{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T11:16:25Z","timestamp":1780485385240,"version":"3.54.1"},"reference-count":14,"publisher":"FapUNIFESP (SciELO)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Dental Press J. Orthod."],"published-print":{"date-parts":[[2015,4]]},"abstract":"<jats:p> OBJECTIVE: The purpose of this study was to assess the influence of magnification and superimposition of structures on CBCT-generated lateral cephalometric radiographs (LCR) using different segments of the cranium. METHODS: CBCT scans of 10 patients were selected. Four LCR were generated using Dolphin Imaging(r) software: full-face, right side, left side and center of the head. A total of 40 images were imported into Radiocef Studio 2(r), and the angles of the most common cephalometric analyses were traced by the same observer twice and within a 10-day interval. Statistical analyses included intraexaminer agreement and comparison between methods by means of intraclass correlation coefficient (ICC) and Bland-Altman agreement tests. RESULTS: Intraexaminer agreement of the angles assessed by ICC was excellent (&gt; 0.90) for 83% of measurements, good (between 0.75 and 0.90) for 15%, and moderate (between 0.50 and 0.75) for 2% of measurements. The comparison between methods by ICC was excellent for 68% of measurements, good for 26%, and moderate for 6%. Variables presenting wider confidence intervals (&gt; 6o) in the Bland-Altman tests, in intraexaminer assessment, were: mandibular incisor angle, maxillary incisor angle, and occlusal plane angle. And in comparison methods the variables with wider confidence interval were: mandibular incisor, maxillary incisor, GoGn, occlusal plane angle, Frankfort horizontal plane (FHP), and CoA. CONCLUSION: Superimposition of structures seemed to influence the results more than magnification, and neither one of them significantly influenced the measurements. Considerable individual variability may occur, especially for mandibular and maxillary incisors, FHP and occlusal plane.<\/jats:p>","DOI":"10.1590\/2176-9451.20.2.029-034.oar","type":"journal-article","created":{"date-parts":[[2015,5,8]],"date-time":"2015-05-08T16:47:28Z","timestamp":1431103648000},"page":"29-34","source":"Crossref","is-referenced-by-count":8,"title":["Influence of magnification and superimposition of structures on cephalometric diagnosis"],"prefix":"10.1590","volume":"20","author":[{"given":"Leonardo Koerich de","family":"Paula","sequence":"first","affiliation":[{"name":"Universidade Federal do Rio de Janeiro,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Priscilla de Almeida","family":"Solon-de-Mello","sequence":"additional","affiliation":[{"name":"Universidade Federal do Rio de Janeiro,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claudia Trindade","family":"Mattos","sequence":"additional","affiliation":[{"name":"Universidade Federal Fluminense,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ant\u00f4nio Carlos de Oliveira","family":"Ruellas","sequence":"additional","affiliation":[{"name":"Universidade Federal do Rio de Janeiro,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eduardo Franzotti","family":"Sant'Anna","sequence":"additional","affiliation":[{"name":"Universidade Federal do Rio de Janeiro,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"530","reference":[{"issue":"2","key":"ref1","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/0002-9416(71)90028-5","article-title":"The reliability of head film measurements. 1. Landmark identification","volume":"60","author":"Baumrind S","year":"1971","journal-title":"Am J Orthod"},{"issue":"5","key":"ref2","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1016\/0002-9416(71)90116-3","article-title":"The reliability of head film measurements. 2. Conventional angular and linear measures","volume":"60","author":"Baumrind S","year":"1971","journal-title":"Am J Orthod"},{"issue":"1","key":"ref3","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.tripleo.2008.09.025","article-title":"Image distortion and magnification of 3 digital CCD cephalometric systems","volume":"107","author":"Chadwick JW","year":"2009","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"issue":"3","key":"ref4","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1093\/ejo\/cjh098","article-title":"The effect of head rotation on cephalometric radiographs","volume":"27","author":"Malkoc S","year":"2005","journal-title":"Eur J Orthod"},{"issue":"5","key":"ref5","first-page":"396","article-title":"Effect of head rotation on lateral cephalometric radiographs","volume":"71","author":"Yoon YJ","year":"2001","journal-title":"Angle Orthod"},{"issue":"4","key":"ref6","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1016\/j.ajodo.2004.03.023","article-title":"Comparison between traditional 2-dimensional cephalometry and a 3-dimensional approach on human dry skulls","volume":"126","author":"Adams GL","year":"2004","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"9","key":"ref7","doi-asserted-by":"crossref","first-page":"1558","DOI":"10.1007\/s003300050586","article-title":"A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results","volume":"8","author":"Mozzo P","year":"1998","journal-title":"Eur Radiol"},{"issue":"1","key":"ref8","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1259\/dmfr\/12615645","article-title":"The current status of cone beam computed tomography imaging in orthodontics","volume":"40","author":"Kapila S","year":"2011","journal-title":"Dentomaxillofac Radiol"},{"issue":"3","key":"ref9","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1016\/j.ajodo.2009.04.016","article-title":"Working with DICOM craniofacial images","volume":"136","author":"Grauer D","year":"2009","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"2","key":"ref10","doi-asserted-by":"crossref","first-page":"286","DOI":"10.2319\/030909-135.1","article-title":"Accuracy and landmark error calculation using cone-beam computed tomography-generated cephalograms","volume":"80","author":"Grauer D","year":"2010","journal-title":"Angle Orthod"},{"issue":"5","key":"ref11","doi-asserted-by":"crossref","first-page":"873","DOI":"10.2319\/082907-399.1","article-title":"In vivo comparison of conventional and cone beam CT synthesized cephalograms","volume":"78","author":"Kumar V","year":"2008","journal-title":"Angle Orthod"},{"issue":"5","key":"ref12","doi-asserted-by":"crossref","first-page":"827","DOI":"10.2319\/072711-473.1","article-title":"Validity and reproducibility of cephalometric measurements performed in full and hemifacial reconstructions derived from cone beam computed tomography","volume":"82","author":"Ramirez-Sotelo LR","year":"2012","journal-title":"Angle Orthod"},{"issue":"1","key":"ref13","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1002\/(SICI)1097-0258(19980115)17:1<101::AID-SIM727>3.0.CO;2-E","article-title":"Sample size and optimal designs for reliability studies","volume":"17","author":"Walter SD","year":"1998","journal-title":"Stat Med"},{"issue":"6","key":"ref14","doi-asserted-by":"crossref","first-page":"798","DOI":"10.1016\/j.ajodo.2008.07.008","article-title":"Comparison between conventional and cone-beam computed tomography-generated cephalograms","volume":"134","author":"Cattaneo PM","year":"2008","journal-title":"Am J Orthod Dentofacial Orthop"}],"container-title":["Dental Press Journal of Orthodontics"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/pdf\/dpjo\/v20n2\/2176-9451-dpjo-20-02-00029.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,5,22]],"date-time":"2017-05-22T19:54:55Z","timestamp":1495482895000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S2176-94512015000200029&lng=en&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,4]]},"references-count":14,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2015,4]]}},"alternative-id":["S2176-94512015000200029"],"URL":"https:\/\/doi.org\/10.1590\/2176-9451.20.2.029-034.oar","relation":{},"ISSN":["2176-9451"],"issn-type":[{"value":"2176-9451","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,4]]}}}