{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,3]],"date-time":"2025-10-03T12:54:53Z","timestamp":1759496093327,"version":"3.40.5"},"reference-count":30,"publisher":"Media Sphere Publishing House","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Rus. Ann. Ophthal."],"published-print":{"date-parts":[[2024,4,23]]},"abstract":"<jats:p>Congenital subluxation of the lens as a complication of Marfan syndrome, Weill\u2014Marchesani syndrome, microspherophakia, etc. leads to the development of amblyopia and requires timely surgical treatment with removal of the subluxated lens and implantation of an artificial intraocular lens (IOL). IOL implantation in children with pathology of the ligamentous apparatus of the lens remains an urgent problem of ophthalmic surgery due to the lack of a consensus regarding the IOL fixation method among practitioners. Purpose. This study evaluated the effectiveness and safety of IOL implantation with transscleral fixation using the knotless Z-suture technique in pediatric patients with congenital lens subluxation. Material and methods. The study included 24 children (36 eyes) with grade III congenital subluxation of the lens who underwent phacoaspiration of the subluxated lens with IOL implantation with transscleral fixation using the knotless Z-suture performed in the Kazakh Research Institute of Eye Diseases in Almaty in the period from 2017 to 2021. The average observation period was 31.7\u00b111.3 months (2.0 to 4.5 years). The stability of the IOL position, the state of the intrascleral sutures, visual acuity after surgery, the presence and severity of complications in the long-term period were evaluated. Results. All patients (100%) had a significant improvement in visual acuity after surgery. No intraoperative complications were registered in any of the cases. Postoperative complications were noted in 8.3% of cases (n=3). The final functional outcome of surgical treatment depended on the presence of concomitant pathology, the main cause of low vision was the development of refractive amblyopia due to refractive errors. Conclusions. The presented technique of transscleral fixation of IOL has proven to be reliable, which is especially important for pediatric patients considering their high physical activity and expected lifespan.<\/jats:p>","DOI":"10.17116\/oftalma202414003127","type":"journal-article","created":{"date-parts":[[2024,7,4]],"date-time":"2024-07-04T10:09:23Z","timestamp":1720087763000},"page":"27","source":"Crossref","is-referenced-by-count":1,"title":["Transscleral fixation of intraocular lens in the treatment of lens subluxation in children"],"prefix":"10.17116","volume":"140","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0315-7332","authenticated-orcid":false,"given":"L.N.","family":"Orazbekov","sequence":"first","affiliation":[{"name":"Kazakh Research Institute of Eye Diseases","place":["Almaty, Kazakhstan"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-0953-5091","authenticated-orcid":false,"given":"A.A.","family":"Shabanova","sequence":"additional","affiliation":[{"name":"Asfendiyarov Kazakh National Medical University","place":["Almaty, Kazakhstan"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"6743","reference":[{"key":"key-10.17116\/oftalma202414003127-1","doi-asserted-by":"publisher","DOI":"10.33029\/9704-6145-7-OFT-2021-1-304"},{"key":"key-10.17116\/oftalma202414003127-2","doi-asserted-by":"publisher","DOI":"10.25276\/2307-6658-2022-4-16-26"},{"key":"key-10.17116\/oftalma202414003127-3","doi-asserted-by":"publisher","DOI":"10.17116\/oftalma2019135031104"},{"key":"key-10.17116\/oftalma202414003127-4","doi-asserted-by":"publisher","DOI":"10.1007\/BF00159844"},{"key":"key-10.17116\/oftalma202414003127-5","doi-asserted-by":"publisher","DOI":"10.1097\/00004397-199403430-00009"},{"key":"key-10.17116\/oftalma202414003127-6","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2017.02.026"},{"key":"key-10.17116\/oftalma202414003127-7","doi-asserted-by":"publisher","DOI":"10.3928\/1542-8877-19940801-15"},{"key":"key-10.17116\/oftalma202414003127-8","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2005.06.010"},{"key":"key-10.17116\/oftalma202414003127-9","unstructured":"Tahchidi HP, Egorova JeV, Tolchinskaja AI. Intraokuljarnaja korrekcija v hirurgii oslozhnennyh katarakt [Intraocular correction in surgery of complicated cataracts]. M.: Novoe v medicine; 2004. (In Russ.)"},{"key":"key-10.17116\/oftalma202414003127-10","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2009.162180"},{"key":"key-10.17116\/oftalma202414003127-11","doi-asserted-by":"publisher","DOI":"10.18008\/1816-5095-2017-4-291-298"},{"key":"key-10.17116\/oftalma202414003127-12","doi-asserted-by":"publisher","DOI":"10.1016\/s0161-6420(95)31033-0"},{"key":"key-10.17116\/oftalma202414003127-13","unstructured":"Belonozhenko JaV, Sorokin EL. The study of the clinical effectiveness of its own method of IOL implantation when performing age-related cataract phacoemulsification in patients with mild lens subluxation. Sovremennye tehnologii kataraktal\u2019noj i refrakcionnoj hirurgii. 2012;(1):31-37. (In Russ.)"},{"key":"key-10.17116\/oftalma202414003127-14","doi-asserted-by":"publisher","DOI":"10.17116\/oftalma2019135052235"},{"key":"key-10.17116\/oftalma202414003127-15","unstructured":"Pashtaev NP, Mihajlova VI, Bat\u2019kov EN. Modification of the pupillary IOL to reduce the risk of dislocation in case of insufficiency of the capsular ligamentous apparatus of the lens. Sovremennyye tekhnologii v oftal\u2019mologii. 2015;(4):82-86. (In Russ.)"},{"key":"key-10.17116\/oftalma202414003127-16","doi-asserted-by":"publisher","DOI":"10.1016\/s0002-9394(14)75878-7"},{"key":"key-10.17116\/oftalma202414003127-17","doi-asserted-by":"publisher","DOI":"10.1038\/eye.1995.190"},{"key":"key-10.17116\/oftalma202414003127-18","doi-asserted-by":"publisher","DOI":"10.3928\/1542-8877-19911101-14"},{"key":"key-10.17116\/oftalma202414003127-19","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.05.029"},{"key":"key-10.17116\/oftalma202414003127-20","doi-asserted-by":"publisher","DOI":"10.31288\/oftalmolzh20153912"},{"key":"key-10.17116\/oftalma202414003127-21","doi-asserted-by":"publisher","DOI":"10.17816\/OV12285-90"},{"key":"key-10.17116\/oftalma202414003127-22","doi-asserted-by":"crossref","unstructured":"Lindquist TD, Agapitos PJ, Lindstrom RL, et al. Transscleral fixation of posterior chamber intraocular lenses in the absence of capsular support. Ophthalmic Surg. 1989;20(11):769-775","DOI":"10.3928\/1542-8877-19891101-05"},{"key":"key-10.17116\/oftalma202414003127-23","doi-asserted-by":"publisher","DOI":"10.1016\/s0886-3350(13)80040-5"},{"key":"key-10.17116\/oftalma202414003127-24","doi-asserted-by":"publisher","DOI":"10.1007\/bf00203312"},{"key":"key-10.17116\/oftalma202414003127-25","doi-asserted-by":"publisher","DOI":"10.1016\/s0886-3350(13)80612-8"},{"key":"key-10.17116\/oftalma202414003127-26","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0b013e32834cd5e5"},{"key":"key-10.17116\/oftalma202414003127-27","doi-asserted-by":"publisher","DOI":"10.22608\/apo.2017158"},{"key":"key-10.17116\/oftalma202414003127-28","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-019-01181-x"},{"key":"key-10.17116\/oftalma202414003127-29","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.ijo_643_17"},{"key":"key-10.17116\/oftalma202414003127-30","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2017.03.036"}],"container-title":["Russian Annals of Ophthalmology"],"original-title":[],"language":"en","deposited":{"date-parts":[[2025,4,23]],"date-time":"2025-04-23T08:40:24Z","timestamp":1745397624000},"score":1,"resource":{"primary":{"URL":"https:\/\/mediasphera.ru\/issues\/vestnik-oftalmologii\/2024\/3\/10042465X2024031027"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,23]]},"references-count":30,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024,7,4]]}},"alternative-id":["10.17116\/oftalma202414003127"],"URL":"https:\/\/doi.org\/10.17116\/oftalma202414003127","relation":{},"ISSN":["0042-465X"],"issn-type":[{"type":"print","value":"0042-465X"}],"subject":[],"published":{"date-parts":[[2024,4,23]]}}}