{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,1,24]],"date-time":"2024-01-24T23:38:04Z","timestamp":1706139484498},"reference-count":16,"publisher":"FapUNIFESP (SciELO)","issue":"2A","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Arq. Neuro-Psiquiatr."],"published-print":{"date-parts":[[1999,6]]},"abstract":"<jats:p>Electrodiagnosis of carpal tunnel syndrome (CTS) were prospectively studied in 95 hands. The following techniques were studied in all hands and when at least one abnormal value was found (onset-measured), it was included on results: 1. wrist-index finger latency (WIF), abnormal &gt; or = 2.8 ms, 140 mm; 2. palm-wrist latency (PW), abnormal &gt; or = 1.8 ms, 80 mm; 3. comparison median\/ulnar palm-wrist latency (CPW), abnormal &gt; or = 0.4 ms; 4. comparison median\/ulnar latency, wrist-ring finger (CMU), abnormal &gt; or = 0.5 ms, 140 mm; 5. comparison median\/radial latency, wrist-thumb (CMR), abnormal &gt; or = 0.4 ms, 100 mm. All 95 CTS hands selected have the WIF &lt;= 3.5 ms (mild CTS). We found the CMR (97.8%) technique the most sensitive for mild CTS electrodiagnosis and the only comparative method with all potentials recordable when compared to CPW (88.4%), PW (84.2%), CMU (72.6%) and WIF (68.4%).<\/jats:p>","DOI":"10.1590\/s0004-282x1999000200005","type":"journal-article","created":{"date-parts":[[2005,4,15]],"date-time":"2005-04-15T14:24:16Z","timestamp":1113575056000},"page":"195-197","source":"Crossref","is-referenced-by-count":3,"title":["Comparison of nerve conduction techniques in 95 mild carpal tunnel syndrome hands"],"prefix":"10.1590","volume":"57","author":[{"given":"JOAO ARIS","family":"KOUYOUMDJIAN","sequence":"first","affiliation":[{"name":"Faculty of Medicine, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"MARIA DA PENHA ANANIAS","family":"MORITA","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"530","reference":[{"key":"ref1","author":"Andary MT","year":"1997"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"1392","DOI":"10.1002\/mus.880161220","article-title":"Literature review of the usefulness of nerve conduction studies and electromyography for the evaluation of patients with carpal tunnel syndrome","volume":"16","author":"Jablecki CK","year":"1993","journal-title":"Muscle Nerve","ISSN":"http:\/\/id.crossref.org\/issn\/0148-639X","issn-type":"print"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/S0003-9993(21)01687-7","article-title":"Electrodiagnosis of mild carpal tunnel syndrome","volume":"70","author":"Jackson D","year":"1989","journal-title":"Arch Phys Med Rehabil","ISSN":"http:\/\/id.crossref.org\/issn\/0003-9993","issn-type":"print"},{"key":"ref4","doi-asserted-by":"crossref","first-page":"1177","DOI":"10.1002\/mus.880111112","article-title":"A comparison of EMG procedures in the carpal tunnel syndrome with clinical-EMG correlations","volume":"11","author":"White JC","year":"1988","journal-title":"Muscle Nerve","ISSN":"http:\/\/id.crossref.org\/issn\/0148-639X","issn-type":"print"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/0168-5597(87)90037-2","article-title":"Comparison of the median and radial sensory latencies in the electrophysiological diagnosis of carpal tunnel syndrome","volume":"68","author":"Carrol G","year":"1987","journal-title":"Electroencephalogr Clin Neurophysiol","ISSN":"http:\/\/id.crossref.org\/issn\/0013-4694","issn-type":"print"},{"key":"ref6","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1002\/mus.880121106","article-title":"Median to radial latency difference test in mild carpal tunnel syndrome","volume":"12","author":"Pease WS","year":"1989","journal-title":"Muscle Nerve","ISSN":"http:\/\/id.crossref.org\/issn\/0148-639X","issn-type":"print"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1007\/BF00314501","article-title":"Diagnostic specificity of sensory and motor nerve conduction variables in early detection of carpal tunnel syndrome","volume":"236","author":"Cioni R","year":"1989","journal-title":"J Neurol","ISSN":"http:\/\/id.crossref.org\/issn\/0340-5354","issn-type":"print"},{"key":"ref8","first-page":"279","article-title":"Comparison of sensory mid-palm studies to other techniques in carpal tunnel syndrome","volume":"36","author":"Andary MT","year":"1996","journal-title":"Electromyogr Clin Neurophysiol","ISSN":"http:\/\/id.crossref.org\/issn\/0301-150X","issn-type":"print"},{"key":"ref9","first-page":"140","article-title":"Median and radial sensory latencies to digit I: normal values and usefulness in carpal tunnel syndrome","volume":"68","author":"Johnson EW","year":"1987","journal-title":"Arch Phys Med Rehabil","ISSN":"http:\/\/id.crossref.org\/issn\/0003-9993","issn-type":"print"},{"key":"ref10","first-page":"59","article-title":"Palmar digital stimulation to diagnose carpal tunnel syndrome","volume":"6","author":"Kim LYS","year":"1983","journal-title":"Orthop Rev","ISSN":"http:\/\/id.crossref.org\/issn\/0094-6591","issn-type":"print"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1136\/jnnp.48.3.250","article-title":"Orthodromic sensory action potentials from palmar stimulation in the diagnosis of carpal tunnel syndrome","volume":"48","author":"Mills KR","year":"1985","journal-title":"J Neurol Neurosurg Psychiatry","ISSN":"http:\/\/id.crossref.org\/issn\/0022-3050","issn-type":"print"},{"key":"ref12","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1002\/mus.880120906","article-title":"Ring finger testing in carpal tunnel syndrome: a comparative study of diagnostic utility","volume":"12","author":"Uncini A","year":"1989","journal-title":"Muscle Nerve","ISSN":"http:\/\/id.crossref.org\/issn\/0148-639X","issn-type":"print"},{"key":"ref13","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/0168-5597(91)90099-J","article-title":"Orthodromic sensory conduction along the ring finger in normal subjects and in patients with a carpal tunnel syndrome","volume":"81","author":"Lauritzen M","year":"1991","journal-title":"Electroencephalogr Clin Neurophysiol","ISSN":"http:\/\/id.crossref.org\/issn\/0013-4694","issn-type":"print"},{"key":"ref14","first-page":"123","article-title":"Carpal tunnel syndrome measurement of sensory potentials using ring and index fingers","volume":"61","author":"Monga TN","year":"1982","journal-title":"Am J Phys Med","ISSN":"http:\/\/id.crossref.org\/issn\/0002-9491","issn-type":"print"},{"key":"ref15","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/0013-4694(90)90212-3","article-title":"Clinical validation of antidromic stimulation of the ring finger in early electrodiagnosis of mild carpal tunnel syndrome","volume":"76","author":"Charles N","year":"1990","journal-title":"Electroencephalogr Clin Neurophysiol","ISSN":"http:\/\/id.crossref.org\/issn\/0013-4694","issn-type":"print"},{"key":"ref16","first-page":"206","article-title":"Sensory latencies to the ring finger: normal values and relation to carpal tunnel syndrome","volume":"62","author":"Johnson EW","year":"1981","journal-title":"Arch Phys Med Rehabil","ISSN":"http:\/\/id.crossref.org\/issn\/0003-9993","issn-type":"print"}],"container-title":["Arquivos de Neuro-Psiquiatria"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/pdf\/anp\/v57n2a\/1468.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,24]],"date-time":"2024-01-24T22:55:46Z","timestamp":1706136946000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S0004-282X1999000200005&lng=en&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1999,6]]},"references-count":16,"journal-issue":{"issue":"2A","published-print":{"date-parts":[[1999,6]]}},"alternative-id":["S0004-282X1999000200005"],"URL":"https:\/\/doi.org\/10.1590\/s0004-282x1999000200005","relation":{},"ISSN":["0004-282X"],"issn-type":[{"value":"0004-282X","type":"electronic"}],"subject":[],"published":{"date-parts":[[1999,6]]}}}