{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,6]],"date-time":"2025-11-06T16:00:18Z","timestamp":1762444818185},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2018,7,25]],"date-time":"2018-07-25T00:00:00Z","timestamp":1532476800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Mater Struct"],"published-print":{"date-parts":[[2018,8]]},"DOI":"10.1617\/s11527-018-1234-8","type":"journal-article","created":{"date-parts":[[2018,7,25]],"date-time":"2018-07-25T04:58:36Z","timestamp":1532494716000},"update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Experimentations on the retrofitting of damaged Single Step Joints with Self-Tapping Screws"],"prefix":"10.1617","volume":"51","author":[{"given":"Maxime","family":"Verbist","sequence":"first","affiliation":[]},{"given":"Jorge M.","family":"Branco","sequence":"additional","affiliation":[]},{"given":"Elisa","family":"Poletti","sequence":"additional","affiliation":[]},{"given":"Thierry","family":"Descamps","sequence":"additional","affiliation":[]},{"given":"Paulo B.","family":"Lourenco","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2018,7,25]]},"reference":[{"key":"1234_CR1","unstructured":"Valentin J-L (2009) La charpente, mode d\u2019emploi \u2013 Chantiers pratiques. Edition Eyrolles, deuxi\u00e8me tirage"},{"key":"1234_CR2","doi-asserted-by":"publisher","DOI":"10.1680\/trohts.32132","volume-title":"The repair of historic timber structures","author":"D Yeomans","year":"2003","unstructured":"Yeomans D (2003) The repair of historic timber structures. Thomas Telford Ltd, London"},{"key":"1234_CR3","unstructured":"Shupe T, Lebow S, Ring D (2008) Causes and control of wood decay, degradation and stain. LSU AgCenter\u2014Research & Extension. Louisiana State University Agriculture Center, Baton Rouge, LA. Publication 2703. \n                    https:\/\/www.fpl.fs.fed.us\/documnts\/pdf2008\/fpl_2008_shupe001.pdf\n                    \n                  . Accessed 2 Aug 2017"},{"key":"1234_CR4","first-page":"857","volume-title":"Historical constructions","author":"CDM Teles","year":"2001","unstructured":"Teles CDM, Do Valle A (2001) Wood structures: acting before deterioration. In: Louren\u00e7o PB, Roca P (eds) Historical constructions. University of Minho, Guimar\u00e3es, pp 857\u2013866"},{"key":"1234_CR5","doi-asserted-by":"publisher","DOI":"10.1617\/s11527-017-1028-4","author":"M Verbist","year":"2017","unstructured":"Verbist M, Branco JM, Poletti E, Descamps T, Louren\u00e7o P (2017) Single Step Joint: overview of European standardized approaches and experimentations. Mater Struct. \n                    https:\/\/doi.org\/10.1617\/s11527-017-1028-4","journal-title":"Mater Struct"},{"key":"1234_CR6","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1016\/j.conbuildmat.2015.05.089","volume":"97","author":"JM Branco","year":"2015","unstructured":"Branco JM, Descamps T (2015) Analysis and strengthening of carpentry joints. Constr Build Mater 97:34\u201347 (Special Issue: Reinforcement of Timber Structures)","journal-title":"Constr Build Mater"},{"key":"1234_CR7","doi-asserted-by":"publisher","first-page":"1019","DOI":"10.1016\/j.culher.2016.05.011","volume":"22","author":"G Tampone","year":"2016","unstructured":"Tampone G, Ruggieri N (2016) State-of-the-art technology on conservation of ancient roofs with timber structure. J Cult Herit 22:1019\u20131027","journal-title":"J Cult Herit"},{"key":"1234_CR8","first-page":"52","volume":"47","author":"T Descamps","year":"2016","unstructured":"Descamps T, Avez C, Carpentier O, Antczak E, Jeong GY (2016) Historic timber roofs modelling: prosthesis and resin repairs. J Herit Conserv 47:52\u201360","journal-title":"J Herit Conserv"},{"issue":"12","key":"1234_CR9","doi-asserted-by":"publisher","first-page":"1395","DOI":"10.1061\/(ASCE)0733-9445(2000)126:12(1395)","volume":"126","author":"MA Parisi","year":"2000","unstructured":"Parisi MA, Piazza M (2000) Mechanics of plain and retrofitted traditional timber connections. J Struct Eng ASCE 126(12):1395\u20131403","journal-title":"J Struct Eng ASCE"},{"key":"1234_CR10","first-page":"119","volume-title":"Criteria, innovative solutions and case studies. Semin\u00e1rio Intervir em Constru\u00e7\u00f5es Existentes de Madeira","author":"G Croatto","year":"2014","unstructured":"Croatto G, Turrini U (2014) Restoration of historical timber structures. In: Louren\u00e7o PB, Branco JM, Sousa HS (eds) Criteria, innovative solutions and case studies. Semin\u00e1rio Intervir em Constru\u00e7\u00f5es Existentes de Madeira, Universidade do Minho, Guimar\u00e3es, pp 119\u2013136"},{"key":"1234_CR11","unstructured":"G\u00f6rlacher R, Kromer M (1991) Tragf\u00e4higkeit von Versatzanschl\u00fcssen in historischen Holzkonstruktionen. Bruderverlag, Karlsruhe. Edited by Bauen Mit Holz"},{"key":"1234_CR12","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/j.conbuildmat.2015.03.086","volume":"87","author":"P Munaf\u00f2","year":"2015","unstructured":"Munaf\u00f2 P, Stazi F, Tassi C, Davi F (2015) Experimentation on historic timber trusses to identify repair techniques compliant with the original structural-constructive conception. Constr Build Mater 87:54\u201366","journal-title":"Constr Build Mater"},{"key":"1234_CR13","first-page":"359","volume-title":"Lecture Notes in Civil Engineering","author":"Karel \u0160obra","year":"2016","unstructured":"Sobra K, de Rijk R, Aktas YD, Avez C, Burawska I, Branco JM (2016) Experimental and analytical assessment of the capacity of traditional single notch joints and impact of retrofitting by self-tapping screws. In: Historical earthquake-resistant timber framing in the mediterranean area, pp 359\u2013369"},{"key":"1234_CR14","unstructured":"Blass HJ, Bejtka I (2002) Joints with inclined screws. International Council for research and Innovation in Building and Construction. Working Commission W18, Timber Structures, CIB-W\u00a018\/35-7-5\u2014Kyoto, Japan, September 2002"},{"key":"1234_CR15","volume-title":"Reinforcement of connections with dowel-type fasteners. Reinforcement of Timber Structures, A state-of-art report","author":"L Bl\u00e9ron","year":"2015","unstructured":"Bl\u00e9ron L, Lathuilli\u00e8re D, Descamps T, Bocquet J-F (2015) In: Harte A, Dietsch P (eds) Reinforcement of connections with dowel-type fasteners. Reinforcement of Timber Structures, A state-of-art report. Shaker Verlag, Aachen"},{"key":"1234_CR16","volume-title":"Reinforcement with self-tapping screws and threaded rods. Reinforcement of timber structures, A state-of-art report","author":"P Dietsch","year":"2015","unstructured":"Dietsch P, Reinhard B (2015) In: Harte A, Dietsch P (eds) Reinforcement with self-tapping screws and threaded rods. Reinforcement of timber structures, A state-of-art report. Shaker Verlag, Aachen"},{"key":"1234_CR17","doi-asserted-by":"publisher","first-page":"1560","DOI":"10.1016\/j.conbuildmat.2010.03.007","volume":"24","author":"R Tomasi","year":"2010","unstructured":"Tomasi R, Crosatti A, Piazza M (2010) Theoretical and experimental analysis of timber-to-timber joints connected with inclined screws. Constr Build Mater 24:1560\u20131571","journal-title":"Constr Build Mater"},{"key":"1234_CR18","unstructured":"ETA-11\/0030, European Technical Approval (2012). Self-tapping screws for use in timber structures. EOTA (European Organization for Technical Approval). Rotho Blaas Self-tapping Screws"},{"key":"1234_CR19","unstructured":"Eurocode 5, NBN EN 1995-1-1 (2004) Design of timber structures. Part 1\u20101: General. Common rules and rules for buildings. CEN, European Standardization Institute, Brussels, Belgium"},{"key":"1234_CR20","unstructured":"Uibel T, Blass HJ (2010) A new method to determine suitable spacings and distances for self-tapping screws. In: International council for research and innovation in building and construction\u2014working commission W18, Timber Structures. New Zealand"}],"container-title":["Materials and Structures"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1617\/s11527-018-1234-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1617\/s11527-018-1234-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1617\/s11527-018-1234-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,7,24]],"date-time":"2019-07-24T19:03:55Z","timestamp":1563995035000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1617\/s11527-018-1234-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7,25]]},"references-count":20,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2018,8]]}},"alternative-id":["1234"],"URL":"https:\/\/doi.org\/10.1617\/s11527-018-1234-8","relation":{},"ISSN":["1359-5997","1871-6873"],"issn-type":[{"value":"1359-5997","type":"print"},{"value":"1871-6873","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,7,25]]},"assertion":[{"value":"22 January 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 July 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 July 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}],"article-number":"106"}}