{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T17:31:18Z","timestamp":1793640678582,"version":"4.5.1"},"reference-count":31,"publisher":null,"issue":"11","license":[{"start":{"date-parts":[[2025,12,28]],"date-time":"2025-12-28T00:00:00Z","timestamp":1766880000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/cardio.elpub.ru\/jour\/about\/editorialPolicies#openAccessPolicy"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Kardiologiia"],"abstract":"<jats:p>\n                    <jats:italic>Background \u00a0<\/jats:italic>\n                    \u00a0Cardioembolism in stroke and transient ischemic attack (TIA) patients is highly influenced by atrial fibrillation (AF). The best timing, duration, location (outpatient or inpatient), and procedure for diagnosing paroxysmal atrial fibrillation (PAF) after stroke\u200a\/\u200aTIA are unknown. We investigated the use of smart devices in the detection of PAF during the index event hospitalization.\n                    <jats:italic>Material and methods \u00a0<\/jats:italic>\n                    \u00a0Stroke and TIA patients hospitalized in the neurology service were evaluated. Patients with AF detected on the ECG at emergency department admission and patients with known AF were excluded from the study. Smartphone-based apps were given to 342 other patients to utilize the mobile app on smart devices during follow-up. Three cardiologists reviewed all smart device rhythm electrographs and identified patients with AF. On the basis of concurrent 24\u201372\u2008h Holter rhythm monitoring, the patients were separated into those who had PAF (n=85; group 1) and those who did not have PAF (n=245; group 2).\n                    <jats:italic>Results<\/jats:italic>\n                    \u00a0 \u00a0Left atrium size (LA), arterial hypertension, lowest and highest heart rate on the smart device and episodes of AF on the smart device differed between patients with and without PAFas noted on the 24\u201372\u2008h Holter rhythm recordings. Detection of AF on the smart device was found to be an independent predictor of PAF as observed on the Holter rhythm recording (p=0.017). An AF episode identified on the smart device predicted the detection of PAF on the Holter 24\u201372\u2008h rhythm recording with 58\u200a% sensitivity and 87\u200a% specificity. (AUC=0.723, 95\u200a% CI=0.569\u20130.876, p=0.007)\n                    <jats:italic>Conclusion<\/jats:italic>\n                    \u00a0 \u00a0The detection of PAF following acute ischemic stroke or TIA may be significantly improved during hospitalization by continuously monitoring cardiac rhythm with smart devices.\n                  <\/jats:p>","DOI":"10.18087\/cardio.2025.11.n2946","type":"journal-article","created":{"date-parts":[[2025,12,28]],"date-time":"2025-12-28T16:55:48Z","timestamp":1766940948000},"page":"94-100","source":"Crossref","is-referenced-by-count":0,"title":["Screening for Paroxysmal Atrial Fibrillation with Smart Devices in Hospitalized Patients with Stroke or Transient Ischemic Event"],"prefix":"10.68900","volume":"65","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4711-8538","authenticated-orcid":true,"given":"Ahmet An\u0131l","family":"Ba\u015fkurt","sequence":"first","affiliation":[{"name":"Department of Cardiology, Bak\u0131r\u00e7ay University \u00c7i\u011fli Training and Research Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8494-2980","authenticated-orcid":true,"given":"Ferhat Siyamend","family":"Yurdam","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Bak\u0131r\u00e7ay University \u00c7i\u011fli Training and Research Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-5253-2338","authenticated-orcid":true,"given":"Sevinj","family":"Namazova","sequence":"additional","affiliation":[{"name":"Department of Neurology, Bak\u0131r\u00e7ay University \u00c7i\u011fli Training and Research Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7168-9157","authenticated-orcid":true,"given":"Eren Ozan","family":"Bak\u0131r","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Bak\u0131r\u00e7ay University \u00c7i\u011fli Training and Research Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9167-493X","authenticated-orcid":true,"given":"Yusuf","family":"Demir","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Bak\u0131r\u00e7ay University \u00c7i\u011fli Training and Research Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-6532-5208","authenticated-orcid":true,"given":"Ay\u015fe Ceren","family":"\u00d6zt\u00fcrk","sequence":"additional","affiliation":[{"name":"Department of Neurology, Bak\u0131r\u00e7ay University \u00c7i\u011fli Training and Research Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-6304-2944","authenticated-orcid":true,"given":"Yeliz","family":"\u00c7ift\u00e7i","sequence":"additional","affiliation":[{"name":"Department of Neurology, Bak\u0131r\u00e7ay University \u00c7i\u011fli Training and Research Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3847-7598","authenticated-orcid":true,"given":"Oktay","family":"\u015een\u00f6z","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Bak\u0131r\u00e7ay University \u00c7i\u011fli Training and Research Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":null,"published-online":{"date-parts":[[2025,12,28]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","unstructured":"Khoo CW, Lip GY. Clinical outcomes of acute stroke patients with atrial fibrillation. Expert Review of Cardiovascular Therapy. 2009;7(4):371\u20134. DOI: 10.1586\/erc.09.11","DOI":"10.1586\/erc.09.11"},{"key":"ref2","doi-asserted-by":"crossref","unstructured":"Healey JS, Connolly SJ, Gold MR, Israel CW, Van Gelder IC, Capucci A et al. Subclinical atrial fibrillation and the risk of stroke. The New England Journal of Medicine. 2012;366(2):120\u20139. DOI: 10.1056\/NEJMoa1105575","DOI":"10.1056\/NEJMoa1105575"},{"key":"ref3","doi-asserted-by":"crossref","unstructured":"Lazzaro MA, Krishnan K, Prabhakaran S. Detection of Atrial Fibrillation With Concurrent Holter Monitoring and Continuous Cardiac Telemetry Following Ischemic Stroke and Transient Ischemic Attack. Journal of Stroke and Cerebrovascular Diseases. 2012;21(2):89\u201393. DOI: 10.1016\/j.jstrokecerebrovasdis.2010.05.006","DOI":"10.1016\/j.jstrokecerebrovasdis.2010.05.006"},{"key":"ref4","doi-asserted-by":"crossref","unstructured":"Shafqat S, Kelly PJ, Furie KL. Holter monitoring in the diagnosis of stroke mechanism. Internal Medicine Journal. 2004;34(6):305\u20139. DOI: 10.1111\/j.1444-0903.2004.00589.x","DOI":"10.1111\/j.1444-0903.2004.00589.x"},{"key":"ref5","doi-asserted-by":"crossref","unstructured":"Alhadramy O, Jeerakathil TJ, Majumdar SR, Najjar E, Choy J, Saqqur M. Prevalence and Predictors of Paroxysmal Atrial Fibrillation on Holter Monitor in Patients With Stroke or Transient Ischemic Attack. Stroke. 2010;41(11):2596\u2013600. DOI: 10.1161\/STROKEAHA.109.570382","DOI":"10.1161\/STROKEAHA.109.570382"},{"key":"ref6","doi-asserted-by":"crossref","unstructured":"Fonseca AC, Merwick \u00c1, Dennis M, Ferrari J, Ferro JM, Kelly P et al. European Stroke Organisation (ESO) guidelines on management of transient ischaemic attack. European Stroke Journal. 2021;6(2):V. DOI: 10.1177\/23969873211027003","DOI":"10.1177\/23969873211027003"},{"key":"ref7","doi-asserted-by":"crossref","unstructured":"Kleindorfer DO, Towfighi A, Chaturvedi S, Cockroft KM, Gutierrez J, Lombardi-Hill D et al. 2021 Guideline for the Prevention of Stroke in Patients With Stroke and Transient Ischemic Attack: A Guideline From the American Heart Association\/American Stroke Association. Stroke. 2021;52(7):e364\u2013467. DOI: 10.1161\/STR.0000000000000375","DOI":"10.1161\/STR.0000000000000375"},{"key":"ref8","doi-asserted-by":"crossref","unstructured":"Mariani MV, Pierucci N, Piro A, Trivigno S, Chimenti C, Galardo G et al. Incidence and Determinants of Spontaneous Cardioversion of Early Onset Symptomatic Atrial Fibrillation. Medicina. 2022;58(11):1513. DOI: 10.3390\/medicina58111513","DOI":"10.3390\/medicina58111513"},{"key":"ref9","doi-asserted-by":"crossref","unstructured":"Cochet H, Mouries A, Nivet H, Sacher F, Derval N, Denis A et al. Age, Atrial Fibrillation, and Structural Heart Disease Are the Main Determinants of Left Atrial Fibrosis Detected by Delayed\u2010Enhanced Magnetic Resonance Imaging in a General Cardiology Population. Journal of Cardiovascular Electrophysiology. 2015;26(5):484\u201392. DOI: 10.1111\/jce.12651","DOI":"10.1111\/jce.12651"},{"key":"ref10","doi-asserted-by":"crossref","unstructured":"Tu HT, Chen Z, Swift C, Churilov L, Guo R, Liu X et al. Smartphone electrographic monitoring for atrial fibrillation in acute ischemic stroke and transient ischemic attack. International Journal of Stroke. 2017;12(7):786\u20139. DOI: 10.1177\/1747493017696097","DOI":"10.1177\/1747493017696097"},{"key":"ref11","doi-asserted-by":"crossref","unstructured":"Reichl JJ, Hamid KA, Burkard T, Vischer AS, Guzman C, Dudek D et al. PPG-based smartphone application vs usual care for atrial fibrillation screening: A European multicenter randomized trial. Heart Rhythm. 2025;S1547-5271(25)02741-9. DOI: 10.1016\/j.hrthm.2025.07.060","DOI":"10.1016\/j.hrthm.2025.07.060"},{"key":"ref12","doi-asserted-by":"crossref","unstructured":"Wouters F, Gruwez H, Vranken J, Vanhaen D, Daelman B, Ernon L et al. The Potential and Limitations of Mobile Health and Insertable Cardiac Monitors in the Detection of Atrial Fibrillation in Cryptogenic Stroke Patients: Preliminary Results From the REMOTE Trial. Frontiers in Cardiovascular Medicine. 2022;9:848914. DOI: 10.3389\/fcvm.2022.848914","DOI":"10.3389\/fcvm.2022.848914"},{"key":"ref13","doi-asserted-by":"crossref","unstructured":"Jauch EC, Saver JL, Adams HP, Bruno A, Connors JJ (Buddy), Demaerschalk BM et al. Guidelines for the Early Management of Patients With Acute Ischemic Stroke: A Guideline for Healthcare Professionals From the American Heart Association\/American Stroke Association. Stroke. 2013;44(3):870\u2013947. DOI: 10.1161\/STR.0b013e318284056a","DOI":"10.1161\/STR.0b013e318284056a"},{"key":"ref14","doi-asserted-by":"crossref","unstructured":"Kernan WN, Ovbiagele B, Black HR, Bravata DM, Chimowitz MI, Ezekowitz MD et al. Guidelines for the Prevention of Stroke in Patients With Stroke and Transient Ischemic Attack: A Guideline for Healthcare Professionals From the American Heart Association\/American Stroke Association. Stroke. 2014;45(7):2160\u2013236. DOI: 10.1161\/STR.0000000000000024","DOI":"10.1161\/STR.0000000000000024"},{"key":"ref15","doi-asserted-by":"crossref","unstructured":"Sanna T, Diener H-C, Passman RS, Di Lazzaro V, Bernstein RA, Morillo CA et al. Cryptogenic Stroke and Underlying Atrial Fibrillation. New England Journal of Medicine. 2014;370(26):2478\u201386. DOI: 10.1056\/NEJMoa1313600","DOI":"10.1056\/NEJMoa1313600"},{"key":"ref16","doi-asserted-by":"crossref","unstructured":"Gognieva D, Vishnyakova N, Mitina Y, Chomakhidze P, Mesitskaya D, Kuznetsova N et al. Remote Screening for Atrial Fibrillation by a Federal Cardiac Monitoring System in Primary Care Patients in Russia: Results from the Prospective Interventional Multicenter FECAS-AFS Study. Global Heart. 2022;17(1):4. DOI: 10.5334\/gh.1057","DOI":"10.5334\/gh.1057"},{"key":"ref17","doi-asserted-by":"crossref","unstructured":"Han D, Ding EY, Cho C, Jung H, Dickson EL, Mohagheghian F et al. A Smartwatch System for Continuous Monitoring of Atrial Fibrillation in Older Adults After Stroke or Transient Ischemic Attack: Application Design Study. JMIR Cardio. 2023;7:e41691. DOI: 10.2196\/41691","DOI":"10.2196\/41691"},{"key":"ref18","doi-asserted-by":"crossref","unstructured":"Weichert I. \u2018My watch kept on alarming all night about my heart rate\u2019: diagnosis of asymptomatic atrial fibrillation with fast ventricular response in a patient with a recent TIA as the result of a smartwatch alarm. Oxford Medical Case Reports. 2019;2019(3):omz014. DOI: 10.1093\/omcr\/omz014","DOI":"10.1093\/omcr\/omz014"},{"key":"ref19","doi-asserted-by":"crossref","unstructured":"Grond M, Jauss M, Hamann G, Stark E, Veltkamp R, Nabavi D et al. Improved Detection of Silent Atrial Fibrillation Using 72-Hour Holter ECG in Patients With Ischemic Stroke: A Prospective Multicenter Cohort Study. Stroke. 2013;44(12):3357\u201364. DOI: 10.1161\/STROKEAHA.113.001884","DOI":"10.1161\/STROKEAHA.113.001884"},{"key":"ref20","doi-asserted-by":"crossref","unstructured":"Rizos T, G\u00fcntner J, Jenetzky E, Marquardt L, Reichardt C, Becker R et al. Continuous Stroke Unit Electrocardiographic Monitoring Versus 24-Hour Holter Electrocardiography for Detection of Paroxysmal Atrial Fibrillation After Stroke. Stroke. 2012;43(10):2689\u201394. DOI: 10.1161\/STROKEAHA.112.654954","DOI":"10.1161\/STROKEAHA.112.654954"},{"key":"ref21","doi-asserted-by":"crossref","unstructured":"Larsen BS, Aplin M, Nielsen OW, Dominguez Vall-Lamora MH, H\u00f8st NB, Kristiansen OP et al. Excessive supraventricular ectopic activity and risk of incident atrial fibrillation in a consecutive population referred to ambulatory cardiac monitoring. Heart Rhythm O2. 2021;2(3):231\u20138. DOI: 10.1016\/j.hroo.2021.04.002","DOI":"10.1016\/j.hroo.2021.04.002"},{"key":"ref22","doi-asserted-by":"crossref","unstructured":"Germanova O.A., Reshetnikova Yu.B., Syunyakov T.S., Germanov A.V. Prediction of paroxysmal atrial fibrillation based on 24hour Holter electrocardiographic monitoring. Kazan medical journal. 2025;106(2):298\u2013307. [Russian: Germanova O.A., Reshetnikova Yu.B., Syunyakov T.S., Germanov A.V. Prognozirovanie paroksizmal'noi fibrillyatsii predserdii na osnovanii dannykh sutochnogo monitorirovaniya elektrokardiogrammy po kholter. Kazanskii meditsinskii zhurnal. 2025;106(2):298-307]. DOI: 10.17816\/KMJ631754","DOI":"10.17816\/KMJ631754"},{"key":"ref23","doi-asserted-by":"crossref","unstructured":"Shapkina M, Ryabikov A, Mazdorova E, Titarenko A, Avdeeva E, Mazurenko E et al. The Determinants of the 13-Year Risk of Incident Atrial Fibrillation in a Russian Population Cohort of Middle and Elderly Age. Journal of Personalized Medicine. 2022;12(1):122. DOI: 10.3390\/jpm12010122","DOI":"10.3390\/jpm12010122"},{"key":"ref24","unstructured":"Shkolnikova MA, Jdanov DA, Ildarova RA, Shcherbakova NV, Polyakova EB, Mikhaylov EN et al. Atrial fibrillation among Russian men and women aged 55 years and older: prevalence, mortality, and associations with biomarkers in a population-based study. Journal of geriatric cardiology. 2020;17(2):74\u201384. DOI: 10.11909\/j.issn.1671-5411.2020.02.002"},{"key":"ref25","unstructured":"Mehrabanfar AA, Adel SM. Atrial fibrillation among patients with stroke. Neurosciences Journal. 2008;13(2):196\u20138. [Av. at: https:\/\/nsj. org.sa\/content\/13\/2\/196]"},{"key":"ref26","doi-asserted-by":"crossref","unstructured":"Edwards JD, Kapral MK, Fang J, Saposnik G, Gladstone DJ. Underutilization of Ambulatory ECG Monitoring After Stroke and Transient Ischemic Attack: Missed Opportunities for Atrial Fibrillation Detection. Stroke. 2016;47(8):1982\u20139. DOI: 10.1161\/STROKEAHA.115.012195","DOI":"10.1161\/STROKEAHA.115.012195"},{"key":"ref27","doi-asserted-by":"crossref","unstructured":"Kishore A, Vail A, Majid A, Dawson J, Lees KR, Tyrrell PJ et al. Detection of Atrial Fibrillation After Ischemic Stroke or Transient Ischemic Attack: A Systematic Review and Meta-Analysis. Stroke. 2014;45(2):520\u20136. DOI: 10.1161\/STROKEAHA.113.003433","DOI":"10.1161\/STROKEAHA.113.003433"},{"key":"ref28","doi-asserted-by":"crossref","unstructured":"D\u2019Anna L, Kar A, Brown Z, Harvey K, Banerjee S, Korompoki E et al. Automated Continuous Electrocardiogram Monitoring Accelerates the Detection of Atrial Fibrillation after Ischemic Stroke or Transient Ischemic Attack on a Hyper Acute Stroke Unit. Journal of Stroke and Cerebrovascular Diseases. 2020;29(4):104669. DOI: 10.1016\/j.jstrokecerebrovasdis.2020.104669","DOI":"10.1016\/j.jstrokecerebrovasdis.2020.104669"},{"key":"ref29","doi-asserted-by":"crossref","unstructured":"Mannhart D, Lischer M, Knecht S, Du Fay De Lavallaz J, Strebel I, Serban T et al. Clinical Validation of 5 Direct-to-Consumer Wearable Smart Devices to Detect Atrial Fibrillation: BASEL Wearable Study. JACC: Clinical Electrophysiology. 2023;9(2):232\u201342. DOI: 10.1016\/j.jacep.2022.09.011","DOI":"10.1016\/j.jacep.2022.09.011"},{"key":"ref30","doi-asserted-by":"crossref","unstructured":"Frost L, Vestergaard P, Mosekilde L. Hyperthyroidism and Risk of Atrial Fibrillation or Flutter: A Population-Based Study. Archives of Internal Medicine. 2004;164(15):1675\u20138. DOI: 10.1001\/archinte.164.15.1675","DOI":"10.1001\/archinte.164.15.1675"},{"key":"ref31","doi-asserted-by":"crossref","unstructured":"Mont L, Elosua R, Brugada J. Endurance sport practice as a risk factor for atrial fibrillation and atrial flutter. Europace. 2008;11(1):11\u20137. DOI: 10.1093\/europace\/eun289","DOI":"10.1093\/europace\/eun289"}],"container-title":["Kardiologiia"],"original-title":[],"link":[{"URL":"https:\/\/cardio.elpub.ru\/jour\/article\/viewFile\/2946\/1942","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/cardio.elpub.ru\/jour\/article\/viewFile\/2946\/1943","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T17:16:11Z","timestamp":1793639771000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardio.elpub.ru\/jour\/article\/view\/2946"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,28]]},"references-count":31,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2025,12,28]]}},"URL":"https:\/\/doi.org\/10.18087\/cardio.2025.11.n2946","relation":{},"ISSN":["2412-5660","0022-9040"],"issn-type":[{"value":"2412-5660","type":"electronic"},{"value":"0022-9040","type":"print"}],"subject":[],"published":{"date-parts":[[2025,12,28]]}}}