{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T12:15:26Z","timestamp":1777032926300,"version":"3.51.4"},"reference-count":28,"publisher":"Begell House","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Long Term Eff Med Implants"],"published-print":{"date-parts":[[2026]]},"abstract":"<p>Purpose of this study was to evaluate the distribution of bone tension around single implants with different &lt;i&gt;\u0421&lt;\/i&gt;\/I ratio (1.5:1, 1.75:1, 2:1) according to the von Mises criterion. Stress analysis was performed using Invesalius 3.0, Rhinoceros 3D 4.0 software. Three 3D models of the mandibular segment of the bone block were developed: model A, a short implant (6 mm) C\/I -1.5:1; model B, a short implant (6 mm) C\/I -1.75:1; model C, a short implant (6 mm) C\/I -2:1. The results were evaluated: the cumulative frequency of implant engraftment, MBL changes around the implant, follow up for 5 years. Under axial load, the highest stresses were concentrated at the abutment\/implant junctions, the highest stresses were 67.94 MPa C\/I -1.5:1, 68.09 MPa C\/I -1.75:1 and 68.24 MPa C\/ I -2:1, respectively. The results of the current study, indicate the increase in crown height showed little difference in load at the crown\/implant interface with crown\/implant ratios of 1.5:1, 1.75:1 and 2:1. &lt;i&gt;In vivo&lt;\/i&gt; finite element analysis (FEA) study showed that short implantats are successful regardless the C\/I ratio. Use of shorts implants for prosthetic rehabilitation can be considered favorable and well substantiated.<\/p>","DOI":"10.1615\/jlongtermeffmedimplants.2025055634","type":"journal-article","created":{"date-parts":[[2025,8,19]],"date-time":"2025-08-19T20:12:12Z","timestamp":1755634332000},"page":"31-36","source":"Crossref","is-referenced-by-count":1,"title":["Effect of Crown-to-Implant Ratio of Short Implants on Peri-Implant Stress: A Finite Element Analysis"],"prefix":"10.1615","volume":"36","author":[{"given":"Naira","family":"Ghambaryan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gagik","family":"Hakobyan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"613","reference":[{"key":"2","unstructured":"Romeo E, Bivio A, Mosca D, Scanferla M, Ghisolfi M, Storelli S. The use of short dental implants in clinical practice: Literature review. Minerva Stomatol. 2010;59(1-2):23-31."},{"key":"3","doi-asserted-by":"crossref","unstructured":"Nedir R, Bischof M, Briaux JM, Beyer S, Szmukler-Mon-cler S, Bernard JP. A 7-year life table analysis from a prospective study on ITI implants with special emphasis on the use of short implants. Results from a private practice. Clin Oral Implants Res. 2004;15(2):150-7.","DOI":"10.1111\/j.1600-0501.2004.00978.x"},{"key":"4","doi-asserted-by":"crossref","unstructured":"Karthikeyan I, Desai SR, Singh R. Short implants: A systematic review. J Indian Soc Periodontol. 2012;16(3):302-12.","DOI":"10.4103\/0972-124X.100901"},{"key":"5","doi-asserted-by":"crossref","unstructured":"Papaspyridakos P, De Souza A, Vazouras K, Gholami H, Pagni S, Weber HP. Survival rates of short dental implants (\u00e2\u0089\u00a4 6 mm) compared with implants longer than 6 mm in posterior jaw areas: A meta-analysis. Clin Oral Implants Res. 2018;29:8-20.","DOI":"10.1111\/clr.13289"},{"key":"6","doi-asserted-by":"crossref","unstructured":"Cornacchia GM, Nunes E, Cosso MG, de Souza LN, Ze-n\u00f3bio EG. Extra short 4 mm implants used to rehabilitation of atrophic posterior mandible. A serial case reports. J Clin Exp Dent. 2020;12(5):e519.","DOI":"10.4317\/jced.56654"},{"key":"7","doi-asserted-by":"crossref","unstructured":"Blanes RJ. To what extent does the crown-implant ratio affect the survival and complications of implant-supported reconstructions? A systematic review. Clin Oral Implants Res. 2009;20:67-72.","DOI":"10.1111\/j.1600-0501.2009.01762.x"},{"key":"8","doi-asserted-by":"crossref","unstructured":"Mangano F, Frezzato I, Frezzato A, Veronesi G, Mortel-laro C, Mangano C. The effect of crown-to-implant ratio on the clinical performance of extra-short locking-taper implants. J Craniofac Surg. 2016;27(3):675-81.","DOI":"10.1097\/SCS.0000000000002562"},{"key":"9","doi-asserted-by":"crossref","unstructured":"Birdi H, Schulte J, Kovacs A, Weed M, Chuang SK. Crown-to-implant ratios of short-length implants. J Oral Implantol. 2010;36(6):425-33.","DOI":"10.1563\/AAID-JOI-D-09-00071"},{"key":"10","doi-asserted-by":"crossref","unstructured":"Bulaqi HA, Mashhadi MM, Safari H, Samandari MM, Geramipanah F. Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: A finite element analysis. J Prosthet Dent. 2015;113:548-57.","DOI":"10.1016\/j.prosdent.2014.11.007"},{"key":"11","doi-asserted-by":"crossref","unstructured":"Ercal P, Taysi AE, Ayvalioglu DC, Eren MM, Sismanoglu S. Impact of peri-implant bone resorption, prosthetic materials, and crown to implant ratio on the stress distribution of short implants: A finite element analysis. Med Biol Eng Comput. 2021;59(4):813-24.","DOI":"10.1007\/s11517-021-02342-w"},{"key":"12","doi-asserted-by":"crossref","unstructured":"Reddy MS, Sundram R, Eid Abdemagyd HA. Application of finite element model in implant dentistry: A systematic review. J Pharm Bioallied Sci. 2019;11(Suppl 2):S85-91.","DOI":"10.4103\/JPBS.JPBS_296_18"},{"key":"13","doi-asserted-by":"crossref","unstructured":"Al-Kordy NM, Al-Saadi MH. Finite element study of stress distribution with tooth-supported mandibular overdenture retained by ball attachments or resilient telescopic crowns. European J Dent. 2023;17(02):539-47.","DOI":"10.1055\/s-0042-1749363"},{"key":"14","doi-asserted-by":"crossref","unstructured":"Pesqueira AA, Goiato MC, Gennari Filho H, Monteiro DR, Dos Santos DM, Haddad MF, Pellizzer EP. Use of stress analysis methods to evaluate the biomechanics of oral rehabilitation with implants. J Oral Implantol. 2014;40(2):217-28.","DOI":"10.1563\/AAID-JOI-D-11-00066"},{"key":"15","doi-asserted-by":"crossref","unstructured":"Liu WK, Li S, Park HS. Eighty years of the finite element method: Birth, evolution, and future. Arch Computat Methods Eng. 2022;29:4431-53.","DOI":"10.1007\/s11831-022-09740-9"},{"key":"16","doi-asserted-by":"crossref","unstructured":"Esfahrood ZR, Ahmadi L, Karami E, Asghari S. Short dental implants in the posterior maxilla: A review of the literature. J Korean Assoc Oral Maxillofac Surg. 2017;43(2):70-6.","DOI":"10.5125\/jkaoms.2017.43.2.70"},{"key":"17","doi-asserted-by":"crossref","unstructured":"Tolentino da Rosa de Souza P, Binhame Albini Martini M, Reis Azevedo-Alanis L. Do short implants have similar survival rates compared to standard implants in posterior single crown?: A systematic review and meta-analysis. Clin Implant Dent Relat Res. 2018;20(5): 890-901.","DOI":"10.1111\/cid.12634"},{"key":"18","doi-asserted-by":"crossref","unstructured":"Ravid\u00e0 A, Wang IC, Barootchi S, Askar H, Tavelli L, Gargallo-Albiol J, Wang HL. Meta-analysis of randomized clinical trials comparing clinical and patient-reported outcomes between extra-short (\u00e2\u0089\u00a4 6 mm) and longer (\u00e2\u0089\u00a5 10 mm) implants. J Clin Periodontol. 2019;46(1):118-42.","DOI":"10.1111\/jcpe.13026"},{"key":"19","doi-asserted-by":"crossref","unstructured":"Sadowsky SJ. Occlusal overload with dental implants: A review. Int J Implant Dent. 2019;5(1):29.","DOI":"10.1186\/s40729-019-0180-8"},{"key":"20","doi-asserted-by":"crossref","unstructured":"Moraes SL, Verri FR, Santiago Jr JF, Almeida DA, de Mello CC, Pellizzer EP. A 3-D finite element study of the influence of crown-implant ratio on stress distribution. Braz Dent J. 2013;24:635-41.","DOI":"10.1590\/0103-6440201302287"},{"key":"21","doi-asserted-by":"crossref","unstructured":"Faria Almeida DA, Pellizzer EP, Verri FR, Santiago Jr JF, Carvalho PS. Influence of tapered and external hexagon connections on bone stresses around tilted dental implants: Three-dimensional finite element method with statistical analysis. J Periodontol. 2014;85:261-9","DOI":"10.1902\/jop.2013.120713"},{"key":"22","doi-asserted-by":"crossref","unstructured":"Araki H, Nakano T, Ono S, Yatani H. Three-dimensional finite element analysis of extra short implants focusing on implant designs and materials. Int J Implant Dent. 2020;6(1):5.","DOI":"10.1186\/s40729-019-0202-6"},{"key":"23","doi-asserted-by":"crossref","unstructured":"Zupancic Cepic L, Frank M, Reisinger A, Pahr D, Zechner W, Schedle A. Biomechanical finite element analysis of short-implant-supported, 3-unit, fixed CAD\/CAM prostheses in the posterior mandible. Int J Implant Dent. 2022;8(1):8.","DOI":"10.1186\/s40729-022-00404-8"},{"key":"24","unstructured":"Tawil G, Aboujaoude N, Younan R. Influence of prosthetic parameters on the survival and complication rates of short implants. Int J Oral Maxillofac Implants. 2006;21:275-82."},{"key":"25","doi-asserted-by":"crossref","unstructured":"Schulte J, Flores AM, Weed M. Crown-to-implant ratios of single tooth implant supported restorations. J Prosthet Dent. 2007;98:1-5.","DOI":"10.1016\/S0022-3913(07)60031-6"},{"key":"26","unstructured":"Ghambaryan N, Jilavyan A, Khachatryan G, Mathevosyan D, Tunyan G, Hakobyan G. Evaluation of the survival rate of short implants placed in the posterior atrophic mandible: 5-year clinical study. Quintessence Int. 2022;53(8):690-6."},{"key":"27","doi-asserted-by":"crossref","unstructured":"Ghambaryan N. Clinical effectiveness of guided implant surgery in patients with fully edentulous patients atrophy of the lower jaw. Bulletin Stomatol Maxillofac Surg. 2023;19(3):76-84.","DOI":"10.58240\/1829006X-2023.19.3-76"},{"key":"28","doi-asserted-by":"crossref","unstructured":"Ghambaryan N, Yessayan L, Hakobyan G. Long-term effectiveness of UV functionalised short (\u00e2\u0089\u00a4 6 mm) dental implants placed in the posterior segments of the atrophied maxilla: Controlled case series. Odontology. 2024;112(4):1316-25.","DOI":"10.1007\/s10266-024-00926-0"},{"key":"29","doi-asserted-by":"crossref","unstructured":"Ghambaryan N, Bollen C, Hakobyan G. Influence of crown-implant ratio on photofuntcionalized short implants success rates: 5 year follow-up prospective study. Oral Maxillofac Surg. 2025;29(1):100.","DOI":"10.1007\/s10006-025-01395-7"}],"container-title":["Journal of Long-Term Effects of Medical Implants"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.dl.begellhouse.com\/download\/article\/33683ec824bd6e11\/JLT-55634.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T19:16:57Z","timestamp":1771528617000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.dl.begellhouse.com\/journals\/1bef42082d7a0fdf,2393d5e40ec8bbbb,33683ec824bd6e11.html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026]]},"references-count":28,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1615\/jlongtermeffmedimplants.2025055634","relation":{},"ISSN":["1050-6934"],"issn-type":[{"value":"1050-6934","type":"print"}],"subject":[],"published":{"date-parts":[[2026]]}}}