{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T22:52:48Z","timestamp":1772232768022,"version":"3.50.1"},"reference-count":25,"publisher":"FapUNIFESP (SciELO)","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"am","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Rev. Latino-Am. Enfermagem"],"abstract":"<jats:p>Objective: to identify the main factors related to complications of the invasive blood pressure system.  Method: prospective study conducted with patients over 18 years of age admitted to intensive care, using a device for measuring invasive blood pressure. Participants were monitored during the catheter dwell-time and sociodemographic, clinical and device data were collected. The outcome analyzed was removal due to non-indication of use or due to complications. Student\u2019s t-test, Mann-Whitney U test, chi-square test and Fisher\u2019s exact test were used for the analyses.  Results: 50 participants were included and monitored, and most devices were installed in the radial artery (86%), with a 20-gauge catheter (50%), all with a flexible catheter. Each patient remained, on average, 4.36 days (SD: 3.504) with the device. Regarding the outcomes, 60.0% of the devices were removed due to non-indication of use and 40.0% due to complications. Phlebitis was the most prevalent complication, and pressure in the bag was the factor associated with catheter removal before the time of indication (p=0.046).  Conclusion: the main complications associated with this device were obstruction and phlebitis, while pressure in the bag was the factor related to catheter removal before indication.<\/jats:p>","DOI":"10.1590\/1518-8345.7097.4443","type":"journal-article","created":{"date-parts":[[2025,1,31]],"date-time":"2025-01-31T05:44:39Z","timestamp":1738302279000},"source":"Crossref","is-referenced-by-count":0,"title":["Factors related to complications of the invasive blood pressure system among adult and elderly patients: a prospective study"],"prefix":"10.1590","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-6811-4461","authenticated-orcid":false,"given":"Willian Marques de","family":"Souza","sequence":"first","affiliation":[{"name":"Centro Universit\u00e1rio Central Paulista,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-4014-2091","authenticated-orcid":false,"given":"Victor Hugo Baldan","family":"Cypriano","sequence":"additional","affiliation":[{"name":"Centro Universit\u00e1rio Central Paulista,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3417-5581","authenticated-orcid":false,"given":"Ros\u00e2ngela Aparecida de","family":"Sousa","sequence":"additional","affiliation":[{"name":"Universidade Federal de S\u00e3o Carlos,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5683-7040","authenticated-orcid":false,"given":"Rafael Luis Bressani","family":"Lino","sequence":"additional","affiliation":[{"name":"Universidade de S\u00e3o Paulo,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2942-5515","authenticated-orcid":false,"given":"Ana Luiza","family":"Mroczinski","sequence":"additional","affiliation":[{"name":"Centro Universit\u00e1rio Central Paulista,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0516-5213","authenticated-orcid":false,"given":"Danielle Cristina","family":"Garbuio","sequence":"additional","affiliation":[{"name":"Centro Universit\u00e1rio Central Paulista,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"530","published-online":{"date-parts":[[2025]]},"reference":[{"key":"ref1","series-title":"Treasure Island","volume-title":"Arterial Lines [Internet]","author":"Pierre L.","year":"2022"},{"issue":"3","key":"ref2","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1186\/cc1489","article-title":"Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine","volume":"6","author":"Scheer B.","year":"2002","journal-title":"Crit Care"},{"issue":"1","key":"ref3","article-title":"How to measure blood pressure using an arterial catheter: a systematic 5-step approach","volume":"24","author":"Saugel B.","year":"2020","journal-title":"Crit Care"},{"key":"ref4","series-title":"Treasure Island","volume-title":"Artery Cannulation [Internet]","author":"Hager H. H.","year":"2023"},{"issue":"5","key":"ref5","doi-asserted-by":"crossref","first-page":"1540","DOI":"10.1213\/ANE.0000000000004370","article-title":"Arterial catheters for early detection and treatment of hypotension during major noncardiac surgery: a randomized trial","volume":"131","author":"Naylor A. J.","year":"2020","journal-title":"Anesth Analg"},{"issue":"1","key":"ref6","article-title":"Comparative Evaluation of Three Different Techniques of Radial Artery Cannulation: A Prospective Randomised Study","volume":"16","author":"Singla D.","year":"2024","journal-title":"Cureus"},{"issue":"1","key":"ref7","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-022-12975-y","article-title":"Agreements between mean arterial pressure from radial and femoral artery measurements in refractory shock patients","volume":"12","author":"Wisanusattra H.","year":"2022","journal-title":"Sci Rep"},{"key":"ref8","doi-asserted-by":"crossref","DOI":"10.3389\/fmed.2022.1019752","article-title":"Arterial site selection for measurement of mean arterial pressure in septic shock patients on high-dose norepinephrine","volume":"9","author":"Bhaskar B.","year":"2022","journal-title":"Front Med"},{"issue":"11","key":"ref9","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1016\/j.jhsa.2019.06.018","article-title":"Complications of transradial catheterization and cannulation","volume":"44","author":"Hadad M. H.","year":"2019","journal-title":"J Hand Surg Am"},{"issue":"1","key":"ref10","doi-asserted-by":"crossref","DOI":"10.1186\/s40560-024-00719-1","article-title":"Risk factors for arterial catheter failure and complications during critical care hospitalisation: a secondary analysis of a multisite, randomised trial","volume":"12","author":"Schults J. A.","year":"2024","journal-title":"J Intensive Care"},{"key":"ref11","series-title":"Resolu\u00e7\u00e3o n.703\/2022. Atualiza a norma para a execu\u00e7\u00e3o, pelo Enfermeiro, da pun\u00e7\u00e3o arterial para gasometria e\/ou instala\u00e7\u00e3o de cateter intra-arterial para monitoriza\u00e7\u00e3o da press\u00e3o arterial invasiva (PAI) [Internet]","year":"2022"},{"issue":"5","key":"ref12","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1111\/nicc.12610","article-title":"The knowledge and practice of maintaining the patency of arterial catheters","volume":"27","author":"Xiao Y.","year":"2022","journal-title":"Nurs Crit Care"},{"issue":"7624","key":"ref13","doi-asserted-by":"crossref","first-page":"806","DOI":"10.1136\/bmj.39335.541782.AD","article-title":"Strengthening the reporting of observational studies in epidemiology (STROBE) statement: guidelines for reporting observational studies","volume":"335","author":"Elm E.","year":"2007","journal-title":"BMJ"},{"issue":"1S Suppl 1","key":"ref14","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/NAN.0000000000000396","article-title":"Infusion Therapy Standards of Practice, 8th Edition","volume":"44","author":"Gorski L. A.","year":"2021","journal-title":"J Infus Nurs"},{"issue":"1","key":"ref15","first-page":"3","article-title":"Calculating and reporting effect sizes on scientific papers (1): p < 0.05 limitations in the analysis of mean differences of two groups [Internet]","volume":"1","author":"Esp\u00edrito Santo H.","year":"2015","journal-title":"Port J Behav Soc Res"},{"key":"ref16","series-title":"Statistical power analysis for the behavioral sciences","first-page":"567","author":"Cohen J.","year":"1988","edition":"2nd"},{"issue":"5","key":"ref17","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1097\/EJA.0000000000001443","article-title":"Mode of blood pressure monitoring and morbidity after noncardiac surgery: A prospective multicentre observational cohort study","volume":"38","author":"Abbott T. E. F.","year":"2021","journal-title":"Eur J Anaesthesiol"},{"key":"ref18","series-title":"Edwards clinical education: Quick guide to cardiopulmonary care","first-page":"185","author":"McGee W. T.","year":"2018","edition":"4th"},{"issue":"3","key":"ref19","first-page":"380","article-title":"Thermodiluition cardiac output measurements","volume":"31","author":"Pereira J\u00fanior G. A.","year":"1998","journal-title":"Medicina (Ribeir\u00e3o Preto)"},{"issue":"5","key":"ref20","article-title":"Heparin versus normal saline for patency of arterial lines","volume":"2024","author":"Robertson-Malt S.","year":"2014","journal-title":"Cochrane Database Syst Rev"},{"issue":"1","key":"ref21","first-page":"51","article-title":"Comparison of normal saline and heparinized solutions for the maintenance of arterial catheter pressure waves: a randomized pilot study","volume":"17","author":"Ishii Y.","year":"2021","journal-title":"Signa Vitae"},{"issue":"3","key":"ref22","doi-asserted-by":"crossref","first-page":"358","DOI":"10.5811\/westjem.2022.1.53211","article-title":"Discrepancy Between Invasive and Noninvasive Blood Pressure Measurements in Patients with Sepsis by Vasopressor Status","volume":"23","author":"Tran Q. K.","year":"2022","journal-title":"West J Emerg Med"},{"key":"ref23","doi-asserted-by":"crossref","DOI":"10.1590\/1518-8345.2377.3002","article-title":"Phlebitis and infiltration: vascular trauma associated with the peripheral venous catheter","volume":"26","author":"Braga L. M.","year":"2018","journal-title":"Rev. Latino-Am. Enfermagem"},{"issue":"1","key":"ref24","doi-asserted-by":"crossref","DOI":"10.1186\/s13613-022-01009-5","article-title":"Risk factors for peripheral intravascular catheter-related phlebitis in critically ill patients: analysis of 3429 catheters from 23 Japanese intensive care units","volume":"12","author":"Yasuda H.","year":"2022","journal-title":"Ann Intensive Care"},{"key":"ref25","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCINTERVENTIONS.119.007386","article-title":"Transradial Artery Access Complications","volume":"12","author":"Sandoval Y.","year":"2019","journal-title":"Circ Cardiovasc Interv"}],"container-title":["Revista Latino-Americana de Enfermagem"],"original-title":["Fatores relacionados \u00e0s complica\u00e7\u00f5es no sistema de press\u00e3o arterial invasiva em pacientes adultos e idosos: estudo prospectivo"],"link":[{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_pdf&pid=S0104-11692025000100306&tlng=en","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,31]],"date-time":"2025-01-31T05:44:50Z","timestamp":1738302290000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S0104-11692025000100306&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025]]},"references-count":25,"alternative-id":["S0104-11692025000100306"],"URL":"https:\/\/doi.org\/10.1590\/1518-8345.7097.4443","relation":{"is-translation-of":[{"id-type":"doi","id":"10.1590\/1518-8345.7097.4442","asserted-by":"subject"},{"id-type":"doi","id":"10.1590\/1518-8345.7097.4444","asserted-by":"subject"},{"id-type":"doi","id":"10.1590\/1518-8345.7097.4444","asserted-by":"object"},{"id-type":"doi","id":"10.1590\/1518-8345.7097.4442","asserted-by":"object"}]},"ISSN":["1518-8345"],"issn-type":[{"value":"1518-8345","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025]]},"article-number":"e4443"}}