{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T21:00:54Z","timestamp":1784840454342,"version":"3.55.0"},"reference-count":25,"publisher":"Begell House","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Long Term Eff Med Implants"],"published-print":{"date-parts":[[2026]]},"abstract":"<p>Pretibial cyst formation is an uncommon but clinically significant complication following anterior cruciate ligament (ACL) reconstruction using bioabsorbable poly-L-lactic acid (PLLA) interference screws. This study reviews six cases of pretibial cyst formation after ACL reconstruction to evaluate its etiology, clinical presentation, and treatment outcomes. A retrospective analysis was conducted on six patients from a cohort of 446 ACL reconstructions performed with PLLA screws. Patients presented 2-4 years postoperatively with pretibial swelling and tenderness without systemic infection or allergic manifestations. Radiographs and magnetic resonance imaging demonstrated multiloculated cystic lesions and tibial tunnel widening adjacent to degrading screws. All patients underwent cyst debridement and screw removal, and histopathological specimens were analyzed. Histological examination revealed granulomatous inflammation characterized by macrophages, foreign body giant cells, and focal necrosis, supporting a foreign body reaction to PLLA degradation. Clinical evaluation showed preserved knee stability, with stable Lysholm, IKDC, and Lachman scores, although Tegner activity scores demonstrated mild postoperative decline. No communication between the cyst and joint space was identified, supporting the hypothesis that cyst formation results from localized inflammatory reactions rather than synovial fluid leakage. These findings suggest that PLLA screw degradation may induce foreign body reactions leading to pretibial cyst formation after ACL reconstruction. Surgical excision of the cyst and removal of the bioabsorbable screw resulted in symptom resolution without recurrence. Further investigation into alternative bioabsorbable materials with improved biocompatibility and degradation profiles is warranted to reduce inflammatory complications following ACL reconstruction.<\/p>","DOI":"10.1615\/jlongtermeffmedimplants.2025062524","type":"journal-article","created":{"date-parts":[[2025,12,17]],"date-time":"2025-12-17T23:33:56Z","timestamp":1766014436000},"page":"59-66","source":"Crossref","is-referenced-by-count":0,"title":["PLLA Screw-Related Foreign Body Reaction and Role in Pretibial Cyst Formation after ACL Reconstruction"],"prefix":"10.1615","volume":"36","author":[{"given":"Orestis K.","family":"Konstantas","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anastasios","family":"Roustemis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dimitrios","family":"Koulalis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dimitrios","family":"Mastrokalos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"613","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"Shellock FG, Mink JH, Curtin S, Friedman MJ. MR imaging and metallic implants for anterior cruciate ligament reconstruction: Assessment of ferromagnetism and artifact. J Magn Reson Imaging. 1992;2(2):225-\u0080\u00938.","DOI":"10.1002\/jmri.1880020217"},{"key":"2","doi-asserted-by":"crossref","unstructured":"Konan S, Haddad FS. A clinical review of bioabsorbable interference screws and their adverse effects in anterior cruciate ligament reconstruction surgery. Knee. 2009;16(1):6-\u0080\u009313.","DOI":"10.1016\/j.knee.2008.06.001"},{"key":"3","doi-asserted-by":"crossref","unstructured":"Shen C, Jiang SD, Jiang LS, Dai LY. Bioabsorbable versus metallic interference screw fixation in anterior cruciate ligament reconstruction: A meta-analysis of randomized controlled trials. Arthroscopy. 2010;26(5):705-\u0080\u009313.","DOI":"10.1016\/j.arthro.2009.12.011"},{"key":"4","doi-asserted-by":"crossref","unstructured":"Konan S, Haddad FS. The unpredictable material properties of bioabsorbable PLC interference screws and their adverse effects in ACL reconstruction surgery. Knee Surg Sports Traumatol Arthrosc. 2009;17(3):293-\u0080\u00937.","DOI":"10.1007\/s00167-008-0684-x"},{"key":"5","doi-asserted-by":"crossref","unstructured":"Deie M, Sumen Y, Ochi M, Murakami Y, Fujimoto E, Ikuta Y. Pretibial cyst formation after anterior cruciate ligament reconstruction using auto hamstring grafts: Two case reports in a prospective study of 89 cases. Magn Reson Imaging. 2000;18(8):973-\u0080\u00937.","DOI":"10.1016\/S0730-725X(00)00207-1"},{"key":"6","doi-asserted-by":"crossref","unstructured":"Feldmann DD, Fanelli GC. Development of a synovial cyst following anterior cruciate ligament reconstruction. Arthroscopy. 2001;17(2):200-\u0080\u00932.","DOI":"10.1053\/jars.2001.8019"},{"key":"7","doi-asserted-by":"crossref","unstructured":"Ilahi OA, Younas SA, Sahni IK. Pretibial cyst formation after arthroscopic anterior cruciate ligament reconstruction. Arthroscopy. 2003;19(2):1-\u0080\u00933.","DOI":"10.1053\/jars.2003.50045"},{"key":"8","doi-asserted-by":"crossref","unstructured":"Malhan K, Kumar A, Rees D. Tibial cyst formation after anterior cruciate ligament reconstruction using a new bioabsorbable screw. Knee. 2002;9(1):73-\u0080\u00935.","DOI":"10.1016\/S0968-0160(01)00109-0"},{"key":"9","doi-asserted-by":"crossref","unstructured":"Martinek V, Friederich NF. Tibial and pretibial cyst formation after anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation. Arthroscopy. 1999;15(3):317-\u0080\u009320.","DOI":"10.1016\/S0749-8063(99)70042-3"},{"key":"10","doi-asserted-by":"crossref","unstructured":"Sanders TG, Tall MA, Mulloy JP, Leis HT. Fluid collections in the osseous tunnel during the first year after anterior cruciate ligament repair using an autologous hamstring graft: Natural history and clinical correlation. J Comput Assist Tomogr. 2002;26(4):617-\u0080\u009321.","DOI":"10.1097\/00004728-200207000-00025"},{"key":"11","doi-asserted-by":"crossref","unstructured":"Simonian PT, Wickiewicz TL, O'\u0080\u0099Brien SJ, Dines JS, Schatz JA, Warren RF. Pretibial cyst formation after anterior cruciate ligament surgery with soft tissue autografts. Arthroscopy. 1998;14(2):215-\u0080\u009320.","DOI":"10.1016\/S0749-8063(98)70044-1"},{"key":"12","doi-asserted-by":"crossref","unstructured":"Tsuda E, Ishibashi Y, Tazawa K, Sato H, Kusumi T, Toh S. Pretibial cyst formation after anterior cruciate ligament reconstruction with a hamstring tendon autograft. Arthroscopy. 2006;22(6):691.e1-\u0080\u00936.","DOI":"10.1016\/j.arthro.2005.04.115"},{"key":"13","doi-asserted-by":"crossref","unstructured":"Victoroff BN, Paulos L, Beck C, Goodfellow DB. Subcutaneous pretibial cyst formation associated with anterior cruciate ligament allografts: A report of four cases and literature review. Arthroscopy. 1995;11(4):486-\u0080\u009394.","DOI":"10.1016\/0749-8063(95)90206-6"},{"key":"14","doi-asserted-by":"crossref","unstructured":"Bostman OM. Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures. Clin Orthop Relat Res. 1992;278(278):193-\u0080\u00939.","DOI":"10.1097\/00003086-199205000-00031"},{"key":"15","doi-asserted-by":"crossref","unstructured":"Benedetto KP, Fellinger M, Lim TE, Passler JM, Schoen JL, Willems WJ. A new bioabsorbable interference screw: Preliminary results of a prospective, multicenter, randomized clinical trial. Arthroscopy. 2000;16(1):41-\u0080\u00938.","DOI":"10.1016\/S0749-8063(00)90126-9"},{"key":"16","doi-asserted-by":"crossref","unstructured":"Brager MA, Traina SM, Parker AW, Camozzi AB. Pretibial cyst following anterior cruciate ligament reconstruction using hamstring autografts. Orthopedics. 2002;25(1):79-\u0080\u009382.","DOI":"10.3928\/0147-7447-20020101-22"},{"key":"17","doi-asserted-by":"crossref","unstructured":"Weiler A, Hoffmann RFG, St\u00e4helin AC, Helling HJ, S\u00fcdkamp NP. Biodegradable implants in sports medicine: The biological base. Arthroscopy. 2000;16(3):305-\u0080\u009321.","DOI":"10.1016\/S0749-8063(00)90055-0"},{"key":"18","unstructured":"Williams RJ, Johnson DP. Controversies in knee surgery. New York: Springer; 2004. p. 553."},{"key":"19","doi-asserted-by":"crossref","unstructured":"Lind M, Feller J, Webster KE. Tibial bone tunnel widening is reduced by polylactate\/hydroxyapatite interference screws compared to metal screws after ACL reconstruction with hamstring grafts. Knee. 2009;16(6): 447-\u0080\u009351.","DOI":"10.1016\/j.knee.2009.04.003"},{"key":"20","doi-asserted-by":"crossref","unstructured":"Busfield BT, Anderson LJ. Sterile pretibial abscess after anterior cruciate reconstruction from bioabsorbable interference screws: A report of 2 cases. Arthroscopy. 2007;23(8):911.e1-\u0080\u00934.","DOI":"10.1016\/j.arthro.2006.07.025"},{"key":"21","doi-asserted-by":"crossref","unstructured":"Pihlajam\u00e4ki H, B\u00f6stman O, Tynninen O, Laitinen O. Long-term tissue response to bioabsorbable poly-L-lactide and metallic screws: An experimental study. Bone. 2006;39(4):932-\u0080\u00937.","DOI":"10.1016\/j.bone.2006.04.009"},{"key":"22","doi-asserted-by":"crossref","unstructured":"Gonzalez-Lomas G, Cassilly RT, Remotti F, Levine WN. Is the etiology of pretibial cyst formation after absorbable interference screw use related to a foreign body reaction? Clin Orthop Relat Res. 2011;469(4):1082-\u0080\u00938.","DOI":"10.1007\/s11999-010-1580-5"},{"key":"23","doi-asserted-by":"crossref","unstructured":"Sprowson AP, Aldridge SE, Noakes J, Read JW, Wood DG. Bio-interference screw cyst formation in anterior cruciate ligament reconstruction-\u0080\u009410-year follow up. Knee. 2012;19(5):644-\u0080\u00937.","DOI":"10.1016\/j.knee.2012.01.004"},{"key":"24","doi-asserted-by":"crossref","unstructured":"Migliaresi C, Fambri1 L, Cohn D. A study on the in vitro degradation of poly(lactic acid). J Biomater Sci Polym Ed. 1994;5(6):591-\u0080\u0093606.","DOI":"10.1163\/156856294X00220"},{"key":"25","doi-asserted-by":"crossref","unstructured":"Ambrose CG, Clanton TO. Bioabsorbable implants: Review of clinical experience in orthopedic surgery. Ann Biomed Eng. 2004;32(1):171-\u0080\u00937.","DOI":"10.1023\/B:ABME.0000007802.59936.fc"}],"container-title":["Journal of Long-Term Effects of Medical Implants"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.dl.begellhouse.com\/download\/article\/24e50fd858be14ad\/JLT-62524.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T20:05:05Z","timestamp":1784837105000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.dl.begellhouse.com\/journals\/1bef42082d7a0fdf,23fd70422a5de2ce,24e50fd858be14ad.html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026]]},"references-count":25,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1615\/jlongtermeffmedimplants.2025062524","relation":{},"ISSN":["1050-6934"],"issn-type":[{"value":"1050-6934","type":"print"}],"subject":[],"published":{"date-parts":[[2026]]}}}