{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T10:59:23Z","timestamp":1780484363918,"version":"3.54.1"},"reference-count":26,"publisher":"FapUNIFESP (SciELO)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Dental Press J. Orthod."],"published-print":{"date-parts":[[2014,6]]},"abstract":"<jats:p> OBJECTIVE: The aim of this study was to cephalometrically assess the skeletal and dentoalveolar effects of Class II malocclusion treatment performed with the Jones Jig appliance followed by fixed appliances. METHODS: The sample comprised 25 patients with Class II malocclusion treated with the Jones Jig appliance followed by fixed appliances, at a mean initial age of 12.90 years old. The mean time of the entire orthodontic treatment was 3.89 years. The distalization phase lasted for 0.85 years, after which the fixed appliance was used for 3.04 years. Cephalograms were used at initial (T1), post-distalization (T2) and final phases of treatment (T3). For intragroup comparison of the three phases evaluated, dependent ANOVA and Tukey tests were used. RESULTS: Jones Jig appliance did not interfere in the maxillary and mandibular component and did not change maxillomandibular relationship. Jones Jig appliance promoted distalization of first molars with anchorage loss, mesialization and significant extrusion of first and second premolars, as well as a significant increase in anterior face height at the end of treatment. The majority of adverse effects that occur during intraoral distalization are subsequently corrected during corrective mechanics. Buccal inclination and protrusion of mandibular incisors were identified. By the end of treatment, correction of overjet and overbite was observed. CONCLUSIONS: Jones Jig appliance promoted distalization of first molars with anchorage loss represented by significant mesial movement and extrusion of first and second premolars, in addition to a significant increase in anterior face height.<\/jats:p>","DOI":"10.1590\/2176-9451.19.3.044-051.oar","type":"journal-article","created":{"date-parts":[[2014,9,27]],"date-time":"2014-09-27T14:27:38Z","timestamp":1411828058000},"page":"44-51","source":"Crossref","is-referenced-by-count":11,"title":["Cephalometric effects of the Jones Jig appliance followed by fixed appliances in Class II malocclusion treatment"],"prefix":"10.1590","volume":"19","author":[{"given":"Mayara Paim","family":"Patel","sequence":"first","affiliation":[{"name":"University of S\u00e3o Paulo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 Fernando Castanha","family":"Henriques","sequence":"additional","affiliation":[{"name":"University of S\u00e3o Paulo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karina Maria Salvatore de","family":"Freitas","sequence":"additional","affiliation":[{"name":"UNING\u00c1"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roberto Henrique da Costa","family":"Grec","sequence":"additional","affiliation":[{"name":"University of S\u00e3o Paulo"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"530","reference":[{"issue":"3","key":"ref1","first-page":"177","article-title":"Components of class II malocclusion in children 8-10 years of age","volume":"51","author":"McNamara J","year":"1981","journal-title":"Angle Orthod"},{"issue":"6","key":"ref2","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1016\/j.ajodo.2003.06.006","article-title":"Dentoskeletal effects induced by rapid molar distalization with the first class appliance","volume":"125","author":"Fortini A","year":"2004","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"2","key":"ref3","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/0889-5406(89)90257-6","article-title":"The use of magnets to move molars distally","volume":"96","author":"Gianelly AA","year":"1989","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"11","key":"ref4","first-page":"706","article-title":"The pendulum appliance for Class II non-compliance therapy","volume":"26","author":"Hilgers J","year":"1992","journal-title":"J Clin Orthod"},{"issue":"10","key":"ref5","first-page":"661","article-title":"Rapid Class II molar correction with an open-coil jig","volume":"26","author":"Jones RD","year":"1992","journal-title":"J Clin Orthod"},{"issue":"6","key":"ref6","doi-asserted-by":"crossref","first-page":"1133","DOI":"10.2319\/101507-406.1","article-title":"Maxillary molar distalization with noncompliance intramaxillary appliances in Class II malocclusion. A systematic review","volume":"78","author":"Antonarakis GS","year":"2008","journal-title":"Angle Orthod"},{"issue":"4","key":"ref7","first-page":"558","article-title":"Molar distalization with a modified pendulum appliance--in vitro analysis of the force systems and in vivo study in children and adolescents","volume":"75","author":"Kinzinger GSM","year":"2005","journal-title":"Angle Orthod"},{"issue":"1","key":"ref8","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.ajodo.2005.02.034","article-title":"Osseointegrated implants with pendulum springs for maxillary molar distalization: a cephalometric study","volume":"131","author":"Oncag G","year":"2007","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"5","key":"ref9","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1067\/mod.2000.110332","article-title":"Evaluation of the Jones jig appliance for distal molar movement","volume":"118","author":"Brickman CD","year":"2000","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"2","key":"ref10","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1067\/mod.2003.7","article-title":"Maxillary molar distalization or mandibular enhancement: a cephalometric comparison of comprehensive orthodontic treatment including the pendulum and the Herbst appliances","volume":"123","author":"Burkhardt DR","year":"2003","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"3","key":"ref11","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1016\/j.ajodo.2004.04.031","article-title":"A comparison of two intraoral molar distalization appliances: distal jet versus pendulum","volume":"128","author":"Chiu PP","year":"2005","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"2","key":"ref12","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1067\/mod.2001.114645","article-title":"Posttreatment evaluation of the distal jet appliance","volume":"120","author":"Ngantung V","year":"2001","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"6","key":"ref13","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1016\/S0889-5406(96)80041-2","article-title":"Evaluation of an intraoral maxillary molar distalization technique","volume":"110","author":"Ghosh J","year":"1996","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"3","key":"ref14","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/S0889-5406(98)70215-X","article-title":"Dental and skeletal changes after intraoral molar distalization with sectional jig assembly","volume":"114","author":"Gulati S","year":"1998","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"1","key":"ref15","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/S0889-5406(00)70247-2","article-title":"Comparison of Jones jig molar distalization appliance with extraoral traction","volume":"117","author":"Haydar S","year":"2000","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"3","key":"ref16","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1016\/j.ajodo.2007.01.035","article-title":"Comparative distalization effects of Jones jig and pendulum appliances","volume":"135","author":"Patel MP","year":"2009","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"2","key":"ref17","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/S0889-5406(99)70343-4","article-title":"Analysis of rapid maxillary molar distal movement without patient cooperation","volume":"115","author":"Runge ME","year":"1999","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"ref18","series-title":"Statistical methods for medical and biological students","author":"Dahlberg G","year":"1940"},{"issue":"5","key":"ref19","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1016\/0002-9416(83)90322-6","article-title":"The analysis of errors in orthodontic measurements","volume":"83","author":"Houston WJ","year":"1983","journal-title":"Am J Orthod"},{"issue":"4","key":"ref20","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1016\/j.ajodo.2005.12.003","article-title":"Dentoalveolar and skeletal changes associated with the pendulum appliance followed by fixed orthodontic treatment","volume":"129","author":"Angelieri F","year":"2006","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"ref21","series-title":"Atlas de crescimento craniofacial","author":"Martins DR","year":"1998"},{"issue":"3","key":"ref22","first-page":"161","article-title":"The morphological and morphogenetic basis for craniofacial form and pattern","volume":"41","author":"Enlow DH","year":"1971","journal-title":"Angle Orthod"},{"issue":"5","key":"ref23","first-page":"481","article-title":"Evaluation of maxillary molar distalization with the distal jet: a comparison with other contemporary methods","volume":"72","author":"Bolla E","year":"2002","journal-title":"Angle Orthod"},{"issue":"3","key":"ref24","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/S0889-5406(00)70238-1","article-title":"Dentoalveolar and skeletal changes associated with the pendulum appliance","volume":"117","author":"Bussick T","year":"2000","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"4","key":"ref25","first-page":"532","article-title":"Efficiency of noncompliance simultaneous first and second upper molar distalization: a three-dimensional tooth movement analysis","volume":"75","author":"Mavropoulos A","year":"2005","journal-title":"Angle Orthod"},{"issue":"5","key":"ref26","doi-asserted-by":"crossref","first-page":"604.e1","DOI":"10.1016\/j.ajodo.2008.03.013","article-title":"Orthodontic treatment of Class II malocclusion with miniscrew implants","volume":"134","author":"Papadopoulos MA","year":"2008","journal-title":"Am J Orthod Dentofacial Orthop"}],"container-title":["Dental Press Journal of Orthodontics"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/pdf\/dpjo\/v19n3\/2176-9451-dpjo-19-03-00044.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,5,27]],"date-time":"2017-05-27T18:08:56Z","timestamp":1495908536000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S2176-94512014000300044&lng=en&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,6]]},"references-count":26,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2014,6]]}},"alternative-id":["S2176-94512014000300044"],"URL":"https:\/\/doi.org\/10.1590\/2176-9451.19.3.044-051.oar","relation":{},"ISSN":["2176-9451"],"issn-type":[{"value":"2176-9451","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,6]]}}}