{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T17:45:48Z","timestamp":1772819148168,"version":"3.50.1"},"reference-count":41,"publisher":"FapUNIFESP (SciELO)","license":[{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"am","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Braz. oral res."],"abstract":"<jats:p>Abstract Implant overdenture attachments serve as the crucial link between dental implants and removable dentures, significantly enhancing the stability, retention, and function of the prosthesis. This study was designed to assess the effectiveness of locator and TITACH attachments in retaining mandibular two-implant overdentures, maximum bite force, and marginal bone loss. The study involved 36 edentulous patients, each receiving new complete dentures (CDs) designed with the bilateral balanced occlusal concept. Two implants were positioned in the mandibular canine regions. Participants were randomly assigned to two equal groups: Group I (LOA) with overdentures using locator attachments, and Group II (TIA) with overdentures using TITACH attachments. Retention and maximum bite forces were measured using a digital force meter and bite force transducers at baseline (T0), and at 6 months (T6), and 12 months (T12) post-insertion. After insertion, marginal bone loss (MBL) was evaluated using digital periapical radiographs at T6 and T12. Retention significantly decreased over time across all groups (p = 0.024 for CD, p &lt; 0.001 for LOA and TIA). Maximum bite forces significantly declined for LOA (p = 0.007) and TIA (p = 0.003) at all measurement intervals. TIA demonstrated the highest retention and bite forces, followed by LOA, while CDs exhibited the lowest retention and bite forces. TIA was associated with significantly greater MBL than LOA (p = 0.002 and p &lt; 0.001 for TIA). TITACH attachments showed superior retention and maximum bite force compared to locator attachments. Both attachment types offered improved retention and maximum bite forces relative to complete dentures. Additionally, locator attachments were associated with less peri-implant bone loss than TITACH attachments.<\/jats:p>","DOI":"10.1590\/1807-3107bor-2026.vol40.005","type":"journal-article","created":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T11:36:09Z","timestamp":1772796969000},"source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of locator versus TITACH attachments for mandibular 2-implant overdentures: a one-year randomized controlled clinical trial"],"prefix":"10.1590","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3216-7361","authenticated-orcid":false,"given":"Heba Wageh","family":"ABOZAED","sequence":"first","affiliation":[{"name":"Prince Sattam bin Abdulaziz University,  Saudi Arabia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-9941-9433","authenticated-orcid":false,"given":"Mohammed Ahmed","family":"ELADROSI","sequence":"additional","affiliation":[{"name":"Mansoura University,  Egypt"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9514-6931","authenticated-orcid":false,"given":"Moustafa Abdou","family":"ELSYAD","sequence":"additional","affiliation":[{"name":"Mansoura University,  Egypt"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"530","published-online":{"date-parts":[[2026]]},"reference":[{"issue":"1","key":"ref1","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.prosdent.2017.09.010","article-title":"Modified retention and stability criteria for complete denture wearers: a risk assessment tool for impaired masticatory ability and oral health-related quality of life","volume":"120","author":"Limpuangthip N","year":"2018","journal-title":"J Prosthet Dent"},{"issue":"1","key":"ref2","doi-asserted-by":"crossref","DOI":"10.1590\/1807-3107BOR-2016.vol30.0102","article-title":"Impact of mandibular conventional denture and overdenture on quality of life and masticatory efficiency","volume":"30","author":"Cardoso RG","year":"2016","journal-title":"Braz Oral Res"},{"issue":"4","key":"ref3","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1038\/sj.bdj.2009.728","article-title":"Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients: the York Consensus Statement","volume":"207","author":"Thomason JM","year":"2009","journal-title":"Br Dent J"},{"issue":"5","key":"ref4","doi-asserted-by":"crossref","first-page":"1103","DOI":"10.11607\/jomi.6363","article-title":"Clinical and radiographic evaluation of bar, telescopic, and locator attachments for implant-stabilized overdentures in patients with mandibular atrophied ridges: a randomized controlled clinical trial","volume":"33","author":"ELsyad MA","year":"2018","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"1","key":"ref5","first-page":"1","article-title":"Attachments used with implant supported overdenture","volume":"2","author":"Alqutaibi AY","year":"2016","journal-title":"Int Dental Med J Adv Res"},{"issue":"2","key":"ref6","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1111\/clr.13552","article-title":"Clinical denture base deformation with different attachments used to stabilize implant overdentures: A crossover study","volume":"31","author":"ELsyad MA","year":"2020","journal-title":"Clin Oral Implants Res"},{"issue":"4","key":"ref7","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1111\/cid.13093","article-title":"Prosthetic complications and maintenance of different attachments used to stabilize mandibular 2-implant overdentures in patients with atrophied ridges: a 5-year randomized controlled clinical trial","volume":"24","author":"ELsyad MA","year":"2022","journal-title":"Clin Implant Dent Relat Res"},{"issue":"1","key":"ref8","doi-asserted-by":"crossref","first-page":"106","DOI":"10.21608\/adjalexu.2020.79970","article-title":"Evaluation of implant-assisted mandibular overdenture with new metal to metal interface attachment system (in vitro study)","volume":"45","author":"Ramadan RE","year":"2020","journal-title":"Alex Dent J"},{"issue":"1","key":"ref9","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/S0022-3913(11)60088-7","article-title":"Randomized, prospective, clinical evaluation of prosthodontic modalities for mandibular implant overdenture treatment","volume":"106","author":"Burns DR","year":"2011","journal-title":"J Prosthet Dent"},{"issue":"5","key":"ref10","doi-asserted-by":"crossref","first-page":"738.e1","DOI":"10.1016\/j.prosdent.2020.01.009","article-title":"Retention of mandibular implant-retained overdentures with two different attachment designs: an in vitro study","volume":"123","author":"Ramadan RE","year":"2020","journal-title":"J Prosthet Dent"},{"issue":"4","key":"ref11","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1563\/1548-1336-35.4.196","article-title":"Effect of implants on maximum bite force in edentulous patients","volume":"35","author":"Rismanchian M","year":"2009","journal-title":"J Oral Implantol"},{"issue":"4","key":"ref12","doi-asserted-by":"crossref","first-page":"e28","DOI":"10.1111\/clr.12324","article-title":"Marginal bone loss as success criterion in implant dentistry: beyond 2 mm","volume":"26","author":"Galindo-Moreno P","year":"2015","journal-title":"Clin Oral Implants Res"},{"issue":"5","key":"ref13","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1111\/j.1600-0501.2009.01879.x","article-title":"Resilient liner vs. clip attachment effect on peri-implant tissues of bar-implant-retained mandibular overdenture: a 1-year clinical and radiographical study","volume":"21","author":"Elsyad MA","year":"2010","journal-title":"Clin Oral Implants Res"},{"issue":"2","key":"ref14","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1016\/S0022-3913(10)60107-2","article-title":"Defining available restorative space for implant overdentures","volume":"104","author":"Ahuja S","year":"2010","journal-title":"J Prosthet Dent"},{"issue":"4","key":"ref15","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1016\/S0901-5027(88)80047-X","article-title":"A classification of the edentulous jaws","volume":"17","author":"Cawood JI","year":"1988","journal-title":"Int J Oral Maxillofac Surg"},{"key":"ref16","series-title":"Tissue-integrated prostheses: osseointegration in clinical dentistry","volume-title":"Introduction to osseointegration","author":"Branemark P-I","year":"1985"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"S605","DOI":"10.4103\/jpbs.jpbs_733_21","article-title":"Comparison of retention of two different attachment systems used in implant-supported overdentures","volume":"14","author":"Dhamodaran S","year":"2022","journal-title":"J Pharm Bioallied Sci"},{"issue":"2","key":"ref18","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1016\/j.prosdent.2022.06.027","article-title":"A technique for measuring the clinical retentive forces of mandibular implant-supported overdentures","volume":"132","author":"Raafat MH","year":"2024","journal-title":"J Prosthet Dent"},{"issue":"4","key":"ref19","doi-asserted-by":"crossref","first-page":"239","DOI":"10.4047\/jap.2020.12.4.239","article-title":"Survival rate and clinical evaluation of the implants in implant assisted removable partial dentures: surveyed crown and overdenture","volume":"12","author":"Kang SH","year":"2020","journal-title":"J Adv Prosthodont"},{"issue":"2","key":"ref20","first-page":"191","article-title":"Complications and maintenance requirements for fixed prostheses and overdentures in the edentulous mandible: a 5-year report","volume":"9","author":"Hemmings KW","year":"1994","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"5","key":"ref21","doi-asserted-by":"crossref","first-page":"1044","DOI":"10.11607\/jomi.9610","article-title":"Patient satisfaction and prosthetic complications of maxillary implant overdentures opposing mandibular implant overdentures with bar, telescopic, and stud attachments: a 1-year prospective trial","volume":"37","author":"Hamdy Fayek N","year":"2022","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"0","key":"ref22","doi-asserted-by":"crossref","DOI":"10.1177\/1758736015576009","article-title":"Effect of attachment type on load distribution to implant abutments and the residual ridge in mandibular implant-supported overdentures","volume":"6","author":"Yoda N","year":"2015","journal-title":"J Dent Biomech"},{"issue":"4","key":"ref23","doi-asserted-by":"crossref","first-page":"380","DOI":"10.4103\/0972-4052.191284","article-title":"In vitro retention force measurement for three different attachment systems for implant-retained overdenture","volume":"16","author":"Reda KM","year":"2016","journal-title":"J Indian Prosthodont Soc"},{"issue":"5","key":"ref24","first-page":"429","article-title":"Attachment systems for mandibular two-implant overdentures: a review of in vitro investigations on retention and wear features","volume":"22","author":"Alsabeeha NH","year":"2009","journal-title":"Int J Prosthodont"},{"issue":"1","key":"ref25","doi-asserted-by":"crossref","first-page":"23","DOI":"10.21608\/aadj.2023.296414","article-title":"Impact of TITACH attachment on the retention for mandibular implant overdentures","volume":"6","author":"Eladrosi MA","year":"2023","journal-title":"Al-Azhar Assiut Dental Journal"},{"issue":"5","key":"ref26","doi-asserted-by":"crossref","first-page":"982","DOI":"10.11607\/jomi.8399","article-title":"Milled Bar with PEEK and metal housings for inclined implants supporting mandibular overdentures: 1-year clinical, prosthetic, and patient-based outcomes","volume":"35","author":"Abdraboh AE","year":"2020","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"5","key":"ref27","doi-asserted-by":"crossref","first-page":"1106","DOI":"10.11607\/jomi.3621","article-title":"In vitro comparison of the retentive properties of ball and locator attachments for implant overdentures","volume":"29","author":"T\u00fcrk PE","year":"2014","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"3","key":"ref28","doi-asserted-by":"crossref","first-page":"543","DOI":"10.11607\/jomi.7954","article-title":"The influence of implant inclination on retention and peri-implant stresses of stud-retained implant overdentures during axial and nonaxial dislodgments: an in vitro study","volume":"35","year":"2020","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"1-49","key":"ref29","article-title":"Clinical evaluation of the biting force of the mandibular implant supported overdenture by two conventional and two mini implants","volume":"23","author":"Shoeib AM","year":"2020","journal-title":"Al-Azhar J Dental Sci"},{"issue":"4","key":"ref30","doi-asserted-by":"crossref","first-page":"361","DOI":"10.4103\/jips.jips_76_17","article-title":"A comparative evaluation of chewing efficiency, masticatory bite force, and patient satisfaction between conventional denture and implant-supported mandibular overdenture: an in vivo study","volume":"17","author":"Sharma AJ","year":"2017","journal-title":"J Indian Prosthodont Soc"},{"issue":"6","key":"ref31","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1563\/AAID-JOI-D-09-00009R1.1","article-title":"Five-year study of implant placement in regenerated bone and rehabilitation with telescopic crown retained dentures: a case report","volume":"35","author":"Zafiropoulos GG","year":"2009","journal-title":"J Oral Implantol"},{"issue":"9","key":"ref32","doi-asserted-by":"crossref","first-page":"708","DOI":"10.1177\/154405910408300910","article-title":"Masticatory function with implant-supported overdentures","volume":"83","author":"Kampen FM","year":"2004","journal-title":"J Dent Res"},{"issue":"10","key":"ref33","doi-asserted-by":"crossref","first-page":"e169","DOI":"10.1111\/clr.12980","article-title":"Electromyography evaluation of masseter and temporalis, bite force, and quality of life in elderly patients during the adaptation of mandibular implant-supported overdentures","volume":"28","author":"S\u00f4nego MV","year":"2017","journal-title":"Clin Oral Implants Res"},{"issue":"7","key":"ref34","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.1177\/00220345000790071501","article-title":"Biting and chewing in overdentures, full dentures, and natural dentitions","volume":"79","author":"Fontijn-Tekamp FA","year":"2000","journal-title":"J Dent Res"},{"issue":"2","key":"ref35","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1111\/j.1600-0501.2011.02213.x","article-title":"Masseter muscle thickness, chewing efficiency and bite force in edentulous patients with fixed and removable implant-supported prostheses: a cross-sectional multicenter study","volume":"23","author":"M\u00fcller F","year":"2012","journal-title":"Clin Oral Implants Res"},{"issue":"7","key":"ref36","first-page":"487","article-title":"Changes in the edentulous maxilla with ball and telescopic attachments of implant-retained mandibular overdentures: a 4-year retrospective study","volume":"44","author":"ELsyad MA","year":"2013","journal-title":"Quintessence Int (Berl)"},{"issue":"6","key":"ref37","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1111\/clr.12861","article-title":"Chewing efficiency and maximum bite force with different attachment systems of implant overdentures: a crossover study","volume":"28","author":"Elsyad MA","year":"2017","journal-title":"Clin Oral Implants Res"},{"issue":"4","key":"ref38","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/j.prosdent.2007.02.006","article-title":"Photoelastic stress analysis of various retention mechanisms on 3-implant-retained mandibular overdentures","volume":"97","author":"Celik G","year":"2007","journal-title":"J Prosthet Dent"},{"issue":"1","key":"ref39","doi-asserted-by":"crossref","first-page":"18","DOI":"10.4103\/0972-4052.16336","article-title":"Biomechanics of dental implants: a FEM study","volume":"5","author":"Jingade RR","year":"2005","journal-title":"J Indian Prosthodont Soc"},{"issue":"4","key":"ref40","first-page":"24","article-title":"The use of a self-aligning, low-maintenance overdenture attachment","volume":"19","author":"Schneider AL","year":"2000","journal-title":"Dent Today"},{"issue":"2","key":"ref41","doi-asserted-by":"crossref","first-page":"129","DOI":"10.21608\/ajdsm.2022.162665.1367","article-title":"Radiographic evaluation of bar\/locator versus bar\/ball for implant assisted complete mandibular overdenture: a 5-year retrospective study","volume":"26","author":"Abozaed HW","year":"2023","journal-title":"Al-Azhar J Dent Sci"}],"container-title":["Brazilian Oral Research"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_pdf&pid=S1806-83242026000103801&tlng=en","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T11:36:15Z","timestamp":1772796975000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S1806-83242026000103801&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026]]},"references-count":41,"alternative-id":["S1806-83242026000103801"],"URL":"https:\/\/doi.org\/10.1590\/1807-3107bor-2026.vol40.005","relation":{},"ISSN":["1807-3107","1806-8324"],"issn-type":[{"value":"1807-3107","type":"electronic"},{"value":"1806-8324","type":"print"}],"subject":[],"published":{"date-parts":[[2026]]},"article-number":"e005"}}