{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T23:02:53Z","timestamp":1794870173902,"version":"4.9.1"},"reference-count":25,"publisher":"FapUNIFESP (SciELO)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sao Paulo Med. J."],"published-print":{"date-parts":[[2002,7]]},"abstract":"<jats:p>CONTEXT: The interest in the results from comparisons between handsewing and stapling in colorectal anastomoses has been reflected in the progressive increase in the number of clinical trials. These studies, however, do not permit conclusions to be drawn, given the lack of statistical power of the samples analyzed. OBJECTIVE: To compare stapling and handsewing in colorectal anastomosis, testing the hypothesis that in colorectal anastomosis the technique of stapling is superior to that of handsewing. DESIGN: A systematic review of randomized controlled trials. SURVEY STRATEGY: Systematic revision of the literature and meta-analysis were used, without restrictions on language, dates or other considerations. The sources of information used were Embase, Lilacs, Medline, Cochrane Controlled Clinical Trials Database, and letters to authors and industrial producers of staples and thread. SELECTION CRITERIA: Studies were included in accordance with randomization criteria. The external validity of the studies was investigated via the characteristics of the participants, the interventions and the variables analyzed. An independent selection of clinical studies focusing on analysis of adult patients attended to on an elective basis was made by two reviewers. DATA COLLECTION AND ANALYSIS: The methodological quality of the studies was assessed by the same reviewers. In addition to the randomization criteria, the masking, treatment intention, losses and exclusions were also analyzed. The meta-analysis was performed using risk difference and weighted average difference, with their respective 95% confidence intervals. The variables studied were mortality, clinical and radiological anastomotic dehiscence, anastomotic stricture, hemorrhage, reoperation, wound infection, time taken to perform the anastomosis and hospital stay. RESULTS: Nine clinical trials were selected. After verifying that it was possible to perform one of the two techniques being compared, 1,233 patients were included, of whom 622 underwent stapling and 611 the handsewing technique. No statistical difference was found between the variables, except for stenosis, which was more frequent in stapling (p &lt; 0.05), and the time taken to perform the anastomosis, which was greater in handsewing (p &lt; 0.05). CONCLUSION: The evidence found was insufficient to demonstrate superiority of the stapling method over handsewing, independent of the level of colorectal anastomosis.<\/jats:p>","DOI":"10.1590\/s1516-31802002000500002","type":"journal-article","created":{"date-parts":[[2005,4,27]],"date-time":"2005-04-27T10:53:19Z","timestamp":1114599199000},"page":"132-136","source":"Crossref","is-referenced-by-count":75,"title":["Stapled versus handsewn methods for colorectal anastomosis surgery: a systematic review of randomized controlled trials"],"prefix":"10.1590","volume":"120","author":[{"given":"Suzana Ang\u00e9lica da Silva","family":"Lustosa","sequence":"first","affiliation":[{"name":"Centro Universit\u00e1rio Funda\u00e7\u00e3o Oswaldo Aranha,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Delcio","family":"Matos","sequence":"additional","affiliation":[{"name":"Universidade Federal de S\u00e3o Paulo,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u00c1lvaro Nagib","family":"Atallah","sequence":"additional","affiliation":[{"name":"Universidade Federal de S\u00e3o Paulo,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aldemar Araujo","family":"Castro","sequence":"additional","affiliation":[{"name":"Universidade Federal de S\u00e3o Paulo,  Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"530","reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/0002-9610(81)90027-1","article-title":"Randomized prospective evaluation of EEA stapler colorectal anastomoses","volume":"141","author":"Beart Jr RW","year":"1991","journal-title":"Am J Surg","ISSN":"https:\/\/id.crossref.org\/issn\/0002-9610","issn-type":"print"},{"issue":"5","key":"ref2","first-page":"326","article-title":"Technique of rectum anastomoses in rectum resection, a controlled study: instrumental suture versus hand suture","volume":"55","author":"Thiede A","year":"1984","journal-title":"Chirurg","ISSN":"https:\/\/id.crossref.org\/issn\/0009-4722","issn-type":"print"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1002\/bjs.1800720807","article-title":"Staples or sutures to colorectal anastomoses: prospective randomized trial","volume":"72","author":"McGinn FP","year":"1985","journal-title":"Br J Surg","ISSN":"https:\/\/id.crossref.org\/issn\/0007-1323","issn-type":"print"},{"key":"ref4","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1002\/bjs.1800620214","article-title":"A comparison of one layer and two layer techniques for colorectal anastomosis","volume":"62","author":"Everett WG","year":"1975","journal-title":"Br J Surg","ISSN":"https:\/\/id.crossref.org\/issn\/0007-1323","issn-type":"print"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"241","DOI":"10.3109\/02841868909111255","article-title":"Results of surgery for cancer of the rectum with sphincter conservation.","volume":"2","author":"Gonzalez EM","year":"1989","journal-title":"Acta Oncol","ISSN":"https:\/\/id.crossref.org\/issn\/0284-186X","issn-type":"print"},{"key":"ref6","first-page":"425","article-title":"Anastomoses colo-rectales: \u00e0 la main ou \u00e0 la machine","volume":"116","author":"Elhaddad A.","year":"1990","journal-title":"Chirurg","ISSN":"https:\/\/id.crossref.org\/issn\/0009-4722","issn-type":"print"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1002\/bjs.1800780322","article-title":"Suturing or stapling in gastrointestinal surgery: a prospective randomized study","volume":"78","year":"1991","journal-title":"Br J Surg","ISSN":"https:\/\/id.crossref.org\/issn\/0007-1323","issn-type":"print"},{"key":"ref8","first-page":"295","article-title":"Le point sur les meilleurs anastomoses apr\u00e8s res\u00e9ction colique","volume":"45","author":"Kracht M.","year":"1991","journal-title":"Ann Chir","ISSN":"https:\/\/id.crossref.org\/issn\/0003-3944","issn-type":"print"},{"key":"ref9","first-page":"133","article-title":"A comparison of stapled vs. handsewn anastomoses in anterior resection for carcinoma rectum","volume":"31","author":"Sarker SK","year":"1994","journal-title":"Indian J Cancer","ISSN":"https:\/\/id.crossref.org\/issn\/0019-509X","issn-type":"print"},{"key":"ref10","first-page":"167","article-title":"Advantages and disadvantages of mechanical vs. manual anastomoses in colorectal surgery","volume":"156","author":"Cajozzo M","year":"1990","journal-title":"Acta Chir Scand","ISSN":"https:\/\/id.crossref.org\/issn\/0001-5482","issn-type":"print"},{"key":"ref11","first-page":"484","article-title":"Supraperitoneal colorectal anastomosis: handsewn versus circular staples: a controlled clinical trial","volume":"116","author":"Fingerhut A","year":"1994","journal-title":"Surgery","ISSN":"https:\/\/id.crossref.org\/issn\/0039-6060","issn-type":"print"},{"key":"ref12","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1016\/S0039-6060(05)80362-9","article-title":"Supraperitoneal colorectal anastomosis: handsewn vs. circular staples: a controlled clinical trial","volume":"118","author":"Fingerhut A","year":"1995","journal-title":"Surgery","ISSN":"https:\/\/id.crossref.org\/issn\/0039-6060","issn-type":"print"},{"issue":"2","key":"ref13","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1007\/BF02238246","article-title":"Handsewn vs. stapled anastomoses in colon and rectal surgery: a meta-analysis","volume":"41","author":"MacRae HM","year":"1998","journal-title":"Dis Colon Rectum","ISSN":"https:\/\/id.crossref.org\/issn\/0012-3706","issn-type":"print"},{"key":"ref14","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1001\/jama.1995.03520290060030","article-title":"Empirical evidence of bias","volume":"273","author":"Schulz KF","year":"1995","journal-title":"JAMA","ISSN":"https:\/\/id.crossref.org\/issn\/0098-7484","issn-type":"print"},{"key":"ref15","series-title":"Review Manager","volume-title":"Cochrane Reviewers' Handbook 4.0","author":"Clarke M","year":"1999"},{"key":"ref16","series-title":"Compression intestinal anastomosis with AKA Russian instrument: analysis of clinical, radiological and endoscopic results","author":"Matos D."},{"key":"ref17","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1002\/bjs.1800830108","article-title":"Prospective study of hand-sutured anastomosis after colorectal resection","volume":"83","author":"Mann B","year":"1996","journal-title":"Br J Surg","ISSN":"https:\/\/id.crossref.org\/issn\/0007-1323","issn-type":"print"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"1224","DOI":"10.1002\/bjs.1800810850","article-title":"Leakage from stapled low anastomosis after total mesorectal excision for carcinoma of the rectum","volume":"81","author":"Karanjia ND","year":"1994","journal-title":"Br J Surg","ISSN":"https:\/\/id.crossref.org\/issn\/0007-1323","issn-type":"print"},{"key":"ref19","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1002\/bjs.1800790406","article-title":"Anterior resection without a defunctioning colostomy: questions of safety","volume":"79","author":"Mealy K","year":"1992","journal-title":"Br J Surg","ISSN":"https:\/\/id.crossref.org\/issn\/0007-1323","issn-type":"print"},{"key":"ref20","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.1002\/bjs.1800771006","article-title":"Intraoperative air testing of colorectal anastomoses: a prospective, randomized trial","volume":"77","author":"Beard JD","year":"1990","journal-title":"Br J Surg","ISSN":"https:\/\/id.crossref.org\/issn\/0007-1323","issn-type":"print"},{"key":"ref21","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1001\/archsurg.1975.01360150023004","article-title":"Use of a mechanical suturing apparatus in low colorectal anastomosis","volume":"110","author":"Fain SN","year":"1975","journal-title":"Arch Surg","ISSN":"https:\/\/id.crossref.org\/issn\/0004-0010","issn-type":"print"},{"issue":"6","key":"ref22","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1097\/00000658-197906000-00017","article-title":"A stapling instrument for end-to-end inverting anastomosis in the gastrointestinal tract","volume":"189","author":"Ravitch MM","year":"1979","journal-title":"Ann Surg","ISSN":"https:\/\/id.crossref.org\/issn\/0003-4932","issn-type":"print"},{"key":"ref23","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1016\/0002-9610(80)90336-0","article-title":"Experience with the EEA stapling device","volume":"139","author":"Shahinian TK","year":"1980","journal-title":"Am J Surg","ISSN":"https:\/\/id.crossref.org\/issn\/0002-9610","issn-type":"print"},{"key":"ref24","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1002\/bjs.1800680514","article-title":"The low stapled anastomosis","volume":"68","author":"Heald RJ","year":"1981","journal-title":"Br J Surg","ISSN":"https:\/\/id.crossref.org\/issn\/0007-1323","issn-type":"print"},{"key":"ref25","series-title":"Mechanical versus manual suturing for anastomosis of the colon","author":"Lustosa SAS","year":"2000"}],"container-title":["Sao Paulo Medical Journal"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/pdf\/spmj\/v120n5\/12465.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,5,24]],"date-time":"2017-05-24T18:18:21Z","timestamp":1495649901000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S1516-31802002000500002&lng=en&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2002,7]]},"references-count":25,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2002,7]]}},"alternative-id":["S1516-31802002000500002"],"URL":"https:\/\/doi.org\/10.1590\/s1516-31802002000500002","relation":{},"ISSN":["1516-3180"],"issn-type":[{"value":"1516-3180","type":"electronic"}],"subject":[],"published":{"date-parts":[[2002,7]]}}}