{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T05:23:33Z","timestamp":1747200213881,"version":"3.40.5"},"reference-count":45,"publisher":"Media Sphere Publishing House","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Rus. Ann. Ophthal."],"published-print":{"date-parts":[[2024,4,23]]},"abstract":"<jats:p>Purpose. This study investigates the influence of peripheral corneal thickness (PCT) and its curvature on tonometry readings. Material and methods. The study included 49 patients (49 eyes) who were indicated for glaucoma surgery. Using bidirectional applanation tonometry, the following parameters were obtained: IOPcc, IOPg \u2014 intraocular pressure (IOP) corrected for corneal compensation, taken as the most reliable indicator; IOP converted to Goldmann measurement, taken as the result of applanation tonometry, \u0394IOP (IOPcc\u2014IOPg), CH and CRF (corneal hysteresis and corneal resistance factor). During corneal topography, the corneal thickness was studied in the center, PCT at 1.5; 2, 3, 4 and 5 mm from the center in four meridians, as well as \u0394PCT (PCT 3 mm \u2014 PCT 1.5 mm), the curvature of the anterior and posterior surfaces of the cornea and the depth of the anterior chamber. Aberrometry was used to obtain refractometry data and the curvature of the anterior surface of the cornea. The influence of the studied parameters on \u0394IOP was evaluated. Results. \u0394IOP correlated with CRF (r= \u20130.652), CH (r= \u20130.873), central corneal thickness (r= \u20130.293), PCT at all distances except 5 mm (r= \u20130.297; \u20130.287; \u20130.302; \u20130.303), with the strong and weak meridians of the anterior surface of the cornea (r=0.328; r=0.315), with the strong and weak meridians of the posterior surface, as well as the average curvature of the posterior surface (r=0.307; r=0.332; r=0.328). After step-by-step selection of the above parameters for creating a linear regression model for \u0394IOP calculation, CH, CRF and PCT1.5mm remained in the model. The model describes \u0394IOP with high accuracy (R2=0.974). Conclusion. Biomechanical parameters of the cornea are the leading factor of applanation tonometry error. Individual linear dimensions of the cornea (thickness, curvature) have a lesser effect.<\/jats:p>","DOI":"10.17116\/oftalma202414002243","type":"journal-article","created":{"date-parts":[[2024,5,13]],"date-time":"2024-05-13T15:03:15Z","timestamp":1715612595000},"page":"43","source":"Crossref","is-referenced-by-count":0,"special_numbering":"Vyp. 2","title":["Influence of corneal curvature and peripheral thickness on tonometry readings"],"prefix":"10.17116","volume":"140","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5171-8261","authenticated-orcid":false,"given":"A.A.","family":"Antonov","sequence":"first","affiliation":[{"name":"Krasnov Research Institute of Eye Diseases","place":["Moscow, Russia"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1421-8882","authenticated-orcid":false,"given":"A.V.","family":"Volzhanin","sequence":"additional","affiliation":[{"name":"Krasnov Research Institute of Eye Diseases","place":["Moscow, Russia"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9744-0149","authenticated-orcid":false,"given":"E.A.","family":"Klinicheva","sequence":"additional","affiliation":[{"name":"Krasnov Research Institute of Eye Diseases","place":["Moscow, Russia"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0385-3976","authenticated-orcid":false,"given":"M.A.","family":"Karpilova","sequence":"additional","affiliation":[{"name":"Krasnov Research Institute of Eye Diseases","place":["Moscow, Russia"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"6743","reference":[{"key":"key-10.17116\/oftalma202414002243-1","doi-asserted-by":"publisher","DOI":"10.1016\/S2214-109X(20)30489-7"},{"key":"key-10.17116\/oftalma202414002243-2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2014.05.013"},{"key":"key-10.17116\/oftalma202414002243-3","doi-asserted-by":"publisher","DOI":"10.1159\/000303213"},{"key":"key-10.17116\/oftalma202414002243-4","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.1975.tb01135.x"},{"key":"key-10.17116\/oftalma202414002243-5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.09.031"},{"key":"key-10.17116\/oftalma202414002243-6","doi-asserted-by":"crossref","unstructured":"Bauer SM, Voronkova EB. Models of shells and plates in the problems of ophthalmology. Vestnik of Saint Petersburg University. Mathematics. Mechanics. Astronomy. 2014;1(3):438-458","DOI":"10.3103\/S1063454114030029"},{"key":"key-10.17116\/oftalma202414002243-7","doi-asserted-by":"publisher","DOI":"10.1016\/s0002-9394(14)72611-x"},{"key":"key-10.17116\/oftalma202414002243-8","doi-asserted-by":"publisher","DOI":"10.1364\/josaa.14.001684"},{"key":"key-10.17116\/oftalma202414002243-9","unstructured":"Gatinel D, Haouat M, Hoang-Xuan T. A review of mathematical descriptors of corneal asphericity. J Fr Ophtalmol. 2002;25(1):81-90"},{"key":"key-10.17116\/oftalma202414002243-10","doi-asserted-by":"publisher","DOI":"10.5935\/0004-2749.20140016"},{"key":"key-10.17116\/oftalma202414002243-11","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2016.08.011"},{"key":"key-10.17116\/oftalma202414002243-12","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2016.06.008"},{"key":"key-10.17116\/oftalma202414002243-13","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.06.047"},{"key":"key-10.17116\/oftalma202414002243-14","doi-asserted-by":"publisher","DOI":"10.1016\/s0002-9394(03)00424-0"},{"key":"key-10.17116\/oftalma202414002243-15","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2006.01266.x"},{"key":"key-10.17116\/oftalma202414002243-16","doi-asserted-by":"publisher","DOI":"10.1097\/01.ico.0000164833.69668.02"},{"key":"key-10.17116\/oftalma202414002243-17","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0140385"},{"key":"key-10.17116\/oftalma202414002243-18","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0b013e31806ab33e"},{"key":"key-10.17116\/oftalma202414002243-19","doi-asserted-by":"publisher","DOI":"10.3928\/01913913-20070701-02"},{"key":"key-10.17116\/oftalma202414002243-20","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.56.8.624"},{"key":"key-10.17116\/oftalma202414002243-21","unstructured":"Vyazovsky IA. Improvement of the technique of photographing the optical slices of the cornea and lens. Journal of Ophthalmology. 1961;16(4):227-232. (In Russ.)"},{"key":"key-10.17116\/oftalma202414002243-22","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.1990.tb00886.x"},{"key":"key-10.17116\/oftalma202414002243-23","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199707000-00016"},{"key":"key-10.17116\/oftalma202414002243-24","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2015.05.001"},{"key":"key-10.17116\/oftalma202414002243-25","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2014-306340"},{"key":"key-10.17116\/oftalma202414002243-26","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.08.040"},{"key":"key-10.17116\/oftalma202414002243-27","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2011.07.004"},{"key":"key-10.17116\/oftalma202414002243-28","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.1992.tb04133.x"},{"key":"key-10.17116\/oftalma202414002243-29","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2005.09.021"},{"key":"key-10.17116\/oftalma202414002243-30","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000000595"},{"key":"key-10.17116\/oftalma202414002243-31","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2016.05.004"},{"key":"key-10.17116\/oftalma202414002243-32","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0176913"},{"key":"key-10.17116\/oftalma202414002243-33","doi-asserted-by":"publisher","DOI":"10.1016\/j.optom.2013.03.005"},{"key":"key-10.17116\/oftalma202414002243-34","doi-asserted-by":"crossref","unstructured":"Rukov SA, Kondratenko YuN, Novitskiy AN, Kisil AR.The investigation of the central, paracentral and peripheral thickness of the cornea as risk factors of progressing of primary open-angle glaucoma in the long-term follow-up. Journal of Ophthalmology. 2011;(6(443)):15-20. (In Russ)","DOI":"10.31288\/oftalmolzh201161520"},{"key":"key-10.17116\/oftalma202414002243-35","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-005-0053-0"},{"key":"key-10.17116\/oftalma202414002243-36","doi-asserted-by":"publisher","DOI":"10.1590\/s0004-27492006000100009"},{"key":"key-10.17116\/oftalma202414002243-37","doi-asserted-by":"publisher","DOI":"10.15593\/RZhBiomeh\/2019.1.01"},{"key":"key-10.17116\/oftalma202414002243-38","doi-asserted-by":"publisher","DOI":"10.1134\/S0006302919050272"},{"key":"key-10.17116\/oftalma202414002243-39","unstructured":"Bauer SM, Karamshina LA, Kachanov AB. Mechanical models of the measurements of intraocular pressure by Goldmann and Maklakov applanation tonometers after refractive surgery. Russian Journal of Biomechanics. 2012; 16(3(57)):25-31. (In Russ.)"},{"key":"key-10.17116\/oftalma202414002243-40","doi-asserted-by":"publisher","DOI":"10.1097\/01.icl.0000246910.02437.62"},{"key":"key-10.17116\/oftalma202414002243-41","doi-asserted-by":"crossref","unstructured":"Lam AK, Douthwaite WA. The effect of an artificially elevated intraocular pressure on the central corneal curvature. Ophthalmic Physiol Opt. 1997; 17(1):18-24","DOI":"10.1046\/j.1475-1313.1997.96000336.x"},{"key":"key-10.17116\/oftalma202414002243-42","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9394(89)90005-6"},{"key":"key-10.17116\/oftalma202414002243-43","doi-asserted-by":"publisher","DOI":"10.3390\/vision4040045"},{"key":"key-10.17116\/oftalma202414002243-44","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.2009.00414.x"},{"key":"key-10.17116\/oftalma202414002243-45","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.2011.00591.x"}],"container-title":["Russian Annals of Ophthalmology"],"original-title":[],"language":"en","deposited":{"date-parts":[[2025,4,23]],"date-time":"2025-04-23T08:40:17Z","timestamp":1745397617000},"score":1,"resource":{"primary":{"URL":"https:\/\/mediasphera.ru\/issues\/vestnik-oftalmologii\/2024\/2-2\/10042465X2024022043"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,23]]},"references-count":45,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,6,10]]}},"alternative-id":["10.17116\/oftalma202414002243"],"URL":"https:\/\/doi.org\/10.17116\/oftalma202414002243","relation":{},"ISSN":["0042-465X"],"issn-type":[{"type":"print","value":"0042-465X"}],"subject":[],"published":{"date-parts":[[2024,4,23]]}}}