{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T07:33:34Z","timestamp":1763019214111,"version":"3.45.0"},"reference-count":25,"publisher":"Begell House","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Long Term Eff Med Implants"],"published-print":{"date-parts":[[2025]]},"abstract":"<p>Osseointegration is related to the stability of the screw and influences the success rate of implant-supported prosthetic rehabilitation, as it promotes natural healing and effective bone formation, facilitating the preservation of the implant in the recipient site. Factors such as surgical technique, insertion torque, the type of recipient bone, and the macro- and microstructure of the implant can affect screw stability. The objective of this study is to analyze &lt;i&gt;in vivo&lt;\/i&gt; the influence of insertion torque, recipient bone type, and peri-implant bone loss on the implant stability quotient (ISQ) values of cylindrical implants with external hexagon (EH) and Morse taper (MT) connections, featuring a new surface treatment called referenced acid etching (RAE). A total of 40 implants were placed in edentulous areas following predefined inclusion and exclusion criteria. Immediately after implant placement (t0), insertion torque, resonance frequency, digital periapical radiographs, and peri-implant evaluation were recorded. Resonance frequency analysis, periapical radiographs, and peri-implant evaluations were repeated after osseointegration (t1) and 180 d after rehabilitation (t2). The data obtained were statistically analyzed using specific tests for each type of analysis, with a significance level of 5&amp;#37;. Regarding the ISQ value at t1, it resulted in a high value, with a significant reduction at t2, for both types of connection, there was bone resorption for the HE and bone gain for the MT. The installation of the implants up to 180 d of prosthesis functionality, stability, bone gain or loss and type of bone, presented clinically acceptable conditions for all connections studied.<\/p>","DOI":"10.1615\/jlongtermeffmedimplants.2025060463","type":"journal-article","created":{"date-parts":[[2025,7,18]],"date-time":"2025-07-18T16:31:38Z","timestamp":1752856298000},"page":"51-61","source":"Crossref","is-referenced-by-count":0,"title":["Influence of Torque Type and Bone Loss on the Stability Quotient of Two Implants with Prostheses"],"prefix":"10.1615","volume":"35","author":[{"given":"Jo\u00e3o Paulo do Vale","family":"Souza","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniela Micheline","family":"dos Santos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cl\u00f3vis Lamartine de Moraes Melo","family":"Neto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lucas Tavares","family":"Piacenza","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emily Vivianne Freitas","family":"da Silva","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lisiane Cristina","family":"Bannwart","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marcelo Coelho","family":"Goiato","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"613","reference":[{"key":"2","doi-asserted-by":"crossref","unstructured":"Goiato MC, Torcato LB, Dos Santos DM, Moreno A, Antenucci RM, de Carvalho Dekon SF. Quality of life and satisfaction of patients wearing implant-supported fixed partial denture: A cross-sectional survey of patients from Ara\u00e7atuba city, Brazil. Clin Oral Implants Res. 2015;26:701-8.","DOI":"10.1111\/clr.12372"},{"key":"3","doi-asserted-by":"crossref","unstructured":"Farr\u00e9-Pag\u00e9s N, Aug\u00e9-Castro ML, Alaejos-Algarra F, Mareque-Bueno J, Ferr\u00e9s-Padr\u00f3 E, Hern\u00e1ndez-Alfaro F. Relation between bone density and primary implant stability. Med Oral Patol Oral Cir Bucal. 2011;16:62-7.","DOI":"10.4317\/medoral.16.e62"},{"key":"4","doi-asserted-by":"crossref","unstructured":"Mathieu V, Vayron R, Richard G, Lambert G, Naili S, Meningaud JP, Haiat G. Biomechanical determinants of the stability of dental implants: Influence of the bone-implant interface properties. J Biomech. 2014;47:3-13.","DOI":"10.1016\/j.jbiomech.2013.09.021"},{"key":"5","doi-asserted-by":"crossref","unstructured":"Zonfrillo G, Matteoli S, Ciabattini A, Dolfi M, Lorenzini L, Corvi A. Analysis and comparison of clutch techniques of two dental implants. J Mech Behav Biomed Mater. 2014;34:1-7.","DOI":"10.1016\/j.jmbbm.2014.01.017"},{"key":"6","doi-asserted-by":"crossref","unstructured":"Toyoshima T, Tanaka H, Ayukawa Y, Howashi M, Masuzaki T, Kiyosue T, Koyano K, Nakamura S. Primary stability of a hybrid implant compared with tapered and cylindrical implants in an ex vivo model. Clin Implant Dent Relat Res. 2015;17:950-6.","DOI":"10.1111\/cid.12205"},{"key":"7","doi-asserted-by":"crossref","unstructured":"Coutant JC, Seguela V, Hauret L, Caix P, Ella B. Assessment of the correlation between implant stability and bone density by computed tomography and resonance frequency analysis in fresh cadavers. Int J Oral Maxillofac Implants. 2014;29:1264-70.","DOI":"10.11607\/jomi.2607"},{"key":"8","doi-asserted-by":"crossref","unstructured":"Jeong MA, Jung MK, Kim SG, Oh JS. Implant stability measurements in the long-term follow-up of dentis implants: A retrospective study with periotest. Implant Dent. 2015;24:263-6.","DOI":"10.1097\/ID.0000000000000239"},{"key":"9","doi-asserted-by":"crossref","unstructured":"Gehrke SA, Marin GW. Biomechanical evaluation of dental implants with three different designs: Removal torque and resonance frequency analysis in rabbits. Ann Anat. 2015;199:30-5.","DOI":"10.1016\/j.aanat.2014.07.009"},{"key":"10","doi-asserted-by":"crossref","unstructured":"Nedir, R, Bischof M, Szmukler-Moncler S, Bernard JP, Samson J. Predicting osseointegration by means of implant primary stability. Clin Oral Implants Res. 2004;15:520-8.","DOI":"10.1111\/j.1600-0501.2004.01059.x"},{"key":"11","doi-asserted-by":"crossref","unstructured":"Xiao JR, Li YQ, Guan SM, Kong L, Liu B, Li D. Effects of lateral cortical anchorage on the primary stability of implants subjected to controlled loads: An in vitro study. Br J Oral Maxillofac Surg. 2012;50:161-5.","DOI":"10.1016\/j.bjoms.2011.01.010"},{"key":"12","doi-asserted-by":"crossref","unstructured":"Lozano-Carrascal N, Salomo-Coll O, Gilabert-Cerda M, Farre-Pages N, Gargallo-Albiol J, Hernandez-Alfaro F. Effect of implant macro-design on pimary stability: A prospective clinical study. Med Oral Patol Oral Cir Bucal. 2016;21:214-21.","DOI":"10.4317\/medoral.21024"},{"key":"13","doi-asserted-by":"crossref","unstructured":"do Vale Souza JP, Neto CL, Piacenza LT, Da Silva EV, de Melo Moreno AL, Penitente PA, Brunetto JL, Dos Santos DM, Goiato MC. Relation between insertion torque and implant stability quotient: A clinical study. Eur J Dent. 2021;15(4):618-23.","DOI":"10.1055\/s-0041-1725575"},{"key":"14","doi-asserted-by":"crossref","unstructured":"Bannwart LC, Santos DMD, Souza JPDV, Melo Neto CLM, Silva EVFD, Mazaro JVQ, Salzedas LMP, Goiato MC. Influence of torque and bone type on stability quotient of two implant platforms: A clinical trial. Braz Oral Res. 2024;38:e049.","DOI":"10.1590\/1807-3107bor-2024.vol38.0049"},{"key":"15","doi-asserted-by":"crossref","unstructured":"Levin BP. The correlation between immediate implant insertion torque and implant stability quotient. Int J Periodont Restor Dent. 2016;36:833-40.","DOI":"10.11607\/prd.2865"},{"key":"16","doi-asserted-by":"crossref","unstructured":"Revilla-Le\u00f3n M, Sadeghpour M, Ozcan M. A review of the applications of additive manufacturing technologies used to fabricate metals in implant dentistry. J Prosthodont. 2020;29(7):579-93.","DOI":"10.1111\/jopr.13212"},{"key":"17","doi-asserted-by":"crossref","unstructured":"Oliveira TT, Reis AC. Fabrication of dental implants by the additive manufacturing method: A systematic review. J Prosthet Dent. 2019 Sep;122(3):270-4. doi: 10.1016\/j.prosdent.2019.01.018. Epub 2019 Mar 27.","DOI":"10.1016\/j.prosdent.2019.01.018"},{"key":"18","doi-asserted-by":"crossref","unstructured":"de Oliveira DW, Lages FS, Lanza LA, Gomes AM, Queiroz TP, de Oliveira Costa F. Dental implants with immediate loading using insertion torque of 30 Ncm: A systematic review. Implant Dent. 2016;25(5):675-83.","DOI":"10.1097\/ID.0000000000000444"},{"key":"19","unstructured":"Warreth A, McAleese E, McDonnell P, Slami R, Guray SM. Dental implants and single implant-supported restorations. J Ir Dent Assoc. 2013;59(1):32-43."},{"key":"20","doi-asserted-by":"crossref","unstructured":"Goiato MC, Santiago JF, Pellizzer EP, Moreno A, Villa LM, Dekon SF, Carvalho PS, Santos DM. Systemic transand postoperative evaluations of patients undergoing dental implant surgery. Clinics. 2016;71(3):156-62.","DOI":"10.6061\/clinics\/2016(03)07"},{"key":"21","doi-asserted-by":"crossref","unstructured":"Mangano FG, Mangano C, Ricci M, Sammons RL, Shibli JA, Piattelli A. Esthetic evaluation of single-tooth Morse taper connection implants placed in fresh extraction sockets or healed sites. J Oral Implant. 2013;39: 172-81.","DOI":"10.1563\/AAID-JOI-D-11-00112"},{"key":"22","doi-asserted-by":"crossref","unstructured":"Trisi P, Berardi D, Paolantonio M, Spoto G, D'Addona A, Perfetti G. Primary stability, insertion torque, and bone density of conical implants with internal hexagon: Is there a relationship? J Craniofac Surg. 2013;24(3):841-4.","DOI":"10.1097\/SCS.0b013e31827c9e01"},{"key":"23","doi-asserted-by":"crossref","unstructured":"Vinhas AS, Aroso C, Salazar F, L\u00f3pez-Jarana P, R\u00ef\u00bf\u00bdos-Santos JV, Herrero-Climent M. Review of the mechanical behavior of different implant-abutment connections. Int J Environ Res Public Health. 2020;17(22):8685. doi: 10.3390\/ijerph17228685.","DOI":"10.3390\/ijerph17228685"},{"key":"24","doi-asserted-by":"crossref","unstructured":"V\u00e9lez J, Pel\u00e1ez J, L\u00f3pez-Su\u00e1rez C, Agust\u00edn-Panadero R, Tobar C, Su\u00e1rez MJ. Influence of implant connection, abutment design and screw insertion torque on implant-abutment misfit. J Clin Med. 2020;9(8):2365. doi: 10.3390\/jcm9082365.","DOI":"10.3390\/jcm9082365"},{"key":"25","unstructured":"Lekholm U, Zarb G. Patient selection and preparation. In: Branemark PI, Zarb G, Alberktsson T, editors. Tissue-integrated prostheses: Osseointegration in clinical dentistry. Chicago: Quintessence; 1985. p. 199-209."},{"key":"26","doi-asserted-by":"crossref","unstructured":"Dursum E, Tulunoglu I, Canpinar P, Uysal S, Akalin FA, Tozum T. Are marginal bone levels and implant\/mobility affected by single-stage platform switched dental implants? A comparative clinical study. Clin Oral Implant Res. 2012;23:1161-7.","DOI":"10.1111\/j.1600-0501.2011.02277.x"}],"container-title":["Journal of Long-Term Effects of Medical Implants"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.dl.begellhouse.com\/download\/article\/1ffa73d7415bbf63\/JLT-60463.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T07:29:23Z","timestamp":1763018963000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.dl.begellhouse.com\/journals\/1bef42082d7a0fdf,103b9c021ad8c265,1ffa73d7415bbf63.html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025]]},"references-count":25,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1615\/jlongtermeffmedimplants.2025060463","relation":{},"ISSN":["1050-6934"],"issn-type":[{"type":"print","value":"1050-6934"}],"subject":[],"published":{"date-parts":[[2025]]}}}