{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T13:31:41Z","timestamp":1788787901077,"version":"build-2803163510"},"reference-count":22,"publisher":"The Korean Society of Anesthesiologists","issue":"3","license":[{"start":{"date-parts":[[2021,4,23]],"date-time":"2021-04-23T00:00:00Z","timestamp":1619136000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100006017","name":"College of Pharmacy, Keimyung University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100006017","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["anesth-pain-med.org"],"crossmark-restriction":true},"short-container-title":["Anesth Pain Med"],"published-print":{"date-parts":[[2021,7,31]]},"abstract":"<jats:p>Background: Robot-assisted laparoscopic radical prostatectomy is an advanced and popular surgical technique. However, increased intracranial pressure which is caused by CO2 pneumoperitoneum and Trendelenburg position is the main cerebrovascular effect. Measurement of optic nerve sheath diameter using ocular ultrasound is a noninvasive and reliable method for the assessment of intracranial pressure. The primary endpoint of this study was to identify whether low blood pressure regulation has any benefit in attenuating an increase of optic nerve sheath diameter during robot-assisted laparoscopic radical prostatectomy.Methods: Optic nerve sheath diameter and cerebral oxygen saturation were measured at baseline (supine position), one and two hours after pneumoperitoneum and Trendelenburg position respectively, and after return to supine position in normal (n = 27) and low blood pressure groups (n = 24).Results: Mean optic nerve sheath diameter values measured at one and two hours after pneumoperitoneum and Trendelenburg position were significantly increased compared to the baseline value (P &lt; 0.001 in normal blood pressure group; P = 0.003 in low blood pressure group). However, the mean optic nerve sheath diameter and cerebral oxygen saturation measured at any of the time points as well as degrees of change between the two groups did not show any significant changes. The peak values of optic nerve sheath diameter in normal and low blood pressure groups demonstrated 14.9% and 9.2% increases, respectively.Conclusions: Low blood pressure group demonstrated an effect in maintaining an increase of optic nerve sheath diameter less than 10% during CO2 pneumoperitoneum and Trendelenburg position.<\/jats:p>","DOI":"10.17085\/apm.20097","type":"journal-article","created":{"date-parts":[[2021,4,23]],"date-time":"2021-04-23T01:13:23Z","timestamp":1619140403000},"page":"248-257","update-policy":"https:\/\/doi.org\/10.17085\/crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Comparison of the effects of normal and low blood pressure regulation on the optic nerve sheath diameter in robot assisted laparoscopic radical prostatectomy"],"prefix":"10.17085","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4776-5206","authenticated-orcid":true,"given":"Ji Hoon","family":"Park","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6679-3088","authenticated-orcid":true,"given":"Ji Hee","family":"Hong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8273-8644","authenticated-orcid":true,"given":"Ji Seob","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6518-3755","authenticated-orcid":true,"given":"Hyung Jun","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2573","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1089\/end.2014.0019"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1097\/ana.0000000000000106"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1097\/md.0000000000012772"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1097\/md.0000000000015051"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1155\/2019\/5617815"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-018-5305-7"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1111\/ane.12527"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pmed.1002356"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.5777"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1007\/s00381-017-3454-6"},{"key":"ref11","first-page":"1066","volume-title":"Optic nerve sheath diameter used as ultrasonographic assessment of the incidence of raised intracranial pressure in preeclampsia: a pilot study","author":"Dubost","year":"2012"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1097\/md.0000000000005061"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aex078"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1007\/s00381-016-3067-5"},{"key":"ref15","first-page":"432","volume-title":"Assessment of intra-interobserver reliability of the sonographic optic nerve sheath diameter measurement","author":"Cimilli Ozturk","year":"2015"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1186\/s12871-019-0736-4"},{"key":"ref17","first-page":"E325","volume-title":"The effect of speed of normal saline injection on optic nerve sheath diameter in thoracic epidural anesthesia","author":"Hong","year":"2019"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.2011.02432.x"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0043172"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2008.05636.x"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1177\/0271678x16648711"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1089\/end.2019.0217"}],"container-title":["Anesthesia and Pain Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/anesth-pain-med.org\/upload\/pdf\/apm-20097.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/anesth-pain-med.org\/journal\/view.php?doi=10.17085\/apm.20097","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/anesth-pain-med.org\/upload\/pdf\/apm-20097.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,30]],"date-time":"2021-07-30T04:54:33Z","timestamp":1627620873000},"score":1,"resource":{"primary":{"URL":"http:\/\/anesth-pain-med.org\/journal\/view.php?doi=10.17085\/apm.20097"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7,31]]},"references-count":22,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,7]]}},"URL":"https:\/\/doi.org\/10.17085\/apm.20097","relation":{},"ISSN":["1975-5171","2383-7977"],"issn-type":[{"value":"1975-5171","type":"print"},{"value":"2383-7977","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,7,31]]},"assertion":[{"value":"2020-12-15","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-02-22","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-04-23","order":2,"name":"published","label":"Published online","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-07-31","order":3,"name":"published","label":"Print publication","group":{"name":"publication_history","label":"Publication History"}}]}}