{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T03:18:44Z","timestamp":1787023124718,"version":"build-2736575974"},"reference-count":17,"publisher":"FapUNIFESP (SciELO)","issue":"2a","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Arq. Neuro-Psiquiatr."],"published-print":{"date-parts":[[2005,6]]},"abstract":"<jats:p>Occlusion or stenosis of a parent vessel or its distal branches is a major cause of poor patient outcome after cerebral aneurysm surgery. Despite great attempts to preserve patency at the time of clip application, intraoperative visual observation may not reveal arterial compromise or occlusion. Quantitative measurement of blood flow in cerebral vessels during aneurysm surgery can help prevent ischaemia and improve patient outcome. We report a case of a large complex middle cerebral artery (MCA) aneurysm in which perivascular microflow probes were used to measure blood flow quantitatively in MCA and its branches before and after aneurysm clipping. Following aneurysm clipping, blood flow in the MCA branches were significantly reduced to less than its initial baseline value with occlusion of the inferior M2 segment. Prompt detection of compromised blood flow gave the surgeon the opportunity to adjust the clip. This adjustment was performed several times until restore MCA flow to its preclipping values. Intraoperative quantitative vessel-flow measurements were safe and may have prevented cerebral ischaemia and neurological deficit to this patient.<\/jats:p>","DOI":"10.1590\/s0004-282x2005000200028","type":"journal-article","created":{"date-parts":[[2006,1,9]],"date-time":"2006-01-09T13:48:56Z","timestamp":1136814536000},"page":"339-344","source":"Crossref","is-referenced-by-count":13,"title":["Clip readjustment in aneurysm surgery after flow evaluation using the ultrasonic perivascular probe: case report"],"prefix":"10.1590","volume":"63","author":[{"given":"Walter J.","family":"Fagundes-Pereyra","sequence":"first","affiliation":[{"name":"University of Illinois at Chicago,  USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William E.","family":"Hoffman","sequence":"additional","affiliation":[{"name":"University of Illinois at Chicago,  USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mukesh","family":"Misra","sequence":"additional","affiliation":[{"name":"University of Illinois at Chicago,  USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fady T.","family":"Charbel","sequence":"additional","affiliation":[{"name":"University of Illinois at Chicago,  USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"530","reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1097\/00006123-199705000-00018","article-title":"Intraoperative microvascular Doppler sonography in aneurysm surgery","volume":"40","author":"Bailes JE","year":"1997","journal-title":"Neurosurgery","ISSN":"https:\/\/id.crossref.org\/issn\/0148-396X","issn-type":"print"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.3171\/jns.1999.91.6.1050","article-title":"Quantitative assessment of vessel flow integrity for aneurysm surgery","volume":"91","author":"Charbel FT","year":"1999","journal-title":"J Neurosurg","ISSN":"https:\/\/id.crossref.org\/issn\/0022-3085","issn-type":"print"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"S35","DOI":"10.2176\/nmc.38.suppl_35","article-title":"Role of a perivascular ultrasonic micro-flow probe in aneurysm surgery","author":"Charbel FT","year":"1998","journal-title":"Neurol Med Chir","ISSN":"https:\/\/id.crossref.org\/issn\/0470-8105","issn-type":"print"},{"key":"ref4","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1136\/jnnp.68.1.29","article-title":"Intraoperative microvascular Doppler ultrsonography in cerebral aneurysm","volume":"68","author":"Stendel R","year":"2000","journal-title":"J Neurol Neurosurg Psychiatry","ISSN":"https:\/\/id.crossref.org\/issn\/0022-3050","issn-type":"print"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"826","DOI":"10.3171\/jns.1993.79.6.0826","article-title":"Role of angiography following aneurysm surgery","volume":"79","author":"Macdonald RL","year":"1993","journal-title":"J Neurosurg","ISSN":"https:\/\/id.crossref.org\/issn\/0022-3085","issn-type":"print"},{"key":"ref6","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/S0090-3019(97)00529-6","article-title":"Optimal clip application and intraoperative angiography for intensive care aneurysms","volume":"51","author":"Origitano TC","year":"1999","journal-title":"Surg Neurol","ISSN":"https:\/\/id.crossref.org\/issn\/0090-3019","issn-type":"print"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"441","DOI":"10.3171\/jns.1998.88.3.0441","article-title":"Role of intraoperative angiography in the surgical treatment of cerebral aneurysms","volume":"88","author":"Payner TD","year":"1998","journal-title":"J Neurosurg","ISSN":"https:\/\/id.crossref.org\/issn\/0022-3085","issn-type":"print"},{"key":"ref8","doi-asserted-by":"crossref","first-page":"526","DOI":"10.3171\/jns.1990.73.4.0526","article-title":"Intraoperative digital subtraction angiography and the surgical treatment of intracranial aneurysms and vascular malformations","volume":"73","author":"Martin NA","year":"1990","journal-title":"J Neurosurg","ISSN":"https:\/\/id.crossref.org\/issn\/0022-3085","issn-type":"print"},{"key":"ref9","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1227\/00006123-199202000-00001","article-title":"Intraoperative angiography in the management of neurovascular disorders","volume":"30","author":"Barrow DL","year":"1992","journal-title":"Neurosurgery","ISSN":"https:\/\/id.crossref.org\/issn\/0148-396X","issn-type":"print"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1097\/00006123-199607000-00004","article-title":"Intraoperative angiography in cerebral aneurysm surgery: a prospective study of 100 craniotomies","volume":"39","author":"Alexander TD","year":"1996","journal-title":"Neurosurgery","ISSN":"https:\/\/id.crossref.org\/issn\/0148-396X","issn-type":"print"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1148\/radiology.205.2.9356612","article-title":"Intracranial aneurysm: anatomic factors that predict the usefulness of intraoperative angiography","volume":"205","author":"Derdeyn CP","year":"1997","journal-title":"Radiology","ISSN":"https:\/\/id.crossref.org\/issn\/0033-8419","issn-type":"print"},{"key":"ref12","first-page":"H1368","article-title":"Validation of 1- and 2-mm transit time ultrasound flow probes on mesenteric artery and aorta of rats","volume":"268","author":"D' Almeida MS","year":"1995","journal-title":"Am J Physiol","ISSN":"https:\/\/id.crossref.org\/issn\/0002-9513","issn-type":"print"},{"key":"ref13","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/1056-8719(94)90078-7","article-title":"In vivo validation of a transit-time ultrasonic volume flow meter","volume":"31","author":"Hartman JC","year":"1994","journal-title":"J Pharmacol Toxicol Methods","ISSN":"https:\/\/id.crossref.org\/issn\/1056-8719","issn-type":"print"},{"key":"ref14","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1111\/j.1475-097X.1993.tb00470.x","article-title":"Volume blood flow measurements with a transit time flowmeter: an in vivo and in vitro variability and validation study","volume":"13","author":"Lundell A","year":"1993","journal-title":"Clin Physiol","ISSN":"https:\/\/id.crossref.org\/issn\/0144-5979","issn-type":"print"},{"key":"ref15","first-page":"FI75","article-title":"Validation of miniature ultrasonic transit-time flow probes for measurement of renal blood flow in rats","volume":"268","author":"Welch WJ","year":"1995","journal-title":"Am J Physiol","ISSN":"https:\/\/id.crossref.org\/issn\/0002-9513","issn-type":"print"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1097\/00005344-199604000-00005","article-title":"Validation of transonic small animal flowmeter for measurement of cardiac output and regional blood flow in the rat","volume":"4","author":"Wen C","year":"1996","journal-title":"J Cardiovasc Pharmacol","ISSN":"https:\/\/id.crossref.org\/issn\/0160-2446","issn-type":"print"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s007010170133","article-title":"Intraoperative measurement of arterial blood flow using a transit time flowmeter: monitoring of hemodynamic changes during cerebrovascular surgery","volume":"143","author":"Nakayama N","year":"2001","journal-title":"Acta Neurochir","ISSN":"https:\/\/id.crossref.org\/issn\/0001-6268","issn-type":"print"}],"container-title":["Arquivos de Neuro-Psiquiatria"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/pdf\/anp\/v63n2a\/a28v632a.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,5,25]],"date-time":"2017-05-25T03:37:49Z","timestamp":1495683469000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S0004-282X2005000200028&lng=en&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,6]]},"references-count":17,"journal-issue":{"issue":"2a","published-print":{"date-parts":[[2005,6]]}},"alternative-id":["S0004-282X2005000200028"],"URL":"https:\/\/doi.org\/10.1590\/s0004-282x2005000200028","relation":{},"ISSN":["0004-282X"],"issn-type":[{"value":"0004-282X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,6]]}}}