{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,13]],"date-time":"2023-09-13T19:21:01Z","timestamp":1694632861728},"reference-count":20,"publisher":"FapUNIFESP (SciELO)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Cir. Bras."],"published-print":{"date-parts":[[2008,6]]},"abstract":"<jats:p>PURPOSE: Evaluate by CT the use of porous vitreous carbon (PVC) and silicon (S) implants as the replacement bone in the craniofacial skeleton of rats. METHODS: 40 rats divided in: Group A (n=20) PVC submitted to the implant of a fragment in skull. After the euthanasia, the animals were divided into two subgroups: A I: 10 animals, studied in the 7th postoperative day (P.O) and AII: 10 animals, studied in the 28th P.O. In group B, S, 20 rats were submitted to S implant in the skull. All other steps were identical to group A, with designation of subgroups BI and BII. CT with beams in axial cuts of 1 mm thickness to obtain 3-D information It was used Hounsfield scale for evaluate the radio density of the implant. They were used non parametric tests to analyze the results. RESULTS: The 7th PO boss remained in the two groups, but for 28th PO, observed reduction in the volume of the implant in Group A, not observed in group B. CT studies noticed different radio densities around all of S prostheses (pseudo-capsule), that don't appeared in CPV implants. The S has remained unchanged in the CT, but the CPV has had a modification in its radio density (p&lt;0,05), in all implants. CONCLUSION: In CT evaluation the implants of CPV have greater deformation that the S, which makes them not suitable for replacement of membranous bone in the rat skull.<\/jats:p>","DOI":"10.1590\/s0102-86502008000300013","type":"journal-article","created":{"date-parts":[[2008,6,12]],"date-time":"2008-06-12T04:13:03Z","timestamp":1213243983000},"page":"287-293","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of porous vitreous carbon or silicon implants by radiology in rat's skull"],"prefix":"10.1590","volume":"23","author":[{"given":"Marcelo Paulo","family":"Vaccari-Mazzetti","sequence":"first","affiliation":[{"name":"Lus\u00edada University of Santos, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dulce Maria Fonseca Soares","family":"Martins","sequence":"additional","affiliation":[{"name":"UNIFESP, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paulo de Oliveira","family":"Gomes","sequence":"additional","affiliation":[{"name":"UNIFESP, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jos\u00e9 Luiz","family":"Martins","sequence":"additional","affiliation":[{"name":"UNIFESP, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paulo","family":"Fabiani","sequence":"additional","affiliation":[{"name":"Lus\u00edada University of Santos, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C\u00e9lio Toshiro","family":"Kobata","sequence":"additional","affiliation":[{"name":"Hospital Defeitos da Face, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"530","reference":[{"key":"ref1","series-title":"Cirurgia Pl\u00e1stica","first-page":"211","volume-title":"Embriologia e crescimento da face","author":"Vaccari-Mazzetti MP","year":"2005"},{"issue":"4","key":"ref2","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1016\/S0094-1298(20)30721-5","article-title":"Bone grafts and bone induction substitutes","volume":"21","author":"Habal MB","year":"1994","journal-title":"Clin Plast Surg","ISSN":"http:\/\/id.crossref.org\/issn\/0094-1298","issn-type":"print"},{"key":"ref3","first-page":"96","article-title":"S\u00edndrome de Goldenhar","volume":"32","author":"Vaccari-Mazzetti MP","journal-title":"Arq Cat Med. 2003"},{"issue":"3","key":"ref4","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1088\/0143-0815\/1\/3\/401","article-title":"Biomedical applications of carbons and graphite's","volume":"1","author":"Jenkins GM","year":"1980","journal-title":"Clin Phys Physiol Meas","ISSN":"http:\/\/id.crossref.org\/issn\/0143-0815","issn-type":"print"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1097\/00006534-196504000-00002","article-title":"The silicon in plastic surgery","volume":"35","author":"Blocksma R","year":"1965","journal-title":"Plast Reconstr Surg","ISSN":"http:\/\/id.crossref.org\/issn\/0032-1052","issn-type":"print"},{"key":"ref6","series-title":"O uso do implante de carbono na corre\u00e7\u00e3o cir\u00fargica do nariz em sela","author":"Patroc\u00ednio JA","year":"1985"},{"issue":"1","key":"ref7","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1097\/01.scs.0000193553.39917.eb","article-title":"The use of silicon elastomer in maxilofacial rehabilitation as a substitute for or in conjunction with resins","volume":"17","author":"Mortellaro C","year":"2006","journal-title":"J Craniofac Surg","ISSN":"http:\/\/id.crossref.org\/issn\/1049-2275","issn-type":"print"},{"key":"ref8","first-page":"48","article-title":"Type uukm-4d carbonic carbon and porous titanium in plastic repair in bone defects: experimental studies","volume":"3","author":"Iakimemko DV","year":"1999","journal-title":"Probl Tuberk","ISSN":"http:\/\/id.crossref.org\/issn\/0032-9533","issn-type":"print"},{"key":"ref9","series-title":"Using ct and implant to plan implant therapy","author":"Branemark PI","year":"2001"},{"key":"ref10","series-title":"Nonparametric statistics","author":"Siegel S","year":"1988"},{"issue":"3","key":"ref11","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1590\/S0102-86501997000300009","article-title":"Estudo comparativo das rea\u00e7\u00f5es teciduais \u00e0 implanta\u00e7\u00e3o de silicone e politetrafluoretileno no dorso de ratos","volume":"12","author":"Kafejian AP","year":"1997","journal-title":"Acta Cir Bras"},{"key":"ref12","series-title":"National Clearinghouse of Plastic Statistics","year":"2005"},{"issue":"2","key":"ref13","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1097\/00006534-197602000-00002","article-title":"Retrospective cephalometric analysis of mandibular bone absorption under silicon rubber chins implants","volume":"57","author":"Friedland JA","year":"1976","journal-title":"Plast Reconstr Surg","ISSN":"http:\/\/id.crossref.org\/issn\/0032-1052","issn-type":"print"},{"key":"ref14","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1046\/j.1365-2273.2002.00546.x","article-title":"Bone resorption after alloplastic augmentation of the mandible","volume":"27","author":"Saleh HA","year":"2002","journal-title":"Clin Otolaryngol","ISSN":"http:\/\/id.crossref.org\/issn\/0307-7772","issn-type":"print"},{"issue":"4","key":"ref15","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1177\/096368979400300411","article-title":"Pore morphology effects in the fibrovascular tissue growth in porous polymer substrates","volume":"3","author":"Wake MC","year":"1994","journal-title":"Cell Transplant","ISSN":"http:\/\/id.crossref.org\/issn\/0963-6897","issn-type":"print"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1002\/(SICI)1097-4636(1999)48:3<289::AID-JBM12>3.0.CO;2-L","article-title":"Interaction between carbon composites and bone after intrabone implantation","volume":"48","author":"Lewandowska -Szumiel M","year":"1999","journal-title":"J Biomed Mater Res","ISSN":"http:\/\/id.crossref.org\/issn\/0021-9304","issn-type":"print"},{"issue":"2","key":"ref17","first-page":"182","article-title":"Evaluation of a porous, biodegradable biopolymer scaffold for mandibular reconstruction","volume":"18","author":"Trantolo DJ","year":"2003","journal-title":"Int J Oral Maxillofac Implants","ISSN":"http:\/\/id.crossref.org\/issn\/0882-2786","issn-type":"print"},{"issue":"5","key":"ref18","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1001\/archotol.1990.01870050051005","article-title":"Comparison of biomaterials for facial bone augmentation","volume":"116","author":"Mass CS","year":"1990","journal-title":"Arch Otolaryngol Head Neck Surg","ISSN":"http:\/\/id.crossref.org\/issn\/0886-4470","issn-type":"print"},{"issue":"27","key":"ref19","doi-asserted-by":"crossref","first-page":"4671","DOI":"10.1016\/j.biomaterials.2006.04.041","article-title":"Experimental and clinical performance of porous tantalum in orthopedic surgery","volume":"27","author":"Levine BR","year":"2006","journal-title":"Biomaterials","ISSN":"http:\/\/id.crossref.org\/issn\/0142-9612","issn-type":"print"},{"issue":"1","key":"ref20","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1002\/jbm.b.30653","article-title":"Experimental lumbar spine fusion with novel tantalum-coated carbon fiber implant","volume":"81","author":"Li H","year":"2007","journal-title":"J Biomed Mater Res B Appl Biomater"}],"container-title":["Acta Cirurgica Brasileira"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/pdf\/acb\/v23n3\/13.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,12]],"date-time":"2021-09-12T02:29:20Z","timestamp":1631413760000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S0102-86502008000300013&lng=en&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,6]]},"references-count":20,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2008,6]]}},"alternative-id":["S0102-86502008000300013"],"URL":"https:\/\/doi.org\/10.1590\/s0102-86502008000300013","relation":{},"ISSN":["0102-8650"],"issn-type":[{"value":"0102-8650","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,6]]}}}