{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T23:23:35Z","timestamp":1783985015999,"version":"3.55.0"},"reference-count":18,"publisher":"FapUNIFESP (SciELO)","issue":"6","license":[{"start":{"date-parts":[[2022,6,1]],"date-time":"2022-06-01T00:00:00Z","timestamp":1654041600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2022,6,1]],"date-time":"2022-06-01T00:00:00Z","timestamp":1654041600000},"content-version":"am","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2022,6,1]],"date-time":"2022-06-01T00:00:00Z","timestamp":1654041600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Rev. Assoc. Med. Bras."],"DOI":"10.1590\/1806-9282.20210729","type":"journal-article","created":{"date-parts":[[2022,6,29]],"date-time":"2022-06-29T01:50:42Z","timestamp":1656467442000},"page":"754-758","source":"Crossref","is-referenced-by-count":3,"title":["Cadaveric study of anatomical measurement of isthmus parameters of lumbar spine to guide cortical bone screw placement"],"prefix":"10.1590","volume":"68","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5889-0179","authenticated-orcid":false,"given":"Paerhati","family":"Rexiti","sequence":"first","affiliation":[{"name":"The First Affiliated Hospital of Xinjiang Medical University,  China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3150-4378","authenticated-orcid":false,"given":"Dilimulati","family":"Aikeremu","sequence":"additional","affiliation":[{"name":"People\u2019s Hospital of Xinjiang Uygur Autonomous Region,  China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8013-5962","authenticated-orcid":false,"given":"Shuiquan","family":"Wang","sequence":"additional","affiliation":[{"name":"Xinjiang Medical University, College of Basic Medicine,  China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6131-6488","authenticated-orcid":false,"given":"Nueraihemaiti","family":"Abuduwali","sequence":"additional","affiliation":[{"name":"The First Affiliated Hospital of Xinjiang Medical University,  China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0181-9806","authenticated-orcid":false,"given":"Alafate","family":"Kahaer","sequence":"additional","affiliation":[{"name":"The First Affiliated Hospital of Xinjiang Medical University,  China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6644-3221","authenticated-orcid":false,"given":"Weibin","family":"Sheng","sequence":"additional","affiliation":[{"name":"The First Affiliated Hospital of Xinjiang Medical University,  China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"530","published-online":{"date-parts":[[2022,6]]},"reference":[{"issue":"5","key":"ref1","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1016\/j.spinee.2008.07.008","article-title":"Cortical bone trajectory for lumbar pedicle screws","volume":"9","author":"Santoni BG","year":"2009","journal-title":"Spine J."},{"issue":"5","key":"ref2","first-page":"E497","article-title":"Cortical bone trajectory for thoracic pedicle screws: a technical note","volume":"30","author":"Matsukawa K","year":"2014","journal-title":"J Spinal Disord Tech."},{"issue":"4","key":"ref3","doi-asserted-by":"crossref","first-page":"E240","DOI":"10.1097\/BRS.0000000000000116","article-title":"In vivo analysis of insertional torque during pedicle screwing using cortical bone trajectory technique","volume":"39","author":"Matsukawa K","year":"2014","journal-title":"Spine (Phila Pa 1976)"},{"issue":"4","key":"ref4","doi-asserted-by":"crossref","first-page":"416","DOI":"10.3171\/2014.9.SPINE1484","article-title":"Should we use cortical bone screws for cortical bone trajectory?","volume":"22","author":"Ueno M","year":"2015","journal-title":"J Neurosurg Spine."},{"issue":"5","key":"ref5","doi-asserted-by":"crossref","first-page":"600","DOI":"10.3171\/2013.7.SPINE13191","article-title":"Posterior corrective fusion using a double-trajectory technique (cortical bone trajectory combined with traditional trajectory) for degenerative lumbar scoliosis with osteoporosis","volume":"19","author":"Ueno M","year":"2013","journal-title":"J Neurosurg Spine."},{"issue":"22","key":"ref6","doi-asserted-by":"crossref","first-page":"E1297","DOI":"10.1097\/BRS.0000000000000553","article-title":"Effect of physiological loads on cortical and traditional pedicle screw fixation","volume":"39","author":"Baluch DA","year":"2014","journal-title":"Spine (Phila Pa 1976)"},{"issue":"10","key":"ref7","doi-asserted-by":"crossref","first-page":"1635","DOI":"10.1007\/s00586-011-1892-5","article-title":"Factors affecting the accurate placement of percutaneous pedicle screws during minimally invasive transforaminal lumbar interbody fusion","volume":"20","author":"Kim MC","year":"2011","journal-title":"Eur Spine J."},{"issue":"6","key":"ref8","doi-asserted-by":"crossref","first-page":"E248","DOI":"10.1097\/BSD.0b013e318288ac39","article-title":"Morphometric measurement of cortical bone trajectory for lumbar pedicle screw insertion using computed tomography","volume":"26","author":"Matsukawa K","year":"2013","journal-title":"J Spinal Disord Tech."},{"issue":"6","key":"ref9","doi-asserted-by":"crossref","first-page":"2386","DOI":"10.1177\/0300060518762986","article-title":"Anatomical and radiologic characteristics of isthmus parameters in guiding pedicle screw placement","volume":"46","author":"Rexiti P","year":"2018","journal-title":"J Int Med Res."},{"issue":"8","key":"ref10","first-page":"2413","article-title":"Measurement of lumbar isthmus parameters for novel starting points for cortical bone trajectory screws using computed radiography","volume":"10","author":"Rexiti P","year":"2018","journal-title":"Am J Transl Res."},{"issue":"12","key":"ref11","first-page":"1213","article-title":"Anatomic study on lumbar cortical bone trajectory of adults","author":"Chen W","year":"2015","journal-title":"Chin J Orthop."},{"issue":"6","key":"ref12","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1097\/00007632-199106000-00009","article-title":"Importance of bone mineral density in instrumented spine fusions","volume":"16","author":"Wittenberg RH","year":"1991","journal-title":"Spine (Phila Pa 1976)"},{"issue":"12","key":"ref13","doi-asserted-by":"crossref","first-page":"1673","DOI":"10.1097\/00007632-199309000-00016","article-title":"Pedicle screw pullout strength. Correlation with insertional torque.","volume":"18","author":"Zdeblick TA","year":"1993","journal-title":"Spine (Phila Pa 1976)"},{"issue":"11","key":"ref14","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.2106\/00004623-199911000-00003","article-title":"Complications associated with pedicle screws","volume":"81","author":"Lonstein JE","year":"1999","journal-title":"J Bone Joint Surg Am."},{"issue":"15","key":"ref15","doi-asserted-by":"crossref","first-page":"E873","DOI":"10.1097\/BRS.0000000000000983","article-title":"Evaluation of the fixation strength of pedicle screws using cortical bone trajectory: what is the ideal trajectory for optimal fixation?","volume":"40","author":"Matsukawa K","year":"2015","journal-title":"Spine (Phila Pa 1976)"},{"issue":"3","key":"ref16","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1111\/os.12122","article-title":"Isthmus-guided cortical bone trajectory for pedicle screw insertion","volume":"6","author":"Iwatsuki K","year":"2015","journal-title":"Orthop Surg."},{"issue":"9","key":"ref17","doi-asserted-by":"crossref","first-page":"716","DOI":"10.2176\/nmc.st.2013-0395","article-title":"Midline lumbar fusion with cortical bone trajectory screw","volume":"54","author":"Mizuno M","year":"2014","journal-title":"Neurol Med Chir."},{"issue":"3","key":"ref18","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1111\/os.12122","article-title":"Isthmus-guided cortical bone trajectory for pedicle screw insertion","volume":"6","author":"Iwatsuki K","year":"2014","journal-title":"Orthop Surg."}],"container-title":["Revista da Associa\u00e7\u00e3o M\u00e9dica Brasileira"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_pdf&pid=S0104-42302022000600754&tlng=en","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,26]],"date-time":"2022-07-26T20:23:09Z","timestamp":1658866989000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S0104-42302022000600754&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6]]},"references-count":18,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2022,6]]}},"alternative-id":["S0104-42302022000600754"],"URL":"https:\/\/doi.org\/10.1590\/1806-9282.20210729","relation":{},"ISSN":["1806-9282","0104-4230"],"issn-type":[{"value":"1806-9282","type":"electronic"},{"value":"0104-4230","type":"print"}],"subject":[],"published":{"date-parts":[[2022,6]]}}}