{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T06:21:12Z","timestamp":1789712472603,"version":"4.0.1"},"reference-count":49,"publisher":"Elsevier BV","issue":"12","license":[{"start":{"date-parts":[[2010,1,1]],"date-time":"2010-01-01T00:00:00Z","timestamp":1262304000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2010,1,1]],"date-time":"2010-01-01T00:00:00Z","timestamp":1262304000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2011,3,21]],"date-time":"2011-03-21T00:00:00Z","timestamp":1300665600000},"content-version":"vor","delay-in-days":444,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/3.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinics"],"published-print":{"date-parts":[[2010,1]]},"DOI":"10.1590\/s1807-59322010001200002","type":"journal-article","created":{"date-parts":[[2011,2,24]],"date-time":"2011-02-24T18:58:50Z","timestamp":1298573930000},"page":"1223-1228","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":79,"title":["Evaluation of machine learning classifiers in keratoconus detection from orbscan II examinations"],"prefix":"10.1016","volume":"65","author":[{"given":"Murilo Barreto","family":"Souza","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabricio Witzel","family":"Medeiros","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Danilo Barreto","family":"Souza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Renato","family":"Garcia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Milton Ruiz","family":"Alves","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1590\/S1807-59322010001200002_bib1","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1016\/0039-6257(84)90094-8","article-title":"Keratoconus and related noninflammatory corneal thinning disorders","volume":"28","author":"Krachmer","year":"1984","journal-title":"Surv Ophthalmol"},{"key":"10.1590\/S1807-59322010001200002_bib2","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/S0039-6257(97)00119-7","article-title":"Keratoconus","volume":"42","author":"Rabinowitz","year":"1998","journal-title":"Surv Ophthalmol"},{"key":"10.1590\/S1807-59322010001200002_bib3","first-page":"57","article-title":"Automated keratoconus screening with corneal topography analysis","volume":"35","author":"Maeda","year":"1994","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1590\/S1807-59322010001200002_bib4","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.ajo.2006.12.030","article-title":"Keratoconus: it is hard to define, but","volume":"143","author":"Belin","year":"2007","journal-title":"Am J Ophthalmol"},{"key":"10.1590\/S1807-59322010001200002_bib5","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/S1532-0464(02)00513-0","article-title":"Neural network-based system for early keratoconus detection from corneal topography","volume":"35","author":"Accardo","year":"2002","journal-title":"J Biomed Inform"},{"key":"10.1590\/S1807-59322010001200002_bib6","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.jcrs.2006.02.060","article-title":"Corneal elevation indices in normal and keratoconic eyes","volume":"32","author":"Fam","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"10.1590\/S1807-59322010001200002_bib7","first-page":"43","article-title":"Initial biopsy outcome prediction \u2013 head-to-head comparison of a logistic regression-based nomogram versus artificial neural network","volume":"51","author":"Stephan","year":"2007","journal-title":"Eur Urol"},{"key":"10.1590\/S1807-59322010001200002_bib8","first-page":"9","article-title":"Current keratoconus detection methods compared with a neural network approach","volume":"38","author":"Smolek","year":"1997","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1590\/S1807-59322010001200002_bib9","doi-asserted-by":"crossref","first-page":"22","DOI":"10.3928\/1081-597X-20050902-12","article-title":"Screening patients with the corneal navigator","volume":"21","author":"Klyce","year":"2005","journal-title":"J Refract Surg"},{"key":"10.1590\/S1807-59322010001200002_bib10","series-title":"Neural networks: a comprehensive foundation","author":"Haykin","year":"1999"},{"key":"10.1590\/S1807-59322010001200002_bib11","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.jcrs.2004.09.047","article-title":"Orbscan computerized topography: attributes, applications, and limitations","volume":"31","author":"Cairns","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"10.1590\/S1807-59322010001200002_bib12","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/S0886-3350(97)80115-0","article-title":"Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations","volume":"23","author":"Holladay","year":"1997","journal-title":"J Cataract Refract Surg"},{"key":"10.1590\/S1807-59322010001200002_bib13","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1001\/archopht.1995.01100070044023","article-title":"Comparison of methods for detecting keratoconus using videokeratography","volume":"113","author":"Maeda","year":"1995","journal-title":"Arch Ophthalmol"},{"key":"10.1590\/S1807-59322010001200002_bib14","first-page":"8","article-title":"Computer-assisted corneal topography in keratoconus","volume":"5","author":"Rabinowitz","year":"1989","journal-title":"Refract Corneal Surg"},{"key":"10.1590\/S1807-59322010001200002_bib15","doi-asserted-by":"crossref","DOI":"10.1145\/1656274.1656278","article-title":"The WEKA Data Mining Software: An Update","volume":"11","author":"Hall","year":"2009","journal-title":"SIGKDD Explorations"},{"key":"10.1590\/S1807-59322010001200002_bib16","series-title":"Netlab: Algorithms for Pattern Recognition","author":"Nabney","year":"2004"},{"key":"10.1590\/S1807-59322010001200002_bib17","series-title":"Computer systems that learn : classification and prediction methods from statistics, neural nets, machine learning, and expert systems","author":"Weiss","year":"1991"},{"key":"10.1590\/S1807-59322010001200002_bib18","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1148\/radiology.143.1.7063747","article-title":"The meaning and use of the area under a receiver operating characteristic (ROC) curve","volume":"143","author":"Hanley","year":"1982","journal-title":"Radiology"},{"key":"10.1590\/S1807-59322010001200002_bib19","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1177\/016173460502700304","article-title":"A tutorial on the use of ROC analysis for computer-aided diagnostic systems","volume":"27","author":"Scheipers","year":"2005","journal-title":"Ultrason Imaging"},{"key":"10.1590\/S1807-59322010001200002_bib20","first-page":"22","article-title":"Evaluating classifiers using ROC curves","volume":"6","author":"Prati","year":"2008","journal-title":"IEEE Am\u00e9rica Latina"},{"key":"10.1590\/S1807-59322010001200002_bib21","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1136\/bmj.309.6948.188","article-title":"Diagnostic tests 3: receiver operating characteristic plots","volume":"309","author":"Altman","year":"1994","journal-title":"BMJ"},{"key":"10.1590\/S1807-59322010001200002_bib22","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1109\/72.548164","article-title":"Median radial basis function neural network","volume":"7","author":"Bors","year":"1996","journal-title":"IEEE Trans Neural Netw"},{"key":"10.1590\/S1807-59322010001200002_bib23","series-title":"Data Mining: Practical Machine Learning Tools and Techniques","author":"Witten","year":"2005"},{"key":"10.1590\/S1807-59322010001200002_bib24","series-title":"Advances in Kernel Methods: Support Vector Learning","article-title":"Fast training of support vector machines using sequential minimal optimization","author":"Platt","year":"1998"},{"key":"10.1590\/S1807-59322010001200002_bib25","series-title":"Neural Smithing: Supervised Learning in Feedforward Artificial Neural Networks","author":"Reed","year":"1999"},{"key":"10.1590\/S1807-59322010001200002_bib26","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.cmpb.2008.07.006","article-title":"Neural network based detection of hard exudates in retinal images","volume":"93","author":"Garcia","year":"2009","journal-title":"Comput Methods Programs Biomed"},{"key":"10.1590\/S1807-59322010001200002_bib27","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/S0893-6080(05)80056-5","article-title":"A scaled conjugate gradient algorithm for fast supervised learning","volume":"6","author":"Moller","year":"1993","journal-title":"Neural Networks"},{"key":"10.1590\/S1807-59322010001200002_bib28","series-title":"Neural Networks for Pattern Recognition","author":"Bishop","year":"1995"},{"key":"10.1590\/S1807-59322010001200002_bib29","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1148\/radiology.148.3.6878708","article-title":"A method of comparing the areas under receiver operating characteristic curves derived from the same cases","volume":"148","author":"Hanley","year":"1983","journal-title":"Radiology"},{"key":"10.1590\/S1807-59322010001200002_bib30","first-page":"46","article-title":"Biomicroscopic signs and disease severity in keratoconus","volume":"15","author":"Zadnik","year":"1996","journal-title":"Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study Group. Cornea"},{"key":"10.1590\/S1807-59322010001200002_bib31","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/S0886-3350(99)00195-9","article-title":"KISA% index: a quantitative videokeratography algorithm embodying minimal topographic criteria for diagnosing keratoconus","volume":"25","author":"Rabinowitz","year":"1999","journal-title":"J Cataract Refract Surg"},{"key":"10.1590\/S1807-59322010001200002_bib32","doi-asserted-by":"crossref","first-page":"9","DOI":"10.3928\/1081-597X-19950901-14","article-title":"Videokeratographic indices to aid in screening for keratoconus","volume":"11","author":"Rabinowitz","year":"1995","journal-title":"J Refract Surg"},{"key":"10.1590\/S1807-59322010001200002_bib33","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/S0161-6420(02)01276-9","article-title":"Corneal thickness indices discriminate between keratoconus and contact lens-induced corneal thinning","volume":"109","author":"Pflugfelder","year":"2002","journal-title":"Ophthalmology"},{"key":"10.1590\/S1807-59322010001200002_bib34","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1016\/S0161-6420(02)01030-8","article-title":"Standardized color-coded scales for anterior and posterior elevation maps of scanning slit corneal topography","volume":"109","author":"Tanabe","year":"2002","journal-title":"Ophthalmology"},{"key":"10.1590\/S1807-59322010001200002_bib35","first-page":"35","article-title":"Neural network classification of corneal topography. Preliminary demonstration","volume":"36","author":"Maeda","year":"1995","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1590\/S1807-59322010001200002_bib36","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1097\/01.OPX.0000153193.41554.A1","article-title":"Preliminary results of neural networks and zernike polynomials for classification of videokeratography maps","volume":"82","author":"Carvalho","year":"2005","journal-title":"Optom Vis Sci"},{"key":"10.1590\/S1807-59322010001200002_bib37","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1016\/j.ajo.2006.11.030","article-title":"Evaluation of keratoconus in Asians: role of Orbscan II and Tomey TMS-2 corneal topography","volume":"143","author":"Lim","year":"2007","journal-title":"Am J Ophthalmol"},{"key":"10.1590\/S1807-59322010001200002_bib38","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/S0161-6420(02)01121-1","article-title":"Role of Orbscan II in screening keratoconus suspects before refractive corneal surgery","volume":"109","author":"Rao","year":"2002","journal-title":"Ophthalmology"},{"key":"10.1590\/S1807-59322010001200002_bib39","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.ajo.2006.11.044","article-title":"Identification of scanning slit-beam topographic parameters important in distinguishing normal from keratoconic corneal morphologic features","volume":"143","author":"Sonmez","year":"2007","journal-title":"Am J Ophthalmol"},{"key":"10.1590\/S1807-59322010001200002_bib40","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1167\/iovs.04-1122","article-title":"Relevance vector machine and support vector machine classifier analysis of scanning laser polarimetry retinal nerve fiber layer measurements","volume":"46","author":"Bowd","year":"2005","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1590\/S1807-59322010001200002_bib41","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1097\/OPX.0b013e3181783ab6","article-title":"Machine learning classifiers in glaucoma","volume":"85","author":"Bowd","year":"2008","journal-title":"Optom Vis Sci"},{"key":"10.1590\/S1807-59322010001200002_bib42","first-page":"9","article-title":"Comparing machine learning classifiers for diagnosing glaucoma from standard automated perimetry","volume":"43","author":"Goldbaum","year":"2002","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1590\/S1807-59322010001200002_bib43","article-title":"Eletronic statistics texbook","author":"StatSoft","year":"2010"},{"key":"10.1590\/S1807-59322010001200002_bib44","series-title":"A Practical Guide to Support Vector Classification","author":"Hsu","year":"2010"},{"key":"10.1590\/S1807-59322010001200002_bib45","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/S1532-0464(03)00034-0","article-title":"Logistic regression and artificial neural network classification models: a methodology review","volume":"35","author":"Dreiseitl","year":"2002","journal-title":"J Biomed Inform"},{"key":"10.1590\/S1807-59322010001200002_bib46","series-title":"Adaptive Control Processes: a Guided Tour","author":"Bellman","year":"1961"},{"key":"10.1590\/S1807-59322010001200002_bib47","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/0010-4809(81)90012-4","article-title":"An analysis of physician attitudes regarding computer-based clinical consultation systems","volume":"14","author":"Teach","year":"1981","journal-title":"Comput Biomed Res"},{"key":"10.1590\/S1807-59322010001200002_bib48","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1148\/radiographics.14.4.7938772","article-title":"Artificial intelligence in radiology: decision support systems","volume":"14","author":"Kahn","year":"1994","journal-title":"Radiographics"},{"key":"10.1590\/S1807-59322010001200002_bib49","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1002\/1097-0142(20010415)91:8+<1615::AID-CNCR1175>3.0.CO;2-L","article-title":"Artificial neural networks: opening the black box","volume":"91","author":"Dayhoff","year":"2001","journal-title":"Cancer"}],"container-title":["Clinics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1807593222015885?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1807593222015885?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.scielo.br\/pdf\/clin\/v65n12\/02.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T07:06:09Z","timestamp":1761721569000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1807593222015885"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,1]]},"references-count":49,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2010,1]]}},"alternative-id":["S1807593222015885"],"URL":"https:\/\/doi.org\/10.1590\/s1807-59322010001200002","relation":{},"ISSN":["1807-5932"],"issn-type":[{"value":"1807-5932","type":"print"}],"subject":[],"published":{"date-parts":[[2010,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Evaluation of machine learning classifiers in keratoconus detection from orbscan II examinations","name":"articletitle","label":"Article Title"},{"value":"Clinics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1590\/S1807-59322010001200002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2010 CLINICS. Published by Elsevier Spain","name":"copyright","label":"Copyright"}]}}