{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T20:01:09Z","timestamp":1786132869083,"version":"build-2736575974"},"reference-count":100,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","funder":[{"DOI":"10.13039\/100000062","name":"National Institute of Diabetes and Digestive and Kidney Diseases","doi-asserted-by":"crossref","award":["K23DK122131"],"award-info":[{"award-number":["K23DK122131"]}],"id":[{"id":"10.13039\/100000062","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["JASN"],"published-print":{"date-parts":[[2026,3]]},"abstract":"<jats:p>Mechanical circulatory support is used to augment circulatory flow in cardiogenic shock and end-stage heart failure. Support can last from hours for temporary mechanical circulatory support to years for durable mechanical circulatory support. The physiologic relationship of heart and kidney function and the epidemic of cardio-kidney-metabolic disease lead to frequent use of simultaneous mechanical circulatory support and extracorporeal KRT (dialysis). The need for dialysis can range from short periods of AKI in cardiogenic shock to long-term dialysis for individuals who receive left ventricular assist devices (LVADs) for destination therapy in advanced heart failure and progress to CKD G5 with replacement therapy. Changes in technology, clinical evidence, and organ transplantation have led to major changes in mechanical circulatory support use. With temporary mechanical circulatory support, devices and clinical situations vary widely, with intra-aortic balloon pumps, microaxial flow pumps, and venoarterial extracorporeal membrane oxygenation providing different levels of circulatory support. Considerations for dialysis, whether for AKI or CKD G5, are discussed. In durable mechanical circulatory support, LVADs are now used primarily for permanent therapy, and most LVAD recipients survive for more than 5 years, time in which kidney dysfunction can develop or progress. Outpatient dialysis with LVADs is performed for both AKI and for CKD G5, with in-center intermittent hemodialysis, peritoneal dialysis, or home hemodialysis. This article discusses considerations specific to dialysis in temporary and durable circulatory support, including the challenging aspects of volume management and complication risks. Concurrent mechanical circulatory support and dialysis present diverse clinical challenges in patients with complex medical needs. Meeting this challenge requires close cooperation and shared decision making incorporating cardiologists, nephrologists, other medical professionals, patients, and their caregivers.<\/jats:p>","DOI":"10.1681\/asn.0000001013","type":"journal-article","created":{"date-parts":[[2025,12,24]],"date-time":"2025-12-24T13:00:34Z","timestamp":1766581234000},"page":"596-606","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Management of Dialysis for Patients Receiving Mechanical Circulatory Support"],"prefix":"10.1681","volume":"37","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0219-2870","authenticated-orcid":false,"given":"Carl P.","family":"Walther","sequence":"first","affiliation":[{"name":"Section of Nephrology, Department of Medicine, Selzman Institute for Kidney Health, Baylor College of Medicine, Houston, Texas"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ajith P.","family":"Nair","sequence":"additional","affiliation":[{"name":"Section of Cardiology, Department of Medicine, Baylor College of Medicine, Houston, Texas"},{"name":"Advanced Heart Failure Center of Excellence, Baylor College of Medicine, Houston, Texas"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,12,24]]},"reference":[{"issue":"5","key":"B1-20260428","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1016\/j.pcad.2020.09.003","article-title":"Mechanical circulatory support devices in advanced heart failure: 2020 and beyond","volume":"63","author":"Vieira","year":"2020","journal-title":"Prog Cardiovasc Dis."},{"issue":"8","key":"B2-20260428","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1159\/000546854","article-title":"Concurrent use of kidney replacement therapy and temporary left ventricular assist device in cardiogenic shock: a systematic review and meta-analysis","volume":"54","author":"Lim","year":"2025","journal-title":"Blood Purif."},{"issue":"8","key":"B3-20260428","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1016\/j.healun.2019.06.001","article-title":"Acute kidney injury following left ventricular assist device implantation: contemporary insights and future perspectives","volume":"38","author":"Yalcin","year":"2019","journal-title":"J Heart Lung Transplant."},{"issue":"6","key":"B4-20260428","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1016\/j.healun.2022.03.018","article-title":"Temporary mechanical circulatory support: devices, outcomes, and future directions","volume":"41","author":"Baran","year":"2022","journal-title":"J Heart Lung Transplant."},{"issue":"16","key":"B5-20260428","doi-asserted-by":"crossref","first-page":"1618","DOI":"10.1016\/j.jacc.2025.02.018","article-title":"2025 concise clinical guidance: an ACC expert consensus statement on the evaluation and management of cardiogenic shock: a report of the American College of Cardiology Solution Set Oversight Committee","volume":"85","author":"Sinha","year":"2025","journal-title":"J Am Coll Cardiol."},{"issue":"4","key":"B6-20260428","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1038\/s41569-022-00796-5","article-title":"Temporary mechanical circulatory support devices: practical considerations for all stakeholders","volume":"20","author":"Salter","year":"2023","journal-title":"Nat Rev Cardiol."},{"issue":"4","key":"B7-20260428","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.healun.2022.10.028","article-title":"The International Society for Heart and Lung Transplantation\/Heart Failure Society of America guideline on acute mechanical circulatory support","volume":"42","author":"Bernhardt","year":"2023","journal-title":"J Heart Lung Transplant."},{"issue":"15","key":"B8-20260428","doi-asserted-by":"crossref","first-page":"1382","DOI":"10.1056\/NEJMoa2312572","article-title":"Microaxial flow pump or standard care in infarct-related cardiogenic shock","volume":"390","author":"M\u00f8ller","year":"2024","journal-title":"N Engl J Med."},{"issue":"13","key":"B9-20260428","first-page":"e771","article-title":"2025 ACC\/AHA\/ACEP\/NAEMSP\/SCAI guideline for the management of patients with acute coronary syndromes: a report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines","volume":"151","author":"Rao","year":"2025","journal-title":"Circulation."},{"issue":"25","key":"B10-20260428","doi-asserted-by":"crossref","first-page":"1990","DOI":"10.1161\/CIRCULATIONAHA.124.072370","article-title":"Microaxial flow pump use and renal outcomes in infarct-related cardiogenic shock: a secondary analysis of the danger shock trial","volume":"150","author":"Zweck","year":"2024","journal-title":"Circulation."},{"issue":"7","key":"B11-20260428","doi-asserted-by":"crossref","first-page":"981","DOI":"10.3390\/jcm8070981","article-title":"Incidence and impact of acute kidney injury in patients receiving extracorporeal membrane oxygenation: a meta-analysis","volume":"8","author":"Thongprayoon","year":"2019","journal-title":"J Clin Med."},{"issue":"22","key":"B12-20260428","doi-asserted-by":"crossref","first-page":"2095","DOI":"10.1161\/CIRCULATIONAHA.120.048792","article-title":"Left ventricular unloading is associated with lower mortality in patients with cardiogenic shock treated with venoarterial extracorporeal membrane oxygenation: results from an international, multicenter cohort study","volume":"142","author":"Schrage","year":"2020","journal-title":"Circulation."},{"issue":"9","key":"B13-20260428","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1001\/jamainternmed.2022.2735","article-title":"Clinical outcomes and cost associated with an intravascular microaxial left ventricular assist device vs intra-aortic balloon pump in patients presenting with acute myocardial infarction complicated by cardiogenic shock","volume":"182","author":"Miller","year":"2022","journal-title":"JAMA Intern Med."},{"issue":"3","key":"B14-20260428","doi-asserted-by":"crossref","first-page":"569","DOI":"10.34067\/KID.0003382021","article-title":"Nephrology considerations in the management of durable and temporary mechanical circulatory support","volume":"3","author":"Walther","year":"2022","journal-title":"Kidney360."},{"issue":"6","key":"B15-20260428","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1080\/17434440.2022.2108319","article-title":"Hemolysis during short-term mechanical circulatory support: from pathophysiology to diagnosis and treatment","volume":"19","author":"Balthazar","year":"2022","journal-title":"Expert Rev Med Devices."},{"issue":"6","key":"B16-20260428","doi-asserted-by":"crossref","first-page":"e50","DOI":"10.1161\/CIR.0000000000001076","article-title":"Escalating and de-escalating temporary mechanical circulatory support in cardiogenic shock: a scientific statement from the American Heart Association","volume":"146","author":"Geller","year":"2022","journal-title":"Circulation."},{"issue":"5","key":"B17-20260428","doi-asserted-by":"crossref","first-page":"1206","DOI":"10.3390\/jcm11051206","article-title":"Pulmonary artery pulsatility index and hemolysis during impella-incorporated mechanical circulatory support","volume":"11","author":"Nakamura","year":"2022","journal-title":"J Clin Med."},{"issue":"16","key":"B18-20260428","doi-asserted-by":"crossref","first-page":"3710","DOI":"10.3390\/jcm10163710","article-title":"Adverse events of percutaneous microaxial left ventricular assist devices-a retrospective, single-centre cohort study","volume":"10","author":"Zaiser","year":"2021","journal-title":"J Clin Med."},{"issue":"1","key":"B19-20260428","doi-asserted-by":"crossref","first-page":"e0227793","DOI":"10.1371\/journal.pone.0227793","article-title":"Factors associated with hemolysis during extracorporeal membrane oxygenation (ECMO)\u2014comparison of VA- versus VV ECMO","volume":"15","author":"Appelt","year":"2020","journal-title":"PLoS One."},{"issue":"11","key":"B20-20260428","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1038\/s41581-019-0181-0","article-title":"Mechanisms of haemolysis-induced kidney injury","volume":"15","author":"Van Avondt","year":"2019","journal-title":"Nat Rev Nephrol."},{"issue":"8","key":"B21-20260428","doi-asserted-by":"crossref","first-page":"1349","DOI":"10.1161\/ATVBAHA.123.318780","article-title":"Basic mechanisms of hemolysis-associated thrombo-inflammation and immune dysregulation","volume":"43","author":"Dimitrov","year":"2023","journal-title":"Arterioscler Thromb Vasc Biol."},{"issue":"1","key":"B22-20260428","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1016\/j.cardfail.2024.10.053","article-title":"Patient-reported outcomes in heart failure: insights from a simplified KCCQ in HeartMate 3 LVAD recipients","volume":"31","author":"Cowger","year":"2025","journal-title":"J Card Fail."},{"issue":"14","key":"B23-20260428","doi-asserted-by":"crossref","first-page":"1464","DOI":"10.1016\/j.jacc.2023.07.019","article-title":"Durable mechanical circulatory support: JACC scientific statement","volume":"82","author":"Tedford","year":"2023","journal-title":"J Am Coll Cardiol."},{"issue":"4","key":"B24-20260428","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1097\/MAT.0000000000001500","article-title":"Mechanical circulatory support as a bridge-to-transplant candidacy: when does it work?","volume":"68","author":"Zaliznyak","year":"2022","journal-title":"ASAIO J."},{"issue":"6","key":"B25-20260428","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1016\/j.jchf.2021.01.010","article-title":"Changes in use of left ventricular assist devices as bridge to transplantation with new heart allocation policy","volume":"9","author":"Mullan","year":"2021","journal-title":"JACC Heart Fail."},{"issue":"6","key":"B26-20260428","doi-asserted-by":"crossref","first-page":"1333","DOI":"10.1097\/TP.0000000000004834","article-title":"Contemporary left ventricular assist device therapy as a bridge or alternative to transplantation","volume":"108","author":"Boulet","year":"2024","journal-title":"Transplantation."},{"issue":"1","key":"B27-20260428","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.athoracsur.2024.10.003","article-title":"The Society of Thoracic Surgeons Intermacs 2024 annual report: focus on outcomes in younger patients","volume":"119","author":"Meyer","year":"2025","journal-title":"Ann Thorac Surg."},{"issue":"1","key":"B28-20260428","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/j.jacc.2023.04.045","article-title":"Adverse hemodynamic consequences of continuous left ventricular mechanical support: JACC review topic of the week","volume":"82","author":"Grinstein","year":"2023","journal-title":"J Am Coll Cardiol."},{"issue":"12","key":"B29-20260428","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1001\/jama.2022.16197","article-title":"Five-year outcomes in patients with fully magnetically levitated vs axial-flow left ventricular assist devices in the MOMENTUM 3 randomized trial","volume":"328","author":"Mehra","year":"2022","journal-title":"JAMA."},{"issue":"1","key":"B30-20260428","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.athoracsur.2023.11.004","article-title":"The Society of Thoracic Surgeons Intermacs 2023 annual report: focus on magnetically levitated devices","volume":"117","author":"Jorde","year":"2024","journal-title":"Ann Thorac Surg."},{"issue":"12","key":"B31-20260428","doi-asserted-by":"crossref","first-page":"1738","DOI":"10.1016\/j.cardfail.2022.09.007","article-title":"Hemodynamic aberrancies in left ventricular assist device\u2013associated heart failure syndromes","volume":"28","author":"Boulet","year":"2022","journal-title":"J Card Fail."},{"issue":"16","key":"B32-20260428","doi-asserted-by":"crossref","first-page":"e280","DOI":"10.1161\/CIR.0000000000001273","article-title":"Evaluation and management of kidney dysfunction in advanced heart failure: a scientific statement from the American Heart Association","volume":"150","author":"Tang","year":"2024","journal-title":"Circulation."},{"issue":"7","key":"B33-20260428","doi-asserted-by":"crossref","first-page":"2022","DOI":"10.3390\/jcm11072022","article-title":"The history of durable left ventricular assist devices and comparison of outcomes: heartware, HeartMate II, HeartMate 3, and the future of mechanical circulatory support","volume":"11","author":"Berardi","year":"2022","journal-title":"J Clin Med."},{"issue":"1","key":"B34-20260428","doi-asserted-by":"crossref","first-page":"2731","DOI":"10.1002\/j.2040-4603.2022.tb00201.x","article-title":"Physiology of continuous-flow left ventricular assist device therapy","volume":"12","author":"Rosenbaum","year":"2021","journal-title":"Compr Physiol."},{"issue":"4","key":"B35-20260428","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1111\/aor.13346","article-title":"Fluid dynamics in the HeartMate 3: influence of the artificial pulse feature and residual cardiac pulsation","volume":"43","author":"Wiegmann","year":"2019","journal-title":"Artif Organs."},{"issue":"9","key":"B36-20260428","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.1016\/j.healun.2023.04.002","article-title":"Pulsatility and flow patterns across macro- and microcirculatory arteries of continuous-flow left ventricular assist device patients","volume":"42","author":"St\u00f6hr","year":"2023","journal-title":"J Heart Lung Transplant."},{"issue":"7","key":"B37-20260428","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.healun.2022.12.004","article-title":"The 2023 International Society for Heart and Lung Transplantation guidelines for mechanical circulatory support: a 10- year update","volume":"42","author":"Saeed","year":"2023","journal-title":"J Heart Lung Transplant."},{"issue":"1","key":"B38-20260428","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1097\/MAT.0000000000001159","article-title":"Correction of high afterload improves low cardiac output in patients supported on left ventricular assist device therapy","volume":"67","author":"Rosenbaum","year":"2021","journal-title":"ASAIO J."},{"issue":"22","key":"B39-20260428","doi-asserted-by":"crossref","first-page":"2171","DOI":"10.1001\/jama.2023.23204","article-title":"Aspirin and hemocompatibility events with a left ventricular assist device in advanced heart failure: the ARIES-HM3 randomized clinical trial","volume":"330","author":"Mehra","year":"2023","journal-title":"JAMA."},{"issue":"9","key":"B40-20260428","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1016\/j.echo.2024.06.005","article-title":"Recommendations for multimodality imaging of patients with left ventricular assist devices and temporary mechanical support: updated recommendations from the American Society of Echocardiography","volume":"37","author":"Estep","year":"2024","journal-title":"J Am Soc Echocardiogr."},{"issue":"2","key":"B41-20260428","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1002\/ehf2.12638","article-title":"Validation of non-invasive ramp testing for HeartMate 3","volume":"7","author":"Najjar","year":"2020","journal-title":"ESC Heart Fail."},{"issue":"23","key":"B42-20260428","doi-asserted-by":"crossref","first-page":"2663","DOI":"10.1016\/j.jacc.2015.10.017","article-title":"Hemodynamics of mechanical circulatory support","volume":"66","author":"Burkhoff","year":"2015","journal-title":"J Am Coll Cardiol."},{"issue":"7","key":"B43-20260428","doi-asserted-by":"crossref","first-page":"E251","DOI":"10.1111\/aor.13638","article-title":"Continuous LVAD monitoring reveals high suction rates in clinically stable outpatients","volume":"44","author":"Gross","year":"2020","journal-title":"Artif Organs."},{"issue":"5","key":"B45-20260428","doi-asserted-by":"crossref","first-page":"822","DOI":"10.1002\/ejhf.3577","article-title":"Time-varying analyses of survival and outcomes in patients with HeartMate 3 left ventricular assist devices","volume":"27","author":"Weiss","year":"2025","journal-title":"Eur J Heart Fail."},{"issue":"8","key":"B46-20260428","doi-asserted-by":"crossref","first-page":"774","DOI":"10.1016\/j.healun.2020.03.002","article-title":"Left ventricular assist systems and infection-related outcomes: a comprehensive analysis of the MOMENTUM 3 trial","volume":"39","author":"Patel","year":"2020","journal-title":"J Heart Lung Transplant."},{"issue":"7","key":"B47-20260428","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1097\/MAT.0000000000001956","article-title":"Infections in patients with left ventricular assist devices: current state and future perspectives","volume":"69","author":"Inglis","year":"2023","journal-title":"ASAIO J."},{"issue":"2","key":"B48-20260428","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1053\/j.ajkd.2017.09.019","article-title":"Left ventricular assist devices, kidney disease, and dialysis","volume":"71","author":"Roehm","year":"2018","journal-title":"Am J Kidney Dis."},{"issue":"10","key":"B49-20260428","doi-asserted-by":"crossref","first-page":"3549","DOI":"10.1016\/j.ekir.2025.07.034","article-title":"Kidney function trajectories with mechanical circulatory support","volume":"10","author":"Walther","year":"2025","journal-title":"Kidney Int Rep."},{"issue":"17","key":"B50-20260428","doi-asserted-by":"crossref","first-page":"1618","DOI":"10.1056\/NEJMoa1900486","article-title":"A fully magnetically levitated left ventricular assist device - final report","volume":"380","author":"Mehra","year":"2019","journal-title":"N Engl J Med."},{"issue":"3","key":"B51-20260428","doi-asserted-by":"crossref","first-page":"383","DOI":"10.2215\/CJN.04310422","article-title":"Prolonged intermittent kidney replacement therapy","volume":"18","author":"Levine","year":"2023","journal-title":"Clin J Am Soc Nephrol."},{"issue":"6","key":"B52-20260428","doi-asserted-by":"crossref","first-page":"702","DOI":"10.2215\/CJN.0000000000000172","article-title":"Practice variation in the prescription of volume removal with acute KRT: a call for randomized controlled trials","volume":"18","author":"Teixeira","year":"2023","journal-title":"Clin J Am Soc Nephrol."},{"issue":"1","key":"B53-20260428","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1177\/0896860820970834","article-title":"ISPD guidelines for peritoneal dialysis in acute kidney injury: 2020 update (adults)","volume":"41","author":"Cullis","year":"2021","journal-title":"Perit Dial Int."},{"issue":"12","key":"B54-20260428","doi-asserted-by":"crossref","first-page":"1829","DOI":"10.2215\/CJN.09240620","article-title":"Peritoneal dialysis for acute kidney injury during the COVID-19 pandemic","volume":"15","author":"Shimonov","year":"2020","journal-title":"Clin J Am Soc Nephrol."},{"issue":"4","key":"B55-20260428","doi-asserted-by":"crossref","first-page":"512","DOI":"10.2215\/CJN.0000000000000059","article-title":"Peritoneal dialysis in critically Ill patients: time for a critical reevaluation?","volume":"18","author":"Al Sahlawi","year":"2023","journal-title":"Clin J Am Soc Nephrol."},{"issue":"2","key":"B56-20260428","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1093\/ckj\/sfac201","article-title":"Peritoneal dialysis for acute kidney injury: back on the front-line","volume":"16","author":"Cullis","year":"2023","journal-title":"Clin Kidney J."},{"issue":"1","key":"B57-20260428","doi-asserted-by":"crossref","first-page":"29","DOI":"10.3747\/pdi.2010.00300","article-title":"High rates of mortality and technique failure in peritoneal dialysis patients after critical illness","volume":"32","author":"Khan","year":"2012","journal-title":"Perit Dial Int."},{"issue":"1","key":"B58-20260428","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1111\/hdi.12550","article-title":"Safety of arteriovenous fistulae and grafts for continuous renal replacement therapy: the Michigan experience","volume":"22","author":"Al Rifai","year":"2018","journal-title":"Hemodial Int."},{"issue":"2","key":"B59-20260428","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1001\/jamainternmed.2017.4831","article-title":"Outcomes associated with left ventricular assist devices among recipients with and without end-stage renal disease","volume":"178","author":"Bansal","year":"2018","journal-title":"JAMA Intern Med."},{"issue":"14","key":"B60-20260428","doi-asserted-by":"crossref","first-page":"e008664","DOI":"10.1161\/JAHA.118.008664","article-title":"Implantable ventricular assist device use and outcomes in people with end-stage renal disease","volume":"7","author":"Walther","year":"2018","journal-title":"J Am Heart Assoc."},{"issue":"11","key":"B61-20260428","doi-asserted-by":"crossref","first-page":"2304","DOI":"10.1002\/ejhf.3323","article-title":"Right heart failure with left ventricular assist devices: preoperative, perioperative and postoperative management strategies. A clinical consensus statement of the Heart Failure Association (HFA) of the ESC","volume":"26","author":"Adamopoulos","year":"2024","journal-title":"Eur J Heart Fail."},{"issue":"16","key":"B62-20260428","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.1161\/CIRCULATIONAHA.122.062371","article-title":"Unloading the left ventricle in venoarterial ECMO: in whom, when, and how?","volume":"147","author":"Ezad","year":"2023","journal-title":"Circulation."},{"issue":"6","key":"B63-20260428","first-page":"559","article-title":"When to discontinue renal replacement therapy. What do we know?","volume":"29","author":"Boyer","year":"2023","journal-title":"Curr Opin Crit Care."},{"issue":"2","key":"B64-20260428","doi-asserted-by":"crossref","first-page":"579","DOI":"10.3390\/jcm13020579","article-title":"Weaning from kidney replacement therapy in the critically ill patient with acute kidney injury","volume":"13","author":"Klouche","year":"2024","journal-title":"J Clin Med."},{"issue":"1","key":"B65-20260428","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1186\/s13054-025-05517-1","article-title":"Liberation from continuous renal replacement therapy due to renal recovery in adults and children: a literature review and Delphi consensus on clinical practice","volume":"29","author":"Raina","year":"2025","journal-title":"Crit Care."},{"key":"B66-20260428","first-page":"e2521530","article-title":"A conservative dialysis strategy and kidney function recovery in dialysis-requiring acute kidney injury: the liberation from acute dialysis (LIBERATE-D) randomized clinical trial","author":"Liu","year":"2025","journal-title":"JAMA."},{"issue":"11","key":"B67-20260428","doi-asserted-by":"crossref","first-page":"1584","DOI":"10.1016\/j.cardfail.2022.04.016","article-title":"Outcomes in patients with LVADs undergoing simultaneous heart-kidney transplantation","volume":"28","author":"Atkins","year":"2022","journal-title":"J Card Fail."},{"issue":"6","key":"B68-20260428","doi-asserted-by":"crossref","first-page":"4425","DOI":"10.1002\/ehf2.13590","article-title":"HFA of the ESC position paper on the management of LVAD\u2010supported patients for the non\u2010LVAD specialist healthcare provider part 3: at the hospital and discharge","volume":"8","author":"Gustafsson","year":"2021","journal-title":"ESC Heart Fail."},{"issue":"2","key":"B69-20260428","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1053\/j.ajkd.2020.04.018","article-title":"Outcomes among patients with left ventricular assist devices receiving maintenance outpatient hemodialysis: a case series","volume":"77","author":"Franz","year":"2021","journal-title":"Am J Kidney Dis."},{"issue":"8 Pt 1","key":"B70-20260428","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1016\/j.jchf.2023.04.014","article-title":"Late right heart failure after left ventricular assist devace implantation: contemporary insights and future perspectives","volume":"11","author":"Rajapreyar","year":"2023","journal-title":"JACC Heart Fail."},{"issue":"2","key":"B71-20260428","doi-asserted-by":"crossref","first-page":"e005094","DOI":"10.1161\/CIRCHEARTFAILURE.118.005094","article-title":"Optimal hemodynamics during left ventricular assist device support are associated with reduced readmission rates","volume":"12","author":"Imamura","year":"2019","journal-title":"Circ Heart Fail."},{"issue":"3","key":"B72-20260428","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.jchf.2015.10.001","article-title":"Hemodynamic ramp tests in patients with left ventricular assist devices","volume":"4","author":"Uriel","year":"2016","journal-title":"JACC Heart Fail."},{"issue":"2","key":"B73-20260428","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1177\/1129729819865706","article-title":"Maturation of arteriovenous fistulas in patients with ventricular assist devices","volume":"21","author":"Salem","year":"2020","journal-title":"J Vasc Access."},{"issue":"2","key":"B74-20260428","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1053\/j.ajkd.2016.07.032","article-title":"Successful hemodialysis arteriovenous fistula creation in a patient with continuous-flow left ventricular assist device support","volume":"69","author":"Chin","year":"2017","journal-title":"Am J Kidney Dis."},{"issue":"6","key":"B75-20260428","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1016\/j.xkme.2021.07.004","article-title":"Successful use of arteriovenous graft for hemodialysis access after left ventricular assist device placement","volume":"3","author":"Toma","year":"2021","journal-title":"Kidney Med."},{"key":"B76-20260428","doi-asserted-by":"crossref","first-page":"568.e13","DOI":"10.1016\/j.avsg.2020.08.120","article-title":"Considerations for long-term dialysis access in patients with left ventricular assist devices","volume":"70","author":"Safaya","year":"2021","journal-title":"Ann Vasc Surg."},{"issue":"3","key":"B77-20260428","doi-asserted-by":"crossref","first-page":"E54","DOI":"10.1111\/hdi.12533","article-title":"Native arteriovenous fistula placement in three patients after implantation of a left ventricular assist device with non-pulsatile blood flow","volume":"21","author":"Schaefers","year":"2017","journal-title":"Hemodial Int."},{"issue":"3","key":"B78-20260428","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1053\/j.ackd.2020.03.006","article-title":"Vessel preservation in chronic kidney disease","volume":"27","author":"Vachharajani","year":"2020","journal-title":"Adv Chronic Kidney Dis."},{"issue":"5","key":"B79-20260428","doi-asserted-by":"crossref","first-page":"e000074","DOI":"10.1161\/HHF.0000000000000074","article-title":"Management of hypertension in patients with ventricular assist devices: a scientific statement from the American Heart Association","volume":"15","author":"Eisen","year":"2022","journal-title":"Circ Heart Fail."},{"issue":"1","key":"B80-20260428","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.ccc.2023.06.004","article-title":"Left ventricular assist device emergencies: diagnosis and management","volume":"40","author":"Sennhauser","year":"2024","journal-title":"Crit Care Clin."},{"issue":"11","key":"B81-20260428","doi-asserted-by":"crossref","first-page":"1928","DOI":"10.1016\/j.jchf.2024.03.004","article-title":"Safety of chest compressions in patients with a durable left ventricular assist device","volume":"12","author":"Senman","year":"2024","journal-title":"JACC Heart Fail."},{"issue":"11","key":"B82-20260428","doi-asserted-by":"crossref","first-page":"1931","DOI":"10.1016\/j.jchf.2024.08.021","article-title":"Cardiopulmonary resuscitation in patients with left ventricular assist devices: a call to action","volume":"12","author":"Vierecke","year":"2024","journal-title":"JACC Heart Fail."},{"issue":"6","key":"B83-20260428","doi-asserted-by":"crossref","first-page":"e270","DOI":"10.1097\/MAT.0000000000001850","article-title":"Feasibility of outpatient hemodialysis for patients with total artificial heart: a case series","volume":"69","author":"Gopalan","year":"2023","journal-title":"Asaio j"},{"issue":"12","key":"B84-20260428","doi-asserted-by":"crossref","first-page":"1646","DOI":"10.2215\/CJN.0000000000000410","article-title":"Home dialysis in patients with cardiovascular diseases","volume":"19","author":"Reaves","year":"2024","journal-title":"Clin J Am Soc Nephrol."},{"issue":"3","key":"B85-20260428","doi-asserted-by":"crossref","first-page":"E36","DOI":"10.1111\/hdi.12631","article-title":"Left ventricular assist device patient maintained on home hemodialysis: a novel class of patients to the home dialysis population","volume":"22","author":"Hanna","year":"2018","journal-title":"Hemodial Int."},{"issue":"9","key":"B86-20260428","first-page":"792","article-title":"HVAD: The ENDURANCE Supplemental Trial","volume":"6","author":"Milano","year":"2018","journal-title":"JACC: Heart Fail."},{"issue":"11","key":"B87-20260428","doi-asserted-by":"crossref","first-page":"e146","DOI":"10.1161\/CIR.0000000000001088","article-title":"Cardiovascular effects of home dialysis therapies: a scientific statement from the American Heart Association","volume":"146","author":"Sarnak","year":"2022","journal-title":"Circulation."},{"issue":"3","key":"B88-20260428","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1177\/08968608221126856","article-title":"Peritoneal dialysis and LVAD bridge to successful heart-kidney transplant","volume":"43","author":"Forcey","year":"2023","journal-title":"Perit Dial Int."},{"issue":"6","key":"B89-20260428","doi-asserted-by":"crossref","first-page":"1062","DOI":"10.1111\/aor.14970","article-title":"Peritoneal dialysis in patients supported by left ventricular assist device","volume":"49","author":"Darbaidze","year":"2025","journal-title":"Artif Organs."},{"issue":"1","key":"B90-20260428","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1097\/MAT.0000000000000020","article-title":"Peritoneal dialysis after left ventricular assist device placement","volume":"60","author":"Guglielmi","year":"2014","journal-title":"ASAIO J."},{"issue":"3","key":"B91-20260428","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1016\/j.xkme.2020.12.009","article-title":"Peritoneal dialysis following left ventricular assist device placement and kidney recovery: a case report","volume":"3","author":"Ajuria","year":"2021","journal-title":"Kidney Med."},{"issue":"9","key":"B92-20260428","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1016\/j.healun.2023.04.013","article-title":"Presence and impact of anemia in patients supported with left ventricular assist devices","volume":"42","author":"Tie","year":"2023","journal-title":"J Heart Lung Transplant."},{"key":"B93-20260428","doi-asserted-by":"crossref","first-page":"e08","DOI":"10.15420\/cfr.2023.26","article-title":"Iron deficiency in patients with left ventricular assist devices","volume":"10","author":"Nielsen","year":"2024","journal-title":"Card Fail Rev."},{"issue":"13","key":"B94-20260428","doi-asserted-by":"crossref","first-page":"3900","DOI":"10.3390\/jcm11133900","article-title":"Safety and effectiveness of intravenous iron therapy in patients supported by durable left ventricular assist devices","volume":"11","author":"Peters","year":"2022","journal-title":"J Clin Med."},{"issue":"25","key":"B95-20260428","doi-asserted-by":"crossref","first-page":"e1145","DOI":"10.1161\/CIR.0000000000000507","article-title":"Recommendations for the use of mechanical circulatory support: ambulatory and community patient care: a scientific statement from the American Heart Association","volume":"135","author":"Cook","year":"2017","journal-title":"Circulation."},{"issue":"2","key":"B96-20260428","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1161\/CIRCULATIONAHA.118.037231","article-title":"Comprehensive analysis of stroke in the long-term cohort of the MOMENTUM 3 study","volume":"139","author":"Colombo","year":"2019","journal-title":"Circulation."},{"issue":"2","key":"B97-20260428","first-page":"146","article-title":"Clinical outcomes with use of erythropoiesis stimulating agents in patients with the HeartMate II left ventricular assist device","volume":"3","author":"Nassif","year":"2015","journal-title":"JACC: Heart Fail."},{"issue":"3","key":"B98-20260428","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1053\/j.ajkd.2019.10.010","article-title":"Critical care nephrology: core curriculum 2020","volume":"75","author":"Griffin","year":"2020","journal-title":"Am J Kidney Dis."},{"key":"B99-20260428","doi-asserted-by":"crossref","first-page":"154895","DOI":"10.1016\/j.jcrc.2024.154895","article-title":"Outcomes of continuous renal replacement therapy versus peritoneal dialysis as a renal replacement therapy modality in patients undergoing venoarterial extracorporeal membrane oxygenation","volume":"84","author":"Thanapongsatorn","year":"2024","journal-title":"J Crit Care."},{"issue":"7","key":"B100-20260428","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1016\/j.jchf.2024.03.020","article-title":"Practical guidance for hemodynamic assessment by right heart catheterization in management of heart failure","volume":"12","author":"Rajagopalan","year":"2024","journal-title":"JACC Heart Failure."},{"issue":"5","key":"B101-20260428","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/j.cardfail.2021.11.016","article-title":"Physiology and clinical utility of HeartMate pump parameters","volume":"28","author":"Belkin","year":"2022","journal-title":"J Card Fail."}],"container-title":["Journal of the American Society of Nephrology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1681\/ASN.0000001013","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T19:25:16Z","timestamp":1786130716000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1681\/ASN.0000001013"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,24]]},"references-count":100,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1681\/asn.0000001013","relation":{},"ISSN":["1046-6673","1533-3450"],"issn-type":[{"value":"1046-6673","type":"print"},{"value":"1533-3450","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,24]]}}}