{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T14:24:55Z","timestamp":1790000695015,"version":"4.0.1"},"reference-count":16,"publisher":"FapUNIFESP (SciELO)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Arq. Neuro-Psiquiatr."],"published-print":{"date-parts":[[1989,9]]},"abstract":"<jats:p>The authors studied the availability of parenteral solutions of diazepam in glass bottles or polyethylene (PE) containers during infusion through polyvinyl chloride (PVC) administration sets. Diazepam solutions in concentration of 10O0mg\/5OOml in 0.9% sodium chloride (NS) and 5% glucose (G5W) injection were infused at a flow rate of 30ml\/h, and samples were taken from the bottle and at the end of the administration set, till 12 hours of infusion. The samples were tested in triplicate using ultraviolet spectrophotometry. The greatest loss of diazepam was observed in all solutions at 30 minutes of infusion (63.5% G5W glass, 60.5% NS glass, 55% G5W PE and 58% NS PE from the original concentration of 200 ug\/ml). The diazepam concentrations in the containers did not significantly changed. The loss of diazepam from solutions infused through PVC administration sets should be kept in mind in severe clinical situations as status epilepticus, tetanus and eclampsia.<\/jats:p>","DOI":"10.1590\/s0004-282x1989000300007","type":"journal-article","created":{"date-parts":[[2017,3,29]],"date-time":"2017-03-29T18:54:53Z","timestamp":1490813693000},"page":"291-294","source":"Crossref","is-referenced-by-count":6,"title":["Factors affecting diazepam availability from intravenous admixture solutions"],"prefix":"10.1590","volume":"47","author":[{"given":"Walter Oleschko","family":"Arruda","sequence":"first","affiliation":[{"name":"Universidade Federal do Paran\u00e1; Instituto M\u00e9dico Legal do Paran\u00e1"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dilermando","family":"Brito Filho","sequence":"additional","affiliation":[{"name":"Universidade Federal do Paran\u00e1; Instituto M\u00e9dico Legal do Paran\u00e1"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Solange L. C.","family":"Rosa","sequence":"additional","affiliation":[{"name":"Universidade Federal do Paran\u00e1; Instituto M\u00e9dico Legal do Paran\u00e1"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paulo S. G.","family":"Fontoura","sequence":"additional","affiliation":[{"name":"Universidade Federal do Paran\u00e1; Instituto M\u00e9dico Legal do Paran\u00e1"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Moema De Ara\u00fajo","family":"Cardoso","sequence":"additional","affiliation":[{"name":"Universidade Federal do Paran\u00e1; Instituto M\u00e9dico Legal do Paran\u00e1"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"530","reference":[{"key":"ref1","first-page":"357","article-title":"Estado de mal epil\u00e9ptico","volume":"94","author":"Arruda WO","year":"1987","journal-title":"Folha M\u00e9dica"},{"key":"ref2","first-page":"1209","article-title":"Active management of severe pre-eclampsia","volume":"109","author":"Baskett TF","year":"1973","journal-title":"Can Med Assoc J","ISSN":"https:\/\/id.crossref.org\/issn\/0008-4409","issn-type":"print"},{"key":"ref3","series-title":"Trataiuento de T\u00e9tano Grave","author":"Clausa RM","year":"1981"},{"key":"ref4","first-page":"492","article-title":"Availability of diazepam from plastic containers","volume":"37","author":"Cloyd JC","year":"1980","journal-title":"Am J Hosp Pharm","ISSN":"https:\/\/id.crossref.org\/issn\/0002-9289","issn-type":"print"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1093\/bja\/42.3.217","article-title":"The benzodiazepines: a review of their actions and uses relative to anaesthetic practice","volume":"42","author":"Dundee JW","year":"1970","journal-title":"Br J Anaesth","ISSN":"https:\/\/id.crossref.org\/issn\/0007-0912","issn-type":"print"},{"key":"ref6","first-page":"335","article-title":"Effect of a polyethylene-lined administration set on the availability of diazepam injection","volume":"42","author":"Hancock EG","year":"1985","journal-title":"Am J Hosp Pharm","ISSN":"https:\/\/id.crossref.org\/issn\/0002-9289","issn-type":"print"},{"key":"ref7","first-page":"1308","article-title":"Interactions between drugs and polyvinyl chloride infusion bags","volume":"38","author":"Kowaluk EA","journal-title":"Am J Hosp Pharm","ISSN":"https:\/\/id.crossref.org\/issn\/0002-9289","issn-type":"print"},{"key":"ref8","first-page":"460","article-title":"Interactions between drugs and intravenous delivery systems","volume":"39","author":"Kowaluk EA","year":"1982","journal-title":"Am J Hosp Pharm","ISSN":"https:\/\/id.crossref.org\/issn\/0002-9289","issn-type":"print"},{"key":"ref9","first-page":"417","article-title":"Factors affecting the availability of diazepam stored in plastic bags and administered through intravenous sets","volume":"40","author":"Kowaluk EA","year":"1983","journal-title":"Am J Hosp Pharm","ISSN":"https:\/\/id.crossref.org\/issn\/0002-9289","issn-type":"print"},{"key":"ref10","first-page":"83","article-title":"Pluronic surfactants affecting diazepam solubility, compatibility and adsorption from i.v. admixture solutions","volume":"41","author":"Lin S-Y","year":"1987","journal-title":"J Parent Sci Technol"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1056\/NEJM197908093010620","article-title":"Adsorption of diazepam to plastic tubing","volume":"301","author":"MacKichan J","year":"1979","journal-title":"N Engl J Med","ISSN":"https:\/\/id.crossref.org\/issn\/0028-4793","issn-type":"print"},{"key":"ref12","first-page":"1449","article-title":"I actors affecting diazepam infusion: solubility, administration-set composition and flow-rate","volume":"38","author":"Mason NA","year":"1981","journal-title":"Am J Hosp Pharm","ISSN":"https:\/\/id.crossref.org\/issn\/0002-9289","issn-type":"print"},{"key":"ref13","first-page":"505","article-title":"Incompatibility of diazepam injection in plastic intravenous bags","volume":"36","author":"Parker WA","year":"1979","journal-title":"Am J Hosp Pharm","ISSN":"https:\/\/id.crossref.org\/issn\/0002-9289","issn-type":"print"},{"key":"ref14","first-page":"496","article-title":"Compatibility of diazepam with intravenous fluid containers and administration sets","volume":"37","author":"Parker WA","year":"1980","journal-title":"Am J Hosp Pharm","ISSN":"https:\/\/id.crossref.org\/issn\/0002-9289","issn-type":"print"},{"key":"ref15","first-page":"1018","article-title":"Sorptive loss of diazepam and nitroglycerin from solutions to three types of containers","volume":"39","author":"Yliruusi JK","year":"1982","journal-title":"Am J Hosp Pharm","ISSN":"https:\/\/id.crossref.org\/issn\/0002-9289","issn-type":"print"},{"key":"ref16","first-page":"2795","article-title":"Effect of flow rate and type of i: v. container on adsorption of diazepam to i.v. administration systems","volume":"43","author":"Yliruusi JK","year":"1986","journal-title":"Am J Hsop Pharm"}],"container-title":["Arquivos de Neuro-Psiquiatria"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/pdf\/anp\/v47n3\/07.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,5,26]],"date-time":"2017-05-26T22:10:40Z","timestamp":1495836640000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S0004-282X1989000300007&lng=en&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1989,9]]},"references-count":16,"journal-issue":{"issue":"3","published-print":{"date-parts":[[1989,9]]}},"alternative-id":["S0004-282X1989000300007"],"URL":"https:\/\/doi.org\/10.1590\/s0004-282x1989000300007","relation":{},"ISSN":["0004-282X"],"issn-type":[{"value":"0004-282X","type":"electronic"}],"subject":[],"published":{"date-parts":[[1989,9]]}}}