{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T05:23:35Z","timestamp":1747200215680,"version":"3.40.5"},"reference-count":19,"publisher":"Media Sphere Publishing House","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Rus. Ann. Ophthal."],"published-print":{"date-parts":[[2024,4,23]]},"abstract":"<jats:p>Purpose. This study evaluates the effectiveness of implantation of extended depth of focus (EDOF) intraocular lenses (IOL) in patients with cataract and glaucoma. Material and methods. The study included 13 patients (16 eyes) who underwent implantation of the Lentis Comfort EDOF IOL (Teleon Surgical BV, Netherlands). Standard phacoemulsification cataract surgery with IOL implantation was performed in a planned manner after the hypotensive surgery stage in two eyes; a combined procedure was performed in 14 cases. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), near visual acuity, and intraocular pressure (IOP) measured with a Maklakov tonometer were assessed preoperatively, on the first day, and 3\u20146 months after surgery. Computer perimetry using the 30-2 program and spatial contrast sensitivity (SCS) assessment were also performed preoperatively and at the same follow-up time points. Results. On the first day after surgery, UCVA was 0.53\u00b10.65, BCVA was 0.85\u00b10.45. Near UCVA (at 40 cm) was 0.5\u00b10.14 on the first day after surgery and 0.56\u00b10.18 at 3\u20146 months. According to computer perimetry data, retinal light sensitivity values increased in all patients in the long-term (\u20133.1\u00b12.9 dB). SCS values increased for objects of all sizes compared to preoperative values. Conclusion. Implantation of EDOF IOL contributes to improved vision without reducing contrast sensitivity and retinal light sensitivity in patients with concomitant cataract and glaucoma.<\/jats:p>","DOI":"10.17116\/oftalma202414003170","type":"journal-article","created":{"date-parts":[[2024,7,4]],"date-time":"2024-07-04T10:09:23Z","timestamp":1720087763000},"page":"70","source":"Crossref","is-referenced-by-count":1,"title":["First experience of implantation of extended depth of focus intraocular lenses in patients with glaucoma"],"prefix":"10.17116","volume":"140","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7388-5634","authenticated-orcid":false,"given":"N.Yu.","family":"Gorbunova","sequence":"first","affiliation":[{"name":"Cheboksary branch of S.N Fedorov National Medical Research Center \u201cMNTK \u201cEye Microsurgery\u201d","place":["Cheboksary, Russia"]},{"name":"Postgraduate Doctors\u2019 Training Institute","place":["Cheboksary, Russia"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3238-2819","authenticated-orcid":false,"given":"R.A.","family":"Yakovlev","sequence":"additional","affiliation":[{"name":"Cheboksary branch of S.N Fedorov National Medical Research Center \u201cMNTK \u201cEye Microsurgery\u201d","place":["Cheboksary, Russia"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3637-3645","authenticated-orcid":false,"given":"N.A.","family":"Pozdeyeva","sequence":"additional","affiliation":[{"name":"Cheboksary branch of S.N Fedorov National Medical Research Center \u201cMNTK \u201cEye Microsurgery\u201d","place":["Cheboksary, Russia"]},{"name":"Postgraduate Doctors\u2019 Training Institute","place":["Cheboksary, Russia"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5375-8139","authenticated-orcid":false,"given":"N.O.","family":"Mikhailov","sequence":"additional","affiliation":[{"name":"Cheboksary branch of S.N Fedorov National Medical Research Center \u201cMNTK \u201cEye Microsurgery\u201d","place":["Cheboksary, Russia"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"6743","reference":[{"key":"key-10.17116\/oftalma202414003170-1","doi-asserted-by":"publisher","DOI":"10.29413\/ABS.2019-4.4.6"},{"key":"key-10.17116\/oftalma202414003170-2","doi-asserted-by":"publisher","DOI":"10.17116\/oftalma202013601125"},{"key":"key-10.17116\/oftalma202414003170-3","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00457-5"},{"key":"key-10.17116\/oftalma202414003170-4","doi-asserted-by":"publisher","DOI":"10.1016\/j.jfo.2011.02.003"},{"key":"key-10.17116\/oftalma202414003170-5","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0b013e3283365154"},{"key":"key-10.17116\/oftalma202414003170-6","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2014.04.017"},{"key":"key-10.17116\/oftalma202414003170-7","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2012.3486.x"},{"key":"key-10.17116\/oftalma202414003170-8","doi-asserted-by":"publisher","DOI":"10.25700\/NJG.2020.04.03"},{"key":"key-10.17116\/oftalma202414003170-9","doi-asserted-by":"publisher","DOI":"10.25276\/2312-4911-2020-4-150-151"},{"key":"key-10.17116\/oftalma202414003170-10","doi-asserted-by":"publisher","DOI":"10.17816\/OV10889"},{"key":"key-10.17116\/oftalma202414003170-11","doi-asserted-by":"publisher","DOI":"10.1016\/s0002-9394(14)77905-x"},{"key":"key-10.17116\/oftalma202414003170-12","doi-asserted-by":"publisher","DOI":"10.3349\/ymj.2007.48.4.627"},{"key":"key-10.17116\/oftalma202414003170-13","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-020-01435-z"},{"key":"key-10.17116\/oftalma202414003170-14","unstructured":"Chuprov AD, Gorbunov AA, Nikolaeva YuA. Study of spatial contrast sensitivity using the Zebra program to assess the quality of vision in patients after phacoemulsification of age-related cataracts with implantation of a Lentis Comfort multifocal IOL. Sovremennye tekhnologii v oftal\u2019mologii. 2018;(2): 250-252. (In Russ.)"},{"key":"key-10.17116\/oftalma202414003170-15","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-77214-8"},{"key":"key-10.17116\/oftalma202414003170-16","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.023772"},{"key":"key-10.17116\/oftalma202414003170-17","doi-asserted-by":"publisher","DOI":"10.1097\/00061198-200304000-00008"},{"key":"key-10.17116\/oftalma202414003170-18","doi-asserted-by":"publisher","DOI":"10.17116\/oftalma201813406146"},{"key":"key-10.17116\/oftalma202414003170-19","doi-asserted-by":"publisher","DOI":"10.17116\/oftalma2019135052278"}],"container-title":["Russian Annals of Ophthalmology"],"original-title":[],"language":"en","deposited":{"date-parts":[[2025,4,23]],"date-time":"2025-04-23T08:40:52Z","timestamp":1745397652000},"score":1,"resource":{"primary":{"URL":"https:\/\/mediasphera.ru\/issues\/vestnik-oftalmologii\/2024\/3\/10042465X2024031070"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,23]]},"references-count":19,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024,7,4]]}},"alternative-id":["10.17116\/oftalma202414003170"],"URL":"https:\/\/doi.org\/10.17116\/oftalma202414003170","relation":{},"ISSN":["0042-465X"],"issn-type":[{"type":"print","value":"0042-465X"}],"subject":[],"published":{"date-parts":[[2024,4,23]]}}}