{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T17:44:52Z","timestamp":1793727892178,"version":"4.6.1"},"reference-count":19,"publisher":"FapUNIFESP (SciELO)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Dental Press J. Orthod."],"published-print":{"date-parts":[[2013,10]]},"abstract":"<jats:p>OBJECTIVE: The aim of this study was to compare by means of McNamara as well as Legan and Burstone's cephalometric analyses, both manual and digitized (by Dentofacial Planner Plus and Dolphin Image software) prediction tracings to post-surgical results. METHODS: Pre and post-surgical teleradiographs (6 months) of 25 long face patients subjected to combined orthognathic surgery were selected. Manual and computerized prediction tracings of each patient were performed and cephalometrically compared to post-surgical outcomes. This protocol was repeated in order to evaluate the method error and statistical evaluation was conducted by means of analysis of variance and Tukey's test. RESULTS: A higher frequency of cephalometric variables, which were not statistically different from the actual post-surgical results for the manual method, was observed. It was followed by DFPlus and Dolphin software; in which similar cephalometric values for most variables were observed. CONCLUSION: It was concluded that the manual method seemed more reliable, although the predictability of the evaluated methods (computerized and manual) proved to be reasonably satisfactory and similar.<\/jats:p>","DOI":"10.1590\/s2176-94512013000500010","type":"journal-article","created":{"date-parts":[[2014,2,5]],"date-time":"2014-02-05T19:24:57Z","timestamp":1391628297000},"page":"53-58","source":"Crossref","is-referenced-by-count":12,"title":["Cephalometric evaluation of the predictability of bimaxillary surgical-orthodontic treatment outcomes in long face pattern patients: a retrospective study"],"prefix":"10.1590","volume":"18","author":[{"given":"Carla Maria Melleiro","family":"Gimenez","sequence":"first","affiliation":[{"name":"Universidade Estadual Paulista, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco Antonio","family":"Bertoz","sequence":"additional","affiliation":[{"name":"Universidade Estadual Paulista, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marisa Aparecida Cabrini","family":"Gabrielli","sequence":"additional","affiliation":[{"name":"Universidade Estadual Paulista, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oswaldo","family":"Magro Filho","sequence":"additional","affiliation":[{"name":"Universidade Estadual Paulista, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Idelmo","family":"Garcia","sequence":"additional","affiliation":[{"name":"Universidade Estadual Paulista, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Valfrido Antonio","family":"Pereira Filho","sequence":"additional","affiliation":[{"name":"Universidade Estadual Paulista, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"530","reference":[{"issue":"2","key":"ref1","first-page":"28","article-title":"Posi\u00e7\u00e3o labial em repouso e sorriso e a sua rela\u00e7\u00e3o com os incisivos centrais superiores","volume":"1","author":"Ara\u00fajo CU","year":"1987","journal-title":"Rev Odontol Univ S\u00e3o Paulo","ISSN":"https:\/\/id.crossref.org\/issn\/0103-0663","issn-type":"print"},{"issue":"2","key":"ref2","first-page":"168","article-title":"Cephalometric reliability: a full ANOVA model for the estimation of true and error variance","volume":"57","author":"Buschang PH","year":"1987","journal-title":"Angle Orthod","ISSN":"https:\/\/id.crossref.org\/issn\/0003-3219","issn-type":"print"},{"issue":"2","key":"ref3","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1111\/ocr.1999.2.2.85","article-title":"Mandibular setback osteotomy: facial soft tissue behavior and possibility to improve the accuracy of the soft tissue profile prediction with the use of a computerized cephalometric program: Quick Ceph Image Pro: v. 2,5","volume":"2","author":"Chunmaneechote P","year":"1999","journal-title":"Clin Orthod Res"},{"issue":"2","key":"ref4","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1093\/ortho\/30.2.149","article-title":"The validity of computerized orthognathic predictions","volume":"30","author":"Cousley RR","year":"2003","journal-title":"J Orthod"},{"issue":"4","key":"ref5","first-page":"285","article-title":"Prediction of soft tissue profiles in orthodontic surgery with the Dentofacial Planner","volume":"14","author":"Csaszar GR","year":"1999","journal-title":"Int J Adult Orthodon Orthognath Surg","ISSN":"https:\/\/id.crossref.org\/issn\/0742-1931","issn-type":"print"},{"key":"ref6","series-title":"Altera\u00e7\u00f5es de posi\u00e7\u00e3o dos tecidos moles da face ap\u00f3s osteotomias Le Fort I: um estudo retrospectivo","author":"Gabrielli MFR","year":"1990"},{"issue":"5","key":"ref7","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1016\/j.joms.2005.01.004","article-title":"Prediction accuracy of computer-assisted surgical visual treatment objectives as compared with conventional visual treatment objectives","volume":"63","author":"Gossett CB","year":"2005","journal-title":"J Oral Maxillofac Surg","ISSN":"https:\/\/id.crossref.org\/issn\/0278-2391","issn-type":"print"},{"issue":"6","key":"ref8","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1016\/S0889-5406(94)70084-2","article-title":"The integumental profile: a reflection of the underlying skeletal configuration?","volume":"106","author":"Kuyl MH","year":"1994","journal-title":"Am J Orthod Dentofacial Orthop","ISSN":"https:\/\/id.crossref.org\/issn\/0889-5406","issn-type":"print"},{"issue":"10","key":"ref9","first-page":"744","article-title":"Soft tissue cephalometric analysis for orthognathic surgery","volume":"38","author":"Legan HL","year":"1980","journal-title":"J Oral Surg","ISSN":"https:\/\/id.crossref.org\/issn\/0022-3255","issn-type":"print"},{"issue":"3","key":"ref10","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1053\/joms.2003.50058","article-title":"The accuracy of video imaging prediction in soft tissue outcome after bimaxillary orthognathic surgery","volume":"61","author":"Lu CH","year":"2003","journal-title":"J Oral Maxillofac Surg","ISSN":"https:\/\/id.crossref.org\/issn\/0278-2391","issn-type":"print"},{"key":"ref11","series-title":"Erro de reprodutibilidade das medidas das an\u00e1lises cefalom\u00e9tricas de Steiner e Ricketts pelos m\u00e9todos convencional e computadorizado","author":"Martins LP","year":"1993"},{"issue":"6","key":"ref12","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1016\/S0002-9416(84)90352-X","article-title":"A method of cephalometric evaluation","volume":"86","author":"McNamara JA Jr.","year":"1984","journal-title":"Am J Orthod","ISSN":"https:\/\/id.crossref.org\/issn\/0002-9416","issn-type":"print"},{"issue":"3","key":"ref13","first-page":"265","article-title":"Method to verify the accuracy of model surgery and prediction tracing","volume":"11","author":"Omura T","year":"1996","journal-title":"Int J Adult Orthodon Orthognath Surg","ISSN":"https:\/\/id.crossref.org\/issn\/0742-1931","issn-type":"print"},{"issue":"1","key":"ref14","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/0889-5406(86)90027-2","article-title":"Soft tissue profile: fallacies of hard tissue standards in treatment planning","volume":"90","author":"Park YC","year":"1986","journal-title":"Am J Orthod Dentofacial Orthop","ISSN":"https:\/\/id.crossref.org\/issn\/0889-5406","issn-type":"print"},{"key":"ref15","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1002\/rcs.127","article-title":"The accuracy of computer-assisted surgical planning in soft tissue prediction following orthognathic surgery","volume":"3","author":"Pektas ZO","year":"2007","journal-title":"Int J Med Robot"},{"issue":"6","key":"ref16","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1016\/j.ijom.2005.04.003","article-title":"Dolphin Imaging Software: an analysis of the accuracy of cephalometric digitization and orthognathic prediction","volume":"34","author":"Power G","year":"2005","journal-title":"Int J Oral Maxillofac Surg","ISSN":"https:\/\/id.crossref.org\/issn\/0901-5027","issn-type":"print"},{"issue":"3","key":"ref17","doi-asserted-by":"crossref","first-page":"108","DOI":"10.3109\/10929089809149838","article-title":"Accuracy of cephalometric and video imaging program Dentofacial Planner Plus in orthognathic surgical planning","volume":"3","author":"Schultes G","year":"1998","journal-title":"Comput Aided Surg","ISSN":"https:\/\/id.crossref.org\/issn\/1092-9088","issn-type":"print"},{"issue":"5","key":"ref18","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1016\/j.ajodo.2004.02.003","article-title":"A comparison of current prediction imaging programs","volume":"125","author":"Smith JD","year":"2004","journal-title":"Am J Orthod Dentofacial Orthop","ISSN":"https:\/\/id.crossref.org\/issn\/0889-5406","issn-type":"print"},{"issue":"6","key":"ref19","first-page":"57","article-title":"Estudo comparativo entre os m\u00e9todos de an\u00e1lise cefalom\u00e9trica manual e computadorizada","volume":"5","author":"Trajano FS","year":"2000","journal-title":"Rev Dental Press Ortod Ortop Facial"}],"container-title":["Dental Press Journal of Orthodontics"],"original-title":[],"link":[{"URL":"http:\/\/www.scielo.br\/pdf\/dpjo\/v18n5\/10.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,7]],"date-time":"2019-08-07T10:30:53Z","timestamp":1565173853000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_arttext&pid=S2176-94512013000500010&lng=en&tlng=en"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,10]]},"references-count":19,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2013,10]]}},"alternative-id":["S2176-94512013000500010"],"URL":"https:\/\/doi.org\/10.1590\/s2176-94512013000500010","relation":{},"ISSN":["2176-9451"],"issn-type":[{"value":"2176-9451","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,10]]}}}