{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,24]],"date-time":"2026-01-24T01:01:01Z","timestamp":1769216461229,"version":"3.49.0"},"reference-count":24,"publisher":"FapUNIFESP (SciELO)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Einstein (S\u00e3o Paulo)"],"published-print":{"date-parts":[[2014,3]]},"abstract":"<jats:p> Objective : To investigate the influence of the site of measurement of transcutaneous bilirubin (forehead or sternum) in reproducibility of results as compared to plasma bilirubin.  Methods : A cohort study including 58 term newborns with no hemolytic disease. Transcutaneous measurements were performed on the forehead (halfway between the headline and the glabella, from the left toward the right side, making consecutive determinations, one-centimeter apart) and the sternum (five measurements, from the suprasternal notch to the xiphoid process with consecutive determinations, one-centimeter apart) using Bilicheck\u00ae (SpectRx Inc, Norcross, Georgia, USA). The correlation and agreement between both methods and plasma bilirubin were calculated.  Results : There was a strong linear correlation between both determinations of serum bilirubin at the forehead and sternum (r=0.704; p&lt;0.01 and r=0.653; p&lt;0.01, respectively). There was correspondence of the mean values of transcutaneous bilirubin measured on the sternum (9.9\u00b12.2mg\/dL) compared to plasma levels (10.2\u00b11.7mg\/dL), but both differ from the values measured on the forehead (8.6\u00b12.0mg\/dL), p&lt;0.05.  Conclusion : In newborn term infants with no hemolytic disease, measuring of transcutaneous bilirubin on the sternum had higher accuracy as compared to serum bilirubin measurement on the forehead.<\/jats:p>","DOI":"10.1590\/s1679-45082014ao2711","type":"journal-article","created":{"date-parts":[[2015,2,6]],"date-time":"2015-02-06T12:27:01Z","timestamp":1423225621000},"page":"11-15","source":"Crossref","is-referenced-by-count":14,"title":["Influence of assessment site in measuring transcutaneous bilirubin"],"prefix":"10.1590","volume":"12","author":[{"given":"Cristiane Maria da","family":"Concei\u00e7\u00e3o","sequence":"first","affiliation":[{"name":"Hospital Israelita Albert Einstein,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria Fernanda Pellegrino da Silva","family":"Dornaus","sequence":"additional","affiliation":[{"name":"Hospital Israelita Albert Einstein,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria Aparecida","family":"Portella","sequence":"additional","affiliation":[{"name":"Hospital Israelita Albert Einstein,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alice D\u2019Agostini","family":"Deutsch","sequence":"additional","affiliation":[{"name":"Hospital Israelita Albert Einstein,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Celso Moura","family":"Rebello","sequence":"additional","affiliation":[{"name":"Hospital Israelita Albert Einstein,  Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"530","reference":[{"issue":"5","key":"ref1","doi-asserted-by":"crossref","first-page":"F317","DOI":"10.1136\/adc.2008.150714","article-title":"Visual assessment of jaundice in term and late preterm infants","volume":"94","author":"Keren R","year":"2009","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"issue":"1","key":"ref2","doi-asserted-by":"crossref","first-page":"e130","DOI":"10.1542\/peds.114.1.e130","article-title":"American Academy of Pediatrics Subcommittee on Hyperbilirubinemia. An evidence-based review of important issues concerning neonatal hyperbilirubinemia","volume":"114","author":"Ip S","year":"2004","journal-title":"Pediatrics"},{"issue":"4","key":"ref3","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1590\/S0021-75572007000500005","article-title":"Acompanhamento da icter\u00edcia neonatal em rec\u00e9m-nascidos de termo e prematuros tardios","volume":"83","author":"Facchini FP","year":"2007","journal-title":"J Pediatr (Rio J)"},{"issue":"1","key":"ref4","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1542\/peds.114.1.297","article-title":"Management of hyperbilirubinemia in the newborn infant 35 or more weeks of gestation","volume":"114","year":"2004","journal-title":"Pediatrics"},{"issue":"2","key":"ref5","first-page":"149","article-title":"Avalia\u00e7\u00e3o da variabilidade da dosagem transcut\u00e2nea de bilirrubina pelo Bilicheck em neonatos","volume":"24","author":"Facchini FP","year":"2006","journal-title":"Rev Paul Pediatria"},{"issue":"4","key":"ref6","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1111\/j.1440-1754.2007.01062.x","article-title":"Prediction of severe hyperbilirubinaemia using the Bilicheck transcutaneous bilirubinometer","volume":"43","author":"Boo NY","year":"2007","journal-title":"J Paediatr Child Health"},{"issue":"1","key":"ref7","first-page":"35","article-title":"Disagreement between parents and health professionals regarding pain intensity in critically ill neonates","volume":"84","author":"Elias LS","year":"2008","journal-title":"J Pediatr (Rio J)"},{"issue":"2","key":"ref8","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1111\/j.1651-2227.2002.tb01696.x","article-title":"A new transcutaneous bilirubinometer, Bilicheck, used in the neonatal intensive care unit and the maternity ward","volume":"91","author":"Ebbesen F","year":"2002","journal-title":"Acta Pediatr"},{"issue":"7","key":"ref9","first-page":"771","article-title":"Non-invasive estimation of total serum bilirrubin by multi-wavelength spectral reflectance in neonates","volume":"37","author":"Lodha R","year":"2000","journal-title":"Indian Pediatr"},{"issue":"2","key":"ref10","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1053\/siny.2002.0100","article-title":"Non invasive bilirubinometry in neonatal jaundice","volume":"7","author":"Bertini G","year":"2002","journal-title":"Semin. Neonatol"},{"key":"ref11","doi-asserted-by":"crossref","DOI":"10.1186\/1471-2431-12-70","article-title":"Measuring transcutaneous bilirubin: a comparative analysis of three devices on a multiracial population","volume":"12","author":"Raimondi F","year":"2012","journal-title":"BMC Pediatr"},{"issue":"5","key":"ref12","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1542\/peds.2013-1713","article-title":"Reliability of Transcutaneous Bilirubin Devices in Preterm Infants: A Systematic Review","volume":"132","author":"Nagar G","year":"2013","journal-title":"Pediatrics"},{"issue":"7","key":"ref13","doi-asserted-by":"crossref","first-page":"1280","DOI":"10.1373\/clinchem.2008.121889","article-title":"Hyperbilirubinemia and Transcutaneous Bilirubinometry","volume":"55","author":"El-Beshbishi SN","year":"2009","journal-title":"Clin Chem"},{"issue":"3","key":"ref14","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1590\/S0021-75572007000400015","article-title":"Compara\u00e7\u00e3o entre a dosagem transcut\u00e2nea e plasm\u00e1tica de bilirrubina","volume":"83","author":"Leite MG","year":"2007","journal-title":"J Pediatr (Rio J)"},{"issue":"9","key":"ref15","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1038\/sj.jp.7211141","article-title":"Comparison of skin sites for estimating serum total bilirubin in in-patients and out- patients: chest is superior to brow","volume":"24","author":"Poland RL","year":"2004","journal-title":"J Perinatol"},{"issue":"1","key":"ref16","first-page":"6","article-title":"Comparative study between plasma and transcutaneous bilirubin measurements in newborns","volume":"29","author":"Povaluk P","year":"2011","journal-title":"Rev Paul Pediatr"},{"issue":"6","key":"ref17","doi-asserted-by":"crossref","first-page":"1264","DOI":"10.1542\/peds.107.6.1264","article-title":"Transcutaneous Bilirubin Measurement: A multicenter evaluation of a new device","volume":"107","author":"Rubaltelli F","year":"2001","journal-title":"Pediatrics"},{"issue":"6","key":"ref18","doi-asserted-by":"crossref","first-page":"1628","DOI":"10.1542\/peds.113.6.1628","article-title":"Evaluation of a new transcutaneous bilirubinometer","volume":"113","author":"Maisels MJ","year":"2004","journal-title":"Pediatrics"},{"issue":"2","key":"ref19","doi-asserted-by":"crossref","first-page":"F137","DOI":"10.1136\/fn.87.2.F137","article-title":"A comparison of transcutaneous bilirubinometers: SpectRx BiliCheck versus Minolta AirShields","volume":"87","author":"Wong CM","year":"2002","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"key":"ref20","series-title":"Respironics. BiliChek\u00ae Noninvasive bilirubin analyzer: suggested usage protocol","year":"2006"},{"issue":"3","key":"ref21","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1111\/j.1651-2227.2003.tb00554.x","article-title":"Transcutaneous bilirubinometry during and after phototherapy","volume":"92","author":"Tan KL","year":"2003","journal-title":"Acta Paediatr"},{"issue":"1","key":"ref22","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1080\/08035250410023179","article-title":"In vivo spectroscopy of jaundiced newborn skin reveals more than a bilirubin index","volume":"94","author":"Randeberg LL","year":"2005","journal-title":"Acta Paediatr"},{"key":"ref23","series-title":"Evidence-Based Practice for Point-of-Care Testing - The National Academy of Clinical Biochemistry Laboratory Medicine Practice Guidelines","first-page":"5","volume-title":"Transcutaneous bilirubin testing","author":"Kazmierczak S","year":"2006"},{"key":"ref24","series-title":"Consensos Nacionais em Neonatologia. Se\u00e7\u00e3o de Neonatologia","volume-title":"Icter\u00edcia neonatal","author":"Quintas C","year":"2013"}],"container-title":["Einstein (S\u00e3o Paulo)"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/pdf\/eins\/v12n1\/1679-4508-eins-12-1-0011.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,5,23]],"date-time":"2017-05-23T07:58:48Z","timestamp":1495526328000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S1679-45082014000100004&lng=en&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,3]]},"references-count":24,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2014,3]]}},"alternative-id":["S1679-45082014000100004"],"URL":"https:\/\/doi.org\/10.1590\/s1679-45082014ao2711","relation":{},"ISSN":["1679-4508"],"issn-type":[{"value":"1679-4508","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,3]]}}}