{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,20]],"date-time":"2026-11-20T06:43:42Z","timestamp":1795157022920,"version":"4.10.3"},"reference-count":20,"publisher":"Begell House","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Long Term Eff Med Implants"],"published-print":{"date-parts":[[2026]]},"abstract":"<p>The purpose of this study was to compare outcomes following open reduction and internal fixation (ORIF) of proximal humerus fractures with Zimmer Biomet and DePuy Synthes plating systems. This was a retrospective review of patients who underwent proximal humerus fracture fixation utilizing Zimmer Biomet or DePuy Synthes plating systems between June 2016 and February 2023. Patients without postoperative follow-up were excluded. Complication rates were compared between the two cohorts using chi-square and two-tailed &lt;i&gt;t&lt;\/i&gt;-tests for categorical and continuous variables, respectively. A total of 86 patients were identified for inclusion and eight were excluded for inadequate follow up. Statistical analysis comprised a total of 78 patients, 41 who underwent ORIF with a Zimmer Biomet implant, and 37 who underwent ORIF with a DePuy Synthes implant. The overall complication rate was 4.88&amp;#37; (&lt;i&gt;n&lt;\/i&gt; = 2) in the Zimmer Biomet cohort and 13.5&amp;#37; (&lt;i&gt;n&lt;\/i&gt; = 5) in the DePuy Synthes cohort (&lt;i&gt;P&lt;\/i&gt; &amp;#62; 0.05). Both Zimmer Biomet patients required revision surgery, compared with two out of five patients in the DePuy-Synthes group. There were no statistically significant differences in rates of avascular necrosis, impingement, malunion, or fixation failure between the two cohorts. Overall complication rate and need for revision surgery were similar between patients who underwent fixation with the Zimmer Biomet or DePuy Synthes plating systems. Our findings support selection of either plating system based on surgeon preference and equipment availability as neither demonstrated clinical superiority.<\/p>","DOI":"10.1615\/jlongtermeffmedimplants.2025059687","type":"journal-article","created":{"date-parts":[[2025,6,19]],"date-time":"2025-06-19T14:40:25Z","timestamp":1750344025000},"page":"1-7","source":"Crossref","is-referenced-by-count":1,"title":["Low Revision Rates with Locking Plate Fixation of Proximal Humerus Fractures: A Comparison of Two Implant Systems"],"prefix":"10.1615","volume":"36","author":[{"given":"Sarah","family":"Whitaker","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yekeen","family":"Abu-Shiraz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suhas","family":"Velichala","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aadi","family":"Sharma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew","family":"Smith","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Josh","family":"Setliff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Satalich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul","family":"Kiritsis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jennifer L.","family":"Vanderbeck","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Doug","family":"Boardman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"613","reference":[{"issue":"11","key":"2","doi-asserted-by":"crossref","first-page":"2072","DOI":"10.1016\/j.jse.2019.03.034","article-title":"Nationwide trends in management of proximal humeral fractures: An analysis of 77,966 cases from 2008 to 2017","volume":"28","author":"Mclean A.S.","year":"2008","journal-title":"J Shoulder Elbow Surg"},{"issue":"8","key":"3","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.injury.2006.04.130","article-title":"Epidemiology of adult fractures: A review","volume":"37","author":"Court-Brown C.M.","year":"2006","journal-title":"Injury"},{"issue":"10","key":"4","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.1001\/jama.2015.1629","article-title":"Surgical vs. nonsurgical treatment of adults with displaced fractures of the proximal humerus: The PROFHER randomized clinical trial","volume":"313","author":"Rangan A.","year":"2015","journal-title":"JAMA"},{"issue":"6","key":"5","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.2106\/JBJS.H.00006","article-title":"Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study","volume":"91","author":"Sudkamp N.","year":"2009","journal-title":"J Bone Joint Surg Am"},{"issue":"8","key":"6","doi-asserted-by":"crossref","first-page":"1689","DOI":"10.1016\/j.jse.2019.11.026","article-title":"Locking plate fixation of proximal humerus fractures in patients older than 60 years continues to be associated with a high complication rate","volume":"29","author":"Barlow J.D.","year":"2020","journal-title":"J Shoulder Elbow Surg"},{"issue":"3","key":"7","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1097\/BOT.0b013e3181920e5b","article-title":"Open reduction and internal fixation of proximal humerus fractures using a proximal humeral locked plate: A prospective multicenter analysis","volume":"23","author":"Brunner F.","year":"2009","journal-title":"J Orthop Trauma"},{"issue":"4","key":"8","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/j.clinbiomech.2010.01.009","article-title":"Proximal humerus fracture rotational stability after fixation using a locking plate or a fixed-angle locked nail: The role of implant stiffness","volume":"25","author":"Foruria A.M.","year":"2010","journal-title":"Clin Biomech"},{"issue":"2","key":"9","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/j.clinbiomech.2006.08.009","article-title":"Locked vs. unlocked plate osteosynthesis of the proximal humerus-A biomechanical study","volume":"22","author":"Seide K.","year":"2007","journal-title":"Clin Biomech"},{"issue":"11","key":"10","doi-asserted-by":"crossref","first-page":"523","DOI":"10.5435\/JAAOS-D-20-00558","article-title":"Principles of locking plate fixation of proximal humerus fractures","volume":"29","author":"Omid R.","year":"2021","journal-title":"J Am Acad Orthop Surg"},{"issue":"7S","key":"11","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.jse.2019.10.012","article-title":"Acute surgical management of proximal humerus fractures: ORIF vs. hemiarthroplasty vs. reverse shoulder arthroplasty","volume":"29","author":"Yahuaca B.I.","year":"2020","journal-title":"J Shoulder Elbow Surg"},{"issue":"6","key":"12","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.2106\/00004623-197052060-00001","article-title":"Displaced proximal humeral fractures. I. Classification and evaluation","volume":"52","author":"Neer C.S.","year":"1970","journal-title":"J Bone Joint Surg Am"},{"issue":"10","key":"13","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/j.jse.2016.02.015","article-title":"Complications of locked plating for proximal humeral fractures-Are we getting any better?","volume":"25","author":"Haasters F.","year":"2016","journal-title":"J Shoulder Elbow Surg"},{"issue":"4","key":"14","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/j.injury.2010.11.058","article-title":"A systematic review of locking plate fixation of proximal humerus fractures","volume":"42","author":"Sproul R.C.","year":"2011","journal-title":"Injury"},{"issue":"9","key":"15","doi-asserted-by":"crossref","first-page":"1796","DOI":"10.1016\/j.jse.2020.01.073","article-title":"Surgical treatment of complex proximal humeral fractures in elderly patients: A matched-pair analysis of angular-stable plating vs. reverse shoulder arthroplasty","volume":"29","author":"Klug A.","year":"2020","journal-title":"J Shoulder Elbow Surg"},{"issue":"9","key":"16","doi-asserted-by":"crossref","first-page":"1674","DOI":"10.1016\/j.jse.2019.02.017","article-title":"Complications after surgical treatment of proximal humerus fractures in the elderly-an analysis of complication patterns and risk factors for reverse shoulder arthroplasty and angular-stable plating","volume":"28","author":"Klug A.","year":"2019","journal-title":"J Shoulder Elbow Surg"},{"issue":"11","key":"17","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1097\/BOT.0000000000000371","article-title":"Geometry of proximal humerus locking plates","volume":"29","author":"McDonald E.","year":"2015","journal-title":"J Orthop Trauma"},{"issue":"12","key":"18","doi-asserted-by":"crossref","first-page":"2159","DOI":"10.1016\/j.jse.2018.05.033","article-title":"The outcome of surgical management of proximal humeral fractures using locking plates: Comparison between locking plates with different geometry","volume":"27","author":"Chen J.L.","year":"2018","journal-title":"J Shoulder Elbow Surg"},{"key":"19","doi-asserted-by":"crossref","first-page":"53","DOI":"10.2174\/1874325001812010053","article-title":"Early results of the ALPS proximal humerus locking plate","volume":"12","author":"Argyropoulos M.","year":"2018","journal-title":"Open Orthop J"},{"key":"20","doi-asserted-by":"crossref","DOI":"10.1016\/j.injury.2014.10.022","article-title":"Fractures and fracture-dislocations of the proximal humerus: A retrospective analysis of 82 cases treated with the Philos(reg) locking plate","volume":"45","author":"Erasmo R.","year":"2014","journal-title":"Injury"},{"issue":"1","key":"21","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1007\/s00590-010-0655-z","article-title":"Results of 131 consecutive operated patients with a displaced proximal humerus fracture: An analysis with more than two years follow-up","volume":"21","author":"Faraj D.","year":"2011","journal-title":"Eur J Orthop Surg Traumatol"}],"container-title":["Journal of Long-Term Effects of Medical Implants"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.dl.begellhouse.com\/download\/article\/0dc5568466252fdd\/JLT-59687.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T19:16:46Z","timestamp":1771528606000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.dl.begellhouse.com\/journals\/1bef42082d7a0fdf,2393d5e40ec8bbbb,0dc5568466252fdd.html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1615\/jlongtermeffmedimplants.2025059687","relation":{},"ISSN":["1050-6934"],"issn-type":[{"value":"1050-6934","type":"print"}],"subject":[],"published":{"date-parts":[[2026]]}}}