{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T10:56:17Z","timestamp":1775472977452,"version":"3.50.1"},"reference-count":41,"publisher":"Medical Association of Zenica-Doboj","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medicinski Glasnik"],"published-print":{"date-parts":[[2016,6,30]]},"abstract":"<jats:p>&amp;lt;p&amp;gt;&amp;lt;strong&amp;gt;Aim &amp;lt;br \/&amp;gt;&amp;lt;\/strong&amp;gt;To evaluate the effectiveness and complication of vertebroplasty with high viscosity cement (HVC).&amp;lt;br \/&amp;gt;&amp;lt;strong&amp;gt;Methods&amp;lt;br \/&amp;gt;&amp;lt;\/strong&amp;gt; The patients with intensive pain caused by a fractured vertebrae were treated by application of HVC into the vertebral&amp;lt;br \/&amp;gt;body, through unilateral transpedicular approach. The application was performed in 422 patients (221 were treated for osteoporosis and 201 for malignancy) on 846 vertebrae.&amp;lt;br \/&amp;gt;&amp;lt;strong&amp;gt;Results&amp;lt;\/strong&amp;gt; &amp;lt;br \/&amp;gt;Preoperative Visual Analogue Scale (VAS) score was 8.35 and 2.21 (p&amp;amp;lt;0.00001) 24 hours after surgery and 3 months later,&amp;lt;br \/&amp;gt;respectively. There was no serious intra- and post-surgery complication. By diascopy during the surgery in 121 (14.3%) vertebrae cement leakage from the fractured vertebral body was evidenced, which did not cause any aggravation of patients&amp;amp;rsquo; clinical status.&amp;lt;br \/&amp;gt;&amp;lt;strong&amp;gt;Conclusion&amp;lt;br \/&amp;gt;&amp;lt;\/strong&amp;gt; Vertebroplasty with HVC is a method that successfully combines all advantages of this method but it also minimizes the risk of extra-ossal cement leakage which makes it significantly safer for the surgeon and for the patient as well.&amp;lt;\/p&amp;gt;<\/jats:p>","DOI":"10.17392\/842-16","type":"journal-article","created":{"date-parts":[[2024,4,15]],"date-time":"2024-04-15T12:51:43Z","timestamp":1713185503000},"page":"148-153","source":"Crossref","is-referenced-by-count":1,"title":["Application of high viscosity bone cement in vertebroplasty for treatment of painful vertebral body fracture"],"prefix":"10.17392","volume":"13","author":[{"given":"Sa\u0161a","family":"Rapan","sequence":"first","affiliation":[{"name":"University Hospital Centre Osijek","place":["Osijek,Croatia"],"department":["Department of Orthopedic Surgery"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karin","family":"Krni\u0107","sequence":"additional","affiliation":[{"name":"University Hospital Centre Osijek","place":["Osijek,Croatia"],"department":["Department of Orthopedic Surgery"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vjeran","family":"Rapan","sequence":"additional","affiliation":[{"name":"University Hospital Centre Osijek","place":["Osijek,Croatia"],"department":["Department of Orthopedic Surgery"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vjekoslav","family":"Kolarevi\u0107","sequence":"additional","affiliation":[{"name":"University Hospital Centre Osijek","place":["Osijek,Croatia"],"department":["Department of Orthopedic Surgery"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"49509","published-online":{"date-parts":[[2016,6,30]]},"reference":[{"key":"ref1","first-page":"413","article-title":"Osteoporotic compression vertebral fracture and vertebral augmentation","author":"LKimiL","year":"2008","unstructured":"Kimi L, Kondo D.O. Osteoporotic compression verte-\nbral fracture and vertebral augmentation. Semin Inter-\nvent Radiol 2008; 25:413-24.","journal-title":"Semin Intervent Radiol"},{"key":"ref2","first-page":"152","article-title":"Conservative management of patients with an osteoporotic vertebral fracture: a review of literature","author":"ULongoU","year":"2012","unstructured":"Longo UG, Loppini M, Denaro L, Maffulli N, Dena-\nro V. Conservative management of patients with an \nosteoporotic vertebral fracture: a review of literature. \nJ Bone Joint Surg 2012; 94:152-7.","journal-title":"J Bone Joint Surg"},{"key":"ref3","first-page":"262","article-title":"Treatment of painful compression vertebral fractures with vertebroplasty: results and complications","author":"GAnselmettiG","year":"2005","unstructured":"Anselmetti GC, Corgnier A, Debernadi F, Regge D. \nTreatment of painful compression vertebral fractures \nwith vertebroplasty: results and complications. Radi-\nol Med 2005; 110:262-72.","journal-title":"Radiol Med"},{"key":"ref4","first-page":"13","article-title":"Percutaneous vertebroplasty in patients with intractable pain from osteoporotic or metastatic fractures: A prospective study using quality-of-life assessment","author":"GCheungG","year":"2006","unstructured":"Cheung G, Chow E, Holden L, Vidmar M, Danjoux \nC, Yee AJ, Connoly R, Finklstein J. Percutaneous ver-\ntebroplasty in patients with intractable pain from oste-\noporotic or metastatic fractures: A prospective study \nusing quality-of-life assessment. Can Assoc Radiol J \n2006; 57:13-21.","journal-title":"Can Assoc Radiol J"},{"key":"ref5","first-page":"1549","article-title":"Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures: first short term results","author":"MVoormolenM","year":"2003","unstructured":"Voormolen MH, Lohle PN, Frnsen H, Juttmann JR, \nde Waal Malefijt J, Lampmann LE. Percutaneous ver-\ntebroplasty in the treatment of osteoporotic vertebral \ncompression fractures: first short term results. Ned \nTijdschr Geneeskd 2003; 147:1549-53.","journal-title":"Ned Tijdschr Geneeskd"},{"key":"ref6","first-page":"884","article-title":"Pescutaneous vertebroplasty for osteoporotic vertebral compression fracture: experiences and prospective clinical otcome in 26 consecutive patients with 50 vertebral fractures","author":"RFesslR","year":"2005","unstructured":"Fessl R, Roemer FW, Bohndorf K. Pescutaneous ver-\ntebroplasty for osteoporotic vertebral compression \nfracture: experiences and prospective clinical otcome \nin 26 consecutive patients with 50 vertebral fractures. \nRofo 2005; 177:884-92.","journal-title":"Rofo"},{"key":"ref7","first-page":"998","article-title":"Percutaneous vertebroplasty in the therapy of osteoporotic vertebral compression fractures: a critical review","author":"KHochmuthK","year":"2006","unstructured":"Hochmuth K, Proschek D, Schwarz W, Mack M, \nKurth AA, Vogl TJ. Percutaneous vertebroplasty in \nthe therapy of osteoporotic vertebral compression \nfractures: a critical review. Eur Radiol 2006; 16:998-\n1004.","journal-title":"Eur Radiol"},{"key":"ref8","first-page":"559","article-title":"Percutaneous vertebroplasty for osteoporotic fractures","author":"SAfzalS","year":"2007","unstructured":"Afzal S, Dhar S, Vasavada NB, Akbar S. Percuta-\nneous vertebroplasty for osteoporotic fractures. Pain \nPhysician 2007; 10:559-63.","journal-title":"Pain Physician"},{"key":"ref9","first-page":"583","article-title":"Comparing pain reduction following kyphoplasty and vertebroplasty for osteoporotic vertebral compression fractures","author":"JGillJ","year":"2007","unstructured":"Gill JB, Kuper M, Chin PC, Zhang Y, Schutt R Jr. \nComparing pain reduction following kyphoplasty and \nvertebroplasty for osteoporotic vertebral compression \nfractures. Pain Physician 2007; 10:583-90.","journal-title":"Pain Physician"},{"key":"ref10","first-page":"911","article-title":"Vertebroplasty for Vertebral compression fracture","author":"SRapanS","year":"2009","unstructured":"Rapan S, Jovanovic S, Gulan G. Vertebroplasty for \nVertebral compression fracture. Coll Antropoll 2009; \n33:911-4.","journal-title":"Coll Antropoll"},{"key":"ref11","first-page":"366","article-title":"Vertebral compression fractures: pain reduction and improvement in functional mobility after percutaneous PMMA vertebroplasty retrospective report of 245 cases","author":"EwansAjEwans","year":"2003","unstructured":"Ewans Aj, Jensen ME, Kip KE, De Nardo AJ, Lawler \nGj, Negin GA, Remley KB, Boutin SM, Dunnagan \nSA. Vertebral compression fractures: pain reduction \nand improvement in functional mobility after percuta-\nneous PMMA vertebroplasty retrospective report of \n245 cases. Radiology 2003; 226:366-72.","journal-title":"Radiology"},{"key":"ref12","first-page":"479","article-title":"Pain reduction in patients with painful vertebral compression fractures undergoing percutaneous vertebroplasty","author":"BPongsoipetchB","year":"2007","unstructured":"Pongsoipetch B. Pain reduction in patients with pa-\ninful vertebral compression fractures undergoing \npercutaneous vertebroplasty. J Med Assoc Thai 2007; \n90:479-84.","journal-title":"J Med Assoc Thai"},{"key":"ref13","first-page":"1835","article-title":"Vertebroplasty: What is important and what is not","author":"AliAliAli","year":"209","unstructured":"Ali Ali F, Barrow T, Luke K. Vertebroplasty: What is \nimportant and what is not. AJNR Am J Neuroradiol \n209; 30:1835-9.","journal-title":"AJNR Am J Neuroradiol"},{"key":"ref14","first-page":"250","article-title":"Pulmonary cement embolism after percutaneous vertebroplasty in osteoporotic vertebral compression fractures: incidence, characteristics, and risk factors","author":"YKimY","year":"2009","unstructured":"Kim YJ, Lee JW, Park KW, Yeom JS, Jeong HS, Park \nJM, Kang HS. Pulmonary cement embolism after \npercutaneous vertebroplasty in osteoporotic vertebral \ncompression fractures: incidence, characteristics, and \nrisk factors. Radiology 2009; 25:250-9.","journal-title":"Radiology"},{"key":"ref15","first-page":"1228","article-title":"Percutaneous treatment of vertebral compression fractures: a meta-analysis of complications","author":"MLeeM","year":"2009","unstructured":"Lee MJ, Dumonski M, Cahill P, Stanley T, Park D, \nSingh K. Percutaneous treatment of vertebral com-\npression fractures: a meta-analysis of complications. \nSpine 2009; 34:1228-32.","journal-title":"Spine"},{"key":"ref16","first-page":"817","article-title":"Retrieval of cement embolus from inferior vena cava after percutaneous vertebroplasty","author":"SAthreyaS","year":"2009","unstructured":"Athreya S, Mathias N, Rogers P, Edwards R. Retrie-\nval of cement embolus from inferior vena cava after \npercutaneous vertebroplasty. Cardiovasc Intervent \nRadiol 2009; 32:817-9.","journal-title":"Cardiovasc Intervent Radiol"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1007\/s00270-009-9509-7","article-title":"Temperature measurement during polymerization of bone cement in percutaneous vertebroplasty: an in vivo study in humans","author":"GAnselmettiG","year":"2009","unstructured":"Anselmetti GC, Manca A, Kanika K, Murphy K, \nEminefendic H, Masala S, Regge D. Temperature \nmeasurement during polymerization of bone cement \nin percutaneous vertebroplasty: an in vivo study in \nhumans. Cardiovasc Intervent Radiol 2009; 32:491-8.","journal-title":"Cardiovasc Intervent Radiol"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"1007","DOI":"10.1017\/S0033291700009934","article-title":"Clinical applications of visual analogue scales: a critical review","author":"HMccormackH","year":"1988","unstructured":"McCormack HM, Horne DJ, Sheather S. Clinical \napplications of visual analogue scales: a critical re-\nview. Psychol Med 1988; 18:1007-19.","journal-title":"Psychol Med"},{"key":"ref19","first-page":"394","article-title":"A comparision of two new tehnologies for percutaneous vertebral augmentation: confidence vertebroplasty vs sky kyphoplasty","author":"YFolmanY","year":"2011","unstructured":"Folman Y, Shabat S. A comparision of two new tehno-\nlogies for percutaneous vertebral augmentation: con-\nfidence vertebroplasty vs sky kyphoplasty. Isr Med \nAssoc J 2011; 13:394-7.","journal-title":"Isr Med Assoc J"},{"key":"ref20","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1148\/radiol.2381040841","article-title":"Percutaneous vertebroplasty for spinal matastases: complications","author":"HBarragan-CamposH","year":"2006","unstructured":"Barragan-Campos HM, Vallee Jn, Lo D, Cormier E, \nJean B, Rose M, Astagnean P, Chiras J. Percutaneous \nvertebroplasty for spinal matastases: complications. \nRadiology 2006; 238:354-62.","journal-title":"Radiology"},{"key":"ref21","first-page":"1933","article-title":"The effects of cement volume on clinical outcomes of percutaneous vertebroplasty","author":"TKaufmannT","year":"2006","unstructured":"Kaufmann TJ, Trout AT, Kallmes DF. The effects of \ncement volume on clinical outcomes of percutaneo-\nus vertebroplasty. AJNR Am J Neuroradiol 2006; \n27:1933-7.","journal-title":"AJNR Am J Neuroradiol"},{"key":"ref22","first-page":"2562","article-title":"High-viscosity cement significantly enhances uniformity of cement filling in vertebroplasty: an experimental model and study on cement leakage","author":"GBaroudG","year":"2006","unstructured":"Baroud G, Crookshank M, Bohner M. High-viscosity \ncement significantly enhances uniformity of cement \nfilling in vertebroplasty: an experimental model and \nstudy on cement leakage. Spine 2006; 31:2562-8.","journal-title":"Spine"},{"key":"ref23","first-page":"56","article-title":"Dose-dependent epidural leakage of PMMA after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures","author":"KRyuK","year":"2002","unstructured":"Ryu KS, Park CK, Kim MC, Kang JK. Dose-depen-\ndent epidural leakage of PMMA after percutaneous \nvertebroplasty in patients with osteoporotic vertebral \ncompression fractures. J Neurosurg 2002; 96:56-61.","journal-title":"J Neurosurg"},{"key":"ref24","first-page":"56","article-title":"Dose-dependent epidural leakage of polymethylmethacrylate after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures","author":"KRyuK","year":"2002","unstructured":"Ryu KS, Park CK, Kim MC, Kang JK. Dose-depen-\ndent epidural leakage of polymethylmethacrylate af-\nter percutaneous vertebroplasty in patients with oste-\noporotic vertebral compression fractures. J Neurosurg \n2002; 96:56-61.","journal-title":"J Neurosurg"},{"key":"ref25","first-page":"1272","article-title":"Clinical investigations of polymethylmethacrylate cement viscosity during vertebroplasty and related in vitro measurements","author":"ABogerA","year":"2009","unstructured":"Boger A, Wheeler KD, Schenk B, Heini PF. Clinical \ninvestigations of polymethylmethacrylate cement vis-\ncosity during vertebroplasty and related in vitro mea-\nsurements. Eur Spine J 2009; 18:1272-8.","journal-title":"Eur Spine J"},{"key":"ref26","first-page":"377","article-title":"Percutaneous vertebroplasty: a comparison between the procedure using the traditional and the new side-opening cannula for osteoporotic vertebral fracture","author":"NFiguerendoN","year":"2009","unstructured":"Figuerendo N, Barra F, Moraes L, Rotta R, Casula-\nri LA. Percutaneous vertebroplasty: a comparison \nbetween the procedure using the traditional and the \nnew side-opening cannula for osteoporotic vertebral \nfracture. Arq Neuropsiquiatr 2009; 67:377-81.","journal-title":"Arq Neuropsiquiatr"},{"key":"ref27","first-page":"175","article-title":"Vertebroplasty: cement leakage into the disc increase the risk of new fracture of adjacent vertebral body","author":"ELinE","year":"2004","unstructured":"Lin EP, Ekholm S, Hiwatashi A, Westesson PL. Ver-\ntebroplasty: cement leakage into the disc increase the \nrisk of new fracture of adjacent vertebral body. AJNR \nAm J Neuroradiol 2004; 25:175-80.","journal-title":"AJNR Am J Neuroradiol"},{"key":"ref28","doi-asserted-by":"crossref","first-page":"937","DOI":"10.1007\/s00270-008-9324-6","article-title":"Percutaneous vertebroplasty and bone cement leakage: clinical experience with a new high-viscosity bone cement and delivery system for vertebral augmentation in benign and malignant compression fractures","author":"GAnselmettiG","year":"2008","unstructured":"Anselmetti GC, Zoarski G, Manca A, Masala S, Emi-\nnefendic H, Russo F, Regge D. Percutaneous verte-\nbroplasty and bone cement leakage: clinical expe-\nrience with a new high-viscosity bone cement and \ndelivery system for vertebral augmentation in benign \nand malignant compression fractures. Cardiovasc In-\ntervent Radiol 2008; 31:937-47.","journal-title":"Cardiovasc Intervent Radiol"},{"key":"ref29","first-page":"783","article-title":"Analysis of the complication and prevention on treatment of osteoporotic vertebral compressive fractures by percutaneous vertebroplasty (PVP)","author":"HWangH","year":"2009","unstructured":"Wang HL, Jiang ZG, Wang ZG, Zhu J, Zhao HT. \nAnalysis of the complication and prevention on tre-\natment of osteoporotic vertebral compressive fractu-\nres by percutaneous vertebroplasty (PVP). Zhongguo \nGu Shang 2009; 22:783-4.","journal-title":"Zhongguo Gu Shang"},{"key":"ref30","first-page":"315","article-title":"Vertebroplasty: magnetic resonance findings related to cement leakage risk","author":"YKohY","year":"2007","unstructured":"Koh YH, Han D, Cha JH, Seong CK, Kim J, Choi \nYH. Vertebroplasty: magnetic resonance findings \nrelated to cement leakage risk. Acta Radiol 2007; \n48:315-20.","journal-title":"Acta Radiol"},{"key":"ref31","first-page":"90","article-title":"Surgical removal of epidural and intradural PMMA extravasation complicating percutaneous vertebroplasty for an osteoporotic lumbar compression fracture. Case report","author":"SShapiroS","year":"2003","unstructured":"Shapiro S, Abel T, Purvines S. Surgical removal of \nepidural and intradural PMMA extravasation com-\nplicating percutaneous vertebroplasty for an osteo-\nporotic lumbar compression fracture. Case report. J \nNeurosurg 2003; 98:90-2.","journal-title":"J Neurosurg"},{"key":"ref32","first-page":"326","article-title":"Surgical removal of extravasated epidural and neuroforaminal polymethylmetacrylate after percutaneous vertebroplasty in the thoracic spine","author":"CWuuC","year":"2007","unstructured":"Wuu CC, Lin MH, Yang SH, Chen PQ, Shih TT. Sur-\ngical removal of extravasated epidural and neurofora-\nminal polymethylmetacrylate after percutaneous ver-\ntebroplasty in the thoracic spine. Eur Spine J 2007; \n3:326-31.","journal-title":"Eur Spine J"},{"key":"ref33","first-page":"E379","article-title":"Intradural cement leakage: a devastatingly rare complication of vertebroplasty","author":"YChenY","year":"2006","unstructured":"Chen YJ, Tn TS, Chen WH, Chen CC, Lee TS. Intra-\ndural cement leakage: a devastatingly rare complica-\ntion of vertebroplasty. Spine 2006; 31:E379-82.","journal-title":"Spine"},{"key":"ref34","first-page":"457","article-title":"Polymethylmethacrylate cement dislodgment foolowing percutaneous vertebroplasty: a case report","author":"TTsaiT","year":"2003","unstructured":"Tsai TT, Chen WJ, Lai PL, Chen LH, Niu CC, Fu \nTS, Wong CB. Polymethylmethacrylate cement dis-\nlodgment foolowing percutaneous vertebroplasty: a \ncase report. Spine 2003; 28: E457-60.","journal-title":"Spine"},{"key":"ref35","first-page":"358","article-title":"Combined extraforaminal anf intradiscal cement leakage following percutaneous vertebroplasty","author":"JChenJ","year":"2007","unstructured":"Chen JK, Lee HM, Shih JT, Hung ST. Combi-\nned extraforaminal anf intradiscal cement leakage \nfollowing percutaneous vertebroplasty. Spine 2007; \n32: E358-62.","journal-title":"Spine"},{"key":"ref36","first-page":"419","article-title":"Paraplegia as a complication of percutaneous vertebroplasty with PMMA: a case report","author":"BLeB","year":"2002","unstructured":"Le BJ, Lee SR, Yoo TY. Paraplegia as a complication \nof percutaneous vertebroplasty with PMMA: a case \nreport. Spine 2002; 27:419-22.","journal-title":"Spine"},{"key":"ref37","first-page":"525","article-title":"Percutaneous vertebroplasty for osteolytic metastases and myeloma: effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up","author":"ACottenA","year":"1996","unstructured":"Cotten A, Dewatre F, Cortet B, Cotton A, Dewatre \nF,Quartet B. Percutaneous vertebroplasty for oste-\nolytic metastases and myeloma: effects of the per-\ncentage of lesion filling and the leakage of methyl \nmethacrylate at clinical follow-up. Radiology 1996; \n200:525-30.","journal-title":"Radiology"},{"key":"ref38","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1148\/radiol.2381040841","article-title":"Percutaneous vertebroplasty for spinal matastases: complications","author":"HBarragan-CamposH","year":"2006","unstructured":"Barragan-Campos HM, Vallee Jn, Lo D, Cormier E, \nJean B, Rose M, Astagnean P, Chiras J. Percutaneous \nvertebroplasty for spinal matastases: complications. \nRadiology 2006; 238:354-62.","journal-title":"Radiology"},{"key":"ref39","article-title":"Aplikacija visokoviskoznog ko\u0161tanog cementa u vertebroplastici u lije\u010denju bolnog prijeloma trupa kralje\u0161ka Sa\u0161a Rapan, Karin Krni\u0107, Vjeran Rapan","unstructured":"Aplikacija visokoviskoznog ko\u0161tanog cementa u vertebroplastici \nu lije\u010denju bolnog prijeloma trupa kralje\u0161ka \nSa\u0161a Rapan, Karin Krni\u0107, Vjeran Rapan, Vjekoslav Kolarevi\u0107 \nMedicinski fakultet Osijek, Osijek, Hrvatska \nSA\u017dETAK \nCilj Ocijeniti uspje\u0161nost i komplikacije vertebroplastike s visokoviskoznim cementom (HVC).","journal-title":"Vjekoslav Kolarevi\u0107 Medicinski fakultet Osijek"},{"key":"ref40","article-title":"Metode Pacijenti s jakom boli zbog prijeloma trupa kralje\u0161ka lije\u010deni su aplikacijom visokoviskoznog cementa (HVC) u trup kralje\u0161ka unilateralnim transpedikularnim pristupom. Cement je apliciran kod 422 pacijenta","unstructured":"Metode Pacijenti s jakom boli zbog prijeloma trupa kralje\u0161ka lije\u010deni su aplikacijom visokoviskoznog \ncementa (HVC) u trup kralje\u0161ka unilateralnim transpedikularnim pristupom. Cement je apliciran kod \n422 pacijenta, u 846 kralje\u017eaka."},{"key":"ref41","article-title":"24 sata, odnosno 3 mjeseca nakon operacije. Nije bilo ozbiljnijih intraoperacijskih i poslijeoperacijskih komplikacija. Dijaskopijom je, za vrijeme operacijskog zahvata, u 121 kralje\u0161ku (14,3%) uo\u010deno istjecanje cementa koje nije utjecalo na promjenu klini\u010dkog statusa pacijenta","author":"RezultatiPrijeoperacijskiRezultati","unstructured":"Rezultati Prijeoperacijski VAS (Visual Analogue Scale) iznosio je 8,35 i 2,21 (p<0,00001) 24 sata, \nodnosno 3 mjeseca nakon operacije. Nije bilo ozbiljnijih intraoperacijskih i poslijeoperacijskih kom-\nplikacija. Dijaskopijom je, za vrijeme operacijskog zahvata, u 121 kralje\u0161ku (14,3%) uo\u010deno istjecanje \ncementa koje nije utjecalo na promjenu klini\u010dkog statusa pacijenta. \nZaklju\u010dak Vertebroplastika s HVC-om je procedura koja u sebi uspje\u0161no ujedinjuje sve prednosti ove \nmetode do sada, ali i minimalizira mogu\u0107nost istjecanja cementa ekstraosalno, \u0161to ju \u010dini znatno sigur-\nnijom kako za operatera, tako i za pacijenta. \nKlju\u010dne rije\u010di: ko\u0161tani cement, vertebralno oja\u010danje, Visual Analogue Scale"}],"container-title":["Medicinski Glasnik"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/medicinskiglasnik.ba\/article\/283\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/medicinskiglasnik.ba\/article\/283\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T09:43:27Z","timestamp":1775468607000},"score":1,"resource":{"primary":{"URL":"https:\/\/medicinskiglasnik.ba\/article\/id\/29\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,6,30]]},"references-count":41,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2016,6,30]]},"published-print":{"date-parts":[[2016,6,30]]}},"URL":"https:\/\/doi.org\/10.17392\/842-16","archive":["Internet Archive"],"relation":{},"ISSN":["1840-0132","1840-0132"],"issn-type":[{"value":"1840-0132","type":"electronic"},{"value":"1840-0132","type":"print"}],"subject":[],"published":{"date-parts":[[2016,6,30]]}}}