{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T10:57:14Z","timestamp":1775473034265,"version":"3.50.1"},"reference-count":18,"publisher":"Medical Association of Zenica-Doboj","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medicinski Glasnik"],"published-print":{"date-parts":[[2018,8,24]]},"abstract":"<jats:p>&amp;lt;p&amp;gt;&amp;lt;strong&amp;gt;Aim &amp;lt;br \/&amp;gt;&amp;lt;\/strong&amp;gt;To calculate stress and deformation under the force of pressure and bending in the dynamic compression plate (DCP), locking compression plate (LCP), selfdynamisable internal fixator (SIF) and locked intramedullary nail (LIN) in the models of juvidur, beef tibia bone (cadaver) and software of bone model simulator. &amp;lt;br \/&amp;gt;&amp;lt;strong&amp;gt;Methods&amp;lt;br \/&amp;gt;&amp;lt;\/strong&amp;gt; Juvidur and bone models were used for the experimental study, static tests were performed with SHIMADZU AGS-X tester. CATIA software was used to create a 3D model for the SCA simulator, while software ANSYS to calculate the tension and deformation for compressive and bending forces. Stress and deformation analysis was performed with the use of Finite Element Analysis (FEA). &amp;lt;br \/&amp;gt;&amp;lt;strong&amp;gt;Results&amp;lt;br \/&amp;gt;&amp;lt;\/strong&amp;gt; Weight coefficients of research methods were different (juvidur=0.3; cadaver=0.5; SCA Simuator=0.2), and weight coefficients of the force of pressure K p =0.5 and bending forces in one plane K 1 =0.25 and K 2 =0.25 in another plane, the overall result on the dilatation of DCP, LCP, LIN and SIF on juvidur and veal cadaver models showed that the first ranking was the LIN with a rank coefficient K U-LIN = 0.0603, followed by the IFM with K U-IFM = 0.0621, DCP with K U-DCP = 0.0826 and LCP with K U-LCP = 0.2264. &amp;lt;br \/&amp;gt;&amp;lt;strong&amp;gt;Conclusion&amp;lt;br \/&amp;gt;&amp;lt;\/strong&amp;gt; Dilatation size did not exceed 0.2264 mm, hence the implants fulfilled biomechanical conditions for the internal stabilization of bone fractures. Prevalence goes to the locked intramedullar nailing and Mitkovi\u0107 internal fixator in the treatment of diaphyseal, transversal, comminuted fractures in relation to DCP and LCP.&amp;lt;\/p&amp;gt;<\/jats:p>","DOI":"10.17392\/985-19","type":"journal-article","created":{"date-parts":[[2024,4,21]],"date-time":"2024-04-21T10:20:46Z","timestamp":1713694846000},"page":"88-92","source":"Crossref","is-referenced-by-count":2,"title":["Comparison of biomechanical stability of osteosynthesis materials in long bone fractures"],"prefix":"10.17392","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6826-1790","authenticated-orcid":false,"given":"Predrag","family":"Grubor","sequence":"first","affiliation":[{"name":"School of Medicine, University of Banja Luka","place":["Banja Luka,Bosnia and Herzegovina"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Milorad","family":"Mitkovi\u0107","sequence":"additional","affiliation":[{"name":"School of Medicine, University of Ni\u0161","place":["Ni\u0161,Serbia"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Milan","family":"Mitkovi\u0107","sequence":"additional","affiliation":[{"name":"School of Medicine, University of Ni\u0161","place":["Ni\u0161,Serbia"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Milan","family":"Grubor","sequence":"additional","affiliation":[{"name":"School of Medicine, University of Banja Luka","place":["Banja Luka,Bosnia and Herzegovina"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"49509","published-online":{"date-parts":[[2018,8,24]]},"reference":[{"key":"ref1","first-page":"1015","article-title":"Epidemiology of extremity in multiple trauma patients","author":"MBanerjeeM","year":"2013","unstructured":"Banerjee M, Bouillon B, Shafizadeh S, Paffrath T, \nLefering R. Epidemiology of extremity in \nmultiple trauma patients. Injury 2013; 44:1015-21.","journal-title":"Injury"},{"key":"ref2","first-page":"1243","article-title":"Predictors of late clinical outcome following orthopedic injuries after multiple trauma","author":"HPapeH","year":"2010","unstructured":"Pape HC, Probst C, Lohse R, Zelle BA, Panzica M, \nStalp M, Steel JL, Duhme HM, Pfeifer R, Krettek \nC, Sittaro NA. Predictors of late clinical outcome \nfollowing orthopedic injuries after multiple trauma. \nJ Trauma 2010; 69:1243-51.","journal-title":"J Trauma"},{"key":"ref3","first-page":"1160","article-title":"Standardized outcome evaluation after blunt multiple injuries by scoring systems: a clinical follow-up investigation 2 years after injury","author":"MStalpM","year":"2002","unstructured":"Stalp M, Koch C, Ruchholtz S, Regel G, Panzica M, \nKrettek C, Pape HC. Standardized outcome evaluati-\non after blunt multiple injuries by scoring systems: a \nclinical follow-up investigation 2 years after injury. \nJ Trauma 2002; 52:1160-68.","journal-title":"J Trauma"},{"key":"ref4","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/S0020-1383(13)70178-5","article-title":"Damage control orthopaedics in severe polytrauma with femur fracture","author":"PCaba-DoussouxP","year":"2012","unstructured":"Caba-Doussoux P, Leon-Baltasar JL, Garcia-Fuen-\ntes C, Resines-Erasun C. Damage control orthopae-\ndics in severe polytrauma with femur fracture. Injury \n2012; 43:42-6.","journal-title":"Injury"},{"key":"ref5","first-page":"220","article-title":"In vitro biomechanical comparison of limited contact dynamic compression plate and locking compression plate","author":"AAguilaA","year":"2005","unstructured":"Aguila AZ, Manos JM, Orlansky AS, Todhunter \nRJ, Trotter EJ, Van der Meulen MC. In vitro bio-\nmechanical comparison of limited contact dynamic \ncompression plate and locking compression plate. \nVet Comp Orthop Traumatol 2005; 18:220-6.","journal-title":"Vet Comp Orthop Traumatol"},{"key":"ref6","first-page":"261","article-title":"Biomechanical stability of juvidur and bone models on osteosynthesic materials","author":"PGruborP","year":"2016","unstructured":"Grubor P, Mitkovi\u0107 MI, Grubor M, Mitkovi\u0107 ML, \nMeccariello L, Falzarano G. Biomechanical stability \nof juvidur and bone models on osteosynthesic mate-\nrials. Acta Inform Med 2016; 24:261-5.","journal-title":"Acta Inform Med"},{"key":"ref7","first-page":"41","article-title":"Examination of stability of osteosynthetic material by software bone stimulator","author":"PGruborP","year":"2016","unstructured":"Grubor P, Tanjga R, Grubor M, \u0110eri J. Examination \nof stability of osteosynthetic material by software \nbone stimulator. Scr Med 2016; 47:41-6.","journal-title":"Scr Med"},{"key":"ref8","first-page":"231","article-title":"Assessment of stiffness and strength of 4 different implants available for equine fracture treatment: a study on a 20 degrees oblique long-bone fracture model using a bone substitute","author":"MFlorinM","year":"2005","unstructured":"Florin M, Arzdorf M, Linke B, Auer JA. Assessment \nof stiffness and strength of 4 different implants ava-\nilable for equine fracture treatment: a study on a 20 \ndegrees oblique long-bone fracture model using a \nbone substitute. Vet Surg 2005; 34:231-8.","journal-title":"Vet Surg"},{"key":"ref9","first-page":"8590251","article-title":"Biomechanical property of a newly designed assembly locking compression plate: three-dimensional finite element analysis","author":"Jiang-JunZhouJiang-Jun","year":"2017. 2017","unstructured":"Jiang-Jun Zhou, Min Zhao, Da Liu, Hai-Ying \nLiu, and Cheng-Fei Du. Biomechanical property \nof a newly designed assembly locking compression \nplate: three-dimensional finite element analysis. J \nHealthc Eng 2017; 2017: 8590251.","journal-title":"J Healthc Eng"},{"issue":"3","key":"ref10","first-page":"14","article-title":"Effect of plate position relative to bending direction on the rigidity of a plate osteosynthesis. A theoretical analysis","author":"EGautierE","year":"2000","unstructured":"Gautier E, Perren SM, Cordey J. Effect of plate po-\nsition relative to bending direction on the rigidity of \na plate osteosynthesis. A theoretical analysis. Injury \n2000; 31(suppl 3):C14-20.","journal-title":"Injury"},{"key":"ref11","first-page":"603","article-title":"Impact of double-tiered subchondral support procedure with a polyaxial locking plate on the stability of distal radius fractures using fresh cadaveric forearms. Biomechanical and radiographic analyses","author":"STsutsuiS","year":"2016","unstructured":"Tsutsui S, Kawasaki K, Yamakoshi K, Uchiya-\nma E, Aoki M, Inagaki K. Impact of double-tiered \nsubchondral support procedure with a polyaxial loc-\nking plate on the stability of distal radius fractures \nusing fresh cadaveric forearms. Biomechanical and \nradiographic analyses. J Orthop Sci 2016;21:603-8.","journal-title":"J Orthop Sci"},{"issue":"2","key":"ref12","first-page":"63","article-title":"An osteosynthesis plate based on the Dynamic Compression Plate and the Point Contact Fixator (PC-Fix)","author":"RFriggR","year":"2001","unstructured":"Frigg R . Locking Compression Plate (LCP). An \nosteosynthesis plate based on the Dynamic Compre-\nssion Plate and the Point Contact Fixator (PC-Fix). \nInjury 2001; 32 (suppl 2):63-6.","journal-title":"Injury"},{"key":"ref13","first-page":"819","article-title":"Auxetic polymeric bone plate as internal fixator for long bone fractures: Design, fabrication and structural analysis","author":"SMehmoodS","year":"2015","unstructured":"Mehmood S, Ali MN, Ansari U, Mir M, Khan MA. \nAuxetic polymeric bone plate as internal fixator for \nlong bone fractures: Design, fabrication and structu-\nral analysis. Technol Health Care 2015; 23:819-33.","journal-title":"Technol Health Care"},{"key":"ref14","first-page":"311","article-title":"Intramedullary nailing of the distal tibia. Does angular stable locking make a difference?","author":"PAugatP","year":"2015","unstructured":"Augat P, B\u00fchren V. Intramedullary nailing of the dis-\ntal tibia. Does angular stable locking make a diffe-\nrence?. Unfallchirurg 2015; 118:311-7.","journal-title":"Unfallchirurg"},{"key":"ref15","first-page":"488","article-title":"Biomechanics of locked plates and screws","author":"KEgolK","year":"2004","unstructured":"Egol KA, Kubiak EN, Fulkerson E, Kummer FJ, Ko-\nval KJ. Biomechanics of locked plates and screws. J \nOrthop Trauma 2004; 18:488-93.","journal-title":"J Orthop Trauma"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1186\/1746-6148-8-139","article-title":"In-vitro comparison of LC-DCP-and LCP-constructs in the femur of newborn calves -a pilot study","author":"MHoerdemannM","year":"2012","unstructured":"Hoerdemann M, G\u00e9det P, Ferguson SJ, Sauter-Louis \nC, Nuss K. In-vitro comparison of LC-DCP-and \nLCP-constructs in the femur of newborn calves -a \npilot study. BMC Vet Res 2012; 8: 139","journal-title":"BMC Vet Res"},{"key":"ref17","first-page":"1490","article-title":"Use of a novel intramedullary nail for femoral fracture repair in calves: 25 cases","author":"JBellonJ","year":"2008-2009. 2011","unstructured":"Bellon J, Mulon PY. Use of a novel intramedu-\nllary nail for femoral fracture repair in calves: 25 \ncases (2008-2009). J Am Vet Med Assoc 2011; \n238:1490-6.","journal-title":"J Am Vet Med Assoc"},{"key":"ref18","first-page":"663","article-title":"Mechanical comparison of 3.5 mm broad dynamic compression plate, broad limitedcontact dynamic compression plate, and narrow locking compression plate systems using interfragmentary gap models","author":"JUhlJ","year":"2008","unstructured":"Uhl JM, Seguin B, Kapatkin AS, Schulz KS, Garcia \nTC, Stover SM. Mechanical comparison of 3.5 mm \nbroad dynamic compression plate, broad limited-\ncontact dynamic compression plate, and narrow loc-\nking compression plate systems using interfragmen-\ntary gap models. Vet Surg 2008; 37:663-73.","journal-title":"Vet Surg"}],"container-title":["Medicinski Glasnik"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/medicinskiglasnik.ba\/article\/196\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/medicinskiglasnik.ba\/article\/196\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T09:43:57Z","timestamp":1775468637000},"score":1,"resource":{"primary":{"URL":"https:\/\/medicinskiglasnik.ba\/article\/id\/166\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,8,24]]},"references-count":18,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2018,8,24]]},"published-print":{"date-parts":[[2018,8,24]]}},"URL":"https:\/\/doi.org\/10.17392\/985-19","archive":["Internet Archive"],"relation":{"is-cited-by":[{"id-type":"doi","id":"10.1007\/978-3-030-98279-9_9","asserted-by":"object"}]},"ISSN":["1840-0132","1840-0132"],"issn-type":[{"value":"1840-0132","type":"electronic"},{"value":"1840-0132","type":"print"}],"subject":[],"published":{"date-parts":[[2018,8,24]]}}}