{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T20:31:24Z","timestamp":1791405084290,"version":"4.3.3"},"reference-count":7,"publisher":"The Korean Society of Anesthesiologists","issue":"3","license":[{"start":{"date-parts":[[2020,7,31]],"date-time":"2020-07-31T00:00:00Z","timestamp":1596153600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"name":"MEKICS Co."}],"content-domain":{"domain":["anesth-pain-med.org"],"crossmark-restriction":true},"short-container-title":["Anesth Pain Med"],"published-print":{"date-parts":[[2020,7,31]]},"abstract":"<jats:p>Background: The performance of the pulse oximeter was evaluated based on the ISO 80601-2-61:2011 (E) guidelines. This study aimed to determine whether the various finger probes of the MP570T pulse oximeter (MEK-ICS Co., Ltd., Korea) would provide clinically reliable peripheral oxygen saturation (SpO2) readings over a range of 70\uf02d100% arterial oxygen saturation (SaO2) during non-motion conditions.Methods: Each volunteer (n = 12) was connected to a breathing circuit for the administration of a hypoxic gas mixture. For frequent blood sampling, an arterial cannula was placed in a radial artery. The following seven pulse oximeter probes were simultaneously attached to each volunteer\u2019s fingers: (1) WA-100 reusable finger probe (MEDNIS Co., Ltd., Korea), (2) MDNA disposable finger probe (MEDNIS Co., Ltd.), (3) IS-1011 disposable finger probe (Insung Medical Co., Ltd., Korea), (4) CJ340NA disposable finger probe (CHUN JI IN Medical Co., Ltd., Korea), (5) NellcorTM OxiMax DS-100A reusable finger probe (Medtronic, USA), (6) NellcorTM OxiMax MAX-N disposable finger probe (Medtronic), and (7) OXI-PRO DA disposable finger probe (Bio-Protech Inc., Korea). Results: A total of 275 SpO2-SaO2 pairs were included in the analysis. The accuracy of the root mean square (Arms) of each probe was 2.83%, 3.98%, 3.75%, 6.84%, 3.43%, 5.17%, and 3.84%, respectively.Conclusions: The MP570T pulse oximeter with WA-100 reusable, MDNA disposable, IS-1011 disposable, NellcorTM OxiMax DS-100A reusable, and OXI-PRO DA disposable finger probes meets an acceptable standard of SpO2 accuracy under non-motion conditions.<\/jats:p>","DOI":"10.17085\/apm.20028","type":"journal-article","created":{"date-parts":[[2020,7,31]],"date-time":"2020-07-31T02:09:11Z","timestamp":1596161351000},"page":"371-377","update-policy":"https:\/\/doi.org\/10.17085\/crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Performance of the MP570T pulse oximeter in volunteers participating in the controlled desaturation study: a comparison of seven probes"],"prefix":"10.17085","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6561-8851","authenticated-orcid":true,"given":"Byung-Moon","family":"Choi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4736-797X","authenticated-orcid":true,"given":"Bong Jin","family":"Kang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8599-4750","authenticated-orcid":true,"given":"Ho-Yong","family":"Yun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3280-8429","authenticated-orcid":true,"given":"Bokyoung","family":"Jeon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1031-9539","authenticated-orcid":true,"given":"Ji-Yeon","family":"Bang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1964-9294","authenticated-orcid":true,"given":"Gyu-Jeong","family":"Noh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2573","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1186\/s13054-015-0984-8"},{"key":"ref2","volume-title":""},{"key":"ref3","volume-title":""},{"key":"ref4","volume-title":"","author":"Matthes","year":"2013"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2011.07021.x"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-200504000-00004"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1213\/01.ane.0000285988.35174.d9"}],"container-title":["Anesthesia and Pain Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/anesth-pain-med.org\/upload\/pdf\/apm-20028.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/anesth-pain-med.org\/journal\/view.php?doi=10.17085\/apm.20028","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/anesth-pain-med.org\/upload\/pdf\/apm-20028.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,31]],"date-time":"2020-07-31T02:10:58Z","timestamp":1596161458000},"score":1,"resource":{"primary":{"URL":"http:\/\/anesth-pain-med.org\/journal\/view.php?doi=10.17085\/apm.20028"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,31]]},"references-count":7,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020,7]]}},"URL":"https:\/\/doi.org\/10.17085\/apm.20028","relation":{},"ISSN":["1975-5171","2383-7977"],"issn-type":[{"value":"1975-5171","type":"print"},{"value":"2383-7977","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,31]]},"assertion":[{"value":"2020-04-06","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-05-13","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-07-31","order":2,"name":"published","label":"Published online","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-07-31","order":3,"name":"published","label":"Print publication","group":{"name":"publication_history","label":"Publication History"}}]}}