{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T22:40:29Z","timestamp":1794696029211,"version":"4.9.1"},"reference-count":18,"publisher":"FapUNIFESP (SciELO)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Arq. Gastroenterol."],"published-print":{"date-parts":[[2012,6]]},"abstract":"<jats:p>CONTEXT: Colonoscopy is currently the gold standard method to examine the colon, the rectum and the terminal ileum. In order to perform the colonoscopy, it is necessary to clean the bowel and use medications that are generally poorly tolerated by the patients. OBJECTIVE: Compare the tolerability, acceptability, safety and efficacy of two solutions used for intestinal preparation for a colonoscopy. METHODS: One hundred patients matched for sex and age were prospective randomized into two groups. Polyethylene glycol group received bisacodyl 10 mg plus 1 L of polyethylene glycol the night before and 1 L on the day of the exam. Mannitol group received bisacodyl 20 mg the day before and 1 L of a 10% mannitol solution on the day of the exam. The diet was the same for both groups. Tolerability and acceptability were measured using previously validated questionnaires. In terms of safety, variations in vital signs before and after the preparation were recorded, in addition to any complications. The quality of the preparation was graded based on the Boston and Ottawa scales. RESULTS: Ninety-six percent (96%) completed the study. As for tolerability, the mannitol preparation group exhibited a significantly higher frequency of nausea, vomiting, abdominal pain, and abdominal distension than polyethylene glycol group (P &lt; 0.05). Acceptability was significantly better in polyethylene glycol group. The polyethylene glycol solution has also previously been shown to be safer than mannitol. No difference was observed in the quality of the preparation between the two preparation methods. CONCLUSIONS: The following conclusions can be made: polyethylene glycol solution had higher tolerability, acceptability, and safety than the mannitol and should be used instead of mannitol. Both preparation solutions have similar efficacy.<\/jats:p>","DOI":"10.1590\/s0004-28032012000200012","type":"journal-article","created":{"date-parts":[[2012,7,4]],"date-time":"2012-07-04T18:47:21Z","timestamp":1341427641000},"page":"162-168","source":"Crossref","is-referenced-by-count":10,"title":["Bowel preparation for performing a colonoscopy: prospective randomized comparison study between a low-volume solution of polyethylene glycol and bisacodyl versus bisacodyl and a mannitol solution"],"prefix":"10.1590","volume":"49","author":[{"given":"Manoel Carlos","family":"Vieira","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claudio Lyoiti","family":"Hashimoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Flair Jos\u00e9","family":"Carrilho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"530","reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1007\/BF02555311","article-title":"Comparison of oral lavage methods for preoperative colonic cleansing","volume":"29","author":"Beck DE","year":"1986","journal-title":"Dis Colon Rectum","ISSN":"https:\/\/id.crossref.org\/issn\/0012-3706","issn-type":"print"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1111\/j.1365-2036.2006.03212.x","article-title":"Systematic review: oral bowel preparation for colonoscopy","volume":"25","author":"Belsey J","year":"2007","journal-title":"Aliment Pharmacol Ther","ISSN":"https:\/\/id.crossref.org\/issn\/0269-2813","issn-type":"print"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"1307","DOI":"10.1016\/0016-5085(79)90172-0","article-title":"Fatal colonic explosion during colonoscopic polypectomy","volume":"77","author":"Bigard MA","year":"1979","journal-title":"Gastroenterology","ISSN":"https:\/\/id.crossref.org\/issn\/0016-5085","issn-type":"print"},{"key":"ref4","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/S0016-5107(76)73579-X","article-title":"Explosion of hydrogen gas in the colon during proctosigmoidoscopy","volume":"23","author":"Bond JH","year":"1976","journal-title":"Gastrointest Endosc","ISSN":"https:\/\/id.crossref.org\/issn\/0016-5107","issn-type":"print"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/S0399-8320(05)80689-X","article-title":"A prospective national study on colonoscopy and sigmoidoscopy in 2000 in France","volume":"29","author":"Canard JM","year":"2005","journal-title":"Gastroenterol Clin Biol","ISSN":"https:\/\/id.crossref.org\/issn\/0399-8320","issn-type":"print"},{"key":"ref6","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1111\/j.1365-2036.2007.03459.x","article-title":"Clinical trial: an efficacy evaluation of reduced bisacodyl given as part of a polyethyleneglycol electrolyte solution preparation prior to colonoscopy","volume":"26","author":"DiPalma JA","year":"2007","journal-title":"Aliment Pharmacol Ther","ISSN":"https:\/\/id.crossref.org\/issn\/0269-2813","issn-type":"print"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1016\/S0016-5107(04)02776-2","article-title":"Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European Panel of appropriateness of Gastrointestinal Endoscopy European multicenter study","volume":"61","author":"Froehlich F","year":"2005","journal-title":"Gastrointest Endosc","ISSN":"https:\/\/id.crossref.org\/issn\/0016-5107","issn-type":"print"},{"key":"ref8","first-page":"127","article-title":"Preparation of the colon for colonoscopy: A prospective study with a 10% mannitol solution and with an electrolyte solution containing polyethylene glycol","volume":"5","author":"Habr-Gama A","year":"1986","journal-title":"GED Gastroenterol Endosc Dig"},{"key":"ref9","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1067\/mge.2003.294","article-title":"Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia","volume":"58","author":"Harewood GC","year":"2003","journal-title":"Gastrointest Endosc","ISSN":"https:\/\/id.crossref.org\/issn\/0016-5107","issn-type":"print"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1111\/j.1463-1318.2007.01220.x","article-title":"The impact of poor bowel preparation on colonoscopy: a propective single centre study of 10,571 colonoscopies","volume":"9","author":"Hendry PO","year":"2007","journal-title":"Colorectal Dis"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"5295","DOI":"10.3748\/wjg.v13.i40.5295","article-title":"Colonic gas explosion during therapeutic colonoscopy with electrocautery","volume":"13","author":"Ladas SD","year":"2007","journal-title":"World J Gastroenterol"},{"key":"ref12","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1016\/j.gie.2008.05.057","article-title":"The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research","volume":"69","author":"Lai EJ","year":"2009","journal-title":"Gastrointest Endosc","ISSN":"https:\/\/id.crossref.org\/issn\/0016-5107","issn-type":"print"},{"key":"ref13","doi-asserted-by":"crossref","first-page":"1361","DOI":"10.1111\/j.1365-2036.2007.03496.x","article-title":"Clinical trial: odium phosphate tablets are preferred and better tolerated by patients compared to polyethylene glycol solution plus bisacodyl tablets for bowel preparation","volume":"26","author":"Lichtenstein GR","year":"2007","journal-title":"Aliment Pharmacol Ther","ISSN":"https:\/\/id.crossref.org\/issn\/0269-2813","issn-type":"print"},{"key":"ref14","first-page":"34","article-title":"Successful colonoscopy: completion rates and reasons for incompletion","volume":"71","author":"Mitchell RM","year":"2002","journal-title":"Ulster Med. J"},{"key":"ref15","first-page":"294","article-title":"Comparative evaluation of bowel preparation for colonoscopy using mannitol and polyethylene glycol: a prospective study","volume":"28","author":"Nunes BL","year":"2008","journal-title":"Rev Bras Coloproctol"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1016\/S0016-5107(03)02875-X","article-title":"Validation of a new scale for the assessment of bowel preparation quality","volume":"59","author":"Rostom A","year":"2004","journal-title":"Gastrointest Endosc","ISSN":"https:\/\/id.crossref.org\/issn\/0016-5107","issn-type":"print"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"2224","DOI":"10.1111\/j.1572-0241.2008.02053.x","article-title":"Single-dose lubiprostone along split-dose PEG solution without dietary restrictions for bowel cleansing prior to colonoscopy: a randomized, double-blind, placebo-controlled trial","volume":"103","author":"Stengel JZ","year":"2008","journal-title":"Am J Gastroenterol","ISSN":"https:\/\/id.crossref.org\/issn\/0002-9270","issn-type":"print"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"894","DOI":"10.1016\/j.gie.2006.03.918","article-title":"A consensus document on bowel preparation before colonoscopy: prepared by a Task Force From The American Society of Colon and Rectal Surgeons (ASCRS), the American Society for Gastrointestinal Endoscopy (ASGE), and the Society of American Gastrointestinal and Endoscopic Surgeons (SAGES)","volume":"63","author":"Wexner SD","year":"2006","journal-title":"Gastrointest Endosc","ISSN":"https:\/\/id.crossref.org\/issn\/0016-5107","issn-type":"print"}],"container-title":["Arquivos de Gastroenterologia"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/pdf\/ag\/v49n2\/12.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,30]],"date-time":"2019-06-30T10:32:51Z","timestamp":1561890771000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S0004-28032012000200012&lng=en&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,6]]},"references-count":18,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2012,6]]}},"alternative-id":["S0004-28032012000200012"],"URL":"https:\/\/doi.org\/10.1590\/s0004-28032012000200012","relation":{},"ISSN":["0004-2803"],"issn-type":[{"value":"0004-2803","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,6]]}}}