{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T16:23:33Z","timestamp":1759335813196},"reference-count":19,"publisher":"FapUNIFESP (SciELO)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Dental Press J. Orthod."],"abstract":"<jats:p>OBJECTIVE: The aim of this study was to assess whether repetitive opening and closure of self-ligating bracket clips can cause plastic deformation of the clip.METHODS: Three types of active\/interactive ceramic self-ligating brackets (n = 20) were tested: In-Ovation C, Quicklear and WOW. A standardized controlled device performed 500 cycles of opening and closure movements of the bracket clip with proper instruments and techniques adapted as recommended by the manufacturer of each bracket type. Two tensile tests, one before and one after the repetitive cycles, were performed to assess the stiffness of the clips. To this end, a custom-made stainless steel 0.40 x 0.40 mm wire was inserted into the bracket slot and adapted to the universal testing machine (EMIC DL2000), after which measurements were recorded. On the loading portion of the loading-unloading curve of clips, the slope fitted a first-degree equation curve to determine the stiffness\/deflection rate of the clip.RESULTS: The results of plastic deformation showed no significant difference among bracket types before and after the 500 cycles of opening and closure (p = 0.811). There were significant differences on stiffness among the three types of brackets (p = 0.005). The WOW bracket had higher mean values, whereas Quicklear bracket had lower values, regardless of the opening\/closure cycle.CONCLUSION: Repetitive controlled opening and closure movements of the clip did not alter stiffness or cause plastic deformation.<\/jats:p>","DOI":"10.1590\/2176-9451.20.4.045-050.oar","type":"journal-article","created":{"date-parts":[[2015,9,2]],"date-time":"2015-09-02T19:14:21Z","timestamp":1441221261000},"page":"45-50","source":"Crossref","is-referenced-by-count":4,"title":["Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements"],"prefix":"10.1590","volume":"20","author":[{"given":"Grace Kelly Martins","family":"Carneiro","sequence":"first","affiliation":[{"name":"Faculdade S\u00e3o Leopoldo Mandic,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juliano Alves","family":"Roque","sequence":"additional","affiliation":[{"name":"Faculdade S\u00e3o Leopoldo Mandic,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aguinaldo Silva Garcez","family":"Segundo","sequence":"additional","affiliation":[{"name":"Faculdade S\u00e3o Leopoldo Mandic,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hideo","family":"Suzuki","sequence":"additional","affiliation":[{"name":"Faculdade S\u00e3o Leopoldo Mandic,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"530","published-online":{"date-parts":[[2015,8]]},"reference":[{"key":"ref1","first-page":"98","article-title":"Frictional forces of ligated plastic and metal edgewise brackets","volume":"21","author":"Ridley J","year":"1979","journal-title":"J Dent Res"},{"issue":"1","key":"ref2","first-page":"29","article-title":"Time saving with self-ligating brackets","volume":"24","author":"Maijer R","year":"1990","journal-title":"J Clin Orthod"},{"issue":"5","key":"ref3","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1016\/S0889-5406(94)70069-9","article-title":"A comparative study of conventional ligation and self- ligation bracket systems","volume":"106","author":"Shivapuja PK","year":"1994","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"5","key":"ref4","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1093\/ejo\/15.5.377","article-title":"A comparison of the forces required to produce tooth movement in vitro using two self-ligating brackets and a pre-adjusted bracket employing two types of ligation","volume":"15","author":"Sims AP","year":"1993","journal-title":"Eur J Orthod"},{"issue":"3","key":"ref5","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1016\/S0889-5406(05)81727-5","article-title":"The influence of bracket design on moment production during axial rotation","volume":"104","author":"Bendar D","year":"1993","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"ref6","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1093\/ejo\/8.3.202","article-title":"Laboratory and intra-oral tests of the degradation of elastic chains","volume":"8","author":"Kuster R","year":"1986","journal-title":"Eur J Orthod"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1093\/ejo\/21.6.649","article-title":"Structural conformation of in vitro and in vivo aged orthodontic elastomeric modules","volume":"21","author":"Eliades T","year":"1999","journal-title":"Eur J Orthod"},{"key":"ref8","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.ajodo.2011.04.019","article-title":"Biofilm retention by 3 methods of ligation on orthodontic brackets: a microbiologic and optical coherence tomography analysis","volume":"140","author":"Garcez AS","year":"2011","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"2","key":"ref9","first-page":"196","article-title":"Orthodontic elastic materials","volume":"46","author":"Wong AK","year":"1976","journal-title":"Angle Orthod"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1093\/ejo\/20.5.589","article-title":"A comparative in vitro study of the frictional characteristics of two types of self-ligating brackets and two types of pre-adjusted edgewise brackets tied with elastomeric ligatures","volume":"20","author":"Thomas S","year":"1998","journal-title":"Eur J Orthod"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1034\/j.1600-0544.2001.40407.x","article-title":"Treatment time, outcome, and patient satisfaction comparisons of Damon and conventional brackets","volume":"4","author":"Eberting JJ","year":"2001","journal-title":"Clin Orthod Res"},{"issue":"1","key":"ref12","first-page":"55","article-title":"Seven clinical principles of interactive twin mechanisms","volume":"31","author":"Voudouris JC","year":"1997","journal-title":"J Clin Orthod"},{"issue":"6","key":"ref13","first-page":"726.e1","article-title":"Systematic review of self-ligating brackets","volume":"137","author":"Chen SS","year":"2010","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"3","key":"ref14","doi-asserted-by":"crossref","first-page":"575","DOI":"10.2319\/081009-454.1","article-title":"Self-ligating brackets in orthodontics. A systematic review","volume":"80","author":"Fleming PS","year":"2010","journal-title":"Angle Orthod"},{"key":"ref15","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1093\/ortho\/30.3.262","article-title":"Self-ligating brackets: where are we now?","volume":"30","author":"Harradine NWT","year":"2003","journal-title":"J Orthod"},{"issue":"3","key":"ref16","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1590\/1679-7757201300063","article-title":"Opening and closure forces of sliding mechanisms of different self-ligating brackets","volume":"21","author":"Gandini P","year":"2013","journal-title":"J Appl Oral Sci"},{"issue":"4","key":"ref17","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/j.ajodo.2004.09.015","article-title":"Intraoral aging of orthodontic materials: the picture we miss and its clinical relevance","volume":"127","author":"Eliades T","year":"2005","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"1","key":"ref18","first-page":"5","article-title":"The History and Development of Self-Ligating Brackets, Semin","volume":"14","author":"Harradine NWT","year":"2008","journal-title":"Orthod"},{"issue":"6","key":"ref19","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1016\/j.ajodo.2007.07.010","article-title":"Changes in the stiffness of the ligating mechanism in retrieved active self-ligating brackets","volume":"132","author":"Pandis N","year":"2007","journal-title":"Am J Orthod Dentofacial Orthop"}],"container-title":["Dental Press Journal of Orthodontics"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/pdf\/dpjo\/v20n4\/2176-9451-dpjo-20-04-00045.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,3,5]],"date-time":"2018-03-05T19:39:09Z","timestamp":1520278749000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S2176-94512015000400045&lng=en&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,8]]},"references-count":19,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2015,8]]}},"alternative-id":["S2176-94512015000400045"],"URL":"https:\/\/doi.org\/10.1590\/2176-9451.20.4.045-050.oar","relation":{},"ISSN":["2177-6709","2176-9451"],"issn-type":[{"value":"2177-6709","type":"electronic"},{"value":"2176-9451","type":"print"}],"subject":[],"published":{"date-parts":[[2015,8]]}}}