{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,2]],"date-time":"2025-06-02T23:28:51Z","timestamp":1748906931668},"reference-count":18,"publisher":"Tohoku University Medical Press","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Tohoku J. Exp. Med."],"published-print":{"date-parts":[[2021]]},"DOI":"10.1620\/tjem.255.221","type":"journal-article","created":{"date-parts":[[2021,11,10]],"date-time":"2021-11-10T22:10:14Z","timestamp":1636582214000},"page":"221-227","source":"Crossref","is-referenced-by-count":3,"title":["The Optimal \u201cTime in Range\u201d and \u201cTime below Range\u201d are Difficult to Coordinate in Patients with Type 1 Diabetes"],"prefix":"10.1620","volume":"255","author":[{"given":"Sho","family":"Sekiguchi","sequence":"first","affiliation":[{"name":"Department of Medicine and Molecular Science, Gunma University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eijiro","family":"Yamada","sequence":"additional","affiliation":[{"name":"Department of Medicine and Molecular Science, Gunma University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasuyo","family":"Nakajima","sequence":"additional","affiliation":[{"name":"Department of Medicine and Molecular Science, Gunma University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shunichi","family":"Matsumoto","sequence":"additional","affiliation":[{"name":"Department of Medicine and Molecular Science, Gunma University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoshi","family":"Yoshino","sequence":"additional","affiliation":[{"name":"Department of Medicine and Molecular Science, Gunma University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuhiko","family":"Horiguchi","sequence":"additional","affiliation":[{"name":"Department of Medicine and Molecular Science, Gunma University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emi","family":"Ishida","sequence":"additional","affiliation":[{"name":"Department of Medicine and Molecular Science, Gunma University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryota","family":"Uehara","sequence":"additional","affiliation":[{"name":"Department of Medicine and Molecular Science, Gunma University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shuichi","family":"Okada","sequence":"additional","affiliation":[{"name":"Department of Medicine and Molecular Science, Gunma University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masanobu","family":"Yamada","sequence":"additional","affiliation":[{"name":"Department of Medicine and Molecular Science, Gunma University Graduate School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"622","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"Bailey, T., Bode, B.W., Christiansen, M.P., Klaff, L.J. &amp; Alva, S.(2015)  The performance and usability of a factory-calibrated flash glucose monitoring system.  <i>Diabetes Technol. Ther<\/i>., 17, 787-794.","DOI":"10.1089\/dia.2014.0378"},{"key":"2","doi-asserted-by":"crossref","unstructured":"Battelino, T., Danne, T., Bergenstal, R.M., Amiel, S.A., Beck, R., Biester, T., Bosi, E., Buckingham, B.A., Cefalu, W.T., Close, K.L., Cobelli, C., Dassau, E., DeVries, J.H., Donaghue, K.C., Dovc, K.,  et al.(2019)  Clinical targets for continuous glucose monitoring data interpretation: recommendations from the international consensus on time in range.  <i>Diabetes Care<\/i>, 42, 1593-1603.","DOI":"10.2337\/dci19-0028"},{"key":"3","doi-asserted-by":"crossref","unstructured":"Bode, B.W., Gross, T.M., Thornton, K.R. &amp; Mastrototaro, J.J.(1999)  Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: a pilot study.  <i>Diabetes Res. Clin. Pract<\/i>., 46, 183-190.","DOI":"10.1016\/S0168-8227(99)00113-8"},{"key":"4","doi-asserted-by":"crossref","unstructured":"Danne, T., Nimri, R., Battelino, T., Bergenstal, R.M., Close, K.L., DeVries, J.H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S.A., Beck, R., Bosi, E., Buckingham, B., Cobelli, C., Dassau, E., et al.(2017)  International consensus on use of continuous glucose monitoring.  <i>Diabetes Care<\/i>, 40, 1631-1640.","DOI":"10.2337\/dc17-1600"},{"key":"5","doi-asserted-by":"crossref","unstructured":"Fabris, C., Heinemann, L., Beck, R., Cobelli, C. &amp; Kovatchev, B.(2020)  Estimation of hemoglobin A1c from continuous glucose monitoring data in individuals with type 1 diabetes: is time in range all we need?  <i>Diabetes Technol. Ther.<\/i>, 22, 501-508.","DOI":"10.1089\/dia.2020.0236"},{"key":"6","doi-asserted-by":"crossref","unstructured":"Irace, C., Cutruzzola, A., Nuzzi, A., Assaloni, R., Brunato, B., Pitocco, D., Tartaglione, L., Di Molfetta, S., Cignarelli, A., Laviola, L., Citro, G., Lovati, E., Gnasso, A., Tweden, K.S. &amp; Kaufman, F.R.(2020)  Clinical use of a 180-day implantable glucose sensor improves glycated haemoglobin and time in range in patients with type 1 diabetes.  <i>Diabetes Obes. Metab<\/i>., 22, 1056-1061.","DOI":"10.1111\/dom.13993"},{"key":"7","doi-asserted-by":"crossref","unstructured":"Lu, J., Ma, X., Zhang, L., Mo, Y., Lu, W., Zhu, W., Bao, Y., Jia, W. &amp; Zhou, J.(2020)  Glycemic variability modifies the relationship between time in range and hemoglobin A1c estimated from continuous glucose monitoring: a preliminary study.  <i>Diabetes Res. Clin. Pract<\/i>., 161, 108032.","DOI":"10.1016\/j.diabres.2020.108032"},{"key":"8","doi-asserted-by":"crossref","unstructured":"Moser, O., Eckstein, M.L., McCarthy, O., Deere, R., Pitt, J., Williams, D.M., Hayes, J., Sourij, H., Bain, S.C. &amp; Bracken, R.M.(2019)  Performance of the Freestyle Libre flash glucose monitoring (flash GM)  system in individuals with type 1 diabetes: a secondary outcome analysis of a randomized crossover trial.  <i>Diabetes Obes. Metab<\/i>., 21, 2505-2512.","DOI":"10.1111\/dom.13835"},{"key":"9","doi-asserted-by":"crossref","unstructured":"Nathan, D.M., Kuenen, J., Borg, R., Zheng, H.,  Schoenfeld, D. &amp; Heine, R.J.; A1c-Derived Average Glucose Study Group (2008)  Translating the A1C assay into estimated average glucose values.  <i>Diabetes Care<\/i>, 31, 1473-1478.","DOI":"10.2337\/dc08-0545"},{"key":"10","doi-asserted-by":"crossref","unstructured":"Ohigashi, M., Osugi, K., Kusunoki, Y., Washio, K., Matsutani, S., Tsunoda, T., Matsuo, T., Konishi, K., Katsuno, T., Namba, M. &amp; Koyama, H.(2021)  Association of time in range with hemoglobin A1c, glycated albumin and 1,5-anhydro-d-glucitol.  <i>J. Diabetes Investig<\/i>., 12, 940-949.","DOI":"10.1111\/jdi.13437"},{"key":"11","doi-asserted-by":"crossref","unstructured":"Rama Chandran, S., A. Vigersky, R., Thomas, A., Lim, L.L., Ratnasingam, J., Tan, A. &amp; S.L. Gardner, D.(2020)  Role of composite glycemic indices: a comparison of the comprehensive glucose pentagon across diabetes types and HbA1c levels.  <i>Diabetes Technol. Ther<\/i>., 22, 103-111.","DOI":"10.1089\/dia.2019.0277"},{"key":"12","doi-asserted-by":"crossref","unstructured":"Rodbard, D. (2016)  Continuous glucose monitoring: a review of successes, challenges, and opportunities.  <i>Diabetes Technol. Ther.<\/i>, 18 Suppl 2, S3-S13.","DOI":"10.1089\/dia.2015.0417"},{"key":"13","doi-asserted-by":"crossref","unstructured":"Rodbard, D.(2020)  Glucose time in range, time above range, and time below range depend on mean or median glucose or HbA1c, glucose coefficient of variation, and shape of the glucose distribution.  <i>Diabetes Technol. Ther<\/i>., 22, 492-500.","DOI":"10.1089\/dia.2019.0440"},{"key":"14","doi-asserted-by":"crossref","unstructured":"Tsoukas, M., Rutkowski, J., El-Fathi, A., Yale, J.F., Bernier-Twardy, S., Bossy, A., Pytka, E., Legault, L. &amp; Haidar, A.(2020)  Accuracy of FreeStyle Libre in adults with type 1 diabetes: the effect of sensor age.  <i>Diabetes Technol. Ther<\/i>., 22, 203-207.","DOI":"10.1089\/dia.2019.0262"},{"key":"15","doi-asserted-by":"crossref","unstructured":"Urakami, T., Yoshida, K., Kuwabara, R., Mine, Y., Aoki, M., Suzuki, J. &amp; Morioka, I.(2020)  Individualization of recommendations from the international consensus on continuous glucose monitoring-derived metrics in Japanese children and adolescents with type 1 diabetes.  <i>Endocr. J<\/i>., 67, 1055-1062.","DOI":"10.1507\/endocrj.EJ20-0193"},{"key":"16","doi-asserted-by":"crossref","unstructured":"Vigersky, R. &amp; Shrivastav, M.(2017)  Role of continuous glucose monitoring for type 2 in diabetes management and research.  <i>J. Diabetes Complications<\/i>, 31, 280-287.","DOI":"10.1016\/j.jdiacomp.2016.10.007"},{"key":"17","doi-asserted-by":"crossref","unstructured":"Vigersky, R.A. &amp; McMahon, C.(2019)  The relationship of hemoglobin A1C to time-in-range in patients with diabetes.  <i>Diabetes Technol. Ther<\/i>., 21, 81-85.","DOI":"10.1089\/dia.2018.0310"},{"key":"18","doi-asserted-by":"crossref","unstructured":"Xing, D., Kollman, C., Beck, R.W., Tamborlane, W.V., Laffel, L., Buckingham, B.A., Wilson, D.M., Weinzimer, S.,  Fiallo-Scharer, R. &amp; Ruedy, K.J.; Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2011)  Optimal sampling intervals to assess long-term glycemic control using continuous glucose monitoring.  <i>Diabetes Technol. Ther<\/i>., 13, 351-358.","DOI":"10.1089\/dia.2010.0156"}],"container-title":["The Tohoku Journal of Experimental Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/tjem\/255\/3\/255_221\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,13]],"date-time":"2021-11-13T04:27:37Z","timestamp":1636777657000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/tjem\/255\/3\/255_221\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021]]},"references-count":18,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1620\/tjem.255.221","relation":{},"ISSN":["0040-8727","1349-3329"],"issn-type":[{"value":"0040-8727","type":"print"},{"value":"1349-3329","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021]]}}}