{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T18:34:58Z","timestamp":1770489298802,"version":"3.49.0"},"reference-count":18,"publisher":"FapUNIFESP (SciELO)","issue":"4","license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"am","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Rev. Assoc. Med. Bras."],"DOI":"10.1590\/1806-9282.20230998","type":"journal-article","created":{"date-parts":[[2024,5,3]],"date-time":"2024-05-03T10:29:41Z","timestamp":1714732181000},"source":"Crossref","is-referenced-by-count":2,"title":["Factors of mortality in patients with cardiac implantable electronic device: 5-year experience"],"prefix":"10.1590","volume":"70","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2673-1971","authenticated-orcid":false,"given":"Kemal","family":"G\u00f6\u00e7er","sequence":"first","affiliation":[{"name":"Kahramanmaras Sutcu Imam University,  Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5793-7978","authenticated-orcid":false,"given":"Ahmet \u00c7a\u011fr\u0131","family":"Aykan","sequence":"additional","affiliation":[{"name":"Kahramanmaras Sutcu Imam University,  Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7979-838X","authenticated-orcid":false,"given":"Akif Serhat","family":"Balcio\u011flu","sequence":"additional","affiliation":[{"name":"Kahramanmaras Sutcu Imam University,  Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1939-1008","authenticated-orcid":false,"given":"Ekrem","family":"Aksu","sequence":"additional","affiliation":[{"name":"Kahramanmaras Sutcu Imam University,  Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1627-6816","authenticated-orcid":false,"given":"Murat","family":"Kaniyolu","sequence":"additional","affiliation":[{"name":"Kahramanmaras Sutcu Imam University,  Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8927-6895","authenticated-orcid":false,"given":"Musa","family":"Da\u011fli","sequence":"additional","affiliation":[{"name":"Kahramanmaras Sutcu Imam University,  Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-1674-684X","authenticated-orcid":false,"given":"Naime S\u0131la","family":"G\u00f6\u00e7er","sequence":"additional","affiliation":[{"name":"Necip Faz\u0131l City Hospital,  Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"530","published-online":{"date-parts":[[2024]]},"reference":[{"issue":"11","key":"ref1","doi-asserted-by":"crossref","first-page":"946","DOI":"10.1016\/j.cjco.2022.07.010","article-title":"Treatment and prevention of cardiovascular implantable electronic device (CIED) infections","volume":"4","author":"Phillips P","year":"2022","journal-title":"CJC Open"},{"issue":"3","key":"ref2","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1002\/joa3.12516","article-title":"Postimplantation pocket hematoma increases risk of cardiac implantable electronic device infection: a meta-analysis","volume":"37","author":"Kewcharoen J","year":"2021","journal-title":"J Arrhythm"},{"issue":"5","key":"ref3","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1007\/s10840-022-01389-5","article-title":"A call for large-scale CIED recycling","volume":"66","author":"Alyesh D","year":"2023","journal-title":"J Interv Card Electrophysiol"},{"issue":"5","key":"ref4","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1093\/europace\/euv053","article-title":"Risk factors for cardiac implantable electronic device infection: a systematic review and meta-analysis","volume":"17","author":"Polyzos KA","year":"2015","journal-title":"Europace"},{"issue":"7","key":"ref5","doi-asserted-by":"crossref","first-page":"750","DOI":"10.1016\/S0002-9149(01)01845-8","article-title":"Long-term infection rates associated with the pectoral versus abdominal approach to cardioverter- defibrillator implants","volume":"88","author":"Mela T","year":"2001","journal-title":"Am J Cardiol"},{"issue":"7","key":"ref6","doi-asserted-by":"crossref","first-page":"2599","DOI":"10.3390\/jcm12072599","article-title":"Low occurrence of infections and death in a real-world cohort of patients with cardiac implantable electronic devices","volume":"12","author":"Imberti JF","year":"2023","journal-title":"J Clin Med"},{"issue":"4","key":"ref7","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.joa.2016.02.004","article-title":"Lead extractions in patients with cardiac implantable electronic device infections: single center experience","volume":"32","author":"Goya M","year":"2016","journal-title":"J Arrhythm"},{"issue":"9","key":"ref8","doi-asserted-by":"crossref","first-page":"1334","DOI":"10.1093\/europace\/eus044","article-title":"Microbiology of cardiac implantable electronic device infections","volume":"14","author":"Bongiorni MG","year":"2012","journal-title":"Europace"},{"issue":"8","key":"ref9","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1016\/j.hrthm.2010.05.016","article-title":"Cardiac implantable electronic device infections: presentation, management, and patient outcomes","volume":"7","author":"Tarakji KG","year":"2010","journal-title":"Heart Rhythm"},{"issue":"8","key":"ref10","first-page":"715","article-title":"The effect of a single dose of prophylactic vancomycin prior to peripherally inserted central catheter removal on sepsis","volume":"27","author":"Baker M","year":"2022","journal-title":"J Pediatr Pharmacol Ther"},{"issue":"11","key":"ref11","doi-asserted-by":"crossref","DOI":"10.1161\/JAHA.115.002539","article-title":"Importance of implantable cardioverter-defibrillator back-up in cardiac resynchronization therapy recipients: a systematic review and meta-analysis","volume":"4","author":"Barra S","year":"2015","journal-title":"J Am Heart Assoc"},{"issue":"1","key":"ref12","doi-asserted-by":"crossref","DOI":"10.1136\/openhrt-2017-000681","article-title":"Clinical presentation of CIED infection following initial implant versus reoperation for generator change or lead addition","volume":"5","author":"Harper MW","year":"2018","journal-title":"Open Heart"},{"issue":"2","key":"ref13","first-page":"99","article-title":"Anticoagulant therapy during cardiovascular implantable electronic device procedures","volume":"19","author":"Daubarait\u0117 A","year":"2023","journal-title":"Postepy Kardiol Interwencyjnej"},{"issue":"9","key":"ref14","doi-asserted-by":"crossref","first-page":"817453","DOI":"10.3389\/fcvm.2022.817453","article-title":"Effect of a novel pocket compression device on hematomas following cardiac electronic device implantation in patients receiving direct oral anticoagulants","volume":"9","author":"Fei YP","year":"2022","journal-title":"Front Cardiovasc Med"},{"issue":"2","key":"ref15","doi-asserted-by":"crossref","DOI":"10.1136\/openhrt-2022-002096","article-title":"Remote monitoring in patients with heart failure with cardiac implantable electronic devices: a systematic review and meta-analysis","volume":"9","author":"McGee MJ","year":"2022","journal-title":"Open Heart"},{"issue":"2","key":"ref16","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1111\/pace.12514","article-title":"The impact of changing antiseptic skin preparation agent used for cardiac implantable electronic device (CIED) procedures on the risk of infection","volume":"38","author":"Qintar M","year":"2015","journal-title":"Pacing Clin Electrophysiol"},{"issue":"7","key":"ref17","doi-asserted-by":"crossref","first-page":"1092","DOI":"10.1093\/europace\/euu293","article-title":"Preoperative skin antiseptics for prevention of cardiac implantable electronic device infections: a historical-controlled interventional trial comparing aqueous against alcoholic povidone-iodine solutions","volume":"17","author":"Costa A","year":"2015","journal-title":"Europace"},{"issue":"2","key":"ref18","first-page":"161","article-title":"[Pacemaker infection in fragile patients]","volume":"34","author":"Casorelli E","year":"2023","journal-title":"Herzschrittmacherther Elektrophysiol"}],"container-title":["Revista da Associa\u00e7\u00e3o M\u00e9dica Brasileira"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_pdf&pid=S0104-42302024000400610&tlng=en","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,3]],"date-time":"2024-05-03T10:29:52Z","timestamp":1714732192000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S0104-42302024000400610&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024]]},"references-count":18,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024]]}},"alternative-id":["S0104-42302024000400610"],"URL":"https:\/\/doi.org\/10.1590\/1806-9282.20230998","relation":{},"ISSN":["1806-9282","0104-4230"],"issn-type":[{"value":"1806-9282","type":"electronic"},{"value":"0104-4230","type":"print"}],"subject":[],"published":{"date-parts":[[2024]]},"article-number":"e20230998"}}