{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T23:27:24Z","timestamp":1792711644812,"version":"4.5.0"},"reference-count":14,"publisher":"FapUNIFESP (SciELO)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Cir. Bras."],"published-print":{"date-parts":[[2011,10]]},"abstract":"<jats:p>PURPOSE: To describe and evaluate a modified technique of blind orotraqueal intubation in rabbits, by supporting of previous cannulization of the esophagus. METHODS: Twelve New Zealand rabbits, weighing between 2,780 a 4,140 kg were anesthetized with xilazine (3mg\/Kg) and ketamine (20mg\/Kg). The animals were positioned in ventral decubitus with the head hyperextend. With one of the hands the anesthetist with the index and thumb fingers positioned in the labial fissures carry on the opening of animal oral cavity. The esophagus was previously cannulized with a tube # 3.5 (3.5mm ID), obstructing its lumen. The trachea lumen was intubated with a probe # 2.5 (2.5mm ID). The positioning of the probe was confirmed through the oscillatory movement of a gauze filament put at outside extremity of tube, resulting from the inspiratory and expiratory flow. RESULTS: The success index was of 100%. CONCLUSIONS: This technique is of easy execution, high success index, sparing the use of several devices for visualization of the larynx and glottis. No complications were observed. It also serves for short period training of human resources.<\/jats:p>","DOI":"10.1590\/s0102-86502011000500005","type":"journal-article","created":{"date-parts":[[2011,9,15]],"date-time":"2011-09-15T15:49:24Z","timestamp":1316101764000},"page":"352-356","source":"Crossref","is-referenced-by-count":8,"title":["Technique of blind tracheal intubation in rabbits (Oryctolagus cuniculi) supported by previous maneuver of esophageal cannulization"],"prefix":"10.1590","volume":"26","author":[{"given":"Suyiene Cordeiro","family":"Falc\u00e3o","sequence":"first","affiliation":[{"name":"Federal Rural University of Pernambuco,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J\u00falio Rodrigues","family":"Pereira Junior","sequence":"additional","affiliation":[{"name":"Federal Rural University of Pernambuco,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ant\u00f4nio Roberto de Barros","family":"Coelho","sequence":"additional","affiliation":[{"name":"UFPE,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"530","reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1258\/002367700780457554","article-title":"Rapid oral endotracheal intubation with a fibre-optic scope in rabbits: a simple and reliable technique","volume":"34","author":"Worthley SG","year":"2000","journal-title":"Lab Anim."},{"issue":"2","key":"ref2","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1016\/j.cvex.2010.01.010","article-title":"Endoscopic intubation of exotic companion mammals","volume":"13","author":"Johnson DH.","year":"2010","journal-title":"Vet Clin North Am Exot Anim Pract."},{"issue":"2","key":"ref3","first-page":"82","article-title":"Anestesia em coelhos","volume":"11","author":"Fonseca NM","year":"1996","journal-title":"Acta Cir Bras."},{"issue":"3","key":"ref4","first-page":"108","article-title":"Avalia\u00e7\u00e3o de um sistema circular de anestesia, em ventila\u00e7\u00e3o mec\u00e2nica com press\u00e3o positiva intermitente: Anestesia quantitativa em coelhos (Oryctolagus cuniculus)","volume":"11","author":"Lima CA de Paula","year":"1996","journal-title":"Acta Cir Bras."},{"issue":"3","key":"ref5","first-page":"166","article-title":"Successful management of rabbit anesthesia through the use of nasotracheal intubation","volume":"48","author":"De Valle JMS.","year":"2009","journal-title":"J Am Assoc Lab Anim Sci."},{"issue":"2","key":"ref6","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1590\/S0102-86502001000200006","article-title":"Modelo de anestesia em coelhos para procedimentos no t\u00f3rax","volume":"16","author":"Kallas E","year":"2001","journal-title":"Acta Cir Bras."},{"key":"ref7","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1007\/s00540-004-0254-4","article-title":"A rabbit model for evaliation of surgical anesthesia and analgesia: characterization and validation with isoflurane anesthesia and entanyl analgesia","volume":"18","author":"Hayashida M","year":"2004","journal-title":"J Anesth."},{"issue":"1","key":"ref8","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1590\/S0102-86502010000100024","article-title":"Anesthesic protocol for videolaparoscopic surgery in rabbits","volume":"25","author":"Balbinotto RP","year":"2010","journal-title":"Acta Cir Bras."},{"issue":"6","key":"ref9","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1292\/jvms.53.1081","article-title":"Use of laryngeal mask airway in small animals","volume":"53","author":"Fujita M","year":"1991","journal-title":"J Vet Med Sci."},{"key":"ref10","article-title":"A new airway device for small laboratory animals","author":"Imai A","journal-title":"Lab Anim."},{"issue":"3","key":"ref11","first-page":"32","article-title":"Teaching a new method of rabbit intubation","volume":"46","author":"Morgan TJ","year":"2007","journal-title":"J Am Assoc Lab Anim Sci."},{"issue":"4","key":"ref12","first-page":"249","article-title":"Esfor\u00e7o respirat\u00f3rio do coelho com diferentes sistemas de anestesia: T de Ayre, Bain-Spoerel e Fonseca-Goldenberg","volume":"49","author":"Fonseca NM","year":"1999","journal-title":"Rev Bras Anestesiol."},{"key":"ref13","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1111\/j.1467-2995.2005.00169.x","article-title":"Comparison between facemasck and laryngeal masck airway in rabbits during isoflurane anesthesia","volume":"32","author":"Bateman L","year":"2005","journal-title":"Vet Anaesth Analg"},{"issue":"4","key":"ref14","first-page":"22","article-title":"Endotracheal tubes versus laryngeal mask airway in rabbit inhalation anesthesia: ease of use and waste gas emissions","volume":"43","author":"Smith JC","year":"2004","journal-title":"J Am Assoc Lab Anim Sci."}],"container-title":["Acta Cirurgica Brasileira"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/pdf\/acb\/v26n5\/a05v26n5.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,5,26]],"date-time":"2017-05-26T19:53:45Z","timestamp":1495828425000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S0102-86502011000500005&lng=en&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,10]]},"references-count":14,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2011,10]]}},"alternative-id":["S0102-86502011000500005"],"URL":"https:\/\/doi.org\/10.1590\/s0102-86502011000500005","relation":{},"ISSN":["0102-8650"],"issn-type":[{"value":"0102-8650","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,10]]}}}