{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T18:04:52Z","timestamp":1785434692005,"version":"3.56.0"},"reference-count":72,"publisher":"Begell House","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Crit Rev Biomed Eng"],"published-print":{"date-parts":[[2026]]},"abstract":"<p>This is the first review of mechanical testing or computational modeling articles that analyzed the biomechanical influence of parametrically changing scapula fracture implant (SFI) variables to optimize or characterize performance. PubMed and Embase were explored for articles using inclusion and exclusion criteria: (i) SFI articles that permutated implant variables were included, but articles using only one SFI configuration were excluded; (ii) SFIs comprising of plates (with screws), non-plate isolated \"lag\" screws, or cerclage wires were included, but anchors\/sutures, bone cements, bone grafts, or soft-tissue grafts were excluded; (iii) scapula fractures were included, but adjacent injuries of the clavicle, humerus, labrum\/capsule, ligaments\/tendons, or muscles were excluded; (iv) cadaveric, synthetic, or computer-generated scapulas were included, but other anatomic sites or biomaterials were excluded; (v) published on any date in any language. The 16 eligible articles considered different scapula regions (i.e., acromion\/spine, body, neck), SFI variables (i.e., plate geometry, plate hole type, plate position, plate number, screw angle), and engineering outcome metrics: (i) interfragmentary displacement (i.e., chance of callus growth); (ii) stresses in bones, plates, or screws (i.e., risk of failure); (iii) stresses in the bone under the plate (i.e., risk of bone \"stress shielding\"); (iv) the number of loading cycles to failure (i.e., fatigue life); (v) overall stiffness (i.e., physical flexibility); or (vi) failure strength (i.e., peak load achieved). This review advises future work for implant variables, bone characteristics, and study protocols, while suggesting SFI configurations with maximum mechanical stability.<\/p>","DOI":"10.1615\/critrevbiomedeng.2025060183","type":"journal-article","created":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T20:04:23Z","timestamp":1768507463000},"page":"47-64","source":"Crossref","is-referenced-by-count":0,"title":["Mechanical Testing and Computational Modeling of Scapula Fracture Implants: A Review"],"prefix":"10.1615","volume":"54","author":[{"given":"Radovan","family":"Zdero","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George S.","family":"Athwal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emil H.","family":"Schemitsch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pawel","family":"Brzozowski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"613","reference":[{"key":"1","unstructured":"Court-Brown CM, Clement ND. The epidemiology of musculoskeletal injury. In: Tornetta III P, Ricci WM, Ostrum RF, McQueen MM, McKee MD, Court-Brown CM, editors. Rockwood and Green'\u0080\u0099s fractures in adults. 9th ed. Philadelphia, PA: Wolters Kluwer; 2020. p. 123-\u0080\u009387."},{"key":"2","unstructured":"Bartoniek J. Scapular fractures. In: Tornetta III P, Ricci WM, Ostrum RF, McQueen MM, McKee MD, Court-Brown CM, editors. Rockwood and Green'\u0080\u0099s fractures in adults. 9th ed. Philadelphia, PA: Wolters Kluwer; 2020. p. 976-\u0080\u00931008."},{"key":"3","unstructured":"Bartonicek J, Colton C, Tucek M, Nanka O. Scapular fractures. Prague, Czechia: Maxdorf; 2022."},{"key":"4","unstructured":"Egol K, Konda S, Zuckerman J. Handbook of fractures. 7th ed. Philadelphia, PA: LippincottWilliams&Wilkins; 2025."},{"key":"5","unstructured":"Ricci WM, Mehta S, editors. Orthopaedic Knowledge update: Trauma 6. Philadelphia, PA: Wolters Kluwer; 2022."},{"key":"6","doi-asserted-by":"crossref","unstructured":"Jagodzinski M, Krettek C. Effect of mechanical stability on fracture healing-\u0080\u0094An update. Injury. 2007;38(Suppl 1):S3-\u0080\u009310.","DOI":"10.1016\/j.injury.2007.02.005"},{"key":"7","doi-asserted-by":"crossref","unstructured":"Schell H, Epari DR, Kassi JP, Bragulla H, Bail HJ, Duda GN. The course of bone healing is influenced by the initial shear fixation stability. J Orthopaed Res. 2005;23(5):1022-\u0080\u00938.","DOI":"10.1016\/j.orthres.2005.03.005"},{"key":"8","unstructured":"Bottlang M, Fitzpatrick DC, Claes L, Anderson DD. Biomechanics of fractures and fracture fixation. In: Tornetta III P, Ricci WM, Ostrum RF, McQueen MM, McKee MD, Court-Brown CM, editors. Rockwood and Green'\u0080\u0099s fractures in adults. 9th ed. Philadelphia, PA: Wolters Kluwer; 2020. p. 1-\u0080\u009342."},{"key":"9","doi-asserted-by":"crossref","unstructured":"Fouda N, Mostafa R, Saker A. Numerical study of stress shielding reduction at fractured bone using metallic and composite bone-plate models. Ain Shams Eng J. 2019;10:481-\u0080\u00938.","DOI":"10.1016\/j.asej.2018.12.005"},{"key":"10","doi-asserted-by":"crossref","unstructured":"Chow RM, Begum F, Beaupre LA, Carey JP, Adeeb S, Bouliane MJ. Proximal humeral fracture fixation: Locking plate construct  intramedullary fibular allograft. J Shoulder Elbow Surg. 2012;21(7):894-\u0080\u0093901.","DOI":"10.1016\/j.jse.2011.04.015"},{"key":"11","doi-asserted-by":"crossref","unstructured":"Amouzadeh Omrani F, Khak M, Tavakoli Darestani R, Afzal S, Baroutkoub M, Aghaalikhani M, Barati H. Treatment options and outcomes for delayed scapular anatomical neck fractures: A case report and review of the literature. J Med Case Rep. 2024;18(1):94.","DOI":"10.1186\/s13256-024-04424-3"},{"key":"12","doi-asserted-by":"crossref","unstructured":"Cole PA, Dubin JR, Freeman G. Operative techniques in the management of scapular fractures. Orthop Clin North Am. 2013;44(3):331-\u0080\u009343.","DOI":"10.1016\/j.ocl.2013.04.001"},{"key":"13","doi-asserted-by":"crossref","unstructured":"Ogawa K, Inokuchi W, Matsumura N. Physeal injuries of the coracoid process are closely associated with sports activities: A systematic review. Orthop J Sports Med. 2020;8(12):2325967120967914.","DOI":"10.1177\/2325967120967914"},{"key":"14","doi-asserted-by":"crossref","unstructured":"Sudkamp NP, Jaeger N, Bornebusch L, Maier D, Izadpanah K. Fractures of the scapula. Acta Chir Orthop Traumatol Cech. 2011;78(4):297-\u0080\u0093304.","DOI":"10.55095\/achot2011\/046"},{"key":"15","doi-asserted-by":"crossref","unstructured":"Paszicsnyek A, Jo O, Rupasinghe HS, Ackland DC, Treseder T, Pullen C, Hoy G, Ek ET, Ernstbrunner L. Factors influencing acromial and scapular spine strain after reverse total shoulder arthroplasty: A systematic review of biomechanical studies. J Clin Med. 2022;11(2):361.","DOI":"10.3390\/jcm11020361"},{"key":"16","unstructured":"Khoriati AA, Fozo ZA, Antonios T, Dimock R, Imam M, Narvani A. Traumatic anterior shoulder instability: A systematic review and proposed modern classification system. Arch Bone Jt Surg. 2024;12(9):669-\u0080\u009373."},{"key":"17","doi-asserted-by":"crossref","unstructured":"Chen JS, Novikov D, Kaplan DJ, Meislin RJ. Effect of additional sutures per suture anchor in arthroscopic Bankart repair: A review of single-loaded versus double-loaded suture anchors. Arthroscopy. 2016;32(7):1415-\u0080\u009320.","DOI":"10.1016\/j.arthro.2016.02.008"},{"key":"18","doi-asserted-by":"crossref","unstructured":"St. Jeor JD, Mason TW, Glover MA, Trasolini NA, Waterman BR. Arthroscopic suture bridge fixation for acute bony Bankart with anterior glenohumeral instability: A case report and narrative review. Ann Jt. 2024;9:16.","DOI":"10.21037\/aoj-23-46"},{"key":"19","doi-asserted-by":"crossref","unstructured":"Mei XY, Sheth U, Abouali J. Excellent functional outcomes and low complication rates following knotless arthroscopic Bankart repair: A systematic review of clinical and biomechanical studies. Arthroscopy, Sports Med Rehabil. 2021;3(3):e927-\u0080\u009338.","DOI":"10.1016\/j.asmr.2021.01.014"},{"key":"20","doi-asserted-by":"crossref","unstructured":"Yousif MJ, Bicos J. Biomechanical comparison of single-versus double-row capsulolabral repair for shoulder instability: A review. Orthop J Sports Med. 2017;5(12):2325967117742355.","DOI":"10.1177\/2325967117742355"},{"key":"21","doi-asserted-by":"crossref","unstructured":"Ergun S, Akgun U, Barber FA, Karahan M. The clinical and biomechanical performance of all-suture anchors: A systematic review. Arthroscopy, Sports Med Rehabil. 2020;2(3):e263-\u0080\u009375.","DOI":"10.1016\/j.asmr.2020.02.007"},{"key":"22","doi-asserted-by":"crossref","unstructured":"Kim JH, Koo BK, Ku KH, Kim MS. No difference in biomechanical properties of simple, horizontal mattress, and double row repair in Bankart repair: A systematic review and metaanalysis of biomechanical studies. BMC Musculoskeletal Disord. 2023;24:765.","DOI":"10.1186\/s12891-023-06864-2"},{"key":"23","doi-asserted-by":"crossref","unstructured":"Alkaduhimi H, Verweij LPE, Willigenburg NW, van Deurzen DFP, van den Bekerom MPJ. Remplissage with Bankart repair in anterior shoulder instability: A systematic review of the clinical and cadaveric literature. Arthroscopy. 2019;35(4):1257-\u0080\u009366.","DOI":"10.1016\/j.arthro.2018.10.117"},{"key":"24","doi-asserted-by":"crossref","unstructured":"Matache BA, Hurley ET, Kanakamedala AC, Jazrawi LM, Virk M, Strauss EJ, Campbell KA. Knotted versus knotless anchors for labral repair in the shoulder: A systematic review. Arthroscopy. 2021;37(4):1314-\u0080\u009321.","DOI":"10.1016\/j.arthro.2020.11.056"},{"key":"25","doi-asserted-by":"crossref","unstructured":"Lazarides AL, Duchman KR, Ledbetter L, Riboh JC, Garrigues GE. Arthroscopic remplissage or anterior shoulder instability: A systematic review of clinical and biomechanical studies. Arthroscopy. 2019;35(2):617-\u0080\u009328.","DOI":"10.1016\/j.arthro.2018.09.029"},{"key":"26","doi-asserted-by":"crossref","unstructured":"Hohmann E, Glatt V, Tetsworth K, Paschos N. Biomechanical studies for glenoid based labral repairs with suture anchors do not use consistent testing methods: A critical systematic review. Arthroscopy. 2022;38(3):1003-\u0080\u009318.","DOI":"10.1016\/j.arthro.2021.08.035"},{"key":"27","doi-asserted-by":"crossref","unstructured":"Wilke J, Krause F, Niederer D, Engeroff T, Nurnberger F, Vogt L, Banzer W. Appraising the methodological quality of cadaveric studies: Validation of the QUACS scale. J Anat. 2015;226(5):440-\u0080\u00936.","DOI":"10.1111\/joa.12292"},{"key":"28","doi-asserted-by":"crossref","unstructured":"Hollensteiner M, Sandriesser S, Rittenschober F, Hochreiter J, Augat P, Ernstbrunner L, Ortmaier R. Single or double plating for acromial type III fractures: Biomechanical comparison of load to failure and fragment motion. J Clin Med. 2022;11:3130.","DOI":"10.3390\/jcm11113130"},{"key":"29","doi-asserted-by":"crossref","unstructured":"Katthagen JC, Su\u00dfiek J, Frank A, Wermers J, Schliemann B, Raschke MJ. Double plating is associated with higher fixation strength than single plating in osteoporotic fractures of the scapular spine: A biomechanical study. Arch Orthop Trauma Surg. 2022;142(8):1859-\u0080\u009364.","DOI":"10.1007\/s00402-021-03879-z"},{"key":"30","doi-asserted-by":"crossref","unstructured":"Kicinski M, Puskas GJ, Zdravkovic V, Jost B. Osteosynthesis of type III acromial fractures with locking compression plate, lateral clavicular plate, and reconstruction plate: A biomechanical analysis of load to failure and strain distribution. J Shoulder Elbow Surg. 2018;27(11):2093-\u0080\u00938.","DOI":"10.1016\/j.jse.2018.05.031"},{"key":"31","doi-asserted-by":"crossref","unstructured":"Loomans L, Mannaerts J, Clerx S, Geuns A, Hens N, Dierickx C. Prebending of osteosynthesis plates versus screw and cerclage fixation for os acromiale or acromion fracture: The 3D technique and mechanical testing. Tech Shoulder Elbow Surg. 2018;19(2):85-\u0080\u009390.","DOI":"10.1097\/BTE.0000000000000139"},{"key":"32","doi-asserted-by":"crossref","unstructured":"Pastor MF, Nebel D, Degering A, Smith T, Karkosch R, Horstmann H, Ellwein A. Biomechanical comparison of single versus double plate osteosynthesis in acromion type III fractures. Orthop Rev (Pavia). 2024;16:88396.","DOI":"10.52965\/001c.88396"},{"key":"33","doi-asserted-by":"crossref","unstructured":"Spiegl UJA, Smith SD, Todd JN, Wijdicks CA, Millett PJ. Biomechanical evaluation of internal fixation techniques for unstable meso-type os acromiale. J Shoulder Elbow Surg. 2015;24(4):520-\u0080\u00936.","DOI":"10.1016\/j.jse.2014.09.040"},{"key":"34","doi-asserted-by":"crossref","unstructured":"Ting FSH, Lockhart JS, Axford D, Johnson JA, Langohr DG, Athwal GS. Comparing internal fixation constructs for scapular spine insufficiency fractures following reverse shoulder arthroplasty. J Shoulder Elbow Surg. 2021;30(1):172-\u0080\u00937.","DOI":"10.1016\/j.jse.2020.04.051"},{"key":"35","doi-asserted-by":"crossref","unstructured":"Acquaviva AE, Miller EI, Eisenmann DJ, Stone RT, Kraus KH. Biomechanical testing of locking and nonlocking plates in the canine scapula. J Am Anim Hosp Assoc. 2012;48(6):372-\u0080\u00938.","DOI":"10.5326\/JAAHA-MS-5804"},{"key":"36","unstructured":"Fan X, Chen Z, Cao Z, Xia Z, Chen J, Jin Z. Combined musculoskeletal multi-body dynamics and finite element investigation for customized scapular locking plate. J Xi'\u0080\u0099an Jiaotong Univ (Xi'\u0080\u0099an Jiaotong Daxue Xuebao). 2019;53(7):168-\u0080\u009376."},{"key":"37","doi-asserted-by":"crossref","unstructured":"Guo Z, Guo Y, Wang Y, Bi Y, Deng Y, Cao Y, Huang M. Finite element analysis of the treatment of a minimally invasive approach combined with a novel anatomical locking plate for scapular body fractures. J Orthop Surg Res. 2024;19(1):410.","DOI":"10.1186\/s13018-024-04905-7"},{"key":"38","unstructured":"Laugier M, Giraud N, Goin B, Moissonnier P, Viguier E. Biomechanical comparison of polyaxial locking system versus dynamic compression plate constructs in canine cadaveric scapula. Comput Methods Biomech Biomed Eng. 2021;24(Suppl 1):S125-\u0080\u00936."},{"key":"39","doi-asserted-by":"crossref","unstructured":"Mair JJ, Belkoff SM, Boudrieau RJ. An ex vivo mechanical evaluation of single versus double semitubular plate fixation of a transverse distal-third scapular osteotomy in the dog. Vet Surg. 2003;32(6):580-\u0080\u00934.","DOI":"10.1111\/j.1532-950X.2003.00580.x"},{"key":"40","doi-asserted-by":"crossref","unstructured":"Shang Y, Bi Y, Cao Y, Wang Y. Finite element analysis of titanium anatomic plate and titanium reconstructive plate for treatment of extra-articular fractures of the scapula. J Orthop Surg Res. 2023;18(1):134.","DOI":"10.1186\/s13018-023-03614-x"},{"key":"41","unstructured":"Luo L, He S, Liu J, Liang J, Yang K, FanW, Xiang F, Yang Y. Biomechanical comparison of the novel self-developed scapular neck anatomical locking plate. J Med Biomech (Yiyong Shengwu Lixue). 2023;38(5):969-\u0080\u009375."},{"key":"42","doi-asserted-by":"crossref","unstructured":"Sulkar HJ, Tashjian RZ, Chalmers PN, Henninger HB. Mechanical testing of scapular neck fracture fixation using a synthetic bone model. Clin Biomech. 2019;61:64-\u0080\u00939.","DOI":"10.1016\/j.clinbiomech.2018.11.007"},{"key":"43","doi-asserted-by":"crossref","unstructured":"Xiang F, Xiao Y, Wei D, Tan X, He S, Luo L, Yang Y. Finite element analysis of a novel anatomical locking plate for scapular neck fracture. J Orthop Surg Res. 2023;18(1): 262.","DOI":"10.1186\/s13018-023-03743-3"},{"key":"44","doi-asserted-by":"crossref","unstructured":"Islam S, Dembowski M, Schemitsch EH, Bougherara H, Bagheri ZS, Zdero R. Biomechanical design of a new proximal humerus fracture plate using alternative materials. Int J Numer Methods Biomed Eng. 2024:e3868.","DOI":"10.1002\/cnm.3868"},{"key":"45","doi-asserted-by":"crossref","unstructured":"Schliemann B, Risse N, Frank A, Muller M, Michel P, Raschke MJ, Katthagen JC. Screws with larger core diameter and lower thread pitch increase the stability of locked plating in osteoporotic proximal humeral fractures. Clin Biomech. 2019;63:21-\u0080\u00936.","DOI":"10.1016\/j.clinbiomech.2019.02.006"},{"key":"46","doi-asserted-by":"crossref","unstructured":"Mardian S, Schaser KD, Duda GN, Heyland M. Working length of locking plates determines interfragmentary movement in distal femur fractures under physiological loading. Clin Biomech. 2015;30(4):391-\u0080\u00936.","DOI":"10.1016\/j.clinbiomech.2015.02.006"},{"key":"47","unstructured":"Acumed. Hillsboro, OR, USA. www.acumed.net"},{"key":"48","unstructured":"Kangli Orthopaedics Instrument. Zhangjiagang, China. https:\/\/kanglimed.com."},{"key":"49","unstructured":"TST Medical Devices, Istanbul, Turkey. www.tstsan.com."},{"key":"50","doi-asserted-by":"crossref","unstructured":"Ma L, Zhou Y, Zhu Y, Lin Z, Chen L, Zhang Y, Xia H, Mao C. 3D printed personalized titanium plates improve clinical outcome in microwave ablation of bone tumors around the knee. Sci Rep. 2017;7:7626.","DOI":"10.1038\/s41598-017-07243-3"},{"key":"51","doi-asserted-by":"crossref","unstructured":"Zheng Y, Li J, Tam AY, Lee TT, Peng Y, Cheung JC, Wong DW, Ni M. Finite element modeling of clavicle fracture fixations: A systematic scoping review. Med Biol Eng Comput. 2025;63(6):1585-\u0080\u00931607.","DOI":"10.1007\/s11517-025-03294-1"},{"key":"52","doi-asserted-by":"crossref","unstructured":"Meinberg EG, Agel J, Roberts CS, Karam MD, Kellam JF. Fracture and dislocation classification compendium-\u0080\u00932018. J Orthop Trauma. 2018;32(1):S1-\u0080\u0093170.","DOI":"10.1097\/BOT.0000000000001063"},{"key":"53","doi-asserted-by":"crossref","unstructured":"He Y, He J, Wang F, Zhou D, Wang Y, Wang B, Xu S. Application of additional medial plate in treatment of proximal humeral fractures with unstable medial column: A finite element study and clinical practice. Medicine (Baltimore). 2015;94(41):e1775.","DOI":"10.1097\/MD.0000000000001775"},{"key":"54","doi-asserted-by":"crossref","unstructured":"Dickenson RP, Hutton WC, Stott JRR. The mechanical properties of bone in osteoporosis. J Bone Jt Surg (Br Vol). 1981;63(2):233-\u0080\u00938.","DOI":"10.1302\/0301-620X.63B2.7217148"},{"key":"55","doi-asserted-by":"crossref","unstructured":"Zdero R. Practical Career Advice for engineers: Personal letters from an experienced engineer to students and new engineers. Boca Raton FL: CRC Press; 2022.","DOI":"10.1201\/9781003193081"},{"key":"56","unstructured":"ASTM F382. Standard specification and test method for metallic bone plates. American Society for Testing and Materials (ASTM International), West Conshohocken, PA."},{"key":"57","doi-asserted-by":"crossref","unstructured":"Zdero R. Experimental methods in orthopaedic biomechanics. New York, NY: Academic Press; 2017.","DOI":"10.1016\/B978-0-12-803802-4.02001-1"},{"key":"58","doi-asserted-by":"crossref","unstructured":"Zdero R, Brzozowski P, Schemitsch EH. Biomechanical properties of artificial bones made by Sawbones: A review. Med Eng Phys. 2023;118:104017.","DOI":"10.1016\/j.medengphy.2023.104017"},{"key":"59","doi-asserted-by":"crossref","unstructured":"Dhason R, Roy S, Datta S. Metal and composite bone plates for B1 periprosthetic femoral fracture in healthy and osteoporotic condition: A comparative biomechanical study. Int J Artif Organs. 2022;45(8):704-\u0080\u009314.","DOI":"10.1177\/03913988221108752"},{"key":"60","doi-asserted-by":"crossref","unstructured":"Gupta S, van der Helm FCT, Sterk JC, van Keulen F, Kaptein BL. Development and experimental validation of a three-dimensional finite element model of the human scapula. Proc Inst Mech Eng Part H: J Eng Med. 2004;218(2):127-\u0080\u009342.","DOI":"10.1243\/095441104322984022"},{"key":"61","doi-asserted-by":"crossref","unstructured":"Gupta S, Van Der Helm FCT. Load transfer across the scapula during humeral abduction. J Biomech. 2004; 37(7):1001-\u0080\u00939.","DOI":"10.1016\/j.jbiomech.2003.11.025"},{"key":"62","doi-asserted-by":"crossref","unstructured":"Axford DT, Potra R, Appleyard R, Tomka J, Arenas-Miquelez A, Hollo D, Raniga S, Ferreira LM. A biomechanical investigation of the surface strains on the acromion and scapular spine during simulated ex-vivo arm motion. J Biomech. 2025;183:112588.","DOI":"10.1016\/j.jbiomech.2025.112588"},{"key":"63","unstructured":"Innocenti B, Galbusera F, editors. Human Orthopaedic biomechanics: Fundamentals, devices, and applications. London, UK: Academic Press; 2022."},{"key":"64","doi-asserted-by":"crossref","unstructured":"Van Rietbergen B, Huiskes R, Eckstein F, Ruegsegger P. Trabecular bone tissue strains in the healthy and osteoporotic human femur. J Bone Miner Res. 2003;18(10):1781-\u0080\u00938.","DOI":"10.1359\/jbmr.2003.18.10.1781"},{"key":"65","doi-asserted-by":"crossref","unstructured":"Islam S, Gide K, Schemitsch EH, Bougherara H, Zdero R, Bagheri ZS. Biomechanical effects of different loads and constraints on finite element modeling of the humerus. Comput Methods Biomech Biomed Eng. 2023;28(5):601-\u0080\u009313.","DOI":"10.1080\/10255842.2023.2298371"},{"key":"66","doi-asserted-by":"crossref","unstructured":"MacLeod AR, Pankaj P, Simpson AHRW. Does screwbone interface modelling matter in finite element analyses? J Biomech. 2012;45(9):1712-\u0080\u00936.","DOI":"10.1016\/j.jbiomech.2012.04.008"},{"key":"67","doi-asserted-by":"crossref","unstructured":"Schemitsch EH, Bhandari M, Boden SD, Bourne RB, Bozic KJ, Jacobs JJ, Zdero R. The evidence-based approach in bringing new orthopaedic devices to market. J Bone Jt Surg (Am Vol), 2010;92(4):1030-\u0080\u00937.","DOI":"10.2106\/JBJS.H.01532"},{"key":"68","doi-asserted-by":"crossref","unstructured":"Zdero R, Brzozowski P, Schemitsch EH, Yang I. The design process for orthopaedic implants: An introduction. Bone Jt Res, 2026;15(5):577-\u0080\u009382.","DOI":"10.1302\/2046-3758.155.BJR-2025-0267.R3"},{"key":"69","doi-asserted-by":"crossref","unstructured":"Zhang J, Li Y, Bi Y, Chu X, Cao Y. A comparative analysis of titanium anatomic plate and titanium reconstructive plate for treatment of extra-articular fractures of the scapula (Miller types IIb, IIc, and IV). J Shoulder Elbow Surg. 2022;31(6):1175-\u0080\u009383","DOI":"10.1016\/j.jse.2021.12.008"},{"key":"70","doi-asserted-by":"crossref","unstructured":"Konstantinidis GA, Smithers T, Hong TF. Postoperative results of Ogawa type IIB meta-acromion fracture fixation with a 90\u00b1 twisted reconstruction plate. Arch Orthop Trauma Surg. 2020;140(9):1181-\u0080\u00939.","DOI":"10.1007\/s00402-020-03351-4"},{"key":"71","doi-asserted-by":"crossref","unstructured":"Mayo KA, Benirschke SK, Mast JW. Displaced fractures of the glenoid fossa: Results of open reduction and internal fixation. Clin Orthop Relat Res. 1998;347:122-\u0080\u009330.","DOI":"10.1097\/00003086-199802000-00015"},{"key":"72","doi-asserted-by":"crossref","unstructured":"Gautier E, Sommer C. Guidelines for the clinical application of the LCP. Injury. 2003;34(Suppl 2):SB63-\u0080\u009376.","DOI":"10.1016\/j.injury.2003.09.026"}],"container-title":["Critical Reviews in Biomedical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.dl.begellhouse.com\/download\/article\/03b775472398e784\/CRB5403(3)-60183.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T17:54:41Z","timestamp":1785434081000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.dl.begellhouse.com\/journals\/4b27cbfc562e21b8,10bc98d85f01d070,03b775472398e784.html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026]]},"references-count":72,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1615\/critrevbiomedeng.2025060183","relation":{},"ISSN":["0278-940X"],"issn-type":[{"value":"0278-940X","type":"print"}],"subject":[],"published":{"date-parts":[[2026]]}}}