","author":"Adamany DC","year":"2008","journal-title":"J Hand Surg Am"},{"issue":"5","key":"ref11","doi-asserted-by":"crossref","first-page":"339","DOI":"10.3944\/AOTT.2012.2816","article-title":"Comparison of dorsal and volar percutaneous screw fixation methods in acute Type B scaphoid fractures","volume":"46","author":"G\u00fcrb\u00fcz Y","year":"2012","journal-title":"Acta Orthop Traumatol Turc"}],"container-title":["Acta Ortop\u00e9dica Brasileira"],"original-title":["OSTEOSS\u00cdNTESE DE FRATURA NO COLO DO ESCAFOIDE COM PARAFUSO CANULADO DE COMPRESS\u00c3O: AVALIA\u00c7\u00c3O DE 52 PACIENTES"],"link":[{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_pdf&pid=S1413-78522023000800201&tlng=en","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,23]],"date-time":"2023-10-23T11:19:00Z","timestamp":1698059940000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S1413-78522023000800201&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023]]},"references-count":11,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2023]]}},"alternative-id":["S1413-78522023000800201"],"URL":"https:\/\/doi.org\/10.1590\/1413-785220233105e264116","relation":{},"ISSN":["1809-4406","1413-7852"],"issn-type":[{"type":"electronic","value":"1809-4406"},{"type":"print","value":"1413-7852"}],"subject":[],"published":{"date-parts":[[2023]]},"article-number":"e264116"}}