{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T17:32:11Z","timestamp":1793640731219,"version":"4.5.1"},"reference-count":19,"publisher":null,"issue":"1","license":[{"start":{"date-parts":[[2021,2,11]],"date-time":"2021-02-11T00:00:00Z","timestamp":1613001600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/lib.ossn.ru\/jour\/about\/editorialPolicies#openAccessPolicy"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Kardiologiia"],"abstract":"<jats:p>\n                    <jats:italic>Aim\u00a0\u00a0\u00a0\u00a0\u00a0<\/jats:italic>\n                    To evaluate the effect of cryo-exposure duration and the use of the Achieve circular mapping catheter on efficacy of cryoballoon ablation (CBA).\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:italic>Material and methods\u00a0<\/jats:italic>\n                    CBA of pulmonary vein ostia (PVO) is a major method for heart rhythm control in patients with atrial fibrillation (AF). Since the inception, the PVO CBA method has evolved; the recommended application time was changed, and the Achieve circular catheter appeared. We performed a retrospective analysis of PVO CBA administered to patients with AF in the I.V. Davydovsky Municipal Clinical Hospital from 2017 through 2019. The study included 100 patients with available clinical and demographic characteristics and remote results of the intervention. Three patient groups were analyzed based on differences in surgical techniques: group 1, Guidewire\u200a\/\u200a240 (n=31) with the cryoballoon placing on a guidewire and PVO exposure duration of 240 s; group 2, Guidewire\u200a\/\u200a180 (n=26) with the cryoballoon placing on a guidewire and PVO exposure duration of 180\u2008s; and group 3, Achieve\u200a\/\u200a180 (n=43) with the cryoballoon placing on the mapping catheter Achieve and PVO exposure duration of 180\u2008\u0441. The follow-up period was 33.2\u00b14.5, 15.2\u00b16.1, and 12.2\u00b14.1 months in the Guidewire\u200a\/\u200a240, Guidewire\u200a\/\u200a180, and Achieve\u200a\/\u200a180 groups, respectively. The intervention was considered effective when there was no relapse at the time of interview. A relapse of AF was determined as one or more paroxysms recorded on electrocardiogram (ECG) or during 24-h ECG monitoring; the \u201cblind period\u201d (first 3 months after the procedure) was excluded from the follow-up. Safety evaluation included clinically significant complications, such as phrenic nerve damage, hemopericardium, gastroparesis, hemoptysis, acute cerebrovascular disease, and formation of atrio-esophageal fistula. Effects of independent factors were determined with binary logistic regression.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:italic>Results<\/jats:italic>\n                    In the Guidewire\u200a\/\u200a240 group, efficacy of PVO CBA for the maximum follow-up period was 74.4%, which was significantly different from the value for the Guidewire\u200a\/\u200a180 group (57.7\u200a%, \u0440=0.015). At the same time, the difference between the Guidewire\u200a\/\u200a240 and Achieve\u200a\/\u200a180 groups was statistically non-significant for a comparable follow-up period (\u0440=0.144). Clinically significant complications were absent in all 3 groups. The independent factors that significantly increased the PVO CBA efficacy were the cryo-exposure duration of 240\u2009s compared to 180\u2009s (\u0440= 0.018) and the use of the Achieve catheter (\u0440=0.014).\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:italic>Conclusion\u00a0\u00a0\u00a0\u00a0\u00a0<\/jats:italic>\n                    Decreasing the cryo-exposure duration to less than 240 s is impractical (in absence of Achieve mapping catheter) since it impairs the long-term efficacy of PVO CBA and does not influence the risk of complications.\n                  <\/jats:p>\n                  <jats:p>\u00a0<\/jats:p>","DOI":"10.18087\/cardio.2021.1.n1365","type":"journal-article","created":{"date-parts":[[2021,3,12]],"date-time":"2021-03-12T04:21:35Z","timestamp":1615522895000},"page":"28-35","source":"Crossref","is-referenced-by-count":0,"title":["Duration of Applications Affects the Long-Term Efficacy of Cryoballoon Ablation Pulmonary Veins"],"prefix":"10.68900","volume":"61","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4094-7771","authenticated-orcid":true,"given":"F. H.","family":"Rzaev","sequence":"first","affiliation":[{"name":"Clinical City Hospital named after I.V. Davydovsky, Moscow Department of Healthcare, Moscow"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7378-2686","authenticated-orcid":true,"given":"Iu. I.","family":"Rachkova","sequence":"additional","affiliation":[{"name":"Clinical City Hospital named after I.V. Davydovsky, Moscow Department of Healthcare, Moscow"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6833-8938","authenticated-orcid":true,"given":"O. A.","family":"Nikolaeva","sequence":"additional","affiliation":[{"name":"Clinical City Hospital named after I.V. Davydovsky, Moscow Department of Healthcare, Moscow"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1300-4986","authenticated-orcid":true,"given":"M. V.","family":"Gorev","sequence":"additional","affiliation":[{"name":"Clinical City Hospital named after I.V. Davydovsky, Moscow Department of Healthcare, Moscow"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9921-1323","authenticated-orcid":true,"given":"Sh. G.","family":"Nardaia","sequence":"additional","affiliation":[{"name":"Clinical City Hospital named after I.V. Davydovsky, Moscow Department of Healthcare, Moscow"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4180-0445","authenticated-orcid":true,"given":"O. V.","family":"Makarycheva","sequence":"additional","affiliation":[{"name":"Moscow State University of Medicine and Dentistry named after A.I. Evdokimov, Moscow"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6310-7636","authenticated-orcid":true,"given":"E. Yu.","family":"Vasilieva","sequence":"additional","affiliation":[{"name":"Moscow State University of Medicine and Dentistry named after A.I. Evdokimov, Moscow"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6190-6808","authenticated-orcid":true,"given":"A. V.","family":"Shpektor","sequence":"additional","affiliation":[{"name":"Moscow State University of Medicine and Dentistry named after A.I. Evdokimov, Moscow"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":null,"published-online":{"date-parts":[[2021,2,11]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","unstructured":"Hindricks G, Potpara T, Dagres N, Arbelo E, Bax JJ, Blomstr\u00f6m-Lundqvist C et al. 2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association of Cardio-Thoracic Surgery (EACTS). European Heart Journal. 2020;ehaa612. [Epub ahead of print]. DOI: 10.1093\/eurheartj\/ehaa612","DOI":"10.1093\/eurheartj\/ehaa612"},{"key":"ref2","doi-asserted-by":"crossref","unstructured":"Kuck K-H, Brugada J, F\u00fcrnkranz A, Metzner A, Ouyang F, Chun KRJ et al. Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation. New England Journal of Medicine. 2016;374(23):2235\u2013 45. DOI: 10.1056\/NEJMoa1602014","DOI":"10.1056\/NEJMoa1602014"},{"key":"ref3","doi-asserted-by":"crossref","unstructured":"Tomaiko E, Tseng A, Su WW. Radiofrequency versus cryoballoon ablation for atrial fibrillation: an argument for a \u2018cryo-first\u2019 approach. Current Opinion in Cardiology. 2020;35(1):13\u20139. DOI: 10.1097\/HCO.0000000000000700","DOI":"10.1097\/HCO.0000000000000700"},{"key":"ref4","doi-asserted-by":"crossref","unstructured":"Ding J, Xu J, Ma W, Chen B, Yang P, Qi Y et al. A novel individualized strategy for cryoballoon catheter ablation in patients with paroxysmal atrial fibrillation. BMC cardiovascular disorders. 2019;19(1):299. DOI: 10.1186\/s12872-019-01295-1","DOI":"10.1186\/s12872-019-01295-1"},{"key":"ref5","doi-asserted-by":"crossref","unstructured":"Chen S, Schmidt B, Bordignon S, Perrotta L, Bologna F, Chun KRJ. Impact of Cryoballoon Freeze Duration on Long-Term Durability of Pulmonary Vein Isolation: ICE Re-Map study. JACC: Clinical Electrophysiology. 2019;5(5):551\u20139. DOI: 10.1016\/j.jacep.2019.03.012","DOI":"10.1016\/j.jacep.2019.03.012"},{"key":"ref6","doi-asserted-by":"crossref","unstructured":"Aryana A, Kenigsberg DN, Kowalski M, Koo CH, Lim HW, O\u2019Neill PG et al. Verification of a novel atrial fibrillation cryoablation dosing algorithm guided by time-to-pulmonary vein isolation: Results from the Cryo-DOSING Study (Cryoballoon-ablation DOSING Based on the Assessment of Time-to-Effect and Pulmonary Vein Isolation Guidance). Heart Rhythm. 2017;14(9):1319\u201325. DOI: 10.1016\/j.hrthm.2017.06.020","DOI":"10.1016\/j.hrthm.2017.06.020"},{"key":"ref7","doi-asserted-by":"crossref","unstructured":"Chen S, Schmidt B, Bordignon S, Tohoku S, Urbanek L, Plank K et al. Cryoballoon pulmonary vein isolation in treating atrial fibrillation using different freeze protocols: The \u201cICE\u2010T 4 minutes vs 3 minutes\u201d propensity\u2010matched study (Frankfurt ICE\u2010T 4 vs. 3). Journal of Cardiovascular Electrophysiology. 2020;31(8):1923\u201331. DOI: 10.1111\/jce.14602","DOI":"10.1111\/jce.14602"},{"key":"ref8","doi-asserted-by":"crossref","unstructured":"Boveda S, Providencia R, Albenque J-P, Combes N, Combes S, Hireche H et al. Real-time assessment of pulmonary vein disconnection during cryoablation of atrial fibrillation: can it be \u2018achieved\u2019 in almost all cases? Europace. 2014;16(6):826\u201333. DOI: 10.1093\/europace\/eut366","DOI":"10.1093\/europace\/eut366"},{"key":"ref9","unstructured":"Ayvazian S.A., Artukhina E.A., Gorev M.V., Davtian K.V., Ivanitskiy E.A., Korolev S.V. et al. Practical guidelines for procedure cryoballoon pulmonary vein isolation. Moscow. 2020. 112p. Av. at: https:\/\/club-aritmolog.ru\/assets\/files\/krioballonnoj-izolyacii-legochnyxven.pdf.2020"},{"key":"ref10","doi-asserted-by":"crossref","unstructured":"M\u00f6rtsell D, Malmborg H, L\u00f6nnerholm S, Jansson V, Blomstr\u00f6m-Lundqvist C. Acute and long-term efficacy and safety with a single cryoballoon application as compared with the standard dual application strategy: a prospective randomized study using the second-generation cryoballoon for pulmonary vein isolation in patients with symptomatic atrial fibrillation. EP Europace. 2018;20(10):1598\u2013605. DOI: 10.1093\/europace\/euy014","DOI":"10.1093\/europace\/euy014"},{"key":"ref11","doi-asserted-by":"crossref","unstructured":"Miyazaki S, Tada H. Complications of Cryoballoon Pulmonary Vein Isolation. Arrhythmia & Electrophysiology Review. 2019;8(1):60\u20134. DOI: 10.15420\/aer.2018.72.2","DOI":"10.15420\/aer.2018.72.2"},{"key":"ref12","doi-asserted-by":"crossref","unstructured":"Zou H, Zhang Y, Tong J, Liu Z. Multidetector computed tomography for detecting left atrial\/left atrial appendage thrombus: a meta-analysis. Internal Medicine Journal. 2015;45(10):1044\u201353. DOI: 10.1111\/imj.12862","DOI":"10.1111\/imj.12862"},{"key":"ref13","unstructured":"Sulimov V.A., Golitsin S.P., Panchenko E.P., Popov S.V., Revishvili A.Sh., Shubik Yu.V. et al. Diagnosis and treatment of atrial fibrillation. Recommendations of RSC, RSSA and ACVS. Russian Journal of Cardiology. 2013;18(4 S3):1\u2013100."},{"key":"ref14","doi-asserted-by":"crossref","unstructured":"Rottner L, Fink T, Heeger C-H, Schl\u00fcter M, Goldmann B, Lemes C et al. Is less more? Impact of different ablation protocols on periprocedural complications in second-generation cryoballoon based pulmonary vein isolation. EP Europace. 2018;20(9):1459\u201367. DOI: 10.1093\/europace\/eux219","DOI":"10.1093\/europace\/eux219"},{"key":"ref15","doi-asserted-by":"crossref","unstructured":"Padeletti L, Curnis A, Tondo C, Lunati M, Porcellini S, Verlato R et al. Pulmonary Vein Isolation with the Cryoballoon Technique: Feasibility, Procedural Outcomes, and Adoption in the Real World: Data from One Shot Technologies TO Pulmonary Vein Isolation (1STOP) Project. Pacing and Clinical Electrophysiology. 2017;40(1):46\u201356. DOI: 10.1111\/pace.12975","DOI":"10.1111\/pace.12975"},{"key":"ref16","doi-asserted-by":"crossref","unstructured":"Ciconte G, de Asmundis C, Sieira J, Conte G, Di Giovanni G, Mugnai G et al. Single 3-minute freeze for second-generation cryoballoon ablation: One-year follow-up after pulmonary vein isolation. Heart Rhythm. 2015;12(4):673\u201380. DOI: 10.1016\/j.hrthm.2014.12.026","DOI":"10.1016\/j.hrthm.2014.12.026"},{"key":"ref17","doi-asserted-by":"crossref","unstructured":"Ahmed H, Neuzil P, d\u2019Avila A, Cha Y-M, Laragy M, Mares K et al. The esophageal effects of cryoenergy during cryoablation for atrial fibrillation. Heart Rhythm. 2009;6(7):962\u20139. DOI: 10.1016\/j.hrthm.2009.03.051","DOI":"10.1016\/j.hrthm.2009.03.051"},{"key":"ref18","doi-asserted-by":"crossref","unstructured":"Metzner A, Burchard A, Wohlmuth P, Rausch P, Bardyszewski A, Gienapp C et al. Increased Incidence of Esophageal Thermal Lesions Using the Second-Generation 28-mm Cryoballoon. Circulation: Arrhythmia and Electrophysiology. 2013;6(4):769\u201375. DOI: 10.1161\/CIRCEP.113.000228","DOI":"10.1161\/CIRCEP.113.000228"},{"key":"ref19","doi-asserted-by":"crossref","unstructured":"F\u00fcrnkranz A, Bordignon S, B\u00f6hmig M, Konstantinou A, Dugo D, Perrotta L et al. Reduced incidence of esophageal lesions by luminal esophageal temperature\u2013guided second-generation cryoballoon ablation. Heart Rhythm. 2015;12(2):268\u201374. DOI: 10.1016\/j.hrthm.2014.10.033","DOI":"10.1016\/j.hrthm.2014.10.033"}],"container-title":["Kardiologiia"],"original-title":[],"link":[{"URL":"https:\/\/lib.ossn.ru\/jour\/article\/viewFile\/1365\/899","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T17:17:48Z","timestamp":1793639868000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardio.elpub.ru\/jour\/article\/view\/1365"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,11]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,2,11]]}},"URL":"https:\/\/doi.org\/10.18087\/cardio.2021.1.n1365","relation":{},"ISSN":["2412-5660","0022-9040"],"issn-type":[{"value":"2412-5660","type":"electronic"},{"value":"0022-9040","type":"print"}],"subject":[],"published":{"date-parts":[[2021,2,11]]}}}